Loading...
HomeMy WebLinkAboutLETTER ROOFING SPECIFICATIONSArch itecto"O' ic Inc SCANNED - FILE CO A By Sk ruiulti U i� - February 14, 2018 RECEIVED FEB 16 2018 Permitting Department Saint Lucie County Building Department St. Lucie County Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 i Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 191 SE El Sito Ct., Saint Lucie County, Florida Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Pitch: Required Design Pressure: Maximum Uplift Pressure: Base: Ply Sheet: Cap: Roof Decking: Polyglass USA' Modified Bitumen Roof System, FL #1654-1122 FBC 2017; Section 1507 160 MPH; Ultimate Design Wind Speeds B 30' Maximum 1 /12 Minimum Zone1: -26.0 Zone 2: -41.0 Zone3: -57.0 -90 psf SBS-SA (self- adhering) (Optional) One or more Elastoflex SA V Base (self -adhering) SBS-SA, SBS-TA, APP-SA, APP-TA (self -adhering) Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. '(soect, y subm M�GH S_ ael Sea .,•A 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1