HomeMy WebLinkAboutTYPICAL END DETAILTYPICAL END DETAIL
SCANNED
StCuce Goa*
1/411 = 1'-011
3 15/16
HEEL HT
B„
OVERHAN
ERRINE�EVAT1UNS BUILDING
SEEPLAN1 CG
OMPON ENT
SIMPSON Strong -Tie
WALL & (LG. I1EIGfITS A F F TRUSSESRMBCLLC.COM
OF MAIN HOUSE �..
DO NOT SET TRUSSES USING THIS LAY(
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRV,1
SINIPSC�N HANGERS RE_VISIC
CITY TYPE CARRYING MEMBER CARRIED MEMBER DATE DESCRIP
LUS24 4-1Od 2-10d
HUS26 14-16d 6-16d
HGUS26 20-16d_ 8-16d
HHUS26 2'14-16d 6-16d _.
HGUS26 2 20 16d 8-16d
j "' € HUS28 22 16d 8-16d
r' HHUS28-2 22-16d 8-16d
�w 8 HGUS28-2 36 16d 10-16d
THA422 !22-16d 6-16d
THAC422 22-16d 6-16d
LUS410 8-1 6d 6-16d I R E E E R E N'
HUS46 4-16d 4-1 6d
HUS48 6-16d 6-16d
LTHJR/L 12-10d HIP 4 10d _
JACK = 2-10dxl 112' & 2 Iod
*Attach hangers to 1—ply girders
w/ 1 1/2" 10d nails.
®Attach hangers to 2—ply girders i I____ O A D 11\
w/ 16d nails. TC ILL 2(
*Truss manufacturer supplies hangers R TC DL 0;
for truss to truss connections.
*All hangers connecting trusses to BC DL iC
building structure are determined by 0 BC ILL TYPICAL 1C
'ATTIC W/OSTORAGE
buildinq designer and supplied by builder. i PC ILL AS NOTED
ATTIC Light STORAGEBC ILL AS
21
7
WARNING ATTIC LIVINOGTED SPACE 41
Do not lift single trusses with spans greater than 30' DURATION 1,2
by the peak. Do not attach cables, chains or hooks DEFLECTION L/
to the web members. Refer to BCSI 1-03 Summary
Sheet provided for proper handling, installing and WIND SPEED 16
bracing methods. 2017 FLORIDA BUILDING
ATTENTION FRAMERS/CONTRACTOR ASCE 7 lo, CAT II, Par
Trusses are not to be cut or altered for any reason,'EXPOSURE
I If there is a problem, you must follow the procedures
listed below: MEAN HEIGHT
(1) Notify RMBC immediately. TC LL XX
(2) Secure proper Engr rgr'd for any repair. FTC DL XX
RM BUILBING COMPONENTS will not honor any backcharges
unless authorized by a RMBC Representative L BC DL XX
:nRoof trusses are not designed for additional attic O TOTAL LOAD XX
storage loads, unless noted otherwise. DURATION 1.0
*Attic frame trusses noted as storage/mechanical DEFLECTION L/
rooms are designed with additional 30 PSF BC LL
jcAttic frame trusses noted as attic living space m
are designed with additional 40 PSF BC ILL. SHEET
OMULTIPLE-PLY TRUSSES MUST BE FASTENED TOGETHER PEId .-.. _. ..
FNGINI-hRING NF FORF I HEY ARE SF . --'
LAYOUT TECH: RM
*WARNING! Inadequate size and/or fastening of bracingENGR TECH:_ RM
material is a major cause or erection dominoing. FILENAME: 00271,!
*Any party who cuts or damages a truss shall be
responsible for securing the engineering required
for the repair and for subsequent costs. _P...
*For proper installation of truss to truss connections,t,
refer to hanger installation guide for attachment purposes
;*This truss placement diagram is for the use of the U
fabricator, general contractor, and truss erection s
contractor. It is not intended to be a substitute for -f [
a framing plan, which is the responsibility of the """'`t.
architect or engineer of record to provide.
*Trusses are designed in accordance with theIn
LJI
ANSI/TPI 1-2014 National Design Standard for metal
plate connected wood truss construction. ai
Refer to BCSI 1-03 Summary Sheet for bracing':.
& truss design dwgs for additional permanent bracing., p __JI
i*FIELD BRACING is not the responsibility of the truss
fabricator, truss designer, nor plate manufacturer. W
(10
*Persons erecting trusses are cautioned to seek o
professional advice regarding erection bracing which II El
is always required to prevent toppling and dominoing. �(
*It is the responsibility of the builder to provide L J
adequate access roads into and through the site
for the safe delivery of trusses. \ f
*WARNING! The consequences of improper handling, < >
erecting, and bracing may be collapse of the J
structure, or worse, serious personal injury or death. Q N
f...,. .
IMPORTANT � "' C Q)! r
Approval of this truss placement is necessary r , O' -=I C
before production can begin. Verify all dimensions,
spans, pitches, overhangs, elevations, and bearing
conditions. Acceptance of this truss placement y� LLI
assumes total responsibility. The trusses will be I_f_
built in strict accordance with this placement.FIQ
��C y =D
OP
SIGNED � a
DATE