HomeMy WebLinkAboutBOAT LIFTENGINEERING REVIEW.
BOAT LIFT TOP CARRIER BEAMS AND
MOUNTING BRACKETS COMPLY WITH
WIND LOAD REQUIREMENTS OF THE
6TH EDITION (2017) FLORIDA BUILDING
CODE, PER ASCE 7, AND PER DESIGN LOAD
REQUIREMENTS OF THE 2015
EDITION ALUMINUM ASSOCIATION'S
ALUMINUM DESIGN MANUAL.
BEAMS AND MOUNTING BRACKETS
INSTALLED PER HI-77DE INS7RUC77ONS, WILL
EXCEED ULTIMATE DESIGN WIND SPEED OF
180 MPH (EXPOSURE CATEGORY C OR D)
BOATS ARE TO BE REMOVED FROM BOAT
LIFTS PRIOR TO A MAJOR WIND EVENT.
PILINGS:
PILING PENETRATION TO BE 10'
INTO THE SAND BOTTOM OR 5'
INTO ROCK STRATA,
SUB -SURFACE CONDITIONS CAN
VARY GREATLY, THE CONTRACTOR
SHALL VERIFY ALL PILE
CAPACITIES TO COMPLY WITH
2017 FBC. ALL PILINGS TO BE
1 0" MINIMUM
DIAMETER 2.5 C.C.A
PRESSURE TREATED WOOD,
PRE —STRESSED CONCRETE OR
COMPARABLE EQUIVALENT.
ELECTRICAL REVIEW.
1 HP ELECTRIC MOTOR
12.8 AMPS ® 115V EACH
6.4 AMPS ® 230V EACH
QUANTITY 2
TOTAL WATTS: 2944
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY REIN INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPIJCASI,E CODES
Sfi. LUC?E' coupn".7 pT�T PTri� - - +' IO NOTE TO EXAMINER:
I?WVLWE.0 FOR CObIPL r THIS CERTIFIED ENGINEERED
DRAWING HAS BEEN PREPARED
REVIEWED BY
DATE 3� SPECIFICALLY FOR USE ONLY BY.•
PLANS AND PERMIT DIUST BE KEPT ON JOB
rOR NO INSPECTION WILL BE MADE.
CONCEALED FAS T Ea OR AL I ACh WEil ,
ARE THE RESPONSIBILITY OF THE
CAliTRACTCR OF RECORD
`,-
°°°opOp Coot CC 00000000
00
o°°° VL M e oO°o
o°° p� \ C E p 8� A o
o � F °o
Q' NO.43855 e
e o
+i� J N 18
4' e
0o C STATE OF oo°
o lc 4 O R 1 D t� Z o000
0000OB� ° ONno10000pp0�p°°o°
ROGER BABER
P.E. NO. 43855
MCR PROFESSIONAL ENGINEERING
C.A. NO. 26967
1014 NW PINELAKE DR.
S7UART, FL 34994
----PILING MOUNTING TABS
MINIMUM---
BOL TS FOR WOOD PILING OR
SS CONCRETE ANCHORS FOR
CONCRETE PILINGS PER PILING
REQUIRED. MINIMUM (2) 3/8"
DIA. SS CARRIAGE BOLT FOR
ATTACHING MOUNTING TAB TO
LIFT REQUIRED PER PILING.
MOUNTING TAB CONSTRUCTED
FROM 1/4" X 2" ALUMINUM
6061-T6 FLAT BAR.
he wou flim- r
16,000 LB. CODA GEAR BOAMIFTS AND MAR/NE PRODUCTS
BOAT LIFT (2017 FBC) ULID�� 4050 SELV/TZ ROAD
FORT PIERCE, FL 34981
R. HYDE SCALE: NTS DATE: 112118 REV 1 1-800-544-0735 www.hi-tide.com