HomeMy WebLinkAboutPLAN JOB SPECIFICATIONSGENERAL NOTES 160E ( ULT )
A. Wood:
1. All lumber on or below grade shall be ACQ Pressure Treated Southern Yellow Pine 02 Grade (Fb - 1,000 psi min.)
2. All lumber above grade (non -decking) shall be Southern Yellow Pine 02 Grade
3. All framing lumber shall be hem-fir
-2 Cade orequivalent
9
4. Wood structural panels obeli be e I structural sheathing p 'h Mtn. thickness, exposure g
5. In all Instances where aluminum comes into contact with pressure treated wood, provide dielectric separation
B. Concrete: N/A (I. Site Preparation : For Existing Concrete)
C. Masonry: N/A
D. Aluminum
1. All structural aluminum conforms to the minimum requirements of 6005 - T5 For alloy and temper:
2. All structural aluminum work conforms to "Part I -A - specifications for aluminum structures - allowable stress design:
or "Part I-B - Specifications for aluminum structures - building load and resistance factor design" of
The Aluminum Association, Inc. Seventh Edition, Effective January 2000
3. In all Instances where aluminum comes into contact with steel, or pressure treated lumber provide dielectric
separation
E. Glass
1. Glass units consist of two panes of 1/8" thick tempered glass with an argon fill
2. Glass conforms to ASTM E1300
3. All clear Argon roof glass has the following min, properties: Ashrae Winter U Value - ,25
Ashrae Winter R Value = 4.0
Solid Wall Panels
1. Aluminum panel skin is Alloy 3105 - H14/1425 and Is 0.024" thick min.
2. Panel Core Foam is Preformed Expanded Polysterene Board (EPS),
F. Sealant .. 1. All sealant conforms to TT-5-001543-A, TT-5-002306, ASTM C - 1320 type S, Grade NS, Class 25,
Sealant to be used for structural adhesion 4 to prevent water Intrusion.
G. Gaskets .. 1. All gaskets are co -extruded and are non -migratory.
H. Fasteners
1. All lag bolts shall conform to stainless steel type 300 18 - 8, with standard flat washer unless manufacturer
galvanized bolts specifies for use with ACQ pressure treated wood
2. Hex bolts has be ASTM A325, plated with standard flat washers and nuts
3. All concrete arrows shall be 4" x 2 I@" min., Simpson, HIM, Rawl, Tapcon, Redhead, Dynabolt, or approved equal
4. All metal ties and associated accessories shall be hot dipped galvanized
5. All lag bolts shall have a minimum embedment of 8x bolt diameter into structural Framing (G - .42 min.)
6. Lag bolts and screws Into wood framing shall be provided with pilot holes having a diameter
not greater than 10 percent of the thread diameter of the bolt or screw. All lag bolts and
screws shall be Inserted to pilot holes by turning and under no circumstances by driving with a hammer.
'1. All expansion anchors shall be designed in accordance with the specific manufacturers requirements
and allowable loads and shall only be applied in conditions acceptable to manufacturer
8. All fasteners Connecting aluminum components or pressure treated lumber are stainless steel
type 300 18 - 8 unless manufacturer galvanized bolts specifies for use with ACQ pressure
treated wood, or otherwise noted on plans
S. All fasteners shall comply with ASTM A153
10. All connector& shall comply with ASTM A653 Class G - IS
I. Site Preparation
1. Foundation ayateme must be placed on clean, compacted,
termite -treated fill/soil with vapor barrier.
2. Existing Foundation, footing and slab if noted on the Floor Plan have been
evaluated 4 found acceptable For this application.
J. Reference Standards:
ASTM E 119... ASTM E 1300... ASCE 1-10... AAMA/NPEA 2100-02
3.0: Use aild occupancy category 2
4.0: All fenestration products comply
5,0: All wall and roof panels and assemblies comply
6.0: Does not apply to category 2
1.0: All applicable provisions comply
K. Florida Product Approvals (provided by contractor):
"SEE PRODUCT APPROVAL AFFIDAVIT"
All listed product approvals have been reviewed and accepted
by the engineer of record.
L. DESIGN LOADS:
This structure has been designed in accordance with, 4 meets the
requirements of the Florida Building Code, Residential 2011 6th Edition
4 Amendments 4 ASCE 1-10 per Section R301.2.1.1, 4 all applicable sections
of R301 design Criteria.
Design Criteria:
Design Roof Load: Dead Load (Addition): 10 PSF
Live Load (Roof): 20 PSF
Wind Velocit (ULT)' I60MPH (3 aec ust) Ex osure' B Risk Categor • II
JOB SPECIFIC NOTES
GENERAL NOTES
I: CONSTRUCTION TO FOLLOW THE REQUIREMENTS OF THE FLORIDA
BUILDING CODE 2011 6TH EDITION 4 WIND CRITERIA PER ASCE 1-10.
2: NO EGRESS OPENINGS FROM ANY BEDROOM / SLEEPING ROOM
HAS BEEN COMPROMISED BY PROPOSED SUNROOM
3: NEW SUNROOM HAS IMPACT RATED OPENINGS, THERFORE
EXISTING OPENINGS LEADING TO NEW SUNROOM ARE NOT
REQUIRED TO BE SHUTTERED - PER FBC 2011 6TH EDITION
4: ELEVATIONS ARE REPRESENTATIVE ONLY
SLAB/FOUNDATION NOTES , .
EXISTING SLAB 4 FOUNDATION TO REMAIN
ELECTRICAL NOTES
1: ANY ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2014
NATIONAL ELECTRIC CODE 4 CONFORM WITH THE FBC 4 ALL LOCAL CODES.
2: ALL ELECTRIC COMPONENTS SHALL BE TIED TO EXISTING
ELECTRIC SERVICE 4 PANEL SPARES
3. PLACEMENT OF ALL ELECTRIC COMPONENTS BY
LICENSED ELECTRICAL CONTRACTOR
4. EGRESS LIGHT REQUIREMENT: MEW LIGHT 4 SWITCH OR EXISTING LIGHT
OR SOLAR POWERED LIGHT MAY BE USED)
S. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL WORK.
SUNROOM CATEGORY "ll" REQUIREMENTS
I. PER AAMA/NPEA/NSA 2100-02 THIS STRUCTURE MEETS
CATEGORY "II" REQUIREMENTS
2: CATEGORY "II" SUNROOMS PER AAMA/NPEA/NSA 2100-02
SECTION 1.0 GENERAL REQUIREMENTS FOR SUNROOMS
SUBNOTE 1.1 ELECTRICAL REQUIREMENTS
SUSNOTE 1.1.1 : (EGRESS LIGHTING REQUIRED ONLY)
SUBNOTE ',7,2 : EXCEPTIONS: CATEGORY II SUNROOMS
ARE EXEMPT FROM REQUIREMENTS FOR RECEPTACLE
OUTLETS.
4LL AREAS OF ROOF CONNECTIONS TO BE SEALEL
FLASHED AS REQUIRED FOR WATERPROOFING
014A x ROOF SCREW w/ MIN 1 1/2 EMBED, APPLY STRUCTURAL
( PER PANEL SIZE ) WITH NEO-WASHER SEALANT TO ROOF
SCREWS a 8" O.G. MAX. PER PANEL 4 POLY PANEL
FLASHING
(2) PT 2 x 6 RIDGE SHOE PLATE 4
a w/ (2) 3/8" LAG SCREWS - SEALANT
MIN 1 1/2" EMBED. s EACH TRUSS - MAX 24" O.C. \
ATTACH SOLID PANEL FILL
EXISTING ROOF
ON FRONT 4 SIDES
TO REMAIN
w/ EXTR'D .OSO ALUM
RECEIVER CHANNEL
FOR SOLID PANEL
CUT
EXISTING STRUCTURE
SCREWED TO ROOF PANEL
EXISTING
w/ 014 x 3/4" TEK SCREW
ROOF O.H.
SOLID PANEL SCREWED TO
a B" O.C.
NEW
RECEIVER CHANNEL
SCREWED TO EXISTING ROOF
SUNRooM
w/ s14 x 3/4" TEK SCREW
w/ -14 x I" WOOD SCREWS
SEE PLAN
a 12" O.C. FRONT SIDE
e 8" O.C.
POLY PANEL ROOF
TO EXISTING ROOF CONNECTION DETAIL
NOT TO SCALE
y g p y
Building Height: < 30' Mean Roof Height: <15'
Enclosure Type: Sunroome - Enclosed
Max Components and Cladding Pressures:
Roof Zone I: +12.2/-32.3 par... Roof Zone 2 4 3: +12.2/-38.2 per
Wall Zone 4: +21.5/-30.2 per... Wall Zone 5: +21.5/-33.5 per CUT EXISTING
ROOF O.H.
M. Abbreviations
The following [let of abbreviations Is not Intended to represent all those EXISTING RODE
used on these drawings, but to supplement the more common abbreviations o 2" SOLID PANEL
used: TYP. - Typical SIM. - Similar UNO. - Unless Noted Otherwise
CONT. - Continuous V.I.F - Verify In Field
h rK
N, Responelbility EXISTING
I. All site work shall be performed by a licensed contractor in accordance RESIDENCE..
with applicable building codes, local ordinances, etc, r'- 4 OPENINGS
2. Contractor shall verify all dimensions, and details,, notifying engineer of any
PTO REMAIN
discrepancies between drawings, fabricated Items, or actual field conditions
3. These drawings represent the acceptability of the "Sunroom" room addition '`
elements as provided by the contractor
4. All details on these drawings are engineered based on information`
provided by the contractor _EFT ELEVATION
5, Refer to the manufacturers shop drawing for further details SCALE: 1/4" - 11-0"
6. Any details not shown are to be engineered in
accordance with standard engineering Practices.
O. Miacellanecue
I. This structure conforms with Catagory 11 Sunroom requirements.
2: Catagory II Sunroome per AAMA/NPEA/NSA 2100-02
CUT EXISTING
Section 1.0 General Requirements for Sunroome
ROOF O.H.
Subnote 1.1 Electrical Requirements
d
Subnote 1.1.1 (Egress Lighting required only)
EXISTiNCs ROOFFFF
Subnote 1.1.2 : Exceptions: Catagory II Sunroome are
+/ n„
exempt from requirements For receptacle outlets.
SOLID PANEL
O.H.
EXISTING y
RESIDENCE
4 OPENINGS a "
TO REMAIN
SOLID PANEL
RIGHT ELEVATION
SCALE: 1/4" - 1'-0"
IJ
Q
+V
EXISTING I STORY RESIDENCE
4 OPENINGS TO REMAIN
014A S.M.S. SCREW w/ 1 1/2" S.S.
NEOPRENE GASKET WASHER
TYP (1) SCREW a MAX 3" FROM EA SIDE 4
u
a
MAX 1 - fl) O Y-
O.C. TTL OF PER P L PANEL
SEALANT
!EXTERIOR
a
FRONT EDGE w/ MIN. I EMBED INTO BEAM
ONLYK-,_.�GGABLE END SIDES a MAX 12" O.G.
\s12 x 3/4" y SEE WALL SECTION
SMS s FOR ADDITIONAL
SCREW Is, DETAILS
e I6" O.G. 9
MAX, g
EXTR'D ALUMINUM
APPLY STRUCTURAL
UNIVERSAL GUTTER/
SEALANT
GUTTER FASCIA
EXTR'D ALUMINUM
3" x 3" x 0.125" BEAM
EXTR'D ALUMINUM
1. x x x
-14 x I" TEK SCREW
.25°
- SHAPED
L -SHAPED CLIPS
(3) PER L- SHAPED CLIP
TO BEAM TTL OF (6)
EXTR'D ALUMINUM
l8J INTO COL. (4) EA
3" x 3" x 0.125" COL.
SIDE - 2 ROWS OF 2
EAVE / BEAM / COL.
I CONNECTION
SECTION
NOT TO SCALE
1411 (2) ANCHOR CLUSTER - MAX 4" SPACING
a MEETING RAIL FOR NON -IMPACT
MAX OO..C. 4 (4) ANCHOR CLUSTER FOR IMPACT
So
MAX �5" MAX
�� \ mil• 131/4"
MAX
5" MAX
ANCHORS SAME AS HEAD REQUIRED a SILL
ANCHORS - 012 SMS OR EQUAL INTO 1/8" 6063-T5 ALUM MIN.
PROVIDE 5 PITCHES MIN. PAST THREAD PLANE
TYP. HRZ. WINDOW ANCHOR DETAIL
_ NTS
TYP. ANCHOR INFO FOR SWING DOOR
014 SMS OR EQUAL INTO 1/8" 6063-TD ALUM MIN.
PROVIDE 5 PITCHES MIN. PAST THREAD PLANE
5/16" TAPCONS INTO CONCRETE MIN. 1 1/211 EMBED
el) 5 3/4" 4 II 3/411 MAX FROM CORNERS
4 12 3/4" MAX O.G. a FRAME HEAD / SILL
5" MAX FROM CORNERS 4 11 1/4" MAX O.C. a JAMBS
TYP. ANCHOR FOR SLIDING GLASS DOOR
014 SMS OR EQUAL INTO 1/8" 6063-T8 ALUM MIN,
STRUCTURE 4 012 SMS OR EQUAL INTO 1/8" ALUM
MULLIONS MIN. PROVIDE 5 PITCHES MIN. PAST
THREAD PLANE 1/4" TAPCONS INTO CONCRETE
MIN. 1 1/4" EMBED
TYP. ANCHORS IN PAIRS - 6" MAX FROM
CORNERS 4 18" MAX O.C. a FRAME HEAD / SILL
4 13 3/4" MAX O.C. • JAMBS
(4) ANCHOR CLUSTER - MAX 6" SPACING
a CIL OF STILES
FRONT ELEVATION
SCALE: 1/4" - 1'-0"
ELECTRICAL
SYMPOL
OUTLET
LIGHT
SWITCH
$
TYPICAL ALUMINUM COL. SYMBOL KEY
3 x 3 x .125 HOLLOW ALUMINUM
B 2 x 3 x .125 HOLLOW ALUMINUM
6'SLW ro'SLW 0 6'SLW
SUNROOM
IS NON -HABITABLE
4
UN-AIRCONDITIONED
SLAB/FOUNDATION NOTES
EXISTING SLAB 4 FOUNDATION TO REMAIN
3065
ro' SL W A FIR n 6' SL W
FLOOR PLAN
SCALE: 1/4" - I'-O"
SEE PRODUCT APPROVAL / NOA
FOR TYP. CONNECTIONS FOR OPENINGS
GABLE -END WALLS
CONNECT SILL DIRECTLY
TO ROOF PANEL U.N.O.
FRONT WALL SECTIONS
SEE EAVE DETAIL
FOR ROOF CONNECTION
- - 014 x 3/4"
TEK SCREW
BEAM a 16" O.C.
OR - - _ = STAGGERED
MULLION (TYP,)
APPLY BEAD
SOLID PANEL STRUCTURAL
-
_ SEALANT TYP.
SILL ill FILLER ilk
AS NEEDED (4) 014 x 3/4"
TEK SCREWS
(2) EA SIDE a
BTM OF PANEL
_ _ _ (TYP.)
MULLION 014 x 3/4"
I TEK SCREW
! • 1611 O.C,
STAGGERED
(TYP.)
FT\" ul (TYP.)
P-ER N.O.A.
71
II II II II �®
OR
SLIDER I I I A l l �� B
WINDOW TF07T TFv'-7 I FLSEE
OOR
PLAN
LLI
(TYP.)
012 S.T.S.
- �• - - I PER N.D.A.
-14 x 3/4"
TEK SCREW
MULLION a 16" O.C.
STAGGERED
(TYP.)
SILL/ U SOLID II APPLY BEAD
PANEL STRUCTURAL
KICK SEALANT TYP.
II -- - - --- Vk- -
(4) 014 x 3/4"
TEK SCREWS
SILL (2) EA SIDE a
\ BTM OF PANEL
- - - - - (TYP.)
: - - OUTSIDE
EDGE
SEE SILL CONNECTION DETAIL
WALL SECTION
NOT TO SCALE
CONTRACTOR TO VERIFY
EXACT WINDOW -41ZES
El
CUSTOM 3068
6' SL W A +/- 2' 3" FG FIR
6'5LW ID
114" x 2 1/2" FASTENERS
OUTSIDE FACE OF
INTO EXISTING STRUCTURE
EXISTING STRUCTURE / COLS. a Iro" O.G. MAX. VERTICALLY
APPLY CAULKING
BETWEEN SILL 4 WALLTAPCONS
FOR CONC. /
-12
' F^" `
PANELrt
LAG -BOLTS w/ WASHER
x 3/4" TEK SCREWS
+1�ALL r !
FOR WOOD FRAME
a RECEIVER CHANNEL
TO WALL PANEL
ID MAX 12" O.C. VERT. PLAN VIEW OeO" RECEIVER CHANNEL
ATTACHMENT TO EXISTING STRUCTURE FOR SOLID PANELS
NOT TO SCALE
INSIDE ROOM
WALL
PANEL
U 3" x 3" x O,
I 1 �
z ALUMiNUP
t _ 0
- COL.
(3) 014 x 3/4" TEK SCREWS
EACH SIDE OF COLUMN
- , !SEE SILL
CONNECTION
J FOR DETAIL
PLAN VIEW
(3) 014 x 3/4" TEK SCREWS CONT. 1.5" x 3" x .090"
CLIP TO COLUMN EXTR'D ALUMINUM SILL
TYP 3" ALUM. COL. CONNECTIONS
NOT TO SCALE
PLAN VIEW
TYP
(3) 014 x 3/4"
TEK SCREWS
CLIP TO COLUMN
TYP
(3) 014 x 3/4" TEK
SCREWS SILL TO
OUT SIDE CORNER
OF COLUMN
WIN, INSIDE ROOM
CONT.
' - 1.5" x 3" X .090"
1 I
EXTR'D ALUMINUM
SILL BELOW
d V V
x 3" x 0.125"
ALUMINUM '
COL. WALL
c+Awl'CI
TYP. 3" ALUM, CORNER COL, CONNECTION AT BILL
NOT TO SCALE
INSIDE -+ ANCHOR BOLTS a 3" MIN
ju
OF = FROM CONCRETE EDGE
c
~
ROOMrT
SILL CONNECTION t0 CONCRETE 1I
(1) 3/8" x 3 3/4" ANCHOR BOLT S
MIN.
ON EA SIDE OF UPRIGHT a 2" MAX
4 MAX 16" O.C, BETWEEN
UNIT WIDTH
/ LENGTH
SILL TO CONCRETE SLAB CONNECTION DETAIL
NOT TO SCALE
!�kE'iHE R�sNCIdSi�iLfi V Up �H�
MTRACTCP OF RECOPY
SUN 4 SHADE SUNROOM PORCH ENCLOSURE
PER AAMA/NPEA/NSA 2100-02
PHIS STRUCTURE MEETS SUNROOM CATEGORY 'T" REQUIREMENTe
PRODUCT APPROVAL SUBI"iITTAL AFFIDAVIT
THE WRIGHT RESIDENCE
THE FOLLOWING PRODUCTS WILL BE
6852 BRONTE CIRCLE
INSTALLED IN THE STRUCTURE LOCATED AT:
PORT ST. LUCIE, FL 32961
PRODUCT
PROD, DESIGN
PRODUCT
PRESSURES
MANUF,
MODEL -
APPROVAL
FRENCH
DOOR
+/- 86 PSF
LAWSON
2200 LaPORTE IMPACT
NOA 14-0908.01
SLIDING
GLASS DOOR
+16 -95.0 PSF
LAWSON
'3200 IMPACT
NOA 14-0908.02
HRZ. WINDOW
+/- 80 PSF
LAWSON
HS 8100 IMPACT
NOA 11-0222.14
ROOFING
MATERIAL
+/ 8o PSF
ELITE
4" x 0.024"x 20 EPS
Aluminum Composite Panel
FL 1561.1
STRUCTLRAL
WALL / KICKS
+ 43 -10 PSF
ELITE
3" x 0.032"x 28 EPS IMPACT
Aluminum Composite Panel
FL 12225.1
MULLIONS
+/- 54 PSF
LAWSON
I x 3 IMPACT Alum.
NOA I1-0222.13
1 HAVE REVIEWED THE ABOVE lSo2-�5z8
SCANNED
ST. LUC ^nT �ti Ri TT n SiON
COMPONENTS AND CLADDING, I 1Fy, 'r
i(
i t)d COI:PI
AND HAVE APPROVED THEIR Ai ILtt LD By Stbr1,''�nUlllyl
USE iN THE STRUCTURE TO DATE
AND PERMIT MUST E KEPT ON JOB
PROVIDE ADEQUATE RESISTANC
L;krs
�9I1�SP15�TIA,VIitiL EASADE.
TO THE WIND LOADS AND FORCES
SPECIFIED BY THE CURRENT COP PLANS AND ALL PROPOE D WORKPROVISIONS.
AFIE SUBJECT TO ANY CORRECTIONS
AS SIGNED, SEALED 4 DATED HIRE BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
S9MPkY WITH AU APPUCABLA 00DL'1,
PERMIT - 18020528
REVISED POLY PANEL ROOF
TO EXISTING ROOF CONNECTION DETAIL
FILE COPYlo�/S
A
°°
O
M M
O
o�
W . 9 M
I�
C7
W"Z��
z�CIO)
�w�E~
`�OoF
ww0��0
fT�
rn
�-1-Lr-
LUo
U 61
z Urn
Q U �
J-1-� LU yj
z U
o�
V
N I—
0-
CA
�
M ,
1-
-
CP
ig
O
Z
z�
>
z
0-
d
W ,
_
W
`W
W
id
%3
a Copyright 2017
All rights reserved
REVISION DATE
1-3-IS
JOB - 11105
DATE . 11/28/11
SHEET
1 cif 1