Loading...
HomeMy WebLinkAboutLETTER ROOF SPECIFICATIONSArchitecto' bic Inc February 2, 2018 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 SCANNED ST LUCIE COLN7Y BUILDING DIVISIO ' !D6 C?'�VEU-32� st Lucie County covan.. 1 tEVIB�.�'ED r3r DATE �? PLANS AND PEMIT fL U5 f BE KEPT ON Joe OR "rJQ IP1S,^��CTIc�Pd WILL BE MADE Re: Roofing specification prepared fort he St. Lucie County Building Dept. for the structure located at, 5416 Stately Oaks St., Saint Lucie County, Florida Manufacturer: Extreme Metal Fabricators, LLC. Profiles: 26 Ga. 5v Crimp: FL. #17022.1 Code: FBC 2017; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 8/12 Required Design Pressure: Zone1: -24 Zone 2: -40 Zone3: -60 Maximum Uplift Pressure: -101@ 8" o.c. Fasteners: #10 x 1-1/2" (or of sufficient length to meet 3/16" min. penetration through deck or 5/8" min. embedment into wood plank) Underlayment: Owen's Corning Weatherlock, FL# 9777.5 (self -adhering) Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thrru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. ✓.•�' •Rio A�� �ul��li'GY � c. �<<';�� ,%�,'k' +,uf�l� ully submitted,. HEQIJIRE0 rn, �G�44 MAY KN1C-0-Ec 8F.;11; IiNGRORR'!1:; . — � � COt�9��'i ��Ixi� �,�,lt.!'t'[:,�rR�"a.►��� ��.I�ru, Seal ;� AV ED`V u� .� c Inc. , . FR•PQ'G CONCEALED FAS i ENERS OR 01 ACHMENT�' ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC,Sec.1507.4.2 Palm'City, FL 34990 ST LUCIE COUNTY BUILDING DIVISION IyF �9pLi RR9nn fdED JRE'VIEW D BY DATE PLANS AND PER IIT MUST BE KEPT ON J B OR NO IP1wPFCTIQPi',":'ILL PE IIAAPE Yield strength: 50 ksi min.; Attached to min.15/3Z" plywooa of Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Tlr10 14 Corrosion Resistant Compliant: FBC Sec.1S07.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with IBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING i6" O.C. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" ax. 12" o.c., 22" o.c. 12" o.c. FASTENER SIZE . #9 #10 #10 1 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL SBO-06 & 1897-041 Test Report E[5893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/28/25 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL Fly *Design pressure margin of safety2rl Locke Bowden, P.E. does not have, not will acquire a financial intt �i►1 L� F�eq pq m�iWfacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by a jW' coj;panVj)m961fhlturea, or distributing products under this report. + • %f THESE;;,, !�f,i i'?,�� 1'�I�R►; z QTENERS OR ATTACK ARE 10N. RFQUIR€`-0 FILIO R-12[41(1-0i1S THAaT MAY bE N r-0..r''18 " 111, 1I1� 0 R 0 R R 1Q n`_ COLIPIX Ve 1 I I`I AUL f V_��I�I�J.� AL DOES,, S TE +� �w B TH PI�EN1. Fc�l,lo�:. `,;. RESPONSIBILITY OF THE '•.,;'s,-oN �,a CONTRACTOR OF RECORD FL17O22.1 5V Crimp (26GA Steel); 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. — Fasteners- #9 x 1-112' Min. or. #10 x 1-11T Min. parTab/e A' for Row 5-V Crimp Roof Panel Spacing and Design Pressures Hex Washer Head Wood Screws Deck 15132" or greater Plywood, or Mod plank 24" l 12" 1� oFnoNALsiRlkTKM Parcel Profile Nominal 12" 1 Nominal 12" O.C. I O.C. Fasten 9 x 1-1/2" Min. or #10 x 1-1/2" Min. per able "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck 15/32" or greater Plywood, or -Wood plank