Loading...
HomeMy WebLinkAboutPHOTOVOLTAIC OPERATED SYSTEMi N.'s.1 Ma moor tsar. How It works: Direct Open S Phwovoltaic Operated System The direct pumped system has one or more solar energy collectors installed oil the roof and a storage tank somewhere below, usually in a garage or utility room. A pump circulates the water frorn the tank LIP To the collector and back again. This is called a direct (or open loop) system because the suns heat is transferred directly to the potable water circulating through tl le collector tubing and storage lank; no anti- freeze solution or heat exchanger is involved. This system has a photovoltaic cell that senses when There is enough solar insolatlon available to heat tiie home's hot rva ter. The PV cell powers a X pump avhich circulates the water from the storage tank to the solar collector. A slush -type freeze protection; valve installed near the collector provides freeze protection- Whenever temperatures approach freezing, the valve opens to let swarm !ureter flow through the collectorThe collector also allows for manual draining by closing the isolation valves (located above the storage tank) and opening the drain valves. Soiene Solar HOT b'✓ater systems 800.79,SOLAR yr :v-.sol en e-usa-co m SL•213 Oink.." opon Loop PV sch,,MIjC,IM1jtl i "GANNEU BY St Luele County Vacuum Air breaker vent Pressure r- relief valve freeze II prevzMon i valve Drain Ball valve Check Calve .• E � , ll"j��jjJ,� if � /,J� s � 1 11! l � f ?CZ•� Hot water out• , 1 Tank ' , I i 1 1 Tanksensor ,- M���6A • tc� SOLAR HOT WATER SYSTEMS Circulating pump n Cold Ball water valve in IP!'rf1,.�y � , FSEC ran.Jr_un 314/14 3n0PM I �_ SOLENE COLLECTOR GENERAI_.__)TES: 1. APPUICABL'E LODE: 2017 FLORIDA BUILDING CODE (6TH EDITION) & ASCE-7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE rESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27 ° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. BUILDING NOT TO EXCEED 30'-0" ROOF HEIGHT. CONTRACTOR RESPONSIBLE TO VERIFY ROOF SLOPE. 4.EACH BRACKET SHALL BE FASTENED TO THE COLLECTOR WITH (1) ST STEEL CARRIAGE BOLT PER CONNECTION. EACH BRACKET SHALL BE FASTENED TO ROOF TRUSS WITH (1) 8" DIA. A276 STAINLESS STEEL LAG BOLT. SEE SCHEDULE FOR LAG BOLT DESIGN EMBEDMENT. 5. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO SOLENE INSTALLATION MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SOLAR SPECS. 7. ALL LAG BOLTS THIS SHEET SHALL BE A276 STAINLESS STEEL UNLESS OTHERWISE SPECIFIED. 8. SOLENE COLLECTOR(S) THIS SHEET SHALL BE ALL SOLENE AURORA AND SLSG (SPLIT GLASS) COLLECTORS. 9. PVC PIPE RISER/SPACER IS REQUIRED FOR PIPE CLAMPS WHERE PIPE ELEVATION VARIES. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) OR LOCAL GOVERNING CODE. ULTIMATE V.�d WIND Vasa WIND Vase WIND QUANTITY OF EMBED. COLLECTOR WIND SPEED PRESSURES PRESSURES PRESSURES BOLTS - BRACKETS DEPTH LAYOUT V& (MPH) ZONE 1(PSF) ZONE 2 (PSF) ZONE 3* (PSF) PER COLLECTOR REQ. 110-140 17.5 , -27.9 17.5 , -48.6 17.5 , -71.8* (4) e' DIA. (4) BRCK. 2" ** PORT., LAND. 141-175 26.8 , -42.7 26.8 , -74.3 26.8 , -109.9 (4) 8" DIA. (4) BRCK. 3" ** PORT., LAND. -- PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, RESPECTIVELY. --SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND SPEED PRESSURES WITH EXPOSURE "C", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'4" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.R.C. MINIMUM Vasa WIND PRESSURE SHALL BE 16.0 PSF AND -16.0 PSF PER ASCE 7-10 SECTION 30.2.2. EFFECTIVE DESIGN WIND AREA IS 10 SF PER COLLECTOR. - ** LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDING ANY ROOF DECKING. * INSTALLATION OF COLLECTORS MUST BE IN WIND ZONE 1 AND 2. WIND ZONE 3 INSTALLATION REQUIRES SITE SPECIFIC STRUCTURAL ENGINEER'S APPROVAL. 4'-o'�TY . o W z0 I oN � 1 I ----"--e4-z -ffcan----� ce 1- _--- -- ------ -- ----- \� SL-3 SLL-3 TYPICAL COLLECTOR PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN tl SCALE: NONE NOTi, �R TILE ROOFS, SOLENE MOUNTING BRACKET WITH LIFT KIT ASSEMBLY SHALL BE USED. ROOF DECKING NOT SHOWN FOR CLARITY. REFER TO SCHEDULE FOR REOUIRED COLLECTOR LAYOUT FOR EACH WIND SPEED. 0 SOLENE ALUM. MOUNTING BRCK. TYP 4 PLCS. SEE SCHEDULE THIS SHEET SOLENE ALUM. MOUNT] 2'-O" O.C. TYP. 2'-O" O.C. TYP. BRCK. TYP 4 PLCS. SEE SCHEDULE THIS SHEET I a o I� 1= cd F- Lu I�INI�I E' CD EA ' W C) W. Ln LL W CD I WO� C, C� 0 O PORTRAIT ORIENTATION TYPICAL COLLECTOR ORIENTATIONS 11-0" - ROOF SHINGLES TYP. SOLENE ALUMINUM MOUNTING - BRACKET. SOLENE — COLLECTOR TYP. - #2 S.Y.P. WOOD ROOF TRUSS BEYOND a" DIA. ST STL LAG BOLT TYP. SEE SCH FOR EMBED DEPTH REQ TYP. WOOD SHEATHING TYP. REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL TYPICAL ASPHALT METAL SHINGLE CONNE(RION DETAIL 3 SCALE: 1 Z'=V-0" SL-3 Icl: Icl: I� I1 alb UJ �I Lu LIQ w�C) Lu LANDSCAPE ORIENTATION - ROOF SHINGLES TYP. SOLENE ALUMINUM MOUNTING BRACKET. SOLENE 00� TYP. SOLENE ALUMINUM71 FRAME SECTION TYP. ' Rt 16' STAINLESS STEEL CARRIAGE BOLT �FB TYP. PER MOUNT BRACKET Sr. LiJcie Co SOLENE ALUMINUM _ FLUSH MOUNT BRACKET SLOTTED HOLE TYP, IN FRAME TYP. TYPICAL CARRIAGE BOLT - FLUSH MOUNT BRACKET CONNECTION DETAIL SCALE: I 1"=1'-0" REFER TO SCHEDULE THIS SHEET FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL CUT OUT OR REMOVE TILE TO INSTALL "LIFT KIT' ASSEMBLY. RE -INSTALL, RE -FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF MAT. SOLENE COLLECTOR TYP. SOLENE ALUMINUM MOUNTING BRACKET. , a ' DIA. ST STL LAG BOLT TYP . 0U SEE SCH FOR EMBED DEPTH REQ TYP. -� I SOLENE 3X3X$ - 4" ALUM.--,,, 6063T6 W/ 1" DIA. X i " 16 FLAT OR Ln I? INSERT "LIFT KIT" BARREL .� M WOOD TILE TYP of WI ; SHEATHING TYP. Ln I �I / �a Z — U Z .� #2 S.Y.P. WOOD ROOF W TRUSS TYP. TYPICAL FLAT TILE - BARREL 2 TILE ROOF CONNECTION DETAIL 6 SL-3 SCALE: 1 Z'=1'-0" SL-3 ROOF SHINGLES TYP. WOOD SHEATHING TYP. 'SOLENE COLLECTOR —\ SOLENE ALUMINUM MOUNTING BRACKE- ' IP,<\` 1r #2 S.Y.P. WOOD ROOF TRUSS TYP. 2X PT S.Y.P. WOOD OR WOOD SHEATHING ALUMINUM UNISTRUT T,P CONT. ALONG PANEL 8' DIA. ST STL ALL-THRD ROD WITH NUT - WASHERS MAX. T-0" O.C.-LOCTITE ALL NUTS TYP. ALL CONNECTIONS TYPICAL LIMITED SPACE OPTION CONNECTION DETAIL r4 SCALE: 12'=V-0" SL-3 ��#2 S.Y.P. WOOD ROOF TRUSS BEYOND S.Y.P. (2) 2X4 LOCATE BETWEEN �%�% TRUSSES WITH 4-16D NAIL PATTERN AT EACH END TO WOOD TRUSS TYP. g" DIA. ST STL LAG BOLT TYP. SEE SCH FOR EMBED DEPTH REQ TYP. REFER TO SCHEDULE THIS SHEET FOR REQUIRED �N EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL _v TYPICAL WOOD SPANNER OPTION FOR UNALIGNED TRUSS - BRACKET o ` CONNECTION DETAIL SCALE: 1 Z'=1'-O" SL_3°/ vll Oo m elf Lu 0 PROJECT: w z N w z p O Lu z 1 U _ Z O w Jfj Ocn p w ¢� .LL__ oEn w o0�N< t p w wcn .z o P o�tL ¢U z=a�LuLu w u z ne'� —ce O� V1 6? cna¢aa 8 o= DATE 1 1-10-18 h� Via= _ DRAWN BY: ]AT CHKDBY: ]AT REC. NO. # 29127 8 Na 30 �aW o� SCALE I AS NOTED DRAWING # g"o vv d JAN 2 3 2018 7"H i ii i M\\