Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOF UNDERLAYMENTSi I SCANNED Professional Lucie GoufifVrara BCIS Home I Log In I User Registration. Hot Topics Submit Surcharge i Stats & Facts Publications I FBC Staff BCIS Site Map Links ` Search j Florida 0. Product Approval ei USER: Public User IxQ;Yar :•I J.ib Rv�nt: s�>r:r-n PreEuct Aoaroval Menu > Product or Aenlicatlon Search >. Application Ust > Application Dotall FL # FL9777-R11 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Owens Coming Address/Phone/Email I One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Undorlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida license PE-74021 Quality Assurance Entity. UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden 10 Validation Checklist - Hardcopy Received Certificate of Independence FL9777 R11 COI OCR14002 8a 2017 FBC Evaluation Report Wa_atherinrk Non-HVHZ.odf Referenced Standard. and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2012 Equivalence of Product Standards Certified By . Sections from the Code File C®py Product Approval Method Method 1 Option D Date Submitted 10/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval I 10/17/2017 Date Approved 12/12/2017 summary of Products FL # Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: No, Approved for use outside HVHZ: Yes Impact. Resistant: N/A • Design Pressure: N/A Installation Instructions FL9777 1111 II OCRI4002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Verified By: Zachary R. Priest 74021 Created by IndependentThlyd Party: Yes Other: See evaluation report for limlts of use. Evaluation Reports FL9777 R11 AE OCRI4002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.ndf Created by Independent Third Party: Yes 9777.2 WeatherLock G (High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No M9777 RI 1 II OCRI4002 8a 2017 FBC Evaluation Report W-eatherlock Non-HVHZ.odf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCRI4002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Created by Independent Third Party: Yes 9777.3. Weatherlock MAT Waterproofing Underayment Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 1131 II OCR14002.8b 2017 FBC Evaluation Report_ Weatherlock HVHZ.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002 8b 2017 FBC Evaluation Repo Weatherlock HVHZ.vdf Created by Independent Third Party: Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use i Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 R11 II OCR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCRI4002 8a 2017 FBC Evaluation Report Weatherlock Non-H_VHZ.odf . Created by Independent Third. Party: Yes 9777.5 1 WeatherLock Metal I Weatherproofing Underlayment I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 R11 II OCRI4002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation. Reports FL9777 R11 AE OCRI4002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes 19777.6 1 WeatherLock Metal I Weatherproofing Underlayment I Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 1131 II OCRI4002 8b 2017 178C Evaluation Report Weatherlock HVHZ.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCRI4002 8h 2017 FBC Evaluation Report IWeatherlock HVHZ.Ddf Created by Independent Third Party: Yes 9777.7 WeatherLock Specialty Tile & Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R31 II OCR14002.8a 2017 FBC Evaluation Report Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ:g_df Impact Resistant: N/A Verified By: Zachary R, Priest 74021 Design Pressure: +0/-142.5 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 1111 AE OCRI4002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes Back Nett Contact Us :; 26D3L_13_Ialr Stone Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO. employer. Copyright 2007-2013 State of Florida, :: Privacy Statement:; Accesslbilhv Statement:: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by.phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for offlclai communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: . ®® Credit Card Safe C REEK TECHNICAL.. SERyICES, LLC EVALUATION REPORT Manufacturer: Manufacturing Location: Quality Assurance: SCOPE Category: Subcategory: Code Sections: Properties: REFERENCES Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, eH EornON OWENS CORNING ROOFING AND ASPHALT LLC issued October 11, 2017 1 Owens Coming Parkway Toledo, OH 43657 (800) 4384465 www. owenscomin4.com Brentwood, NH Houston, TX UL LLC. (QUA9625) Roofing Underlayments 1504.3.1,1507.1.1 . Physical properties Report No. Standard Year 2015 Ent( PRI Construction Materials Technologies (fST5878) NEI039-02-012015 NEI-042-02-01 REV2 ASTM D 1970 PRI Construction Materials Technologies (TST5878) Materials Technologies (TST5878) NEI-045-02-01 TAS , 31970 155 1995 2005a PRI Construction PRI Construction Materials Technologies (TST5878) NEI=045-02-01 ASTM G TAS G � 1995- PRI Construction Materials Technologies (TST5878) NE1053-02-01 NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (fST5878) Materials Technologies (TST5878) OCF-213-02-01 D ASTM D 1623 2009 2012 PRI Construction PRI Construction Materials Technologies (TST5878) OCF-237-02=01 UL ASTM D 4798 . 2001 PRI Construction Materials Technologies (TST5878) OCF-252 02-01 ASTM D 1970. 2015 PRI Construction Materials Technologies-(TST5878) Materials Technologies (TST5878) OCF-252-02-02 ASTM D 1970 TAS 103 TAS 2015 1995 PRI Construction PRI Construction Materials Technologies (TST5878) Materials Technologies,(TST5878) OCF-272-02-01 OCF-296-02-02 AC 188' AC 48 2012' 2012 PRI Construction PRI Construction Materials Technologiesj(TST5878) OCF-297-02-01.1. OCF-318-02-01 ICGES ASTM D ASTM D 197.0 2015 2015 PRI Construction Materials Technologies' (TST5878) PRI Construction Materials Technologies (TST5878) OCF-320-0241 ASTM TAS 103 15.. 5 1991995a PRI Construction Materials Technologies (TST5878) OCF-320-02-01 OCF-321-02-01 ASTM•D 1623. • 2009 PRI Construction Materials Technologies (TST5878) Technologies (TST5878) OCF-322-02-01 . UL 1897 1897 2012 2012 PRI Construction Materials Materials Technologies (TST5878) OCF�55-02-01 UL PRI Construction 'Determined to be equivalent to ASTM 6 226-09, Type I. and II O FL9777-R11 CR14062.8a Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule notify CREEK 61 G20-3. The manufacturer shall Technical Services, LLC of.any product changes or quality assurance changes throughout the duration for which.this.report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributea that are not specifically addressed herein. i CREEK TECHNICAL SERVICES, LLC PRODUCT.DESCRIP`i lON AND LIMITS OF WeatherLock® G. (Brentwood, NH) Weatherl-ock® Mat (Brentwood, NH or Houston, TX) WeatherLoeM Metal (Brentwood, NH) WeatherLock® Specialty Tile & Metal (Brentwood, NH or Houston, TX) , WeatherLock® G (High Tear) (Houston,.M: OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing lea & Water Barriers i WeatherLock® G is.an ASTM D 1970 self-adhesive undedayment constructed from SBS modfied asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.74 i WeatherLock® G is permitted to be used as prescribed. in FBC Section 1507.1.1 for mechanically attached roofing coverings.. Exposure on the roof deck shall. be limited to a maximum 30 days. i ' WeatherLock® Mat. is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3 it x 66.74L 1 WeatherLock® Mat is. permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. i WeatherLock®. Metal is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. • The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1607.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days:: Weatherl-odO.. Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment constructed from'SBS modified asphalt and surfaced with a non -woven polyester fabric. The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. WeatherLoIck® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 15107.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered. clay or concrete the roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives!:and Sealants, Inc.) or TILE BOND Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete file installations without battens. Tile shall be, stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per. stack. WeatherLock® G (High Tear) is a self -adhered, underlayment used as an alternative to ASTM D 226, Type I or Type 11 roofing felt and ASTM D 1970 self -adhering polymer modified bitumen underlayment The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with -nominal dimensions of 3 it x 65-ft. WeatherLock® G (High Tear). is permitted to be used as 'prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. i. FL9777-R11 Page 2 of 4 OCR14002.8a Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK This evaluation report is provided for State of Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not "specifically addressed herein. CREEK TECHNICAL SERvicES, LLC OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing tee & Water Barriers PRODUCT APPLICATION Min. Roof Slope: 2.12 In accordance with the FBC Application: ... All;undedayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris.: All fasteners in the deck shall be. checked for protrusion and corrected prior to underlayment application. � 'Prior to beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes.. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The undertayment shall be installed With the roll length parallel to the eave, starting at the eave, and with minimum 3' side laps and minimum 6° end laps staggered min. 64from preceding course. Additionally; if applying WeatherLock®_Specialty .Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail•the underiayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush. to the top surface of the underlayment).' Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when Installed on roof slopes greater than 3:12. Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum'Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System N6.1'— WeatherLock Specialty Tile & Metal Only Roof Deck: Min.15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions -to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized .ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch tit fin caps spaced 12 o_c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application: Maximum Design -142.5 psf Pressure: OCR14002.8a FL8777--R11 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G204. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation; recommended use, or other product attributes that are not specifically addressed herein. r I M.CR '- - TECHMCAL SERVICES, LLC GENERAL LIMITATIONS . OWENS CORNING ROOFING AND ASPHALT LLC Weathed ockO Self -Sealing Ice & Water Barriers 1) This evaluation report is not use in the HVHZ. 2) Fire Classification. is not within the scope of this evaluation. 3) Installation of the evaluated .produIct shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies -exist -between these sources, the more'restrictive and FBC compliant installation detail shall prevail: 4). The roof deck shall be constructed of closely fitted plywood -sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. . 7); The underlayment may be used as described in other current FBC product approval documents. '8) Design wind load, pressures shall ,be determined for components and cladding In accordance with FBC 1609.; 9) The. roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly: 11) All products. listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3: COMPLIANCE. STATEM ENT The products -evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6"' Edition (2017) as evidenced in the referenced documents submitted by the.named manufacturer. ,,,,��PY R, p��i,� EN 2017.10.11 No 74021 = 09:06:29 � I Wu/T.4b.g0.M 04'00' STATE OF %0 '• ,� �.� Zachary R. Priest, P.E. '���`''• O R 1 p'• N_�� Florida Registration No. 74021 � N A . Organization No. ANE9641 . CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products underthis evaluation. i CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. P.riest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing.products under this evaluation. Zachary R. Priest; P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of.the product. END OF REPORT OCR14062.8a FL9777-R11 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC-of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.