Loading...
HomeMy WebLinkAboutTYPICAL SCREEN ENCLOUSURE DETAIL3' x 3' x 0.090 MIN. 6063-T6 ALLOY PLATE OR STRONGER MANE SIDE) WITH (3) - Nt2 x Y4' Sim EACH SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE IL C-C FASTENER SPACING) 3' x B' x 0,050' MIN. 6063-T6 — ALLOY PLATE OR STRONGER (ONE SIDE) } .I i (3) - 012 x ` V4' INS, EACH SIDE AS SHOWN (W HIN, PLATE EDGE DISTANCE & C?C FASTENER SPACING) 1, s �4 FOUNDATION --� (3) 012x3/4" S.M.S. 14 O.B. ATTACHED TO BEAM W/ (2)-jIGX2- S.M.S. INTO SCREW BOSS (1)-1/4-)4' S.S. THRU-BOLT W/ Y�' NUT AND WASHER O. EACH SIDE OF BEAM j12x2- S.M.S. O 24- O.C. 1.2 O.B. TO SUPER GUTTER t (4) f12x3/4" S.M.S. ROOF BEAM (FLAT OR SLOPED) CORNER POST CAVE RAIL SJ AS TAL) - .1 'x-�• SCANNED 1' x 2' O.B. SJLS AS SHOWN 1 P@1. PATIO SECTION PLATE EDGE DISTANCE 4z;. C-C FASTENER SPACING) y y B A O 6' x 5' x DASO' Cdlltc;ie®ul lj e e 6063-T6 ALLOY PLATE O (ONE SIDE) OR STRONGER K-BRACE 2x3xO.O70 CHAIR RAIL \ O O K-BRACE 0 \ O O O K-BRACE O 00 CORNER POST I. r K-BRACE GIRT (CHAIR RAIL) V x 2• ROLE PLATE ■ SEE ELEVATIONS FOR 'K' BRACE SIZE L %' 0 CONCRETE ANCHOR (2 PLACES) IN LIEU OF TYP. Me 0 CONCRETE SCREVS FOR CORNER COLUMN _ LATERAL "W - BRACING, -- --_CONNECTION DETAILS- ANGLEEACH NG BAN) Y'Ox3' LIS a EACH ANGLE NOTES DISCREEN ENCLOSURE BEAMS SHALL BE ATTACHED TO HOST STRUCTURE ,CONSISTING OF CONVENTIONAL TRUSS/RAFTER FRAHM WITH MAX i- FACIA TO BE 2x6 QUW S.P.F. OVERHANG NO TO EXCEED 3V UNLESS OTHERWISE NOTED ON PLAN DWG.. OR WESTER RED CEDAR STRUCTURAL GRADE 2 HIM. (D )a'®x2' LG. LAG SCREW a 24' D.C. ENTIRE LENGTH IF GUTTER SECURE FASCIA TO EACH RAFTER TAIL (2 /tOx4' S:M.S. TI 1Ox W/ (1) Y'Ox4' LONG PAN HEAD LAG BEFORE ATTACHING SUPER GUTTER SCREWS �E!2 INTO- PURL BASES USE %10x S.M. TO CONN •T.M. ((1)-244ia' ANGLE.-FACH..SIDE 4(2FOR'2x8 _SMB-_QNr1&4t=.) (1) Ys'Ox2' LIS. LAG SCREWS /J (TYP. a EACH BEAM) 1x2 O.B. FASTENED (D 912x2' S1LS Q 12' ac. (H /4- S.M.S. (MAX) BETWEEN BEAMS W/(2) j1Oxt)r S.M.S. IN EACANIH E � S' or 7' SUPER GUTTER ICK CONTINUOUS % MIN. 0A90',THICK ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Y'Ax4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER j100/4' S.M.S. Y1 CONTDNUUS BEAD OF CONSTRUCTION O 2' O.C. ADHESIVE 1xbW BY 2' LONG ANGLE. EACH SIDE (TYP.) 24 SCRREW ' S.M.S.. - EACH LEG (TYP.) HOLLOW POST — BEAM STITCHING SCREWS (SEE TABLE) a 24 QC. S SPLICE PLATE (EACH SIDE DF BEAM) SPACE SCREWS' A A 5052-4M ALLOY OR EQUAL, 1/9' THICKNESS EQUALLY (TYP.) T:t J _k Ys �pl 814x%'ol SCREWS 13�tw CIO) 2x8 Lmo M )ETAIL fz'xaxo.o70 AT/i (SEE PLAN) MIN. S.M.S. IN(4) All (TYP. ALTER CHAIR RAIL / GIRT TO POST CONNECTION DETAIL (3) j1W S.M.S., EACH LEG AND (9) 01234' S.M.S. CHANNEL.TO BEAM 9 SCREW TOTAL 2x3xO.070 u. 0.082' MATERIAL THIM x 2 1/8" x 1" x 3" LG. P. ALTERNATIM F-2�'-I I BEAM :p: •B'17C' T6TAL WIDTH 2x4 3 2 24 12' 2x5 3 3 32 14' 2x6 4 3 40 14' 5 6 7 64 16, 72 18' Be 18, 96 18' MIN. (4) j10x3- LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATIVE) BEAM STITCHING O 24" O.C. - (TYP. TOP AND BOTTOM OF SMB SEE TABLE FOR SIM) PURLIN TO ROOF BEAM CONNECTION DETAIL .1034" BY 3' LONG ANGLE, EACH SIDE (IYP.) (LEG 311s US-M(1rPE " 2x3xD.045 EAVERAIL ATTACHED TO BEAMS WITH (3)-1104- S.M.S. Y a- _ S.M.B. BEAM _ INTO SCREW BOSS. > ' MAY BE SLOPED OR FIAT -(Mq ® 'SLOPED - - <gv� (SEE PLAN FOR SQ.L� Y � ci IN SCREW 2x5x.125 ANGLE-2" WIDE - - _WITH ,&-#1IPRIGHf� BEAM & (2)-/14x1 ow J / f O.B. TO 2x3. USE %10z tY'�S.M.S. O 24' O.C. { TO CONNECT TO 1x2 O.B. TO 2x3. ,t .COLUMN/POST 'SEW BOSSES END. PURLIN FASTENED TO COLUMN/POST WITH(4) j12x1' S.M.S. (EACH LEG) OF)BEAl1 (TYP,) OR EACH SIDE I�• MIN.. 3 I¢' MAX. C-C ACH ') USINGTHICK FLAT BAR BENT (6 'I 12x31' S.NS. EACH SIDE SPACING tIF FASTENERS (TYP.) TO Frt�(BD63-T8 ALL" dF.?FOR 2x5 COLUMN TO j�• NJBEAN EDGE DISTANCE (TYP.) COLUMN/POST i +�'� \ COLUMN/POST SIDEWALL= POSY/ COLUMN TO PURLINMAIN POST / COLUMN TO ROOF BEAM,, - CONNECT -ION DETAIL CONNECTION DETAIL DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Tel: (813) 374-0321 I0I2015IISSUED I c> p C LLI o D U O J U Z U LLl W N O � ii I- J w � a U 0 DRAWN BY: DYK CHECKED BY. DYK SCALE: AS SHOWN DATE: BI11106 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KI & SOCKTES, LLC CAV 26887 O 1 pa. 33679 .Z,9-(7 Drawing No. - 060811 SHEET 1OF3 , Pt UPPORT C( M u.POST - Ya' ANGLE. EACH SIDE (TYP.) 2x2x1/8' x 2' LG. ANGLE S.M.S. WITH MIN. ib' %'0 CONCRETE ANCHOR BEM A W/ (4) /12x3/4' S.M.S D EDGE DISTANCE W /lib' EMBEDMENT INTO - - (1 �► (EACH SIDE) STRUCTURAL CONCRETE (TYP.. O O -%-0 CONCRETE ANCHOR � ��rf-gEEEEEE NOTE 10) f 1'x2' O.B. SOLE PLATE i • \. O O W 9W EMBEDMENT INTO STRUCTURAL CONCRETE t 2'x PURUN - • (EACH SIDE) j / ••* ' L = `�' •• 2 yAx ANGLE CUP, CUT AT 1x3 O.B. FASTENED TO CORNER A 45' (+/-) ANGLE AND SECTION WITH 110x2' S.M.S. W/ 3' MIN. ¢ BEAM MAY Y4bx2Y4 CONCRETE BE FLAT ATTACHED TO THE SCREEN ROOF %' CIA. WASHER O 18' O.C. BEAM WITH ONE (1) Y4'0 THRU- /(TYP.) i~�m SCREW ANCHOR O 24' O.C. OR SLOPED AND 9' FROM POST n J BOLT. WITH FENDER WASHER. ATTACHED TO BEAM OR EAVE RAIL ,,(TYP.),, O DIAGONAL BRACING SHALL NOT BE �• ATTACHED TO ROOF PURUNS. COLUMN/POST 2xNO.093 BRACE SIDEWALL COLUMN TO CONCRETE 9• (SEE PLAN) - CONNECTION-.DETAIL� 1x2 O.B. SOLE PLAT PLAN-- TYPICAL DIAGONAL ROOF BRACE CONNECTION,, O OF CONCRETE J 1' (TYP.) u �� PLAN VIEW it �J e.. Z / J S.M.S. WITH MIN. EDGE DISTANCE 5, Ya' ANGLE, EACH SIDE (TYP.) WO CONCRETE ANCHOR W/lib' EMBEDMENT INTO STRUCTURAL CONCRETE (TYP., �SEE'NOTE 10) i-1'x2' O.B. SOLE PLATE j J 3' MIN. (TYP.) rc YtVO4Y4 CONCRETE EZ SCREW ANCHOR O 24' D.C. AND 9- FROM POST (TYP.) �occ 'A rZ COLUMN/POST 1x2 O.B. SOLE PLATE O I EDGE OF CONCRETE 1' CTYPJ N a /- PLAN VIEW MAIN COLUMN TO CONCRETE `, CONNECTION DETAIL. - NI BEAM SUPPORT COLUMN/POST 240/8'�x 2' I.G. ANGLE W/ (4) /12x3/4• S.M.S (EACH SIDE). /r POST - m .--- COLUMN 21¢' MAX. THICK BRICK PAVERS SET IN MORTAR ON TOP OF F'OOTER • O.B. SOLE PLATE Z N Y4 04' CONCRETE SCREWS O 24' D.C. lib' MIN. CONC. (TYP.), tjfi' CONC. EMBEDMENT (MIN.) EMBEDMENT (TYP.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION. CONNECTION WITH PAVERS 4' NOMINAL CONCRETE SLAB (2500 PSI, MIN.) W/6x6x10 10 W.W.M. OR FIBER REINFORCED [POL15 POUN D ENN FIB C.Y,] • •••• • •4' ..• ..•. • .. d .d _ a, •• y' '4 • e, .•UNDISTURBED SOIL OR COMPACTED _ CRUSHED UMEROCK (90X PROCTOR) MIN. (1)-15 REBAR CONTINUOUS. SPLICE MUST OVERLAP 20' MIN. 3' COVER (TYP.) 8'CNIN� FOUNDATION/SLAB DETAIL w l 2x5xW ANGLE (2' LONG) V/ (2)-#14 TEKS INTO TOP OF 2x3 EAVE RAIL AND (2)- 014 TEKS INTO THE FRONT [IF THE CORNER POST L-1x2 O.B. TOP FRAME CORNER POST Ix O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST / COLUMN UPRIGHT DETAIL 'd o ' d APPROXIMATE v/ G I v d. • v d 2500 PSI MIN. CONCRETE STRENGTH COMPACTED OR UNDISTURBED SOIL/SAND •(1)-/5 REBAR, CONTINUOUS 3- MIN. CONC. COVER, 36- MIN. LAP SPLICE MIN. CONTINUOUS PERIMETER FOOTING (4) /12:Yi 2'x PURUN BEAM MAY BE FLAT OR SLOPEC ((4) 1lo.A ((TYP. EACH (TYP. EAC` H PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 RNATE (1) i ANGLE E A,- ANGLE (BRACE) W/ 112i S.M.S. O EACH ER INTERSECTION 6' ANGLE 2' LONG ON RSIDEW/(4) 112xY4 S.M.S. LEG (BEAM & BRACE) 3RACE PLAN) ALTERNATE (2) 20 BRACE DO KI M & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 1DD39 Tampa, FL 33679 Tel: (813) 374-0321 D 12015 I ISSUED I 0 M J H W � C W U � O J V Z Ill !l) C Z 1% (L � Z U w cn a Lu U DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11/06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM SS CIATES, LLC 7 PO 39 Tam , FL333679 2- L- Drawing No. - 060811 SHEET 2 OF 3 P DOUBLE S,M,B. BEAM (SEE (FORE) OST (4)-%' THRU-BOLT W/ Ik ASHERS I DOUBLB S.M.B. BEAM (SEE PLAN FOR SIZE', (4)-%l THRU-BOLT W/ 11. 1WASHERS NOTCH POST TO ACCEIPT BEAM POST DET, NOTCH KNEE BRAC_ .4CCEPT BEAM FASTEN WITH (6) Oi4kie S.M.S., _ - - S.M.B. BEAM DOUBLE BEAM (PATIO/S.M.B'.)' yEE (SPLAN FOR SIZE) EACH SIDE. OR (2) Y4.0 THRU BOLTS #14x 4' m 24° O.C. _ •- W/ WASHER 8 (TYP4 7700 KI M ASSOCIATES, LLC CONSULTING 2x3xo.o44 F: STRUCTURAL G 1 ENGINEERS (1)=�10xii 12" O.C. OR i� 4x4xo.125 KNEE BRACE PO BOX 10039 (1)-#.14rY4 O 24" O.0 S.M.S. �� Tampa, FL33679 AT MIDHEIGHi OF SEMI Tel: (813) 374-0321 ' 2x2x16' ANGLE (EACH SIDE z (ALTERNATrq CONNECT KNEE�BRACE (1)-�8x3i S.M.S. ) ) i a .= W ',WO5O THICK 'U CHANNEL, 6063 T64 A 24' O.C.. TOP / O RevJDat Descri lion $BOTTOM 4f .,; O ALLOY PLATE OR STRONGER FASTEN. (8) �14=2x3i S.M.S. EACH SIDE ? O WLTH-C4>`pl'4X4' SNS_EAGH,-SIDE. - s27 ISSUED OF BEAM OR (2) Yi 0 BOLTS3W/ "VASHER'& NUT 0 2017 DOUBLED BEAM •/ � O - . - _ __ _ _ _ _ _ _ .,"�'�� . (SEE PLAN FOR SIZE) f O BEAM STITCHING SCREW ® 24" O.C. Ir a. (TYP. TOP AND BOTTOM OF SMB) ry' KNEE BRACE LENGTH Q (24' MIN.) TYP-,(4)-814x%" S.M,S. BEAM TO DOUBLE CARRIER ' BEAM CONNECTION _ r^ KNEE BRACE CONNECTION DETAIL. MIN., EQUALLY ACED (TYP.) )PED) W/ (8)-MIN. #12x3/4" S.M.S EACH LEG (2)-#14x-Y S.M.S. ROOF BEAM TO CARRIER ---BEAM, CONNECTION THROUGH h OF 2x UPRIGHT INTO POST m 12" O.C., y _. POSE (SEE PLAN FOR SIZE) W�4'BOLT IY4'0 WASHER MS 4' BASE INSERT W/Ofi' VERTICAL ;HT OR O.B. LEGS W THICK 6063-T6 ALLOY PLAN DO NOT USE CAST ALUM. BASES (TYP.) SIZE do nON) I L I/ (4)-%'0 HOT DIPPED GALVANIZED /— WEDGE ANCHORS W/ 2Yi MIN. EMBEDMENT n r, / n INTO CONCRETE. ;� , t ; . c . •• TOP OF CONCRETE EAW General Notes and Specifications: co 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate LLJ p consideration. uu 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. V Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. O 0 _3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. C3 U W 4. The following structures are designed. to be attached to block and wood frame structures of adequate structural capacity. The (D W contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If c Z LU w there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host a O 0 CO structure capacity. ~—a, Q 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy; for secondary Z W UJ a components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. U U 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. DRAWN BY: DYK CHECKED BY: DYK 3. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise. SCALE: AS SHOWN 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. DATE: 8111106 ..f.: �y (44.125 POST TO CONCRETE 2' MIN. EDGE ?=` 'n'j CONNECTION -DETAIL-.. - _ _ DIS ANCE;(- C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) N, Minimum Edge Distance Minimum Center to Center Distance #10 0.188 5/16 I/2" #12 0.219 3/8" 9/16' #14 (1/4") 0.250 5/8" 9. Structure has been designed to meet the 61h Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, Volt, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, 2013 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASD). DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM telCIATES, LLC C 87 PO 1 1039 Tam L 33679 2T ty 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws Drawing No. - 060811 or approved equal. SHEET 3 OF 3