Loading...
HomeMy WebLinkAboutENGINEERINGCONTRACTOR: Master Craft Aluminum r•- DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADMl Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF , 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: VuLT =150 MPH. V-c =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure C 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1 - Patio Cover / Screen Room: Non -Habitable, Unconditioned Scope of Work: Does not include analysis of remaining existing structure, Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.( Foundation Design Existing concrete. No additional concrete footing or slab is required to resist the loads imposed by the proposed construction if the existing slab is a minimum 4" thick with an 8" x 8" thickened slab edge and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or # 12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/-1% - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vL Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 u. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete hrstitmeManual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Door location shall be determined by contractor in the field. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND EXPOSURE_ HAVE BEEN DETERIVIINED USI " 'HE ADVANCED TECHNOLOGY COUNCIL '(EBSITE AND GOOGLE EARTH. 00N0► ALEID MS.TEi'ilLRS 0 10, ATM 0H MIEgb ARE THE RESPONSIBILITY OF THE OONTRAOTOR OF RECORD 8'-5" T 8'-5" T 1 8'-0" SCANNED C` + 3 r ELITE 2000 COMPOSITE PANEL: (FPA: FL7561-R4) 150MPH/EXP C 3"x48"xO.024" (1.0# DENSITY FOAM) MAX SPAN: q_-q_ = 11'-3j" 00 I THESE PLANS AND L[ ,p(IROSM lVORJ'� ARE SU13,BT 70, AN"' COP;rill Fu` IONS ROMEO U FIDD IN8Pr('T0ti9'rF;AT Br'lV BE INECESSAJ,Y liV 0RUER 1'() COMPLY WITi`I AL.L P Pla6ICAF-kC. r����+e 12'-3" Z Q (L N Q .I W U x Q 4TH WALL IB BEAM 12'-3" ST. LUCIE COUNTY BUILDING DIVISION 1=`OR C®4�3EsLln u�� REVIE;1111ED BY DATE Z-20'-1 `P PI.ANB AAib PERM T MUS aE KEPT ON JOB OR No IFJ""t `7'fDFd t`r'iI I, t3E MADE 2X3 END BEAM DENSITY FOAM 30SITE PANEL A-3 13'-9" EDGE BEAM 25-0" 14'-0" 40'-0" 3'X4WX0.024' COMPOSITE PANEL Q - W ch tL o O J = � Q= i .•,. co - PROF64IbNiSl SEAL C 2X3KB (TYP) CD S-5 -A S- C o A-3 _ oo A-3 c A-2 is X X X I 2X3 M 2X3 1X3 1X3 . B-1 B C-1 A-2 A-2 A-2 12'-3" 12'-3"- 6 -86'-8" o El ❑ Edrui rui OV d n W LLJ LL Z W m C .. lY am Wm LJ d 2 2 Z QN =� Z p:3 W I- i_ cc - I►Er Z 0 J � J - Q F-• Z as m m Q LLl w.-jT14 N OLLI Z �' iz Z Q N Z CA Lu W tY W a IL S m J Z CJ (D � O oco�M d O(9cnraa..W DRAWN BY GD DATE DRAWN 01 /30/18 REVISION SHEET NO: A-1 ALUMINUM MEMBERS DIMENSION& HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.046" „. A. 2x3:2"x3"x0.050" 2x4: 2"x4"x0.050' ��• •.• v�� 2x5: 2"x5"x0.050" �•cn 0 OPEN BACK SECTIONS 1x2: 1"x2"x0.040" - �; W * Q 1 x 3: 1" x 3" x 0.045" = U (n'•. F- W _ SNAP SECTIONS 1 I CHAIR RAIL MEMBER 2 x 2 Snap: 2" x 2" x 0.045" 2x3Snap: 2"x3"x0.050" 1 I I I i•' �i/ �jy'•••....•••' ��� 4" 0.045" -- -- 2 x 4 Sna : 2" x x p 3X3X0.070 II — — — — — � � SELF MATING (SMB) i 2 x 4 SMB:.'2" x 4" x 0.044" x 0.100" I 1 2" x 2" x 1/8" 3" LONG AN 2 x 5 SUB: 2" x 5" x 0.050" x 0.100" i i W/ (3) #14 x 3/4" EACH I I 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" 1 1 - FLANGE ❑ 2 x 7 SMB: 2" x 7" x 0.05T' x 0.120" 1 I 2" x 2" x& x 118" ALUM ANGLE x UPRIGHT Q OC 2 x 8 SNIB: 2" x 8" x 0.072" x 0.1W' V x 3" OB W/ IN' CONCRETE I I I I EACH SIDE OF UPRIGHT I I 0 W w 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" SCREW ANCHOR6"FROM UPRIGHT & AT 24" O.C. I I W/ 3!8" DIA. x 3"CONCRETE a d 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" (MIN. 2 3/4" EMBED.) I I ANCHORS ON EACH SIDE (3) #12 x 3/4"SMS SCREWS Lu MINIMUM FASTENER EDGE DISTANCE:1/2" I �=' oC .i Z v w e Q MINIMUM FASTENER SPACING: 3/4" — — — — m O m ° ° W Ci i CONCRETE SCREW ANCHOR: ° d W CA SIMPSON TITEN HD OR EQUIVALENT ' ° e Z Q N _j W SHEET METAL SCREWS (SW):' : ° ° z 421z O u Z uW IT W / BUILDER OR EQUIVALENT ° ' f e ' °' <' ! o ' ' 0 .. H � C B CHAIR RAIL TO UPRIGHT DETAIL M 3" x 3" POST TO DECK CONNECTION DETAILS A-2 SCALE: NTS A-2 SCALE: NTS (, ti a Q W {yFy W O WN N yZ uj Z � � V 1/8"x2"x2"EXTRUDED ANGLE 5052 H-32 ALLOY • • (3) #12 x 3W SMS o Z q s p • INTO DJ N W WOOD: •'a" •' +'°, ,+U #10 x 3" WOOD SCREWS, 6" FROM GIRT & @ 12"O.C. CONC SLAB / FOOTINGEDMENT 1/� DIA x 3"CONCRETE3"x 3"x 0.070" SEE PLAN : a •SCREWANCHOR,6" I POST s m•;FROM d•.a GIRT&@24"O.C. ' ;' <�• ,s. N 1 (4) #10 x 1 1/2" INTO W 0 SCREW BOSS I I (2) 3/6" DIA. CONCRETE SIDE VIEW 0 a -W SCREWANCHORS (3" CONC. EMBED) I 1 W x 3" x 1/8" EXTRUDED J POST BASE W/ (2) 30' F N DIA_ THRU BOLTS (1) 3/8" DIA. CONCRETE SCREWANCHORS / I UPRIGHT �� W f� tp Z U 0) 2" x 2" OR 2" x 3" HOLLOW (2 IX- CONC. EMBED) I PRE -HUNG w Q N 1 SECTION GIRT I DOOR JAMB d U N d u. — DRAWN BY 4 GD 1"x 3" BASE PLATE ° DATE DRAWN ANCHORED TO CONC W/ 1/4" ' . ° a , a• + 01 /3011 CONCRETE SCREW ANCHOR < a + ° REVISION (MIN. 1 1/4" EMBED) a Q C' 6" MAX EACH SIDE OF POST °.,,• •"• AND 24" O.C. MAX 1X3 TO HOST STRUCTURE DETAIL B-1 A-2 SCALE: NTS 3" x 3" POST TO CONCRETE CONNECTION DETAIL a•a ; ' • 2 /�i-2 SCALE: NTs FRONT VIEW SHEET NO: DJ-1 UPRIGHT TO CONCRETE PRE -HUNG a A-2DOOR LOCATION DETAIL SCALE: NTS A-2 (4) #14 x 4 -- `,MS W/N6 NE WASH— � ER PANEL W x 0.062" ALUM RECEIVING CHANNEL +' W/#10x3/4"TOP ANDy4 BOTTOM AS END CAP 2" x 3" x 0.070" TOP RAIL - NO ANGLE REQUIRED UNLESS SPLICED OR CORNER -ATTACH W/(4)#10x4"LG 2x3PB Ft 2" x 3" x 0.070" TOP RAIL W/ (4) #10 x 4" SMS INTO 2"x2"x3"LG Y .a z,'. 2"x2"xW x 1/8" ANGLE— x 1/8" ANC (4) #10 x 3l4" (4) #10 x 3/4" SMS INTO SMS INTO SCREW BOSSES I SCREW BOSSES (2) INTO TOP RAIL (2) INTO TOP RAIL (2) INTO POST (2) INTO POST CONNECTION AT CORNER VL SCALE: NTS W x 0.062" ALUM RECEIVING CHANNEL W/ #10 x 3/4" TOP AND BOTTOM AS END CAP (4) #14 x 4 7/8" SMS W/NEOPRENE WASHERS PER PANEL COMPOSITE COMPOSITE PANEL 3/8" DIA. RU BOLTS 2"xWSMB 3" x 3" x 0.093' S-3 COMPOSITE ROOF TO POST CONNECTION A-3 SCALE: NTS (4) #14 x 4 7/8" SMS W/NEOPRENE WASHERS PER PANEL 3" COMPOSITE ROOF PANELI 3" COMPOSITE ROOF PANEL 2" x 3" x 0.059' (4) #14 x 4 7/8" SMS END BEAM W/NEOPRENE i WASHERS PER EXISTING PANEL BUILDING 1.1/8" x 21/8" xl 1/8" x 0.050" 4) 3/B" DIA 1 ALUM RECEIVING CHANNEL ( THRU BOLTS W/ (3) #12 x 3/4" SMS EACH SIDE OF BEAM & (2) 3/8" DIA. 2" x 8" SMB I THRU BOLTS INTO THE POST 3/8" DIA. THRU BOLT 3" x W POST (4 TOTAL) _ x3"P — SMB 3""x 3" POST S -? COMP. ROOF TO POST 4TH WALL DETAIL A-3 SCALE: NTS (4) #14 x 4 7/8" SMS W/NEOPRENE— WASHERS PER PANEL 2"x8"SMB 1 1/8" x 2" x 1 1/8" x 6" x 0.062" ALUM RECEIVING CHANNEL W/ (7) #14 x 3/4" SMS INTO EACH SIDE OF BEAM & (7) #14 x 1" SMS INTO CORNER POST COMPOSITE PANEL 2" x W TOP RAIL —w/ (4) #10 x 4" SMS INTO POST 2"x2"x3"LG x 1/8" ANGLE (4) #10 x 3/4" SMS INTO —SCREW BOSSES (2) INTO TOP RAIL (2) INTO POST S-4 COMPOSITE ROOF TO POST CONNECTION A_3 SCALE: NTS • • �' lL 6•'. O O. Q HING _� co c (� Wul N P�f/'1R Inu CCd� �\ EXISTING' � El ❑ L BUILDING 0 O W u, 2 I W ce m G ILL p Z W m z ai � ai 0 ai m LL a w JLLJ I W Vf� Z a w < w �z Zw F W PuJ ccLL a S-2 COMP. ROOF TO CORNER POST 4TH WALL DETAIL A_3 SCALE: NTS W COMP ROOF BEAM `m � 12" 3 k. 2" x 3" x 0.059' UPRIGHlI KNEE BRACE • . '.'..a, • .. I 3 1 1/2" x 2 VW x 1 1/2" x 0.062" x 2" LONG ALUM Ira RECEIVING CHANNEL W/ (3) }} #12 x 314' SMS EA FACE & i (3) #12 x 3/4" INTO POST t Cam I S-5 KNEE BRACE CONNECTION DETAIL ems., A_3 SCALE: NTS J :x ; - G � � I Z i CUB I G J i J m Z cc �— z$oco a ari m S $ 6 Q W w,Tm a! OZ�emm u Z V' os-• Z O VI W r� LL Nuw N W N i W G_ W Qa U m J LLI �F-04 Z U.� rn O QO4oM OC OrO-j d (9NaII GD DATE DRAWN 01 /30/18 REVISION SHEET NO: A-3