Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SCHEMATIC SITE PLAN 7-19-21
AIp QQT�• o®®®®a < M-M =C I Co C-oW�ma.7 N� <m oN 611Ar1O a-_On I Y,'1 TPEg f m ow SO Oo0(n In\- w m��o 0 oaD In 4O.0=09am m m o^1D m Z m m nm•n �c� or 0"c �c a^m LA o -.o" PAT " I 'oxm�`° 0 ^ 9^0 Ana S ^ -•- m-•nJ, rL++a m _r.l co m 0 LSY3 99 3D" WDS W cPH5401. Z£ NOU33S JO 31111153M 0 J Ofmm W O ] N WW o � 0 m m n _ e m ^ n m u0i Z � O y y m a am IN ,9ilLl 3 SZ,01A0 S o ;10 EXISTING TRAILER Ln 0 nm-1 CAR PORT r D m 1= VETAL BUILDING �"• /9' `, O X N V m A? 1 -+ : 71 W mT .• o u93mea 3aaL 493INd 30611q J f{ro 33N1J X (�),l5'OOf9 L � N -I m 5 �m ;o00 cn N @ Cn M NCn D fn z CD '� -n p, _ _m 0 n 0 D � <_ 0 _ �N Da o �' 1 7 3 v C- = c [] Fri w 1 m A I V C 11 N 12' 0 COLLAR TIE FRAMES ALL FRAMING MEMBERS 2 1/2"x2 1/2"x129a GALV. STEEL FRAMES AT 4C. O.C. BRACING @ 10'-6" O.C. STORAGE ENCLOSURE BEYOND 2 1/2" x 2 1/2" x 1/4" CONT. BTM. TUBE W/ 3/8"x5 1/2" POWERS WEDGE BOLTS 42" O.C. 8"W x 18"D x CONT. CONC. CURB W/ (2)#5 CONT. SECTION / SOUTH ELEVATION A -A SCALE: 1 /4"=V-0" t42' V.I.F. t7' V.I.F. o e �-- 3 x 6 DOOR TT 8"W x 18"D x CONT. CONC. CURB W/ (2)#5 CONT. 22' x 49' CAROLINA CARPORT (BY OTHERS) � OPEN C — A FRAMES @ 42" O.C. CARPORT FOUNDATION PLAN SCALE: 1/8"=1'-0" 10'-0" 2x4@24" O.C. W/ METAL SIDING 4" CONC. SLAB W/ 12"x12" MONO FTG. q W/2-#5 CONT. ( 2 �2 x 20 S.H. WINDOW LL— r z-1 / 77- 1 77 �3 x 6' DOOR MANUF. SHED PLAN SCALE: 1 /4"=1'-0" MANUF.SHED BLDG.W/ BASE PLATE FASTEND W/ 3/8"x4" POWERS WEDGE BOLTS @32" O.C. TRUSS ROOF W/ TAPPERED METAL PANEL ROOF N II 6"x16GA METAL FRAMING @24" O.C. (TYP.) W/ METAL SIDING STORAGE ENCLOSURE IrIr jrl+ . I� II SIMPSON H3 ALL WOOD TO WOOD CONNECTIONS U.O.N. /B 1r (2))2x6 CONT. ® PERIMETER 1 (�)16d2NAILS EACH POST 2x6 BRACE EA. WAY EACH CORNER I I I I I I I of I I I I I I I I I I I ®I I I I I I co M AL DE K OVE 2x4 4" O.C. W #12x2' S REWS 24" .C. (TEK I I I I I (RIDGE (RIDGE I I 12X8 2X8 RIDGE 2Xfi _ BU O I I I I I I I I I I I ®I POLE BARN FRAMING PLAN SCALE: 1/4"=V-0" a POLE BARN PLAN SCHEMATIC SITE PLAN 5o GRAPHIC SCALE o ( IN FEET ) 1 inch = 50 ft EXISTING AERIAL VIEW N.T.S. rvvuvur, on�u METAL DECK OVER 2x4@24" O.C. W/#12x2" TEK SCREWS @ 24" O.C. �I— SEE PLAN FOR FRAMING —� SIZE & SPACING I i i �.-- METAL SIDING OVER 2x4 @ 32" O.C. *12x2" � #12x2TEK SCREWS @24" O.C. I 4x4 POST @ 5' O,C. 14"0 x 24" D CONC. FTG. TYP. GRADE BARN SECTION B-B REVISIONS I BY ':� cc co co W c\jto 1 Cco /c e0 Cc 7� •' 1\' _ 0 ko w p O O� � U a w W U �4 W x� O U � W EF W SCANNED Q StLUCP�P,� Gounfy O [~ O ,D CIO V J oc F.B.C. 2020, 7TH EDITION ASCE-7-16 EXP. 'C' 170 MPH (ULT.) RISK CATEGORY II 3000 PSI CONCRETE ACI CODE AISC CODE (36 KSI STEEL) LUMBER SYP #2 OPEN STRUCTURE: +37.9 PSF -50.7 PSF DATE 7.7.2021 FILE TOMTW DRAWN SCALE: SHEET # 0 a w E- I w 1 of 1 N ELECTRICAL PANEL NOTES 1) SMOKE DETECTORS SHALL BE INSTALLED AHEAD OF ALL SWITCHES AND SHALL BE CONNECTED TO BATHROOM OR KITCHEN LIGHTING CIRCUITS. SMOKE DETECTORS SHALL BE U.L. LISTED AND MEET THE REQUIREMENTS OF NFPA 74 AND NFPA 72-E. 2) THE PANEL SCHEDULE SHOWN ON THIS PLAN IS ONLY FOR BREAKER SIZE REQUIREMENTS, WIRE SIZE, LOADS, AND NUMBER OF CIRCUITS REQUIRED. ACTUAL SEQUENCE AND DESCRIPTIONS SHALL BE PLACED ON INSIDE PANEL COVER BY ELECTRICAL CONTRACTOR. 3) SMOKE DETECTORS SHALL BE POWERED BY HOUSE ELECTRICAL SERVICE W/ BATTERY BACK-UP. 4) MULTIPLE DETECTORS SHALL BE INTER -CONNECTED. FAULT CURRENT FROM SECONDARY TERMINAL OF MAXIMUM TRANSFORMER SIZE OF 75 KW IS EQUAL TO 26, 194 SYMMETRICAL AMPERES AT 120/240 VOLTS AS PROVIDED BY FLORIDA POWER AND LIGHT COMPANY AT WORST CASE, A 1/0 ALUMINUM SERVICE WIRE FOR A DISTANCE OF 38 LINEAL FEET PRODUCES AN AVAILABLE FAULT CURRENT OF 9848.94 AMPERES. NOTE: 1.75% OF INSTALLED LIGHTING FIXTURI SHALL HAVE HIGH EFFICIENCY LAMPS. 2.RECESSED LUMINAIRE INSTALLED IN NUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED & UN -CONDITIONED SPACES. THE HOUSING CANS SHALL BE LISTED IC -RATED IF IN CONTACT WITH THERMAL INSULATION GENERAL NOTE: ELECTRICAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO CONSTRUCTION. ELECTRICAL SERVICE NOTE 1. ALL ELECTRICAL SERVICE EQUIPMENT SHALL HAVE MIN A.I.C. RATING OF 10,000 AMPS AND SHALL BE NEMA-3R RATED. 2. ALL ELECTRICAL EQUIPMENT AND WIRE SHALL BE RATED 0 75°C CONTINUOUS DUTY. 3. PRIOR TO CONSTRUCTION. THE ELECTRICAL CONTRACTOR SHALL: a) VERIFY ALL EXISTING CONDITIONS IN FEILD b) COORDINATE THE ELECTRICAL SERVICE WITH FP&L REPRESENTATIVE AIR CONDITIONING EQUIPMENT AND CONTROLS SPECIFICATION 1.ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONTROL RACEWAY (CONDUIT), WIRE INSTALLATION, CONNECTIONS ETC. IN ACCORDANCE WITH WIRING DIAGRAMS ON AIR EQUIPMENT. 2.A/C / ELECTRICAL PLANS OR DIAGRAMS FURNISHED BY MANUFACTURER OF THE EQUIPMENT. 3.ALL POWER WIRING FOR THE AIR CONDITIONING EQUIPMENT SHALL BE FURNISHED, INSTALLED AND CONNECTED UNDER THIS SECTION OF THE SPECIFICATION. CMECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTERS FOR ALL AIR CONDITIONING EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONNECTIONS TO AIR CONDITIONING EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. S.AIR CONDITIONING EQUIPMENT INCLUDES CONDENSOR, COMPRESSOR AND FAN, FAN COIL UNITS, ELECTRICAL STRIP HEATER, THERMOSTAT, ETC. LIGHTING NOTES I. LOW VOLTAGE • ELECTRICAL CONTRACTOR TO VERIFY IF ANY LIGHTING FIXTURES REQUIRE STEP-DOWN TRANSFORMERS. QUANTITY AND LOCATION OF THE TRANSFORMERS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION. 2. ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY CONTRACTOR ELECTRICAL NOTES 1. ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 1S- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED ;'( _• `:;� ".a" _ BY A COMBINATION TYPE ARC -FAULT CIRCUIT INTERRUPTER INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. A DUAL FUNCTION AFCl/GFCI CIRCUIT BREAKER IS ACCEPTABLE IN LOCATIONS REQUIRING BOTH GFI AND AFCI PROTECTION. 2. ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL SIMULTANEOUSLY W/ TEMPORAL SOUND. SMOKE DETECTORS TO BE LOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS, KITCHENS, BATH ROOMS. 3. ALL LIGHTING FIXTURES AND FANS TO BE SELECTED BY OWNER, UNLESS OTHERWISE NOTED. 4. OWNER TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE APPLICABLE, UNLESS OTHERWISE NOTED. 5. NOT USED 6. FOR FLOOR RECEPTACLES, PROVIDE A BRAGS COVER PLATE AND FLUSH WITH FLOOR. VERIFY EXACT LOCATION WITH GC/OWNER: PROVIDE 1/2"C UNDERSLAB FROM WALL. 7. CABLE TYPES NM, NMC OR NMS MAY BE U9EO WHERE CONDUIT IS NOT REQUIRED. 8. BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT. 9. PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "I" BOXES. 10. NOT USED 11. NOT USED 12.VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL AHU'S AND CU's WITH MECHANICAL CONTRACTOR 13.A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET SHALL BE PROVIDED AT OR NEAR THE APPLIANCE LOCATION IN ACCORDANCE WITH NFPA 70. 14.VERIFY EXACT LOCATIONS OF ALL KITCHEN EQUIPMENT WITH OWNER PRIOR TO CONSTRUCTION. VERIFY ALL ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION. 15.LIGHTING IN CLOTHES CLOSETS MUST COMPLY WITH N.E.C. 4.1O.B/D/1 THRU 4. 16.TAMPER-RESISTANT RECEPTACLES SHALL BE PROVIDED THROUGH DWELLING UNIT. ELECTRICAL SPECIFICATIONS 1. DO NOT SCALE THE ELECTRICAL DRAWING. REFER TO THE ARCHITECTURAL PLAN AND ELEVATIONS 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2017 EDITION OF THE F.B.C. 2011 EDITION NATIONAL ELECTRICAL CODE AND 2012 EDITION OF NFPA 101. 3. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER. INSULATION SHALL BE 90° C THHN / THWN FOR ALL SIZES. ALL CONDUCTORS #12 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #10 AND LARGER SHALL BE STRANDED. ALL CONDUCTORS EXPOSED TO DAMP OR WET LOCATIONS SHALL BE LISTED FOR USE IN DAMP OR WET LOCATIONS. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUN, QUICK MAKE, QUICK BREAK, WITH ENCLOSURES AS REQUIRED BY EXPOSURE. 6. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250, NATIONAL ELECTRICAL CODE. B. ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS WHERE APPLICABLE. 9. ALL WORK SHALL BE PERFORMED BY A LICENCED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANSHIP MANNER, THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENGINEER/ARCHITECT MUST BE A CONDITION OF THE SUBCONTRACTOR. 10. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER, LIGHT COMPANY AND TELEPHONE COMPANY. 11. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT JOB CONDITIONS. 12. SEE NOTES ON PLANS FOR OTHER REQUIREMENTS. 13. NOT USED 14. AU. WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 15. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY PHASE OF THE INSTALLATION WHICH MAY BE DAMAGED. 16 ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 17. CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT BEFORE CONNECTION TO CIRCUITS. 18. ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIED OR INTENDED AND REVISE BRANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OF GC. 19. PADDLE FAN JUNCTION BOXES SHALL BE LISTED FOR USE WITH PADDLE FANS BY THE MANUFACTURER. WEIGHT LIMITS NOT TO EXCEED 70 LE S. 20. ALL GFI OUTLETS MARKED AS'WP' SHALL HAVE A WATERPROOF ENCLOSURE PER NEC. ELECTRICAL LEGEND SA SMOKE ALARM HARDWIRE WITH BATTERY BACKUP DUPLEX RECEPTACLE SWITCH n 4 TELEVISION JACK © COMBO SMOKE ALARM 002 ALARM HARDWIRE WITHBATTERY AFCI AT 12'A.F.f iYP. U.N.O. ARC FAULT SINGLE POLE PREWIRED BACKUP (� DUPLEX RECEPTACLE SWITCH ® DEDICATED RECEPT. SWITCH G CI GROUND FAULT ] THREE WAY AT 12" A.F.F. (220 V) DISCONNECT ($( DUPLEX RECEPTACLE SWITCH HVAC OF PRE -WIRED SWITCH AND A� TOP REC. SWITCHED 4 FOUR WAY O THERMOSTAT ]-BOX FOR FAN OPTION ,}�, WP/GFCI GROUND FAULT DUPLEX RECEPTACLE TELEPHONE OUTLET FLUORESCENT LIGHT FIXTURE ELECTRICAL METER WATERPROOF AT 12" A.F.F. CaF•P•L. Q PUSH L.E.D. SECURITY L.E.D. LIGHT BREAKER BUTTON LIGHTS FIXTURE CLG. MINTED. PANEL duc DUPLEX RECEPTACLE ® L.E.D. MINI HI HAT L.E.D. LIGHT EXHAUST AFCI UNDER COUNTER ARC FAULT FIXTURE WALL. MNTD. FAN GROUND FAULT DUPLEX RECEPTACLE DOOR L.E.D. HI HAT LED STRIP LIGHT - C/GFCI ABOVE COUNTER CH CHIMES CLG. MOUNTED MNTD. UNDER CAB. Q CO2 ALARM HARDWIRE WITH BATTERY BACKUP FAN / L.E.D. LIGHT ® L.E.D. HI HAT 0 L.E.D. LIGHT BAR MOUNT 60" AFF VP VAPOR PROOF (3) 2/0 COPPER 1#6 GREEN IN 2" PVC METER 200 AMP 1 � PANEL 200A RAIN BREAKER AIC RATING FOR MAIN O DISCONNECT 10,000 42 CIRCUIT 1� #2 COPPER THHN IN SCH 80 PVC CONDUIT GNO ELECTRODE FPL GROUND ROD TIED TO SLAB STEEL GRADE 0 ELECTRICAL RISER DIAGRAM GFCI 42" AFF �. L- � - - - L - - - _ _ - - -� - - - I - - - - -- - _ / GFCI 42" \ / GFCI 42" AFF AFF / I � �--.-.--� GFCI 42" SS / GFCI 42" AFF / . AFF JAESS /- _.. - GFCI 42" AFF / AFF 7 0 011 o 00 - - - - - - - - -- - ---- o0 00---------- - 0o �"---------- _------ ---.---- .-- _ ELECTRICAL PLAN SCALE: 1/4" = V-0" l(11iffie ffam EXISTING GARAGE ELECTRIC PNLA 200 A EXISTING GARAGE rich itectu ra I onsultants nc. ARCHITECTURE / DESIGN Lic. No. 26002046 2475 MERCER AVE. SUITE 201 West Palm Beach, FL 33401 Phone 561-655-0674 RENOVATIONS TO GARAGE 16142 EAST BURNS DRIVE, LOXAHATCHEE, FL. CONTRACTOR AND ALL SUBCONTRACTORS PERFORMING ANY WORK ON THIS PROJECT ARE TO VISIT THE SITE AND VERIFY ALL MEASUREMENTS INCLUDING BUT NOT LIMITED TO BUILDING HEIGHTS, ROOF SLOPES, ROOM DIMENSIONS ETC. TO CONFIRM ALL EXISTING CONDITIONS BEFORE ORDERING OR FABRICATING ANY MATERIALS. CONTRACTOR SHALL REPORT ANY INCONSISTENCIES WITH THE CONSTRUCTION DOCUMENTS TO THE ARCHITECT BEFORE CONTINUING WORK. REV # DATE DESCRIPTION SEAL ROGER HANSROTE, ARCHITECT FLAR # 14300 JOB NUMBER: 2020-41 DATE:06-02-2020 DRAWN BY: JP APPROVED BY: RH SHEET TITLE SHEET NUMBER PERMIT ISSUE 06-29-2020 A4n 0