Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING*s Business & Professional Regulation BCIS Home I Log In I User Registration I Hot Topics I Su Florida Product Approval a la— r a, USER: Public User. Product Approval Menu > Product or Application Search > Aoow Application Type fl Code Version / Application Status Comments Archived SCANNED BDePF6li[NaIE A80in DBPR DBPR DIUIS IONS CDNTACT DBPH Publications I rac staff I BCIS Site Map I Links I Search RECEIVED APPlirati gDeta am FEB 2 0 2018 Revision 2017 ST. Lucie County, Permitting Approved 08/18/2017v. date reapply 08/21/17 G Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoos f ILE COPY Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Address/Phone/Email 1 r 1 Quality Assurance Representative Address/Phone/Email Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net I�.dI.7e1�I:i Compliance Method l Evaluation Report from a Florida Registered Architect or a Licensed Florida i Professional Engineer . D Evaluation Report - Hardcopy Received Florida Engineer or/Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 I Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. O Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.Ddf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL1897 2012 ! UL 580 2006 Equivalence of Product Standards Certified By 1 Sections from the Code i Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method i Option D O8/18/2017 08/25/2017 08/28/2017 10/10/2017 `FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (116j 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel I mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. I 17022.2 12 - "5V Crimp" (116) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Installation Instructions FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2_5 V CRIMP 0.032 ALUM ssr.ndf Created by Independent Third Party: Yes 17022.3 3 - "1.5" 1Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No� FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24aa ssr.odf Impact Resistant: No f Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022,3 1.5 MECHANICAL installation method listed in this report and applicable code seam 24oa ssr.odf sections of FBC. Refer to manufacturer's installation Created by Independent. Third Party: Yes instructions. 17022.4 I 4 -I "1.5" Mechanical Seam" (R5) I 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with dips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/;Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code ALUMINUM ssr.gdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.5 15 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached m 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in/ HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +,N/A/ -Table A Installation Instructions FL17022 R7 II FL 17022.5_ 1.0 NAILSTRIP ssr.0df Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports Palm City, FL 34990 Compliant with Florida Building Code 2017 (6' ed.) Compliant with Florida Product Approval Rule # 61G20-3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above METHOD 2 METHOD 3 METHOD 4 -93.5 PSF -201 PSF -228 PSF 26" o.c._ 8" O.C. 6" o.c. 22" o.c. 22" o.c. 22" o.c. #20 #20 #20 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test. Report 1315893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL 1897-1*Design pressure margin of safety 2;1 ��tC4 ryOry,,' �. ,. >. Locke Bowden, P.E. does not have, not WAI acquire a financial in4t yq L� sg facturing or distributing products under this evaluation. - Locke Bowden; P.E. is not owned, operated, or controlled by airy cowiparilipm3r93iaLturep, or distributing products under this report.6/77 ; • • -(� .lid • �r �� � tOf?1nP• ��;, 'ONAL ... • • are ;� rj:::►rs►�► . I FL17022.1 6V Crimp (26GA Steel), 24" Wide Roof Panel - Details _imitations: I 1. Underlayment to be compliance with current Florida Buildii 2. Minimum slope to be compliant with Florida Building Code 3. Products are compliant for State of Florida product approv 4. Engineering analysis for "project specific approval by local 5. Fire classification is not part of this acceptance. Shear dial 6. Support framing in compliance w/FBC 2017 61h ed., Chaptl Structural Loading. 7. This report does not imply warranty, installation, recommei 3W Deck: 1532" or greater Plywood, or Wood plank Code (FBC)2017 6th ed. )l7 61h ed., and per with Manufacturer's installation reference. per Rule 61G20-3. Compliance Method: 1-D ithorities w/jurisdiction is allowed by other registered engineers. ragm values are outside this report. 22 for Steel, Chapter 23 for Wood and Chapter 16 for product use outside of this report. #9 ■ 1-1'/2' Min. or #10.1i-1/2" Min. per Taft A' for Row 5-V Crimp Roof Panel Spacing and Design pressures Hex Washer Head Wood Screws Nominal 12" _ Nominal 12" �I r O.C. I -f O.C. 1 Fasten y9 x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length T Deck-15/32" or greater Plywood, or - Wood plank