Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFINGSCANNED BY St Lucie County BCIS Home I Log In j User Registration Hot Topics 1 Submit Surcharge i Stats & Facts I Publications FBC Staff BCIS Site Map Links Search Florida i� Product Approval F '{ USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL'7C 56fR'4 Application Type Revision Code Version Application Status Approved Comments Archived Product Manufacturer EliteAluminum Corporation 7.T Address/Phone/Email 4650-Lyoris`Technology-P6rkway Coconut Creek, FL 33073 (954)949-3200 dk@dokimengineering.net Authorized Signature Do Kim dk@dokimengineering.net Technical Representative Bruce Peacock Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954)949-3200 bpeacock@elitealuminum.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Do Kim, P.E. the Evaluation Report Florida License PE-49497 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/30/2022 Validated By CBUCK Engineering Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL7561 R4 COI Cert of Indenendence.Ddf Sections from the Code 1709.2 Product Approval Method Method 2 Option B Date Submitted 08/15/2017 Date Validated I 08/16/2017 Date Pending FBC Approval 08/20/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description �i5Er1 � Aluminum/Aluminum Composite Panels 3"/4"/6"x0.024"x1Ib EPS Composite Panel, 3"/4"/6"x0.032x11b EPS Composite Panel, 3"/4"/6"x0.024"x21b EPS Composite Panel, 3"/4"/6"x0.030"x21b EPS Composite Panel, Limits of Use I Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL7561 R4 II 2017 FBC-Elite Aluminum Coro -Install Instruct.Ddf Impact Resistant: No I Verified By: Do Kim, P.E. PE 49497 Design Pressure: +80/-80l Created by Independent Third Party: Yes Other: In HVHZ, not to be used in structures considered Evaluation Reports living areas per FBC Section 1616 unless impact protection FL7S61 R4 AE FL 7561 Evaluation Report-2017 FBC.Ddf Created by Independent Third Party: Yes is provided. See installation drawing for nominal allowable design pressures and spans. I Badt Next :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, co tact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may pe used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under I Chapter 455, F.S., please click here . Product Approval Accepts: .fist'. ® 0 2 Credi Card Safe ELITE PANEL SPAN TABLES: 1. Net allowable loads are permitted to be multiplied by 1.67 to derive ultimate loads (psf). 3'- 0 024� -- 1 - LB EPS4RANELS CA L00WABL-2,!CLEAR SPAN CkiARTS)� NET ALLOWABLE LOAD (PSF)t MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 IO 16.17_ 15.76 15A3 14.10 Q� 4s 13.44 1222 103 30 10.70 10.7E 9.41 6.60 40 9.22 922 6.60 2.85 50 8. 7 B.17 3.79 60 7.40 639 0.98 70 6 8l 4.51 BO 6.33 e..6 4' x 0.024 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 I9.00 1 19.00 17.17 1653 20 15.01 15.01 13.93 30 I25e I250II3840 10.97 10.97 U-00 M15 7.44 6.22 9.13 751 3.64 5.58 1.07 -00 8.02 3.64 6' x 0.024 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/BO L/120 L/180 L/240 10 23.00 2124 21.47 20.85 20 18106 I8A6 le.06 lea6 30 l5. 3 15.13 15.13 IS13 10 1334 1324 1334 1334 50 IF-10 1810 12I0 10.91 60 ILl7 I1.7 11.17 BA3 70 10.44 10.44 10.30 5.95 BO 9.85 9.B7 1 8.43 3.47 3' x 0,032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)t MAX. ALLOWABLE SPAN (FT) L/80 L/120 I L/180 L/240 10 17.10 17.50 16.91 13.96 20 L6.64 15.96 14.06 M16 30 15.17 14.06 11.21 8.36 40 13.69 12.16 8.36 4.56 50 1222 11,21, 5.51 1171, 60 10.75 9.36 2.66 70 9.27 6.46 80 7.80 4.56 4' x 0.032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)t MAX. ALLOWABLE SPAN (FT) L/80 L/L20 L/180 L/240 10 20.50 20.50 20.11 19.24 20 19.6I 1924 17.49 15.74 30 18.17 17.49 14.87 le.e4 40 16.72 15.74 1224 8.74 90 15.28 13.99 9.62 125 60 13.84 12.24 7.W 1.75 70 12.40 10.49 4.38 - BO 19.95 8.14 1.71 6' x 0.032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) 080 L/120 L/180 L/240 10 24.00 24.e0 24.00 23.42 20 23.34 23.el 2Le2 20.22 30 22.10 21.63 19.42 I7.02 40 20.66 20.05 17.02 13.92 50 19.62 18.47 14.62 10.62 60 10.39 16.89 12.22 7.42 70 17.14 15.30 %82 4.22 80 15.91 13.72 7.4E Lee 3' x 0.024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 Ism 18.93 lent 17,66 20 mil 17b6 1636 NJ 6 30 16.90 1636 14A1 f2A6 40 I-3A9 15.06 12,41 9.Bfi 50 14.18 13.76 1051 7.26 60 12.97 12.46 8.57 4.67 70 11.37 11.16 6.62 2.07 90 1026 9.06 4.67 4' x 0.024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD <PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 l0 21.97 21.97 21.52 20.97 20 29.77 20.77 19.86 1e.76 30 19-97 19-97 1821 1655 40 18.36 1836 16.55 1434 50 17.16 17.16 14.89 IF-13 60 15.96 1536 1324 9.93 70 14.75 14.75 Ilse 7.72 _ 80 I355 I7.37 9.97 5.51 6' x 0.024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 l0 23.93 23.93 23.88 23.60 20 2320 23ea 23.03 22.46 30 22.47 22.47 2? is 2133 40 21.75 21.75 2133 2020 50 21,02 21.02 20.49 19.07 0 2029 2029 9164 1 .94 70 I9.57 1957 18.79 16A1 BO 18.04 IB.B4 17.94 1548 GENERAL NOTES I. Composite panels shall be constructed using type 3003-11154 ahuninurn racing.9, I or 2 PCF AST'M C-578 carpenter brand ITS adhere to aluminum facings with Ashland Chemical 2020D ISO grip. Fabrication to he by Elite panel products only in accordance with approved fabrication nrellrods. 2. Elite roof panels maintain a (IL 1715 (hit) class '13' (ext) rating and are NER-50I approved. 3. This specification has been designed and shall be fabricated in accordance with the requirements of the Florida building Code 6" Edition (FBC), composite panels comply with Chapter 7 Section 730. Chapter 8 Section 803, Class A interior finish, avid Chapter 26 Section 2603. All local building code nlnendnents shall be adhered to as required. 4. 'The designer shall determine by accepted engineering practice the allowable loads for site specific load conditions (including load combinations) using the data Frain Lite allowable loads tables and spans in this approval. 5. Deflection limits and allowable spans have been listed to meet F13C including (Ire HVI17. In HVH7- this product shall be used in structures "not to be considered living areas' per Section 1616 unless impact resistance in accordance to the 11 VI I7_ requirements are 1nel. 6. Surely factor or2.0 has been used to develop allowable loads and spans from testing in accordance to the Guidelines ror Alwninum Structures Part 1 anti confirms to the F13C Chapter 16 and 20. 7. T'esling has been conducted in accordance to AST'M E72-05: Strength'rest of Panels for Onilding Construction. S. Reference test reports: HETI-054988, H1311-06-2104. H01-06-2066, HETI.06-2105, HETI-06-2067, f{I;f1-05-1002. HE•1I- 06-2107,11ET1-05.1987, I IETI-06.2069. HETI-06-2070, I IETI-06.2071. ITETl-05-1994. f irl1-05-1991. I IEI'1-06.2072. HETI.06-2073, IIETh-06-2074.IIETI-OS-1996, IIETI-05-1939,1IETI-O5-1993, HETI-05-1985, HETI-OS-1995. ITETI-O5- 1990, IIFTI-05-1997. HETI-05-2037, ITET'I-05-2029, IIE•TI-05-2039, HETI-05-2030, IIF.,TI-05-2041. IlETI-05--1.048. lIET'I- 05-2036,11111'605.2031, IIET'1-05-2038, 11E1'1-05-2065.11E1.1-05 2040, HID-1-05-2042. 9. Unctr interpolation shall be allowed for figures within the tables shown. 10. Panels with fun beans shall be considered equivalent to similar panels without ran beams. Design prol-essionals may include 3' x 0.030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 20.11 20.03 19.42 10.01 20 17.58 16.35 30 17.93 17.56 15,73 16.B3 16.35 W.89 15.74 15.12 I2.056014.64 I3.B9 10.21 V"43 70W.55 IP-66 M36 8012.46 IL43 6.52 4' x 0.030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 IO 24.17 24.17 24.V 24.17 ED 23.64 23.64 23.41 23.11 30 22.57 22.57 21.90 21.01 40 21.51 2L51 20.39 19.91 SO 20A5 20.45 IS.BB 16.80 60 19.39 19.39 17.37 14.70 70 19.33 18.33 I5.B6 12.59 80 L726 1726 14.35 1a49 6' x 0.030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 24.00 24.00 24.00 23.94 20 23.65 23.65 23.34 22.84 30 22.94 22.94 22.59 21.85 40 22.23 22.23 21.85 20.65 50 21.53 21.53 2L10 19.66 60 20.92 20.82 20.36 B.87 70 20.11 20.11 19.61 17.87 80 19.40 19.40 18.87 16.89 SEAL JOINt;t= H CONTINUOUS CA 00WE,)0aH -- i BOTTOM FACINGS INT R n.KIN. CROSS SFCTIDN OPTIONAL GUTTER OR GRIP CAP SLOPE 4' MAXIDTH INTERLOCKING PANEL (1/4'/FT MIN SLOPE) °0000°ago - 0000�0°EPS CORE ILB OR B 0000000 O°O000O0 00 OD O o ALUMINUM BOTTOM f 00 s FACINGS Con I F�-CLEAR SPAN (U INSIDE TO [NS10E 00O 0O.H. 0 ENGINEER OF RECORD TO PROVIDE 00 36' MAX IN FRONT 6 25% FOR ROOF CONNECTIONS 6 AOD THICKNESS OF o0 OF PANEL MOTH 8 SIDES SUPPORTING STRUCTURE DETAIL BY WALL FOR TOTAL O C THIS OR ANY OTHER ENGINEER PANEL SPAN 00 (12' MAX AT SIDES) EPS ROOF PANEL/ SPAN DESCRIPTION DO KIM 6, ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Td:(813)957-9955 J m > J 0 W W toa c3 0-2a O -YL n W U) F.- macD F- 65- 5 &EDP 0-30 O OLL ��tr U 0 0 ZD 0. E c m U Q W Due W 2 Oz EF U o�Fu c c U ? F- o Q �J 0 0JU) ILOU U.<< OO 'IT IL W 0 u DO YEON KIM, P.E. FLA. REG. NUMBER 49197 DO KIM 6 ASSOCIATES. LLC CA4 76987 PO BO% 10039 Tampa. FL 33679 Drawing No. - FL-1001 SHEET 1 OF 1