HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS' I
Ajunoo aionj is
A
OONNV 9
IF
Professional Regulation
BCIS Home I Log In I User Registration- Hot Topics Submit Surcharge IStats Br Facts Pubilcatlans I FBC Staff i BCIS Site Map j Links I Search i
Or*
product Approval
USER: Publlc User
,P�r due Approval Menu > Product ar Aooiltatlon Search > Application List > Appticatlon Detail
FL # FL9777-Rhl
Application Type Revision
Code Version 2017
Application Status Approved)
i
I
Comments
Archived ❑
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Owens Coming
One Owens Coming Parkway
Toledo, OH 43659
(740)4047829
greg.kee[6.r@owenscorning.com
Greg Keeler
greg.keele'r@owenscornlng.com
ST LUCIE COUNTY
BUILDING DIVISIO`
F COP, COPuiPI d M
EIEVIEVVED [BY
DATE — —tO
PLANS AND PENMIT
KILT& i UE KEPT ON JOB OR
NG IiqvldR�,Tl0N IVILl L Leg M8r,E I
THHE rKi.i0 N
ARF
�qee/j�� LL
HF:llUNIE0nl I^�I,i�Illi�Jr''r�11 :� ��Iail
COMPLY VVI rN AU. APPI.lCi U!�
CONCEALED PA TENBRS OR AiiAOU NTS
ARE THE RESPONSIBILITY Or THE
I
Roofing i CONTRACTOR OF RECORD
Underlaymll nts
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Zachary R. Priest
I
PE-74021
UL LLC
12/31/2020,
Locke Bowden
10 Validation Checklist - Hardcopy Received
FL9777 R11 COI OCR14002 8a 2017 FBC Evaluation Report
Weather -lock Non-HVHZ.Ddf
Referenced Standard and Year (of Standard) standard
ASTM D 1970
ASTM D 226
ASTM G 155
TAS 103
UL 1897
Equivalence of Product Standards
Certified By
Year
2015
2009
2005
1995
2012
Sections from the Code
I ��
,I
Product Approval Method Method I Option D
Date Submitted 10/11/20.17
Date Validated 10/11/2617
Date Pending FBC Approval 10/17/20,17
Date Approved 12/12/2617
Summary of Products I
� l
FL # I Model, Number or Name Description
9777.1 Weatherlock G Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 1131 II OCR14002 8a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.pdf
impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
Created by Independent Third Party: Yes
9777.2 Weatherlock G (High Tear) Weatherproofing Underlayment
Limits of Use installation Instructions
Approved for use in HVHZ: No J Fl 9777 1111 II OCR14002 8a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.pdf
Impact Resistant: N/A iVerified By: Zachary R. Priest PE-74021
Design Pressure: N/A ;Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports - -
9777.3 Weatherlock MAT
Limits of use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
other: See evaluation report for limits of use.
Third Party: Yes
I Underlayment
Instructions
By: Zachary R. Priest 74021
by Independent Third Party: Yes
Third Party: Yes
9777.4
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9777 1131 II OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Design Pressure: N/A
Other: See evaluation report for limits of use.
Evaluation Reports
FP9777 Rli AE OCR14002 8a 2017 FBC Evaluation Report
W.eathedock Non-HVHZ.Ddf
Created by Independent Third Party: Yes
9777.5 Weatherlock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 Rj 1 II OCRt40028a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.Ddf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation. Reports
9777.6 Weatherlock Metal
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Third Party: Yes
Weatherproofing Underlayment
Installation Instructions
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL97' OCR14002 8b 2017 FBC Evaluation Report
I
9777.7 i Weatherlock Specialty Tile & Metal
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-142.5
Other: See evaluation report for limits of use.
Weather
ock HVHZ.nd
Created lby Independent Third Party: Yes I
Weatherproofing Underlayment
Installation Instructions
FL9777 RI II QC1114002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pddf
Verlfied By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 1111 AE OCRI4002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
I
Back Next
i
Contact Us;; 2601 Blair Slane Road, Tallahassee _FL 32399 Phone: 850-487-182
The State of Florida Is an AA/EEO employer. Coovrlaht 2007-2013 State of Florida,:: Privacy Statement :: Accessiblllty Statement :: Refund Statement '
i
Under Florida law,. email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emails provided may be used for offlclal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click Here .
Product Approval Accepts:
Credit Card
Safe
i
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Cerifficate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
i
FLORIDA BUILDING CODE, C EDITION (2017)
I '
Manufacturer: OWENS CORNING ROOFING AND, ASPHALT LLC Issued October 11, 2017
1 Owens Coming Parkway
Toledo, OH 43657
i
(800)438-7465 j
www.owenscoming.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory. Underlayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
Ent&
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
NEI-039-02-01 I
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01 I
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-02-02 I
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)'
OCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237-02-01
I
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
0CF-252-02-01 I
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (rST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 1881
2012
ICC-ES AC 48
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1 ;
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01 I
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (17ST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09. Type I and II
OCR14002.83 FLW7-1111 1 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply wamanty, installation, recommended use, or other product attributes that are not
speafically•addressed herein.
i
C R K OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
TECHNICAL SER`VICEs, LLC
PRODUCT DESCRIP noN AND LIMITS of USE
WeatherLock® G
WeatherLock® G is an ASTM D 1970j self-adhesive underlayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
I
WeatherLock® G is permitted to be 'used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
i
WeatherLock® Mat
WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, 7)Q
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of aft x 66.7 ft.
i
WeatherLock® Mat is permitted to be�used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings.Exposure on the roof deck shall be limited to a
maximum 30 days.
i
WeatherLock® Metal
I
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass) mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. IExposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock® Specialty Tile & Metal is I an ASTM D 1970 self-adhesive underlayment
WeatherLock®
Specialty Tile & Metal
constructed from SBS modified asphalt land surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3 ft x 71.3-ft.
Houston, T))
��
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BOND'rm Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck sI hall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete file installations
without battens. Tile shall be stored on !,battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per shack.
WeatherLock® G (High
WeatherLock® G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type 11 roofing felt and ASTM D 1970 self -adhering polymer
(Houston,
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3ft x 65-ft.
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-R11 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
TECHNICAL SERvims, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 in accordance with the FBC
Application: AM underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, ,and free from any irregularities and debris. All
fasteners in the deck shall be checked; for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The undedayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6-ftfrom preceding course. Additionally, if
applying WeatherLock® Specialty Tile ;& Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLbck® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated usingia 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No 1 — WeatherLock Specialty Tile & Metal Only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions tc the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/84nch 10 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-Rl l Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl-ock® Self -Sealing Ice & Water Barriers
1) This evaluation report Is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood
5) The space under the deck area shall be properly ventilated
6) All side lap seams shall be installed to shed water from the
7) The underlayment may be used as described in other currE
'8) Design wind load pressures shall be determined for con
1609.
9) The roof deck shall be designed by others in accordance�l
load pressures for components and cladding. I
10) Maximum Design Pressures for a given underlayment
sheathing for new or existing construction.
in accordance with the FBC requirements.
deck.
nt FBC product approval documents.
iponents and cladding in accordance with FBC
with FBC requirements to resist the design wind
shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code a Edition (2017) as evidenced in the referenced documents s'I bmitted by the named manufacturer.
`���tu t u Urrrr�
R, pE IV
y���
No 74021
�13 •• STATE OFOR
'•�
•.
CERTIFICATION OF INDEPENDENCE
I... 2017.10.11
I
09:06:29
i
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
I
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
I
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in ;any company manufacturing or distributing products
under this evaluation.
I
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
I
OCR14002.8a FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein. 1,
Arch itecto'nic Inc
February 1, 2018
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
i
i
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure
located at, 741 SE Solaz Avenue., Saint Lucie County, Florida
Manufacturer:
Extreme Metal Fabricators, LLC.
Profiles:
1" Nail Strip 26 GA. Steel' Roof Panel, FL. #17022.5
Code:
FBC 2017; Section R 9051.10
Wind Speed:
160 MPH; Ultimate Design Wind Speeds
Exposure:
B
Mean Roof Height:
30' Maximum
Pitch:
1.5 / 12 Minimum
Required Design Pressure:
Zone1: -26.0 Zone 2: -41.0 Zone3: -69.0
Maximum Uplift Pressure:
Zone 1 & 2 -101@ 8" o.c.�
Fasteners:
#10 x 1" (or of sufficient length to meet 3/16" min. penetration through
deck or 5/8" min. embedment into wood plank)
Underlayment:
Owen's Corning Weatherlock, FL# 9777.5 (self -adhering)
Roof Decking:
Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
��3fy6a'.. ?,°' ..i � � . 1, f�• e 9 "`p^�..�.� ,
Mi6h6d[e5eal,
Archifieec'n`iG lnc
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1