Loading...
HomeMy WebLinkAboutENGINEERINGCONTRACTOR: Master Craft Aluminum DESIGN CRITERIA: - 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: V-T =150 MPH, V- =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure C 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1 - Patio Cover: Non -Habitable, -Unconditioned Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.032" Elite 2000 Composite Panel,1.0 # density foam, Florida Product Approval Number FL 7561-R4. Foundation Design Existing concrete. No additional -concrete footing or slab is required to resist the loads imposed by the proposed construction if the existing slab is a minimum 4" thick with an 8" x 8" thickened slab edge and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved. 4. Fasteners are required to be corrosion resistant,.minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300' ; or uncoated stainless steel series "400". 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or # 12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1% - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A6151 grade 60 ii. Welded wire fabric - ASTM Al85 c. Concrete slump at discharge. chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. £ Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Door location shall be determined by contractor in the field. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AN, .:kPOSURE HAVE BEEN DETERMI e USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. 'v Aii rN' -11S 0 A ACriM�NTS ARETR RESRON1 IBILfTY OF THE MITR.ACTOR OF RECORD 2X6SMB EDGE BEAM THESE PLANS AND ALL PROPOSED VIORI; ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO Comm V0H ALL ANUCAULA 3"X48"X0.032" 1.0# DENSITY FOAM COMPOSITE PANEL 6SMB GE BEAM /� ./ / • 2X3K.B. (TYP) / •/ / 3X3XO.093 / /• / POST SCANNED By 4 Lucie County 8'-81" -f COMPOSITE PANEL A-2 3X3XO.093 LO POST 3X3XO.093 POST B A-2 8'-11 a" 8'-11 in ST. LUCIE COUNTY BUILDING DIVISION FOR 000PLI. ,a RM11EWED BY DATE -(-/ PLANS AND PERP/IT MUST BE KEPT ON i06 OR NO IW!Pr--OTI'NJ WILL 13E MADE �f�- 9'-5" E ITF 2000 COMPOSITE PANEL: (FPA: FL7561-R4) 150MPH/EXP C 3"x48"xO.032" (1.0# DENSITY FOAM) MAX SPAN: q-q=14'-5' La ui OV a: a am o 0 � v W i"o cc Q m w t1 m W = W 0z Qz .11 Z x= O� W H W- LL Z , U S J L7 0 1zo -z m Ln cc U ra 'OLuLLnn"'0 Z ((D NN n Z'M� to LLI M u N VI tl! t]C w p o: O Q Z LL � 05LU Q N Lll 0) tY d oce)_ m aCO:;!LLLL DRAWN BY GD DATE DRAWN 01 /09/18 SHEET NO: A-1 ALUMINUM MEMBERS DIlVIENSII'_ HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.046" 2 x 3: 2" x 3" x 0.050" 2x4: 2"x4"x0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS lx2: 1"x2"x0.040" 1x3: 1"x3"x0.045" SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SUB: 2" x 4" x 0.044" x 0.100" 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" 2x7SMB: 2" x 7" x 0.05T'x 0. 120" '2 x 8 SMB: 2" x 8" x 0.072" x 0.124" 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" MINIMUM FASTENER EDGE DISTANCE: 1/2" MINIMUM FASTENER SPACING: 3/4" CONCRETE SCREW ANCHOR: SHAPSON TITEN HD OR EQUIVALENT SHEET METAL SCREWS (SMS): ITW / BUILDEX OR EQUIVALENT 3" x 3" x 0.093" 3" x 0.062" ALUM 2" x 2" x 3" x 1/e" ALUM ANGLE RECEIVING CHANNEL EACH SIDE OF UPRIGHT W/ #10 x 3W TOP AND W/ (1) 3/8" DIA, x 3" CONCRETE BOTTOM AS END CAP ANCHORS INTO CONCRETE AND (2) 318" x 4" THRU BOLTS B 3" x 3" POST TO DECK CONNECTION DETAILS A_2 SCALE: NTS 3" COMPOSITE ROOF PANEL >;r*i�;rs:'tr•"�i.::�:ly 'irw='pmaxs: 1 (5) #14 x 4 7/8" SMS W/ I 1 112" DIA. NEOPRENE EXISTING BUILDING FACED WASHER PER PANEL (3) 3/8" DIA. THRU BOLTS 2"x6"SMB 3"x3"POST �!, I S-, COMP. ROOF TO POST 4TH WALL DETAIL A_n SCALE: NTS (5) #14 x 4 7/8" SMS W/ 1 1/2" DIA. NEOPRENE FACED WASHER PER PANEL COMPOSITE *17 PANEL 3/8" DIA. RU BOLTS 2"x6"SMB 3" x 3" x 0.093" POST S COMPOSITE ROOF TO POST CONNECTION A_2 SCALE: NTS 3" COMP ROOF PANEL • • • 2" x 3" x 0.050" KNEE BRACE 1 1/2" x 2118" x 1 1/2" x 0.062" x 3" LONG ALUM RECEIVING CHANNEL W/ (3) #12 x 3/4" SMS EA. FACE & (3) #12 x 3/4" INTO POST BEAM S-2 KNEE BRACE CONNECTION DETAIL A_2 SCALE: NTS O p:,= 0. � CDI UJ w o a °'z= N� z i °_ 01. / A6b t di(mALSEAL � 0 ❑ OVw Li d d = z 0 CC v 0 8 oe c OC am -im w �2 LLI z z uJ �z Qz Z =m 0:3 w I- LL CC v± I`_ C Z u J J Z o N z^Om N OC H.88 S Q LIJ w , 91 T ui OLL1'i m m Z wmm z Z (D o M Z �ugJiS O N LLI (A N LLI co 0 O Q Z ILL �i°gLLJ LLI Lo 0 i N ul it M !L CM atJi DRAWN BY GD DATE DRAWN 01 /09/18 REVISION n _ SHEET NO: A-2