HomeMy WebLinkAboutSITE PLAN 7-19-21AIp QQT• o®®®®a
M-M C I Co C-oW
ma.
7
N
m
oN
611Ar1O
a-_OnI Y,'1TPEgfmowSOOo0(n In\- w mo0oaDIn
4O.0=09ammmo^1D m Z
m m nm•n c or 0"c c a^m LAo -.o"
PAT
I 'oxm`° 0 9^0 Ana Sm-•nJ, rL++a
m _r.l co m 0 LSY3 99 3D" WDS W cPH5401.
Z£ NOU33S JO 31111153M
0J Ofmm W
O ] N
WW
o
0 mmn _ e
m
n
m
u0i
Z O
y y m
a
am IN
9ilLl 3 SZ,01A0 S
o ;10 EXISTING TRAILER
Ln 0
nm-1 CAR PORT
r D
m 1=
VETAL BUILDING "•
9'
O X
N
V
m A?
1
71
W mT .•
o
u93mea 3aaL
493INd 30611q J
f{ro 33N1J
X
l5'OOf9
L
NI m
5 m
o00
cn
N@ Cn
M NCn D fn
z
CD
n
p, m 0
n 0 D 0
N Da o
1 7
3 v
C- cFri
w 1 m
A I V
C
11
N
12'
0
COLLAR TIE FRAMES
ALL FRAMING MEMBERS 2 1/2"x2 1/2"x129a GALV. STEEL
FRAMES AT 4C. O.C.
BRACING @ 10'-6" O.C.
STORAGE ENCLOSURE BEYOND
2 1/2" x 2 1/2" x 1/4" CONT. BTM. TUBE W/
3/8"x5 1/2" POWERS WEDGE BOLTS 42" O.C.
8"W x 18"D x CONT. CONC. CURB
W/ (2)#5 CONT.
SECTION / SOUTH ELEVATION A -A
SCALE: 1 /4"=V-0"
t42' V.I.F. t7' V.I.F. o e
3 x 6 DOOR
TT
8"W x 18"D x CONT. CONC. CURB
W/ (2)#5 CONT.
22' x 49' CAROLINA CARPORT
BY OTHERS)
OPEN
C —
A FRAMES @ 42" O.C.
CARPORT FOUNDATION PLAN
SCALE: 1/8"=1'-0"
10'-0"
2x4@24" O.C.
W/ METAL SIDING
4" CONC. SLAB
W/ 12"x12" MONO FTG. q
W/2-#5 CONT. (
2
2
x 20 S.H. WINDOW
LL— r z-1 / 77-
1
77
3x 6' DOOR
MANUF. SHED PLAN
SCALE: 1 /4"=1'-0"
MANUF.SHED BLDG.W/
BASE PLATE FASTEND W/
3/8"x4" POWERS WEDGE
BOLTS @32" O.C.
TRUSS ROOF W/
TAPPERED METAL
PANEL ROOF
N II
6"x16GA METAL FRAMING
@24" O.C. (TYP.) W/ METAL SIDING
STORAGE ENCLOSURE
IrIr jrl+ .
I II
SIMPSON H3 ALL WOOD TO WOOD CONNECTIONS U.O.N.
B
1r (
2))2x6 CONT. ® PERIMETER
1 ()16d2NAILS EACH POST
2x6 BRACE EA. WAY
EACH CORNER
I I I I I I I of I I I I
I I I I I I I ®I I I I I I
co
M AL DE K OVE 2x4 4" O.C.
W #12x2' S REWS 24" .C. TEK
I I I I I (RIDGERIDGE
I I 12X82X8 RIDGE 2Xfi
BU
O
I I I I I I I I I I II
POLE BARN FRAMING PLAN
SCALE: 1/4"=V-0"
a POLE BARN PLAN
SCHEMATIC SITE PLAN
5o
GRAPHIC SCALE
o
IN FEET )
1 inch = 50 ft
EXISTING AERIAL VIEW
N.T.S.
rvvuvur, on u
METAL DECK OVER 2x4@24" O.C.
W/#12x2" TEK SCREWS @ 24" O.C.
I— SEE PLAN FOR FRAMING —
SIZE & SPACING
Ii
i
METAL SIDING OVER 2x4
@ 32" O.C. *
12x2" 12x2TEK SCREWS @24" O.C. I
4x4
POST @ 5' O,C. 14"
0 x 24" D CONC.
FTG. TYP. GRADE
BARN
SECTION B-B REVISIONS
I BY cc
co
co W
c\jto 1 Cco
c
e0Cc
7 •' 1\'
0
ko
w
p
O O
U
a
w W
U
4
W
x O
U
W
EF
W
SCANNED
Q
StLUCP P,
GounfyO O D
CIO
V
J
oc F.
B.
C. 2020, 7TH EDITION ASCE-7-
16 EXP. 'C' 170 MPH (
ULT.) RISK CATEGORY
II 3000 PSI
CONCRETE ACI CODE
AISC CODE (
36 KSI STEEL) LUMBER SYP #
2 OPEN STRUCTURE:
37.9
PSF 50.7
PSF DATE 7.
7.
2021 FILE TOMTW
DRAWN
SCALE:
SHEET #
0
a
w
E-
I
w 1
of
1 N
ELECTRICAL PANEL NOTES
1) SMOKE DETECTORS SHALL BE INSTALLED AHEAD OF ALL
SWITCHES AND SHALL BE CONNECTED TO BATHROOM OR
KITCHEN LIGHTING CIRCUITS. SMOKE DETECTORS SHALL BE
U.L. LISTED AND MEET THE REQUIREMENTS OF NFPA 74
AND NFPA 72-E.
2) THE PANEL SCHEDULE SHOWN ON THIS PLAN IS ONLY FOR
BREAKER SIZE REQUIREMENTS, WIRE SIZE, LOADS, AND
NUMBER OF CIRCUITS REQUIRED. ACTUAL SEQUENCE AND
DESCRIPTIONS SHALL BE PLACED ON INSIDE PANEL
COVER BY ELECTRICAL CONTRACTOR.
3) SMOKE DETECTORS SHALL BE POWERED BY HOUSE
ELECTRICAL SERVICE W/ BATTERY BACK-UP.
4) MULTIPLE DETECTORS SHALL BE INTER -CONNECTED.
FAULT CURRENT FROM SECONDARY TERMINAL OF MAXIMUM TRANSFORMER
SIZE OF 75 KW IS EQUAL TO 26, 194 SYMMETRICAL AMPERES AT 120/240 VOLTS
AS PROVIDED BY FLORIDA POWER AND LIGHT COMPANY AT WORST CASE, A
1/0 ALUMINUM SERVICE WIRE FOR A DISTANCE OF 38 LINEAL FEET PRODUCES
AN AVAILABLE FAULT CURRENT OF 9848.94 AMPERES.
NOTE:
1.75% OF INSTALLED LIGHTING FIXTURI SHALL
HAVE HIGH EFFICIENCY LAMPS.
2.RECESSED LUMINAIRE INSTALLED IN NUILDING
THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR
LEAKAGE BETWEEN CONDITIONED & UN -CONDITIONED
SPACES. THE HOUSING CANS
SHALL BE LISTED IC -RATED IF IN CONTACT WITH
THERMAL INSULATION
GENERAL NOTE:
ELECTRICAL CONTRACTOR SHALL VERIFY ALL EXISTING
CONDITIONS IN FIELD PRIOR TO CONSTRUCTION.
ELECTRICAL SERVICE NOTE
1. ALL ELECTRICAL SERVICE EQUIPMENT SHALL HAVE MIN A.I.C.
RATING OF 10,000 AMPS AND SHALL BE NEMA-3R RATED.
2. ALL ELECTRICAL EQUIPMENT AND WIRE SHALL BE RATED 0
75°C CONTINUOUS DUTY.
3. PRIOR TO CONSTRUCTION. THE ELECTRICAL CONTRACTOR SHALL:
a) VERIFY ALL EXISTING CONDITIONS IN FEILD
b) COORDINATE THE ELECTRICAL SERVICE WITH FP&L REPRESENTATIVE
AIR CONDITIONING EQUIPMENT AND CONTROLS SPECIFICATION
1.ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONTROL RACEWAY (CONDUIT), WIRE INSTALLATION,
CONNECTIONS ETC. IN ACCORDANCE WITH WIRING DIAGRAMS ON AIR EQUIPMENT.
2.A/C / ELECTRICAL PLANS OR DIAGRAMS FURNISHED BY MANUFACTURER OF THE EQUIPMENT.
3.ALL POWER WIRING FOR THE AIR CONDITIONING EQUIPMENT SHALL BE FURNISHED,
INSTALLED AND CONNECTED UNDER THIS SECTION OF THE SPECIFICATION.
CMECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTERS FOR ALL AIR CONDITIONING
EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONNECTIONS TO AIR CONDITIONING
EQUIPMENT PER MANUFACTURERS SPECIFICATIONS.
S.AIR CONDITIONING EQUIPMENT INCLUDES CONDENSOR, COMPRESSOR AND FAN, FAN COIL UNITS,
ELECTRICAL STRIP HEATER, THERMOSTAT, ETC.
LIGHTING NOTES
I. LOW VOLTAGE • ELECTRICAL CONTRACTOR TO VERIFY IF ANY LIGHTING FIXTURES REQUIRE STEP-DOWN
TRANSFORMERS. QUANTITY AND LOCATION OF THE TRANSFORMERS TO BE FIELD VERIFIED
PRIOR TO CONSTRUCTION.
2. ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY CONTRACTOR
ELECTRICAL NOTES
1. ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION
ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE,
1S- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS,
DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS,
HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED ;'( _• `:; ".a" _
BY A COMBINATION TYPE ARC -FAULT CIRCUIT INTERRUPTER
INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.
A DUAL FUNCTION AFCl/GFCI CIRCUIT BREAKER IS
ACCEPTABLE IN LOCATIONS REQUIRING BOTH GFI
AND AFCI PROTECTION.
2. ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL SIMULTANEOUSLY W/ TEMPORAL SOUND.
SMOKE DETECTORS TO BE LOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS, KITCHENS, BATH ROOMS.
3. ALL LIGHTING FIXTURES AND FANS TO BE SELECTED BY OWNER, UNLESS OTHERWISE NOTED.
4. OWNER TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE APPLICABLE, UNLESS OTHERWISE NOTED.
5. NOT USED
6. FOR FLOOR RECEPTACLES, PROVIDE A BRAGS COVER PLATE AND FLUSH WITH FLOOR.
VERIFY EXACT LOCATION WITH GC/OWNER: PROVIDE 1/2"C UNDERSLAB FROM WALL.
7. CABLE TYPES NM, NMC OR NMS MAY BE U9EO WHERE CONDUIT IS NOT REQUIRED.
8. BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT.
9. PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "I" BOXES.
10. NOT USED
11. NOT USED
12.VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL AHU'S AND CU's WITH MECHANICAL
CONTRACTOR
13.A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE REQUIRED PASSAGEWAY
OPENING AND A RECEPTACLE OUTLET SHALL BE PROVIDED AT OR NEAR THE
APPLIANCE LOCATION IN ACCORDANCE WITH NFPA 70.
14.VERIFY EXACT LOCATIONS OF ALL KITCHEN EQUIPMENT WITH OWNER PRIOR TO CONSTRUCTION.
VERIFY ALL ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION.
15.LIGHTING IN CLOTHES CLOSETS MUST COMPLY WITH N.E.C. 4.1O.B/D/1 THRU 4.
16.TAMPER-RESISTANT RECEPTACLES SHALL BE PROVIDED THROUGH DWELLING UNIT.
ELECTRICAL SPECIFICATIONS
1. DO NOT SCALE THE ELECTRICAL DRAWING. REFER TO THE
ARCHITECTURAL PLAN AND ELEVATIONS
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2017 EDITION OF THE
F.B.C. 2011 EDITION NATIONAL ELECTRICAL CODE AND 2012 EDITION OF NFPA 101.
3. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER.
INSULATION SHALL BE 90° C THHN / THWN FOR ALL SIZES. ALL
CONDUCTORS #12 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #10 AND
LARGER SHALL BE STRANDED. ALL CONDUCTORS EXPOSED TO DAMP OR WET
LOCATIONS SHALL BE LISTED FOR USE IN DAMP OR WET LOCATIONS.
4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY
WITH THREADED HUBS IN WET LOCATIONS AND SPECIAL ENCLOSURES FOR
OTHER CLASSIFIED AREAS.
5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUN, QUICK MAKE,
QUICK BREAK, WITH ENCLOSURES AS REQUIRED BY EXPOSURE.
6. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF
CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL
ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALL REQUIREMENTS
NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER.
7. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED
AS REQUIRED IN ARTICLE 250, NATIONAL ELECTRICAL CODE.
B. ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS
WHERE APPLICABLE.
9. ALL WORK SHALL BE PERFORMED BY A LICENCED ELECTRICAL CONTRACTOR
IN A FIRST CLASS WORKMANSHIP MANNER, THE COMPLETE SYSTEM SHALL BE
FULLY OPERATIVE AND ACCEPTANCE BY ENGINEER/ARCHITECT MUST BE A
CONDITION OF THE SUBCONTRACTOR.
10. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS
OF POWER, LIGHT COMPANY AND TELEPHONE COMPANY.
11. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE.
THE CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT JOB CONDITIONS.
12. SEE NOTES ON PLANS FOR OTHER REQUIREMENTS.
13. NOT USED
14. AU. WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID
INTERFERENCE WITH THE PROCESS OF CONSTRUCTION.
15. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL
CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY PHASE OF THE
INSTALLATION WHICH MAY BE DAMAGED.
16 ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST
PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
17. CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT
BEFORE CONNECTION TO CIRCUITS.
18. ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED
AGAINST THOSE SPECIFIED OR INTENDED AND REVISE BRANCH CIRCUITS AS
MAY BE REQUIRED WITH PRIOR APPROVAL OF GC.
19. PADDLE FAN JUNCTION BOXES SHALL BE LISTED FOR
USE WITH PADDLE FANS BY THE MANUFACTURER. WEIGHT
LIMITS NOT TO EXCEED 70 LE S.
20. ALL GFI OUTLETS MARKED AS'WP' SHALL HAVE A
WATERPROOF ENCLOSURE PER NEC.
ELECTRICAL LEGEND SA
SMOKE ALARM
HARDWIRE WITH
BATTERY BACKUP
DUPLEX RECEPTACLE SWITCH n4
TELEVISION JACK
COMBO SMOKE ALARM
002 ALARM HARDWIRE WITHBATTERYAFCIAT12'A.F.f iYP. U.N.O. ARC FAULT SINGLE POLE PREWIRED BACKUP
DUPLEX RECEPTACLE SWITCH DEDICATED RECEPT. SWITCH
GCI GROUND FAULT THREE WAY AT 12" A.F.F. (220 V) DISCONNECT
DUPLEX RECEPTACLE SWITCH HVAC OF PRE -WIRED SWITCH AND
A TOP REC. SWITCHED
4 FOUR WAY O THERMOSTAT BOX FOR FAN OPTION
WP/GFCI
GROUND FAULT
DUPLEX RECEPTACLE TELEPHONE OUTLET FLUORESCENT
LIGHT FIXTURE
ELECTRICAL METER
WATERPROOF AT 12" A.F.F. CaF•P•L.
Q PUSH L.E.D. SECURITY L.E.D. LIGHT BREAKER
BUTTON LIGHTS FIXTURE CLG. MINTED. PANEL
duc
DUPLEX RECEPTACLE
L.E.D. MINI HI HAT
L.E.D. LIGHT EXHAUST
AFCI UNDER COUNTER ARC FAULT FIXTURE WALL. MNTD. FAN
GROUND FAULT
DUPLEX RECEPTACLE DOOR L.E.D. HI HAT LED STRIP LIGHT -
C/GFCI ABOVE COUNTER CH CHIMES CLG. MOUNTED MNTD. UNDER CAB.
Q
CO2 ALARM HARDWIRE
WITH BATTERY BACKUP FAN / L.E.D. LIGHT L.E.D. HI HAT 0 L.E.D. LIGHT BAR
MOUNT 60" AFF VP VAPOR PROOF
3) 2/0 COPPER
1#6 GREEN
IN 2" PVC
METER 200 AMP
1
PANEL
200A
RAIN BREAKER AIC RATING FOR MAINODISCONNECT10,000 42 CIRCUIT
1
2 COPPER THHN
IN SCH 80 PVC CONDUIT
GNO ELECTRODE
FPL GROUND ROD
TIED TO SLAB
STEEL
GRADE
0
ELECTRICAL RISER DIAGRAM
GFCI 42"
AFF
L- L - - - _ _
I
GFCI 42" GFCI 42"
AFF AFF
I
GFCI 42" SS GFCI 42"
AFF AFFJAESSGFCI 42"
AFF AFF 7
0 011 o 00 - o0 00---------- 0o
ELECTRICAL PLAN
SCALE: 1/4" = V-0"
l(11iffie ffam
EXISTING
GARAGE
ELECTRIC
PNLA200A
EXISTING
GARAGE
rich itectu ra I
onsultants
nc.
ARCHITECTURE / DESIGN
Lic. No. 26002046
2475 MERCER AVE. SUITE 201
West Palm Beach, FL 33401
Phone 561-655-0674
RENOVATIONS
TO
GARAGE
16142 EAST BURNS DRIVE,
LOXAHATCHEE, FL.
CONTRACTOR AND ALL SUBCONTRACTORS
PERFORMING ANY WORK ON THIS
PROJECT ARE TO VISIT THE SITE AND
VERIFY ALL MEASUREMENTS INCLUDING
BUT NOT LIMITED TO BUILDING HEIGHTS,
ROOF SLOPES, ROOM DIMENSIONS ETC.
TO CONFIRM ALL EXISTING CONDITIONS
BEFORE ORDERING OR FABRICATING ANY
MATERIALS. CONTRACTOR SHALL REPORT
ANY INCONSISTENCIES WITH THE
CONSTRUCTION DOCUMENTS TO THE
ARCHITECT BEFORE CONTINUING WORK.
REV # DATE DESCRIPTION
SEAL
ROGER HANSROTE, ARCHITECT
FLAR # 14300
JOB NUMBER: 2020-41
DATE:06-02-2020
DRAWN BY: JP
APPROVED BY: RH
SHEET TITLE
SHEET NUMBER
PERMIT ISSUE 06-29-2020
A4n 0