Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM4• SCANNED FILE COPY FLCPlOAOQPAqrrA5N"1 OF Business ' Professional Regulation St Lucie County User Registration Hot Topics Submit surcharge Stats & Facts Publications I F13C Staff I BCIS Site Map Links Search BCIS Home I Log In b,p a �/►j Product Approval Ia USER: Public user RECEIVED Product Approval Menu > Product or Application Search > Aoplicatlpn Llst> Application Detail FEB 16 2018 FL # FL1654-1122 Application Type j Revision Permitting Department Code Version 2017 St. Lucie County Application Status Approved Comments i Archived I� Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@ polyglass. com Quality Assurance Representative Arlel Lender Address/Phone/Emall 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALend er@polyg lass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer EJ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE 0 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL1654 R22 COI 2017 01 COI Nieminen odf Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL 1897 2012 t EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 Street TRINITY ' ERD 35oxforld, Cr 06478 (203) 262-9245 EVALUATION REPORT Polyglass USA, Inc. I Evaluation Report P9290.02.08-R20 150 Lyon Drive FL1654-R22 Fernley, NV 89408 Date of Issuance: 02/11/2008 (570) 384-1230 I Revision 20: 09/12/2017 SCOPE: This Evaluation Report is issued under Rule 1161G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6"' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems I LABELING: Labeling shall be in accordance ;with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code !requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 58-page Appendix. Prepared by: i Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE2983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 09/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any companymanufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS. and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 3. REFERENCES: gniiv Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-111 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4476/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical,Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical'Prope rties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-Ri 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-Ri 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 ERD (TST6049) Physical Properties P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 ERD (TST6049) Physical Properties P39520.09.14-2 09/11/2014 ERD(T5T6049) FM 4470/4474 SC6160.11.14 11/10/2014 ERD (TST6049) Physical Properties PLYG-P45440SC.03.15-1 03/31/2015 ERD (TST6049) Physical Properties SC5170.05.15 05/08/2015 ERD (TST6049) FM 4474 SC8085.05.15 05/19/2015 ERD (TST6049) Physical Properties SC5170.12.15 12/29/2015 ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016 ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 ERD (TST6049) FM 4470/4474 PLYG-SC10815.07.16-RI 09/23/2016 ERD (TST6049) UL1897 PLYG-SC12025.10.16 10/12/2016 ERD (TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 ERD (TST6049) FM 4470/4474/UL1897 PLYG-SC13235.01.17 01/17/2017 ERD (TST6049) FM 4474/UL1897/TAS 114 PLYG-SC13920.05.17 05/30/2017 ERD (TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-1 05/30/2017 Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 2 of 6 Entity ERD(TST11294) ERD(TST6049) ERD(TST6049) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) Miami -Dade (CER1592) Miami -Dade (CER1592) UL LLC (QUA9625) 4. PRODUCT DESCRIPTION: Examination FM 4474/UL1897/TAS 114 FM 4474/UL1897 FM 4474/TAS 114 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/,4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties Physical Properties Physical Properties Physical Properties TAS 114' TAS 114. TAS 114 TAS 114 TAS 114 HVHZ Compliance Proposal for Review Quality Control Reference PLYG-CTL13945.05.17-3 PLYG-SC1394S.05.17 PLYG-SC15760.09.17 2W7A7.AM OD3A3.AM 2DOAO.AM 2 D5A9.AM 3006646 3001334 3001334 3000857 3004091 3CO6115 3012321 3014692 3014751 3007170 3019317 3020703 3018332 3023368 3024594 3023458 3030668 3032172 3049631 3057029 PUSA-062-02-01 PUSA-061-02-02 PUSA-064-02-02 PUSA-062-C2-02 PUSA-188-02-01 PUSA-188-02-02 PUSA-188-02-03 PUSA-202-02-01 PUSA-202-02-02 Various NOAs 10-0823 Service Confirmation, R14571 TRINITY ERD Date 05/30/2017 OS/30/2017 09/11/2017 08/04/1994 04/04/1997 12/23/1998 06/22/1999 01/04/2000 01/25/2000 02/15/2000 01/12/2000 01/12/2000 05/02/2001 07/29/2002 08/05/2003 08/27/2003 01/13/2004 06/30/2004 07/30/2004 01/31/2006 03/20/2006 05/23/2006 07/18/2006 09/12/2007 06/12/2009 04/21/2014 02/02/2017 12/04/2007 01/28/2008 02/27/2008 12/04/2008 02/08/2017 02/08/2017 02/08/2017 05/17/2017 05/17/2017 Various 10/12/2010 Exp.10/06/2018 This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1:.ROLL-GOODS FORPOLYGLASS MODIFIEMBITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R20 Certificate of Authorization N9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 3 of 6 TRINITY ERD TABLE 1(CONTINUED): ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type SBS Membranes Polyglass HT; Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase,Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I SBS Membranes Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS (sand or poly -film backed) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film backed) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex'G ASTM D6222 G I Polyflex,G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/22/2017 Page 4 of 6 TRINITY ERD 5.7 For mechanically attached insulation. or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with' an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirement's for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 224 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of ;resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet:1-52 or Testing Application Standard TAS 124. 1 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 611520-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate ofAuthoriiation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 5 of 6 I TRINITY ERD 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non-Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; ➢ PG700QS (Quick -Set) High Quality Elastomeric,Roof Coating or KM Acryl 25-QS (over granule -surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick -Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (over granule - surfaced APP or SBS only); ➢ Polybrite 90 High Solids Silicone Roof Coating; ➢ Polybrite 95 Silicone Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate afAutharization #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 6 of 6 VA TRINITY ERD TABLE 11F62: WOOD DECKS- NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PIATEs), BONDED ROOF COVER . System Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) Type Fasten Attach Base Ply Cap (PA SELF -ADHERING BASE PLY: Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-Inch o.c. In 4-Inch lap and 12-Inch o.c. In two SBS-SA SBS-SA, APP-SA, SBS- _52.5- W136 Inch plywood (poly -film top) or Trufast 3" Metal l nsulati6n Plate with Trufast HD (2), equally spaced, staggered center rows TA, APP-TA Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast 1114 12-Inch o.c. In 4-Inch lap and 12-Inch o.c. In two PoWex SA Base APP TA -52.5- W-137 Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows Min. 19/32- Elastobase, Elastabase P OMG Flat Bottom Plates (square) with'Roafgrlp H32 12-Inch o.c. in 4-Inch lap and 12-Inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- TA, APP-TA _60.0• W-13 8 Inch plywood (poly -film top) (2), equally spaced, staggered center rows W-139 Min. 19/32- Elastabase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip 012 12-Inch o.c. in 4-Inch lap and 12-Inch o.c. In two (2), equally spaced, staggered center rows Polyflex SA Base APP TA -60.0- Inch plywood 1 (poly -film top) TABLE 16: WOOD.DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Roof Cover (Note 25) MDP (PANo. Joint Treatment Base Ply Ply Cap Ply Deck (Note 1) Primer Min. 15/32- SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- _90.0 W-140 Inch plywood None None TA, APP-TA TA, APP-TA W-141 Min. 15/32- (Optional) PG100 None Polyflex SA Base (Optional)APP-TA APP-TA -90.0 Inch plywood Min. 15/32- SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP•SA, SBS- 97 5 W 142 Inch plywood PG300 None TA, APP-TA TA, APP-TA Min. 15/32- Plywood Joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97 5 W-143 Inch plywood (Optional) PGS00 place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA Min. 15/32- SBS-SA (Optional) SBS-SA, APP-SA, SBS- -105.0 W-144 inch plywood In WB-3000 None 7A, AP; -TA Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- .135.0 W-145 inch plywood (Optional) PG300 place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP•TA Min. 15/32- Plywood Joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional) APP-TA APP TA -135.0 W-146 Inch plywood (Optional) P6100 place to create continuous bond. Exterior Research and Design, LLC d/b/a Trinityl ERD Evaluation Report P9290.02.08-R20 for F1.1654-1122 Certificate of Authorization H9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2027 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-V30 Appendix 1, Page 21 of 58