Loading...
HomeMy WebLinkAboutPLAN APPROVAL7 y intertek , psi January 25, 2018 Mr. Thomas Campbell Florida Department of Business and Professional Regulation Codes & Standards Office 2601 Blair Stone Road Tallahassee, Florida 32399-0772 RE: Plan Approval Manufacturer: EZ Portable Buildings, Inc. (MFT11604) Plan Number: Barn-17 Intertek-PSI Tel +1407 304 5560 1748 33" Street Fax +1407 304 5561 Orlando, FL 32839 intertek.com/building U ECEIVED EB 21 2018 e County, Permitting Dear Mr. Campbell: Professional Service Industries Inc., an Intertek company ("Intertek-PSI"), part of Intertek' Building Science Solutions, in pursuant to the requirements of the Florida Department of Business and Professional Regulations, the above referenced docume nts have been reviewed for compliance with: i 2017 Florida Building Code, 61 Edition 2014 National Electrical Code (NFPA-70) These plans comply with Florida Product i Approval Rule 61G20-3.006 (FAC) A signed and sealed set of plans are maintained on file in the Third -Party Agency office of PSI. I All mandatory comments have been satisfied and plans are approved for construction by a modular building manufacturer that is currently approved by the Department of Business and Professional Regulations. If you have any questions or require my assistance in any way, please do not hesitate to contact me. Respectfully submitted, I p Y Professional Service Industries, Inc. if Victor C. Martin, PE #82379 Department Manager Modular Facilities Division CC: Rob Eaton — EZ Portable Buildings, Inc. - reaton@ezpb.com I'I Intertek is a brand name representing the Intertek Group plc legal entities, including but not limited to, Intertek Testing Services NA Inc., • Professional Service Industries, Inc. ("INTERTEK-PSI"), Architectural Testing Inc. (` INTERTEK- MT n In - www.intertek.com/building 2018-01-26 DESIGN CRITERIA PER FBC 61h EDITION (2017) AND ASCE 7-10 coed carso,lcn 0 n"ev,.lEwrrl.m� wrrs � ra.ImEoa.rrwr.w,. �� rm V.. psi PORTABLE BUILDINGS BARN TYPE ROOF STRUCTURAL NOTES &EBf.BAL: 1. FOUNDARON PLANS ARE NOT PART OF THIS PLAN SET AND ARE CO✓ERNEO BY LOCAL JURISD/CRON. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSER✓ATON CODE PER SECTION 1015.22. J. REFER TO T£-DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. 4. ALL STUDS, RAFTERS, TRUSSES. ETC. ARE 2 X 4 12 SPRUCE -PINE FIR OR SPF. 5. STRUCTURES OVER 400 SO. Fr.. WILL HAVE AN 60' MINIMUM DOOR. 6. GUTTERS TO BE INSTALLED ON-SfTE BY OTHERS THRU LOCAL CODES. 7. ALL WINDOWS AND DOORS TO MEET THE MINIMUM SPEC/RCATONS AS PER FLORIDA BUILDING CODE B. STORAGE SHEDS ARE NOT DESIGNED FOR HUMAN HABITATION SHEDS THAT HAVE FLOOR AREA OF 720 SQUARE FEET OR LESS ARE NOT REQUIRED TO COMPLY WITH THE MANDATORY WIND -BORN DEBRIS IMPACT STANDARD OF THE FBC. IYDPd A. FRAMING LUMBER SHALL BE AS FOLLOWS OR BETTER. 1. 2X RAFTERS/BEAMS/JOISTS, 42 SPF OR AS DETERMINED BY THE ENGINEER. 2. I -JOIST AND ENGINEERED BEAMS PROVIDED BY MANUFACTURER .T. PLATES. 12 SPF. 4. STUDS, 12 SPF TYPICAL UNLESS OTHERWISE NOTED 5. WOOD MOISTURE LESS THAN 19T B. ALL NAILS SHALL BE COMMON UNLESS OTHERWISE NOTED C. WHERE NOT OTHERWISE NOTED ALL NAILING OR SCREWING SHAG. BE AS INDICATED IN THE CURRENT FLORIDA BUILDING CODE, ASCE-7. ALL SHEATHING MUST BE NAILED OR SCREWED AND ADHESIVES SHALL NOT BE USED IN PLACE OF NAILING D. METAL CONNECTORS TO BE PROVIDED BY SIMPSON. ALTERNATE CONNECTORS WACUIVALENT OR HIGHER ALLOWABLE LOADS MAY BE USED IN LIEU OF SPECIFIED COMPONENTS. INSTALL AS PER MANUFACTURERS RECOMMENDATIONS. E. ALL EXTERIOR WAGS TO BE SHEATHED WITH MIN. J/16- EXTERIOR LP SMART SIDE STRUCTURAL SIDING. FASTEN WITH MIN. 6E RING NAILS 06' O.C. ALONG PANEL INSET EDGES, THEN 6- O.C. ON THE LAP JOWT EXTERIOR EDGES AS PER MANUFACTURERS INSTRUCTIONS. 12' O.C. INTERIOR SPACING FOR ALL EXTERIOR SHEAR WALL S/DfNC. F. ENGINEERED COMPONENTS (TRUSSES !-JOIST. E7C.) STALL BE INSTALLED AND FASTENED PER MANUFACTURERS SPECIRCATIONS AND DIRECTIONS. ti U C PSI APPROVAL 2018-01-26 P51 maamm. I : r�,',I,a hl � •s�„�P�M�a� I m rm wuss� Au suraer ri C , ,p'sa rurs • W oau ggg Q. �p� III L i L air SECTION DU-POST&RA% C •N SIOEWA EIEVATIONMHPORCH I ...n r•. •-p Q rY Ol qg �j call # 98 B g W-40L I � w w .. . ..... . . . . . MD WALL PLAN WEW SECTION WRH PORCH S.N4 ./.' • I POR�LN OEIU%OP'RON A. KE &tv, nmm*, PSI ---- NOTE.' WHEN CE]UNG IS �,mrru OSED FOR SfORACE nrr�ir]uu USE 2e6 CEILING sw JO1575 12r/ren vmcv.e.n 2X6P.r.A-,r 7 oAJ• rk �FRONTSA�STFFENER BOARD FLOORP MEW N' OO G a �v0 D' 6C Nraa:4 1 %lm 0 FRONT ELEVA0N YNG �/.• , MDT I I I I I I I PSI APPROVAL 2016-01-26 �aJlaeeL.em>g FCNtBN: r. rmwwmu ArArn' Aac ror a]ar ar rNa nAN sn AAD Aac cow.ran er iorx .n]asAcmN z co sra�vn�i woC�aat �Mr rec Drwcr J. axs�rADA�na+�' a� a�D+a m u¢�i ca�oc I. NL 51DOi R.Ii7E(6. rRBfYS CIL A4C ] X . /] smxr-wa rm m sv: c.f¢ BOaID No¢ S SMTICNRES OHA 1O0 58 lX WLL IaL£ AN BO' Nm.rUv DOOR e 4ifROS ro BE M7Al3ID CW-91E BY OIIIOS MRa IOfX CO06 1. ALL WMJOMS ANO M1PP5 ro 1SL7 M[ dOWUY ' SP[Dfl[Xre)M' AS P6it iSAad OLBv.0 [OOC 8 5T6WOC BHNS AIS M)r OrSXMD i0a MALIN DETAIL V wmunaa. — -r wW RaOR .V1G Qi l]O SBwac T¢r oa Aec wr araumm m I IOO�C � � f1WHY WM Mf' Wx6110M .v.D-BORN 8[8.P6 nw cr sMMuaa a na rOc �t : 1•!'�''f , ,, . , (• I I omA s• O r Ana m ."aia�m. � .uNrs surrmm e„�„ C — _ :w smt rurzs vm rum BVM Bme DETAIL -INSIDE SIDE WALL VIEW � SIDE`^WALL EI.EVATON •— rry ML SKID LAYOUT AND FLOOR FRAMING SCHEDULE WIDTH I50 PSF LWE.10 DEAD LOAD (25KID) I J015T SIZE 8 SPACING A U D 16. 10'-0' DRTO JO' 60' FLOORJOISTAND SKID LAYOUT SKID LAYOUT AND FLOOR FRAMING SCHEDULE WIDTH 50 PSF LIVE. 10 DEAD LOAD (C WD) JOIST SIZE 8 SPACING A 0 JJ' 60' 1�'-0' OTRO 45' 60' I6'-0• DITTD 57' 60" Ci z F a � G O a N W m i PSI APPROVAL 2018.01-26 ,eerx I Mevh41. PSI �. ort lru.xvn �.�ima4n n�•w.n I .uw I xvff i.»1� I I _ ..ran.. ..� ..era rsaurwew aas ma.�lr r�"`aa" . • •r �mrar •r•xr.ea.ssr.ya.•rs• STRAP & SIMPSON STRONG -DRIVE SD SCREW SCHEDULE PART/OESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTNER H1 435 6-SD9.1.5' 4-S09xl.5" H11Z 750 6-SD9x1.5" 6-SD10.1.5' H2A 495 5-SD9.1.5' S-SD90.5" 2-SD9x1.5" H2.5A 540 5-SO9.1.5" 5-SD9.1.5" HIS 410 5-SD9.1.5' 5-SD9x1.5" H2.5T 545 5-SD9.1.5' 5-SD9.1.5' H2A 495 7-SD9.1.5' 5-SO9.1.5' H3 320 4-SD9.1.5' 4-SD9.1.5" H4 280 4-SD9x1.5" 4-509.1.5" - RAFTER H5 415 4-SD9.1.5" 4-D9.1.5" 5D LTS-12 895 5-SD9.1.5' 6-S9.1.5' LTS-16 1075 6-SD9.1.5" I 6-SD9.1.5" LTS-18 1235 6-509.1.5" 6-509.1.5" LTS-20 1215 6-SD9x1.5' 6-SD9x1.V NTS-12 895 1 7-SD9xl.5' I 7-SD9xl.5" NTS-I6 1075 1 7-SD9x1.5' I 7-S090.5- - NTS-IB 1255 1 7-SD9.1.5' I 7-SD9xl.5' - NTS-20 1255 1 7-SD9.1.5' I 7-SO9.1.5" STRAP & FASTENER SCHEDULE (a) PART/DESC. UPLIFT WALL FASTENER A FRFTER PLATE FASTNER HI 435 6-SO9.1.5" 4-SD9.1.5" HIIZ 750 6-SD9xl.5" 6-SDIa.1.5" H2A 495 5-SO9.1.5" 5-SDW S1 2-SD9x1.5" H2.SA 540 5-SD9xl.5' S-SD9.1.5' H2.5 410 5-SD9.1.5' 5-SD9x1.5" H2.5T 545 5-SD9.1.5" 5-SD9.1.5' 112A 495 7-SD9.1.5" 5-SD9.1.5' H3 320 4-SD9.1.5' 4-SD90.5" H4 280 4-SD9.1.5" 4-S09.1.5" - RAFTER H5 415 4-S09.1.5' 4-SD9.1.5" - LTS-12 895 6-SD9x1.5" 6-SO9.1.5' - LTS-16 1075 6-SD9.1.5" 6-SO9.1 5' - LTS-18 1235 6-SD9x1.5" 6-SO9.1.5' - LTS-20 1215 6-SD9.1.5" 6-S09xl.5' - NTS-12 895 7-S09.1.5" 7-SD9.1.5' - NTS-16 1075 7-SD90.5" 7-09x1.5" - NTS-18 1255 7-SD9xl.5' 7-SD9xl Y - UTS-20 1255 7-SD9x1.5' 7-SO9.1.5" PART/DESC. UPLJFT COL FASTENER RAFTER FASTENER A21 245 1 2-IOd.1.5" 2-10d.1.5" PORCH A23 585 4-I0d.1.5' 4-10d.1.5' A33 750 4-10d 4-I0d PART/DESC. UPLIFT COL FASTENER RAFTER FASTENER WALL 70 FLOOR LSTA-18 Ilia 7-10d 7-10d PART/DESC. UPLIFT STUD FASTENER HEADER FASTENER TP-35 ilia 5-21'.0.131" 5-3".0.131" HEADER (d) HP40, 411. 80, BI 4725 5-3'x0.131' 5-310.13I' a.M xtrape mn Eo auEstimtad v911 an o9uvabnlbem nmdLg Bann em.gdo. 6. ReM Ueam Nl0 xra0m mel ava+y caukctinlfn 24"ocB �lEa ever d6c mr t(C oc, ddb mryimdonamsmamam mmn .ONy reed 1. on aNmm� & A WD1 s�eatNrg •aM. 1 Hamm mm6 __ .✓�cxn>a S-3-0 32 feet 10 40 feet 12 If you need any additional clarification, please do not hesitate to call. Sincerely, Austin R. Ace -uat R. 4e, ;a, S.. 9na. 5908 Orchard Pond Drive Fleming Island, FL 32003 Florida License No. 35454 904-579-4508,1office, 904-716-3661, cell i 18 January 2018 EZ Portable Buildings, Inc. 1745 Carneal Road I West Paducah, KY 42086 Reference: Anchor Requirements i Gable Buildings R-0 Barn Buildings R-0 140 MPH Ultimate: Wind Speed Gentlemen: I The following anchor requirements are for storage buildings manufactured in accordance with on the buildings listen above;, complying with Florida Product Approval Rule 61 G20-3.006 (FAC). All anchors shall have a minimum design load of 3150 pounds, and be on the list of approved installation products .forithe Florida Department of Highway Safety and Motor Vehicles per Rule 15C4.0105, and must be the proper length for conditions at the installation site. Anchors- required per shed length (half number shown shall be installed on each side of the shed). Chart is valid for building widths up to 16 feet: 10 feet 4 12 feet 4 16 feet 6 20 feet 6 24 feet 8 28 feet 8 30 feet 10