Loading...
HomeMy WebLinkAboutTYPICAL SCREEN ENCLOSURE DETAILS3' x 3' x 0.050' MIN, 6063-T6 ALLOY PLATE OR STRONGER CONE SIDE) WITH (3) - #12 x %i S.M.S, EACH SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) 3' x 2' x 0.050' MIN. 6063-T6 ALLOY PLATE OR STRONGER CONE SIDE) (3) - #12 x %'! S.M.S, EACH SIDE AS SHOWN OW MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) FOUNDATION BEAM OR SLOPED) CORNER POST EAVE RAIL - �,xI,�R�C BEAM STITCHING SCREWS (SEE TABLE) 2 24' O.C. I' x 2' O.H. (11 TOTAL) - #12 x S.M.S AS SHOWN C1�' MIN. SPLICE PLATE (EACH SIDE OF BEAM) A D O K I M PATIO SECTION PLATE EDGE DISTANCE & C-C FASTENER SPACING) SPACE SCREWS EQUALLY (TYP.) A A 5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS & ASSOCIATES, LLC 0 6' x 5' x 0.050' COLUMN m C CONSULTING o C a 6063-T6 ALLOY PLATE (ONE SIDE) OR STRONGER w ^ a STRUCTURAL K-BRACE A � oN ENGINEERS M 2x3xO.070 CHAIR RAIL �c Fa F cF r g C O PO Box 10039 K-BRACE Q Q Tampa, FL 33679 O Q O A �P1 #14xY'i SCREWS Tel: (813) 374-0321 K-BRACE Q ® P�`' j4% ``' (x) (WX) (rxx) (xx*x) Rev./Dat Description CORNER POST QQ ,`po '1 BEAM LINE LINE SCREWS 'A' 'H'&'C' TOTAL PLATE WIDTH ' (Syp3 ,AxylAp��5�1 0 7/2T 2015 ISSUED l3 cF�GR 2x4 3 2 F `e VANE g8S 15NA- 2x5 3 3 24 32 12' 14' � K-BRACE >by r+ `*1 „l `l r•� 2x6 4 3 GIRT (CHAIR RAIL) I3 U0 N l+e+t# 2x7 5 4 2x8 5 5 p�ZE 2x2x0.093 2x9 5 6 72118, BRAGEMP.), ROOF BEAM W) 6 7 1' x 2' OLE PLATE UNLESS OTHERWISE CONNECTION DETAIL E2xlO7 7 Q %' 0 CONCRETE ANCHOR <2 PLACES) IN LIEU OF TYP. 1/4' 0 CONCRETE SCREWS FOR CORNER COLUMN LATERAL "K" - BRACING CONNECTION DETAILS ate. 1x2 O.B. OR 2x2 FASTENED TO WA11�= 1" W/ #14x2" CONCRETE SCREWS 024" O C.- (OPTIONAL) 2x2 Y§' MIN. THICK ANGLE (EACH SIDE);; (ANGLE LENGTH = DEPTH OF BEAM);, (5)-#14x314- S.M.S. (EACH SIDE OF BEAM) HOST STRUCTURE ANCHORS EQUALLY SPACED (TYP.) I V c (2) Yi 0 x 2Yz" LONG WOOD LAG SCREW ORS lY (2) A'0 x 2Y4" LONG MASONRY ANCHORS�°'� t• HOST STRUCTURE (MASONRY OR WOOD) BEAM TO HOST STRUCTURE DETAIL IN SEE ELEVATIONS FOR 'K' BRACE SIZE (3) #12xYz" S.M.S., EACH LEG AND MIN. (4) #10x3" LONG S.M.S. INTO (6) #12x)5" S.M.S. CHANNEL TO M SCREW BOSSES (TYP.. ALTERNATIVE) BEAM (9) SCREW TOTAL CID STITCHING ®24" O.C. J (TYP. TOP AND BOTTOM OF SMB 2x3x0:OZ0%--1-_ SEE TABLE FOR SIZES) tzlx%" BY 2" LONG ��� ,,,!!! n� ANGLE, EACH SIDE (TYP.) \ 2x3z0.070 GLT/CHAIR RAIL \\ (SEE PLAN) 7 y �7-7-7-7 BRAKE-FORMED RECIEVING CHANNEL g> is (MIN. 0.062" MATERIAL THICKNESS) 1"x21/8"x 1"x3"LG. (TYP. ALTERNATIVE) MIN. (4) #10x2" LON \\ S.M.S. INTO SCREW OSSES (4) #14x1f" S.M.S., (TYP. ALTERNATIVE) �•� 2 SCREWS EACH LEG (TYP.) HOLLOW POST I ,—L i ,—L PURLIN TO ROOF BEAM CHAIR RAIL / GIRT TO POST CONNECTION DETAIL 2x3xO.045 EAVERAIL ATTACHED TO BEAMS WITH (3)-#10x2" S.M.S. 2x PURUN INTO SCREW BOSS. (2) #IOx4" S.M.S. THRU. 2x3 EAVE RAIL INTO PURUN SCREW2x5x.125 Y ANGLE-2" WIDE WITH BOSSES(2)-#14x1" INTO BEAM & (2)-.#114x1"- INTO UPRIGHT. x� USE #10x1)'x" S.M.S. ® 24" O.C.-TO CONNECT TO 1x2 O.B. TO 2x3. ® e 24'O.C. -�- USE #10x1)'2" S.M.S -TO CONNECT TO 1(2 O.B. TO 2x3. 1x2 O.B. FASTENED TO COLUMN/POST #10x11¢" S.M.S. INTO SCREW BOSSES) FASTENED TO COLUMN/POST!kp�LL..W/(2) #12x1" S.M.S. (EACH LEG) SIDE - OF BEAM 4(IYP.) (EACH END, TYP.)THICK FLAT BAR BENT �(6063-T6 OR�CH (6) #12x%AS.M.S. EACH SIDE ALLOY) OF BEAM F0�2x5 COLUMN TO 2x5 BEAM X"N/POSTS rn,,u,u ion SIDEWALL POST / COLUMN TO PURLIN CONNECTION DETAIL MAIN CONNECTION DETAIL UJ ci p c w O C) BY 3" LONG != Otx1x1(3" ANGLE, EACH SIDE (TYP.) J U (3) #124" S.M.S., EACH U Z LEG (6) TOTAL (TYP.) 0 LLI LLI N LLI C Z W O INN- U) Z U C) tL Cj) a U O DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN S.M.B. BEAM DATE: 8/11/06 ��� MAY BE SLOPED OR FLAT -7-;2'-.iSEE PLAN FOR SIZE) Yz' MIN., 3 Yz' MAX C-C SPACING OF FASTENERS (TYP.) W MIN. BEAM EDGE DISTANCE (TYP.) -t_..a )S-r -COLUMN rTO.ROOF B r'0NNFrTInKI nP:TAII 1 DO YEON KIM, P.E. FLA- REG. NUMBER 49497 DO KIM S OCIATES, LLC 6887 P 0 39 Tam a, FL 33679 q1v) Drawing No. - 060811 SHEET 1 OF 3 cuN� 3- MIN. (TYP.) Cl— I I % PURLIN SUPPORT COLUMN/POST )6" ANGLE, EACH SIDE (TYP.) B[A1,1 2x5x1¢' ANGLE <2' LONG) W/ (2)-414 2x2x1/8° x 2" LG. ANGLE W/ (4) #12x3/4° S.M.S S.M.S. WITH MIN.' EDGE DISTANCE �§"0 CONCRETE ANCHOR W/2%' EMBEDMENT INTO TEKS INTO TOP OF 2x3 EAVE RAIL AND (2)- f N14 TEKS INTO THE FRONT OF THE CORNER POST // D K I M (EACH SIDE) STRUCTURAL CONCRETE (TYP., EE NOTE 10) 6c ASSOCIATES, LLC %"0 CONCRETE ANCHOR O 1"x2' O.B. SOLE PLATE O O W/2%- EMBEDMENT INTO 2"x PURUN O STRUCTURAL CONCRETE CONS LTI N G (EACH SIDE) STRUCTURAL • "o.,' '= 1x2 O.B. TOP FRAME ENGINEERS ' 'a • •� •4 • ."ti' 2x2xJ(,' ANGLE CUP, GUT AT 1x3 O.S. FASTENED TO CORNER CORNER POST — A 45' (+/-) ANGLE AND SECTION WITH #110x2" S.M.S. W/ a w BEAM MAY ATTACHED TO THE SCREEN ROOF BEAM WITH ONE (1) Ys 0 THRU- %' DIA. WASHER ® 18" O.C. Po Box 10039 Ys Ox2%, CONCRETE SCREW ANCHOR O 24' O.C. BE FLAT OR SLOPED BOLT, WITH FENDER WASHER. 1x O.B. SIDE WALL CORNER UPRIGHT Tampa, FL 33679 p u u ao AND 9" FROM POST (TYP.) O ATTACHED TO BEAM OR EAVE RAIL DIAGONAL BRACING SHALL NOT BE Tel: 813 374-0321 ( ) y ATTACHED TO ROOF PURUNS. SIDEWALL COLUMN TO CONCRETE 9' COLUMN/POST 24 (SEE PLAN) 0.093 BRACE ELEVATION VIEW Rev./Dat Description Zo,s Issued CONNECTION DETAIL 5AL ix2 O.B. SOLE PLATE CORNER POST /COLUMN PLAN - TYPICAL DIAGOROOF O UPRIGHT DETAIL BRACE CONNECTION 0 1 - o SEE PLAN FOR, SIZE EDGE OF CONCRETE 1x2 O.B. FASTENED TO CORNER �y SECTION WITH S.M.S.® 24" D.C. F a wN^ ti PLAN VIEW 2x2x�' ANGLE 211LONG (EACH SIDE) rU> U�r ' W/(2) P1444 S.Y.S. TO POST zy� Cz & 3/8 0 H.D. GALV. EXP. BOLT i; a W/ 2 1/2' MIN. EMBEDMENT, CORNER POST / COLUMN _ TO CONCRETE -.-a`— -" -n" mod_ _'�ANGEE, EACH SIDE (TYP.) S.M.S. WITH MIN.' I� - EDGE DISTANCE %"0 CONCRETE ANCHOR W/2%" EMBEDMENT INTO STRUCTURAL CONCRETE (TYP., SEE NOTE 10) C ` 1"x2' O.B. SOLE PLATE � Ti 77 PA •• +43" MIN. (TYP.) �WE O 24" O.C. r f v AND 9" FROM POST (TYP.) ( Mz 11 COLUMN POST 1x2 O.B. SOLE PLATE — ® EDGE I' <TYP.) PLAN VIEW r V C MN=TO-CONCR CONNECTION DETAIL I' (TYP.) iu ' COLUMN 21¢' MAX. THICK BRICK PAVERS SET IN MORTAR ON TOP OF FOOTER +f CR 0.8. SOLE PLATE Z 04 1: 4•e'. 71..• ••ti' ., .. 2500 PSI MIN. CONCRETE STRENGTH :d C d .�` .III ° 4 III co 157 la II_ COMPACTED OR _ Q d, d II-1 UNDISTURBED SOIL/SAND — W v d II= —III (1)-#5 REBAR, CONTINUOUS I 3" MIN. CONC. COVER, 36" MIN. — W I I I -I III— I I-1 1I-1 I �TI� LAP SPLICE O � = o 12" MIN.* o J ZLU U MIN. CONTINUOUS PERIMETER FOOTING w (4) /)12A. 2"x PURUN BEAM MAY BE FLAT OR SLOPED C Z IX O U \ ' ao LLI � J V ALTERNATE (1) J W T 2x1xY" ANGLE V BRACE DRAWN BY: DYK CHECKED BY: DYK 2"xt"xJg" ANGLE (BRACE) W/ SCALE: AS SHOWN (4) #12x/4' S.M.S. ® EACH MEMBER INTERSECTION DATE: 8/11 /06 ' 2x2x%" ANGLE 2' LONG ON UNDERSIDEW/(4) 812x34" S.M.S. EACH LEG (BEAM & BRACE) PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 DO YEON KIM, P.E. 3RACE FLA. REG. NUMBER 49497 PLAN) ALTERNATE (2) DO KIM & IATES, LLC 2x3 BRACE C6 ABo PO1 39 TamL 33679 /j,Vli FOUNDATION/SLAB DETAIL Drawing No. - 060811 SHEET 2 OF 3 J- Genera! Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 3005-T53 Alloy, 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)410x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 5/16" 1/2" #12 0.219 3/8" 9/16" #14 (1/4") 0.250 V2" 5/8" 9. Structure has been designed to meet the V Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, V'dt, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASD). 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 I &, I "'V I ISSUED a Q tr cLLJ � o D U O � J � U � z � w `m w o z � . O a 1- J w a J Lu } U 0 � DRAWN BY. JS CHECKED BY: SCALE: SHOWN DATE: 8/11106 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM SOCIATES, LLC 26887 x 10039 T 33679 Drawing No. - 060811 I SHEET 3 OF 3