HomeMy WebLinkAboutSTRUCTURE PLAN"r l � ` DRAWING INDEX SHEET SHEET TITLE 01 GENERAL NOTES 02 STRUCTURE PLANS/ELEVATIONS 03 SUPPLEMENTAL DETAILS GENERAL NOTES A. DESIGN CRITERIA 1.0 REFERENCED STANDARDS 1.1 FLORIDA BUILDING CODE, 6TH EDITION 1.2 ASCE 7-10 1.3 ASTM SPECIFICATIONS FOR CONCRETE AND MASONRY 1.4 ACI 318-LATEST EDITION FOR STRUCTURAL CONCRETE 1.5 ACI 520-LATEST EDITION FOR MASONRY STRUCTURES 1.6 ADM 2015 1.7 AA ASM35, AA ADM 1 1.8 NATIONAL DESIGN SPECIFICATIONS FOR CONSTRUCTION DESIGN CODES AND GUIDELINES 2.0 DESIGN LOADS 2.1 DESIGN WIND SPEED PER F.B.C., CH. 16 LATEST EDITION Vult: 150 M.P.H. Vasd: 116 M.P.H. 2.2 RISK CATEGORY: 1 2.3 EXPOSURE CATEGORY: C 2.4 ALUMINUM LOADING: 2.4.1 DEAD LOADS: MEMBER SELF -WEIGHT 2.4.2 LIVE LOADS: 300 LB VERT. LOAD ON PRIMARY MEMBERS 200 LB VERT LOAD ON PURLINS 2.4.3 WIND LOADS PER F.B.C. TABLE 2002.4 (MWFRS) FOR 20x200.013" MESH SCREEN: HOR PRESSURE ON WINDWARD SURFACES: 43 PSF HOR PRESSURE ON LEEWARD SURFACES: 34 PSF VERT PRESSURE ON SCREEN SURFACES: 12 PSF VERT PRESSURE ON SOLID SURFACES: 36 PSF 2.4.3.1 FOR 18x14x0.013" MESH SCREEN, APPLIED FACTOR: 0.88 2.4.3.2 FACTOR APPLIED TO ALLOWABLE STRESS DESIGN PRESSURES: 0.6 2.4.4 RAILING LOADS PER FBC SECTION 1607.8 2.4.4.1 LINEAR LOAD ON HANDRAILS AND GUARDS: 50 PLF 2.4.4.2 CONC. LOAD ON HANDRAILS AND GUARDS: 200 LB 2.4.4.3 CONC. LOAD ON INTERMEDIATE RAILS: 50 LB 2.5 PRIMARY STRUCTURES 2.5.1 ROOF DEAD LOADS: 20 PSF 2.5.2 ROOF LIVE LOAD: 20 PSF 2.5.3 FLOOR DEAD LOADS: 40 PSF 2.5.4 FLOOR LIVE -LOAD: 40 PSF 2.5.5 BUILDING TYPE: PARTIALLY ENCLOSED GCpi =+/- 0.55 2.5.6 COMPONENT & CLADDING DESIGN PRESSURES (asd): ZONE I: +20.0 / -36.2 PSF ZONE 2: +20.0 / -46.2 PSF ZONE 3: +20.0 / -54.9 PSF B. RESPONSIBILITIES 1.0 A LICENSED CONTRACTOR SHALL PERFORM ALL SITE WORK IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2.0 CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISITNG FIELD CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF DEMOLITION, CONSTRUCTION AND/OR FABRICATION. THE CONTRACTOR SHALL VERIFY THAT THE HOST STRUCTURE/FOUNDATION IS IN GOOD CONDITION WITH SUFFICIENT STRENGTH TO SUPPORT PROPOSED STRUCTURE. THE ENGINEER OF RECORD IS TO BE CONTACTED IN WRITING FOR CLARIFICATION IF DISCREPANCIES ARISE. 3.0 THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS ASSOCIATED WITH WORK TO BE COMPLETED. THIS IS TO INCLUDE ALL SHORING AND/OR BRACING REQUIRED FOR COMPLETION OF PROJECT. 4.0 THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF COMPONENTS, FIXTURES, OPENINGS, AND LANDSCAPING ON THE SITE WHICH ARE NOT INCLUDED WITHIN THE SCOPE OF THIS PROJECT. IF DAMAGE OCCURS TO ITEMS NOT INCLUDED WITHIN THE SCOPE OF THIS PROJECT, THE CONTRACTOR IS RESPONSIBLE FOR RETURNING THAT ITEM TO ITS PREDAMAGE CONDITION. 5.0 THESE DRAWINGS AND DETAILS HAVE BEEN PREPARED AND ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND/OR MANUFACTURER. CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION IF SPECIAL SITE CONDITIONS ARISE FOR THE FOUNDATION OR HOST STRUCTURE. 6.0 1F PRE-ENGINEERED TRUSSES AND/OR JOISTS ARE CALLED FOR, THE DELEGATED TRUSS ENGINEER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO COMMENCEMENT OF CONSTRUCTION. MCGINN PROPERTY 3604 SPATTERDOCK LN., PORT ST. LUCIE, FL. 34952 C. MATERIALS 1.0 CONCRETE / FOUNDATION 1.1 SOIL l.l.I MIN. ALLOWABLE SOIL BEARING PRESSURE: 1500 PSF 1. 1.2 PRIOR TO CONCRETE PLACEMENT, TREAT ENTIRE SUBSURFACE FOR TERMITES IN ACCORDANCE WITH F.B.C. REQUIREMENTS FOR SUNROOMS. NOT REQUIRED FOR EXTERIOR SCREENED ENCLOSURES. 1.1.3 CONCRETE PLACED OVER A POLY VAPOR SHIELD WHERE APPLICABLE. 1.2 CONCRETE 1.2.1 ALL CONCRETE SHALL BE 3000 PSI MINIMUM. 1.2.2 CONCRETE SHALL CONFORM TO ASTM C94 FOR: 1.2.2.1 PORTLAND CEMENT, TYPE 1 - ASTM CI 50 1.2.2.2 3/4" AGGREGATE MAXIMUM - ASTM C33 1.2.2.3 AIR ENTRAINING, +/- 1%- ASTM C260 1.2.2.4 WATER REDUCING AGENT - ASTM C494 I.2.2.5 CLEAN POTABLE WATER 1.2.2.6 OTHER ADMIXTURES SHALL NOT BE PERMITTED 1.2.3 ALL SLABS ON GRADE SHALL BE 4" THICK MINIMUM 1.3 REINFORCEMENT 1.3.1 FIBERMESH (3/4" PER CU. YD.) MAY BE USED IN LIEU OF WELDED WIRE MESH IF APPROPRIATE ACI AND ASTM REQUIREMENTS ARE MET. 1.3.2 METAL WELDED WIRE MESH (WWM) SHALL CONFORM TO ASTM A185. 1.3.3 STEEL REINFORCEMENT SHALL BE ASTM A615 GRADE 60 WITH Fy = 60 KSI (U.O.N.) 1.4 PREPARE AND PLACE CONCRETE IN ACCORDANCE WITH ACI MANUAL STANDARD PRACTICE PARTS 1,2 & 3 ALONG WITH HOT WEATHER CONDITION RECOMMENDATIONS. 1.5 IF UTILIZING AN EXISTING SLAB/FOOTING, CONCRETE SLAB SHALL BE A MINIMUM OF 4" THICK AND VISIBLY FREE OF DETERIORATION, SPALLING OR EXCESSIVE CRACKING. CONTRACTOR TO VERIFY THAT EXISTING FOOTING IS A MINIMUM OF 12" WIDE AND 8" DEEP BELOW EXISTING SLAB. IF NOT, SEE FOOTING DETAILS FOR FOOTING DESIGN MINIMUM REQUIREMENTS. 2.0 ALUMINUM 2.1 ALL STRUCTURAL ALUMINUM SHALL BE 6005 T5 ALLOY MIN. 2.2 STRUCTURAL ALUMINUM DESIGN SHALL CONFORM TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE LATEST ALUMINUM DESIGN MANUAL. 2.3 PROV_IDE DIELECTRIC SEPARATION WHERE ALUMINUM COMES IN CONTACT WITH-STEEL-ORPRESSURE TREATED -LUMBER 2.4 ACTUAL WALL THICKNESS OF EXTRUDED ALUMINUM MEMBERS SHALL NOT BE LESS THAN 0.040 INCH 2.5 SELF -MATING BEAM SECTIONS TO BE STITCHED WITH #12 SMS SPACED AT 6" ON -CENTER FROM THE ENDS AND 24" ON -CENTER THROUGHOUT THE REMAINDER. 2.6 MINIMUM THICKNESS FOR FORMED SHEET ALUMINUM STRUCTURAL WALL PANELS (KICK -PLATES) SHALL BE 0.024". 2.7 18x140.013" MESH SCREEN SHALL BE USED UNLESS APPROVED BY THE ENGINEER OF RECORD. 2.8 ROOF BRACING SHALL BE A MINIMUM OF 2NT' 0.050" 2.9 DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 2.10 FOR PICTURE WINDOW MODIFICATIONS TO EXISTING SCREEN ENCLOSURES, THE CONTRACTOR SHALL VERIFY THE EXISTING SCREEN ENCLOSURE IS IN STRUCTURALLY SOUND CONDITION AND MEETS THE REQUIREMENTS OF THE DETAILS WITHIN THESE PLANS. 2.11 IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSUE SHALL MEET THE FLORIDA BUILDING CODE, RESIDENTIAL SECTION R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS IN ITS ENTIRETY. 2.12 SCREEN ROOM ALUMINUM ROOF SECTIONS (COMPOSITE OR PAN) SHALL BE SELECTED/DESIGNED FOR THE WIND PRESSURE STATED WITHIN THE WIND LOADS SECTION OF THESE GENERAL NOTES. THE SELECTION OF THESE ROOF SECTIONS WAS BASED ON THE SPAN TABLES PUBLISHED AND CERTIFIED BY INDEPENDENT FLORIDA LICENSED ENGINEERS WITH THE UP-TO-DATE N.O.A. 3.0 FASTENERS 3.1 ALL FASTENERS SHALL COMPLY WITH ASTM A153. 3.2 ALL CONCRETE SCEWS SHALL BE TAPCON, SIMPSON, HITLI, REDHEAD OR APPROVED EQUAL. 3.3 ALL LAG BOLTS SHALL HAVE A MIN. EMBED OF 8x BOLT DIA INTO STRUCTURAL FRAMING. 3.4 USE STAINLESS STEEL TYPE 300 18-8 FOR FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER, UNLESS OTHERWISE NOTED ON PLANS OR MANUFACTURER OF GALVANIZED BOLTS SPECIFIES FOR USE WITH ACE PRESSURE TREATED WOOD. SCANNED BY CONCRLED FASTENERS OR ATTACHMENTS I;t Lucie County AID THE RESRONSIBlu TyOFTHE CCNiNACTOROFRECORD 3.5 THE MIN CENTER TO CENTER SPACING FOR SMS SHALL BE 3/4" AND THE MIN CENTER TO EDGE DISTANCE SHALL BE 1/2" UNLESS OTHERWISE NOTED. 3.6 FOR Ix2 MEMBERS TO MASONRY/CONCRETE USE GALVANIZED 1/4"x2-3/4" TAPCONS OR SIMILAR AT 24" O.C. (T FILIM 3.7 FOR Ix2 MEMBERS TO WOOD FRAME USE #14x2-3/4" WOOD SCREW AT 24" O.C. (TYP.) 3.8 FOR Ix2 MEMBERS TO ALUMINUM USE #10xl-1/2" SMS OR TEK SCREWS AT 24" O.C. (TYP.) 4.0 STRUCTURAL LUMBER 4.1 ALL WOOD SHALL BE SOUTHERN YELLOW PINE 92 (U.O.N.) 4.2 PRESSURE TREATED STRUCTURAL LUMBER SHALL ONLY BE USED IN EXTERIOR APPLICATIONS AND IN CONTACT WITH CONCRETE, MASONRY OR EARTH. PRESSURE TREATMENT SHALL BE CALLED OUT AS P/T WITHIN THESE PLANS. 5.0 CONCRETE MASONRY 5.1 THE AGGREGATE MININMUM NET AREA COMPRESSIVE STRENGTH OF THE BLOCK AND MORTAR SHALL BE fm = 1900 PSI. 5.2 CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C90, NON -MOISTURE CONTROLLED. 5.3 MORTAR SHALL CONFORM TO ASTM C270, TYPE'NT OR'S'. 5.4 INSPECTION PORTS SHALL BE PROVIDED AT ALL FILLED CELL DOWNPOUR LOCATIONS. 5.5 U.O.N, HEAD AND BED JOINTS SHALL BE 3/8" THICK EXCEPT THAT THE BED JOINT THICKNESS OF THE STARTING COURSE OVER FOUNDATIONS SHALL BE NOT LESS THAN 1/4" THICK AND NOT MORE THAN 3/4" THICK. P�\11111 .l\ ,�5W! P�786 S?AT5 0 FLOF SIO N /lih THESEPLANS AND ALL PROPOSED WORK f ARE SUBJECT TO AW CORRECTIONS REQUIREDBY H�EW ¢INSPECTORS THAT 5.0 WINDOWS AND DOORS tk=d15�iY�eLi1�7998'!Y'.BE�^�7I1A�T�_ 5.1 THE WINDOW AND DOOR ASSEMBLIES SHALL BE SELECTED/ /�'q?4 y �q DESIGNED FOR THE WALL DESIGN WIND PRESSURE STATED 'C&A�L'I MH F 11 T ,I1.�-14p g"UXDESI ` WITHIN THE WIND LOADS PORTION OF THESE GENERAL NOTES. - - 5.2 WINDOWS AND DOORS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 5.3 EXTERIOR WINDOWS AND GLASS DOOR SHALL BE TESTED BY AN APPROVED INDEPENDENT TESTING LABORATORY, AND BEAR AN AAMA OR WDMA OR THER APPROVED LABEL IDENTIFYING THE MANUFACTURER PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF THE FOLLOWING SPECIFICATIONS: ANSI/AAM/NWWDA 101/I.S 2-97 5.4 A SUPPLEMENTAL TERMPORARY LABEL CONFORMING TO AAMA 203, PROCEDURAL GUIDE FOR WINDOW INSPECTION AND -NOTIFICATION SYSTEM SHALL BE ACCEPTABLE FOR ESTABLISHED CALCULATED ALLOWABLE DESIGN PRESSURES HIGHER THAN INDICATED ON THE LABEL REQUIRED BY 1707.4.2.1 FOR WINDOW SIZES SMALLER THAN THAT REQUIRED BY THE ANSI/AAMA/NW WDA 101/IS2 TEST REQUIREMENTS. THIS SUPPLEMENTAL LABEL SHALL REMAIN ON THE WINDOW UNTIL FINAL APPROVAL BY THE BUILDING OFFICIAL. ALUMINUM EXTRUSION DIMENSIONS SNAP SECTIONS 2x2 2"x2"x0.045" 2x3 2"x3"x0.050" 2x4 2"x4"x0.045" SNAP PLATE: HR-2 1.7950.050 CHANNELS: 1.5"x2. l 25"x 1.5"x0.045" 2"x3.125"x2"x0.045" PICKETTS: V TUBULAR/HOLLOWx0.050" TOP CAPS: HR-1 2.5x1.6250.050 HR-14 1.964x 1.482x0.050 BOTTOM CHANNEL: 1 "x l .5 "x0.050" POST CHANNEL: 1.5"x1.5"x0.050" 2"x2"x0.050" ST, LUCIE COUNTY! I3UILDINQ DIVISION REVIEWED FOR. COMPLI REVIEWED BY DATE 62.21 PANS AND PERM MUST BE KEPT ON J OR NO INSPECTION WILL BE MADE ALUMINUM EXTRUSION DIMENSIONS HOLLOW SECTIONS 2x2 2"x2"x0.050" 2x3 2"x3"x0.050" 2 x 4 2" x 4" x 0.050" 2x5 2"x5"x0.050" OPEN -BACK SECTIONS Ix2 1"x2"x0.044" l x 3 1" x 3" x 0.045" SNAP SECTIONS 2x2 2"x2"x0.045" 2x3 2"x3"x0.050" 2x4 2"x4"x0.045" SELF -MATING SECTIONS (SMB) 2x4 2" x 4" x 0.044" x 0. 100" 2x5 2" x 5 " x 0.050" x 0. 118" 2x6 2" x 6" x 0.050" x 0. 120" 2 x 7 2" x 7" x 0.057" x 0.120" 2x8 2" x 8" x 0.072" x 0.224" 2 x 9 2" x 9" x0.082" x 0.224" 2 x 10 2" x 10" x 0.092" x 0.374" azQ.�iiw a¢z�� Q �p�nm� 1UZ-!f3 J N M I v p: I (941) 456-7535 e: admin@southsunengineering.com w: www.southsunengineering.com CONTRACTOR: TREASURE COAST HOME IMPROVEMENTS, INC. PROPERTY ADDRESS: 3604 SPATTERDOCK LN., PORT ST. LUCIE, FL. 34952 DATE: 12/6/2017 PROJECT NO: A1702301 Sol INI �mI EXISTING SCREEN ROOM NO WORK EXISTING 9 1 SHED TO c 110'-0" X REMAIN N I N 1 2 S 00 0o 110 -0 ADJACENT N N I MOBILE HOME 2X4SMB 1 A I N N 1 I 2X4SMB I A� I I 110'-0" N N I 2X4SMB I 12'-0" A INDICATES 3X3X.125 ALUM. POST (TYP.) B 3"-.032-1LB COMPOSITE PANELS 3105-H14-- [1/4" PER 1' MIN. SLOPE] CONCRETE SLAWFOUNDATION �72 50AL'^8'-81,'NAL X8'-0E X M M M -�— 12'-0" —i ELEVATION A NEW ROOF Q z O N u 7- 0 W F a' > rTl �w s d 144 "I/, PE 7 z * xFzu' ¢c y STATE CF z �10 V u FH3� EXISTING ROOF - -0 cr YPICAL DIAGONAL BRACE Mcl , X -..STINGN�4 SHED8TY2�X3X.050 TO REMAIN I— -- 10'-0" — — 8'-6" ---- 10'-01, ----t--- 10'-0" —I ELEVATION B �— NEW ROOF T EXIST G ROOF - 2X7SMB 2X7SMB 2X7SMB 2X7SMB - 2X3X.050 TYPICAL �, N v 8'-8" 7 DIAGONAL X X X BRACE M M X M __---- M _—_—_M----_-----_--_—M �— 10'-0" —�--- 8'-6" 10'-0" ---f 10'-0" -----I ELEVATION C i nESE PLANS AIND ALL PRUOPOSE'D WOR ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT y; AY EE NECF.K- RT Iil 0RCER-TO w "L j)PLICAN CODES:' UQ w ua w ar � Z. ` ! r- M x P.cn \ v� W M � H W �O � W Na P: (941)456-7535 e: admin@southsunengineering.com w: www.southsunengineering.com CONTRACTOR: TREASURE COAST HOME IMPROVEMENTS, INC. PROPERTY ADDRESS: 3604 SPATTERDOCK LN., PORT ST. LUCIE, FL. 34952 DATE: 12/6/2017 PROJECT NO: A1702301 STRUCTURE PLAN SCALE: 1/8" = P-0" S02 j lI COMPOSITE PANELS PER PLAN FASTEN PANELS TO BEAM 4-1 W/#12X4"SMS W/ 1-1/2" NED WASHER AT BEAM PER PLAN -NOTCH COLUMN TO RECEIVE BEAM FASTEN W/(3) 3/8" HEX BOLTS COLUMN PER PLAN I COLUMN/BEAM/COMPOSITE PANEL CONN 03 SCALE: N.T.S. PROVIDE 1/8" INTERNAL CHANNEL CUT TO FIT W/ NO SLIP TOLERANCE. FASTEN TO COLUMN WITH (2) 3/8" HEX BOLT -NUT AND LOCK WASHER OR LOCKING NUT -ALTERNATELY FASTEN W/ #14x9/16" SMS (3) EA SIDE -FASTEN TO CONCRETE W/(4)3/8"X4" TAPCON OR EQUALFOR WOOD USE 1/4 X2-1/2" GALV LAG SCREW IN LIEU OF MASONRY ANCHORS PROVIDE I/8"x 2" x2" ANGLE EA SIDE. FASTEN TO CONCRETE W/ (2) 3/8"x 4" TAPCON EACH SIDE FASTEN TO COLUMN W/ (2) 3/8" HEX BOLT -NUT AND LOCK WASHER OR LOCKING NUT. ALTERNATELY FASTEN TO COLUMN W/ 414x9/16" SMS (3) EACH SIDE- FOR WOOD USE I/4.._I 2" GALV LAG SCREW IN LIEU OF MASONRY ANCHORS _ SIDE VIEWS TOP VIEWS /_2 ALTERNATE BASE ATTACHMENT DETAILS 00 SCALE: N.T.S. 24"(MIN) BEAM PER PLAN 24" (MIN) z zc""'/w FASTEN BRACE TO COLUMN AND BEAM W/ .044 RECEIVING CHANNEL. FASTEN CHANNEL TO BEAM AND COLUMN W/ (3) #12x5/8" SMS (INTERNAL). FASTEN CHANNEL TO BRACE W/# 12x5/8" SMS-(3) PER SIDE -SEE PLAN :EIVING CHANNEL CUT TO M SIZE -FASTEN TO COLUMN IAL) W/(6) 412X5/8"SMS I BEAM TO CHANNEL EACH 912SMS QUANTITY = BEAM SS(I) 2X7 BEAM USE (7-1=6) 5/8"SMS EACH SIDE 4 BEAM TO COLUMN ATTACHMENT • 03 SCALE: N.T.S. #12X4"SMS W/1-1/2"NEO-WASHER - THROUGH PANEL AND ANGLE AT 12" O/C i COMPOSITE PANEL I I I 1 2"x2"xl/8" CONT. ANGLE. I SCREW ANGLE TO BEAM ' W/ 914X3/4" SMS @ 12" O/C BEAM PER PLAN NOTCH COLUMN TO RECEIVE BEAM ATTACH BEAM TO COLUMN W/(2)3/8" THROUGH BOLTS Ccl Q z 0 w LYi 3"X3"X.125 SPACER LOCATED AT TOP AND BOTTOM OF PLATE -FASTEN TO PLATE W/#12X5/8"SMS (2) EACH SIDE 1/8" PLATE EACH SIDE -FASTEN THROUGH COMPLETE ASSEMBLY W/(6)3/8" THROUGH BOLTS CUT TO FIT 12" MAX OFSET _ 3/8" THROUGH BOLT THROUGH EACH BRACE 5 OFFSET BRACE DETAIL AT 4TH WALL 03 SCALE: N.T.S. T PS 74 _-D HOrAcn ° oQi�Uiz v` U O j �0: STA JR OR I D on`� ��' w . lllill �QF.,W�� t 4 rig • . w ►'t iffs ARE SURJECALL PROPOSED. ' hK Tp � REQUIRE® By i A CC)R ECTIONS SPE ®RS �bAT ®;IL1y� '��R���q' I1 oRC-R Tow '�A"?, Pt it fit .�t �mg ••c� H �M M H � Wo F W. Z u �n� m �( W�O Na P: (941) 456-7535 e: admin@southsunengineering.com w: www.southsunengineering.com CONTRACTOR: TREASURE COAST HOME IMPROVEMENTS, INC. PROPERTY ADDRESS: 3604 SPATTERDOCK LN., PORT ST. LUCIE, FL. 34952 DATE: 12/6/2017 PROJECT NO: A1702301 r_3_"� DIAGONAL BRACING 03 SCALE: N.T.S. S03