HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGFlorida Building Code Onli�- Page 1 of 4
SCANNIED
BY
St Lurie. �W
d
BCIS Home ' Log In i User Registration Hot Topics } Submit Surcharge Scats B. Facts Publications { FBC Staff { BCIS Site Map' { -Unks �- Search {
Or*
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application O t.> Application Detail
FL # FL14645-R3
Application Type
Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
W.
Metal. Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
(502)855-4300
dstermer@metaisales. us.com
David Stermer
dstermer@meta Isales.us:com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
,? Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
i the Evaluation Report
Florida License. PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/27/2026
Validated.By Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL14645 R3 COI CertificateIndeoendence odf
Standard
FM 4470
TAS 125
U L 1897
UL 580'
Year
2012
2003
2012
2006
File Copy
https://www.floridabuilding.orglprlpr app dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
r
i
Product Approval Method
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Drnd!-r*-
09/09/2017
09/14/2017
09/15/2017
12/12/2017
Model, Number or Name
Description
5.1
r
2.5" Corrugated
Min. 26 ga., 21.33" wide coverage through fastened roof
panel over min. 19/32" thick plywood deck.
ts of Use
Installation Instructions
FL14645 R3 II EvaivationReoorl:0182 1 Ddf
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86.0
Uplift load of 82.3 psf at fastener spacing of 36" o.c.
Evaluation Reports
FL14645 R3 AE EvaludtioDReportC2182 i Ddf
Other:
and 86.0 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
14645.2 5V-Crimp Min. 26 ga.; 24 wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel flat.
Limits of Use installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReDortC2182 2.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A%-149.6 Evaluation Reports
Other: Uplift load of 84.5 psf at fastener spacing of 24" FL14645 R3 AE EvaluationReoortC2182 2:odf
o.c., 131.3 psf at fastener spacing of 18" o.c. and 149.6 psf Created by Independent Third Party: Yes
at fastener spacing of 12" o.c.
14645.3 5V-Crimp
Min. 26 ga., 24" wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel rib.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL14645 R3 II Eva] uationReoortC2182 3.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-196.75
Evaluation Reports
FL14645 R3 AE EvaluationReDortC2182 3.odf
Other: Uplift load of 41.6 psf at fastener spacing of 36"
o.c., 74.8 at fastener spacing of 16" o.c. and 196.75 psf
Created by Independent Third Party: Yes
psf
at fastener spacing of 8" o.c.
14645.4 SV-Crimp Mina 26 ga., 24" wide through fastened roof panel over min. I
15/32" thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReoortC2182 4.1)df
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5 Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c. FL14645 R3 AE EvaluationReoortC2182 4.odf
and 172.5 Dsf at fastener spacing of 6" o.c.' Created by Independent Third Party: Yes
645.5
Aluminum Classic Rib
Nom. 0.032" thick, 36" wide, aluminum through fastened
roof panel over min. 15/32" thick plywood deck or 7/16"
[Approvedfor
thick OSB.
mits of Use
Installation Instructions
Fuvov5 3 11 t a ogC2 82 S
use in HVHZ: No
pproved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-120
Other: Uplift load of 30 psf at fastener spacing of 36" o.c.
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 S.Ddf
and 120 psf at fastener spacing of 6" o.c.
I Created by Independent Third Party: Yes
14645.6 Aluminum Vertical Seam Nom. 0.032" thick, 16" wide, aluminum standing seam roof
panel over min. 15/32" thick plywood deck or 7/16" thick
OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II Eva luationRenortC2182 6.1)df
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.05 Evaluation Reports
Other: Uplift load of 41.6 psf at clip spacing of36" o.c., FL14645 R3 AE Eva IUatlonReoortC2182 6.odf
71.0 psf at clip spacing of 12" o.c. and 97.1 psf'at clip Created by Independent Third Party: Yes
spacing of 12" o.c. with sidelap adhesive.
https://www.fl.oridabuilding.orglprlpr app dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
Florida Building Code Onlis' Page 3 of 4
14645.7 1 Aluminum vertical Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant. N/A
Design Pressure: +N/A/-162.0
Other: Uplift load of 41.6 psf at clip spacing of 36" ox.,
100.2 psf at clip spacing of 12" o.c. and 162.0 psf at clip
spacing of 12" o.c. with support strap.
Nom. 0.032" thick,,16" wide, aluminum standing seam roof
panel over min. 19132" thick plywood deck
Installation Instructions
F' 14645 R3 II EvaluationReportC2182 7.pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 7 odf
Created by Independent Third Party: Yes
14645.8 Classic Rib Min. 29 ga:, 36" wide through fastened roof panel over min.
15132" thick plywood deck.
Limits:of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-91
Other: Uplift load of. 41.5 psf at fastener spacing of 48" o.c.
and 91 psf at fastener spacing of 6" o.c.
14645.9 1 Classic Rib
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-133.9
Other: Uplift load of 74.8 psf at fastener spacing of 36"
o.c., 92.3 psf-at fastener spacing of 24" o.c. and 133.9 psf
at fastener spacing of 18" o.c.
Installation Instructions
FL14645 R3 II EvaluatfonReportC2187 8 pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third. Party: Yes
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 8.gdf
Created by Independent Third Party: Yes
Min. 26 ga., 36" wide through fastened roof panel over min.
19/32" thick plywood deck.
Installation Instructions
FL14645 R3 II EvaluationReportC2182 9 odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 9.12df
Created by Independent Third Party: Yes
14645.10
Classic Rib
Min. 29 ga., 36" wide through fastened roof panel over min.
7/16" thick OSB deck
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL14645 R3 II- EvaluationReportC2182 10.ndf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-135.0
Other: Uplift load of 45 psf at fastener spacing of 24" o.c.
Evaluation Reports
FL14645 R3 AE EvaluationReoortC2182 10.pdf
and 135 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.11
Classic Rib
Min. 29 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL14645 R3 II EvaluationReoortQ182 ll.pdf
'PE
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.5
Other: Uplift load of 68.4 psf at fastener spacing of 24" O.C.
Evaluation Reports
FL14645 R3 AE EvaluationfleoortC2182 11 pdf
and 138.5 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
14645.12 j Image II
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-86.55
Other: Uplift load of 20.8 psf at fastener spacing of 24"
o.c., 63.5 psf at fastener spacing of 6" o.c. and 86.55 psf at
fastener spacing of 6" o.c. with sidelap adhesive.
Min. 26 ga., 16" wide concealed fastened roof panel over
min. 15/32" thick plywood deck or 7116" thick OSB.
Installation Instructions
FL14645 R3 II EvaluationReportC2182 12.pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 12.pdf
Created by Independent Third Party: Yes
14645.13
PBR-Panel or R-Panel
Min. 26 ga., 36" wide through fastenedroof panel over min.
15/32" thick plywood deck.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL14645 R3 II Eva] uationRenortC2182 13.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-131.0
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
Evaluation Reports
F1 14645 R3 AE EvaluationReportC2182 13 odf
and 131.0 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.14 Pro -Panel II Min. 29 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
Florida Building Code Onlif""_' Page 4 of 4
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 113 iI Eva luationReoortC2182 14.12df
Approved for use outside, HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-71.5 Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 24" o.c. FL14645 R3 AE EvaluationReoortC2182 14'.Ddf
and 71.5 psf at fastener spacing of 12" o.c. Created by Independent Third Party: Yes
Back Next
contact Us :: 2601 Blair Stone Road Tallahassee Fl. 32322 Phone: 850-487-18
The State of Florida Is an AA/EEO employer. Comight 2007-2013 State of Florida.:: Privacy Statement ;: Accessibility Statement ;: Refund Statement
Under Florida law, email addresses are public records. if you do not want your e-mail address released In response to a public -records request, d_ o not tend
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1305. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter455, F.S. must provide the Department with an email address.if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which an be made avallable to the public. To determine if you are a licensee under
Chapter 455, F.S., please clickhem .
Product Approval Accepts—
® ® edhc
Credit Card
- Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
r-
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA. 5V-CRIMP PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.4-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer 962240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568
This report consists of
Evaluation Report (3 Pages including cover) 1%11111 flit,,
Installation Details (1 Page) v`%%% SOCKAC/-%,�e
Load Span Table (1 Page) ,.`��,�''.•�c, E N SF,�''-q,�m�
Report No. C2182-4
Date: 9.9.17
o
No 62240 a
®.Q; :cc�
5� STATE OF : ��
4l/
\��mZ,
1
•.,,0 R••, • 0- e0
Bo ALE%%
�,�.2C>
- FL 14645.4-R3
C2182-4
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7116" thick OSB or min. 15/32" thick plywood or min. 3/4' thick
wood plank (min SG of 0.42) for new and existing constructions.
Designed by others and installed as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c..
(Minimum) in the plywood field and edges. Designed as per FBC 2017.
Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or #1044 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance.
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
directory or ASTM E108/UL790 report from an accredited laboratory
ar fire ratings of this product.
Supporting Documents: UL580 & 1897 Test Reports
PR1 Construction Materials Technologies
MSMC-017-02-01, Reporting Date 9/20/13
FL 14645.4-R3
C2182-4
9.9.17
Page 3 of 3
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation
report is not applicable in High Velocity Hurricane Zone. Fire
classification is not within scope of -this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
PANEL OVERLAP
5V—CRIMP
-SEE DETAIL 2 / -SEE DETAIL 1
u n
FASTENER AT PANEL FLAT
REQUIRED FOR PANEL
ENDS ONLY.
`MINIMUM ATTACHMENT:
8d x 2.5" LONG RINGSHANK NAIL
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURER'S INSTALLATION
OR #8 x 2" LONG WOOD SCREWS
SPACED 0 6" O.C. IN THE FIELD
GUIDELINES
& AT EDGES
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
MIN. 2X_ WOOD RAFTER/JOIST/
TRUSS AT MAX, 24" O.C.
TYPICAL PANEL INSTALLATION X-SECTION
5V—CRIMP
MIN 26 GA.
UNDERLAYMENT J — OSB 7/16" THICK (MIN.) OR
DETAIL 1 PLYWOOD 15/32 THICK (MIN.)
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
UNDERLAYMENT
DETAIL 2
SV—CRIMP
MIN 26 GA.
OSB 7/16" THICK (MIN.) OR
PLYWOOD 15/32' THICK (MIN.)
PANEL FASTENER PER UPLIFT
LOAD TABLE
d
0 0
U N
ZW
Co
(noo
0
d.
ii
MJ OD
N
W 55'
JQ os
f!1 N
r Lo
w
a
GENERAL NOTES:
i. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
a
" A
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN, 26 GA. (t = 0.0191. EFFECTIVE COVERING
n
�
a' as!
and
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
N
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN' WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
T
0 a
N n
IN
ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING.
V
5, ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & HE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF HIS DRAWING & HE CODE, THE CODE SHALL CONTROL
6 DESIGNED
SEEACH
REQUIREDRAFTERS/JOISTS/TRUSSES
F RAPPLICATION N A ARE THE HE RESPONSIBILITY OF OTHERS. THERS..
1 or
METAL SALES MANUFACTURING CORPORATION
5V-Crimp Uplift Loads
(Ml in., 26 ga.)
Description
Fastener Spacing
along panel length
(in.)
Allowable Uplift
Load
Coverage width: 24"
Panel Fasteners
#9-16 or #10-14 hex head
wood screws with sealed
washer
6
172.5 _LL
9
120.0
72.0
15
18 _
60.0 _
21,
51.4
45.0.
24
27
40.0
30
36.00_-
33
32.7
36
30.0
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor- of 2.
2. Panels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current installation procedure.
3. Three or more spans condition.
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106
918 492 5992
111%jP 118111r�g
�+ SOCKq4 °'aF
Vq
No 62240
m q*�
v
STATE OFF ��
(O R Ie� P, N ewe
•L
Bala Sockalingam, Ph.D., P.E.
FL 62240