Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSPage 2 1/29/18 Sloped Wood Deck Section 13529 Indian River Drive Jensen Beach, FL Design Pressures: 1) Field P1 = 33;4*(-0.9 — 0.18) = -36.1 psf 2). Perimeter P2 = 33:4*(-1.7 — 0.18) _ -62.9 psf 3) Corners P3 , = 33 44*(-2.6 —0.18) _-93.O:psf I Attachment. Requirements: 'Based on RAS7133 and F.L. #17022=R7 (170.22.1);. Table A.; the following are our recommended fastening requirements for the 26 gauge 5V Crimp Metal Roof Panels:. . Field: Maximum of 12".odc. screw sp I ing (Table A - #9 Screws "Method 1) Perimeter: Maximum of 12" o./c. screws akin f able A = #9'Screws'"Method 1 spacing ( T) Corners: Maximum of .12" o:/c:• screw spacing, . (Table A - #10. Screws "Method 2) ;Notes: Comers and perimeter area dimension shall not be less than a = 410." All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and :the ,Florida Building ' Code 2017. 1 .. • . Wind load calculations based, on ASCE 7-.10 and. information provided by client. , All. work" shall be. inspected by our field engineer or city. inspector to' verify compliance with specifications. I Sincerely, I• ZW 41 I eth'Le'B`lanc7-P.E. - cl tFede'ral Engineering & Testing, Tnc. '1~lorida Reg. -No. 59394 . Certificate,of Authorization #5471. Miami=Dade County Certification #16-0203.07