HomeMy WebLinkAboutEVALUATION REPORT• -
ST L ��ur� ��r
�A1Z FASTENERS OR ATTACHMENTS
R 'irLEEW;EU rOitCO- ` � SIrJN
wi C�
®�'
'E THE RESPONSI61lNY OF THE
REl.VMWED B
DATE �
St Lucia Couniv
CO�i1RACTOR OF RECORD
#8
PLAINS AND PERMIT MUST BE KEPT ON JOB RECEIVED
®�-N® ` SP CT1fAtY Wjpl j>y BE MADE,
EXTERIOR RESEARCH & DESIGN, I.I.C.
FEB: 21 2010
Certificate of Authorization ##9503
TRINITY I ERD
Permitting Department
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
St. Lucie County
(203)262-9245
EVALUATION REPORT
Tarco Roofing
Evaluation Report 4930.02.14-113
One Information Way, Suite 225�w
®��
FL16884-R3
Little Rock, AR 72202
Date of Issuance: 02/27/2014
(254) 913-7750
Revision 3:10/03/2017
SCOPE: I
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida IlBuilding Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: LeakBarrier EasyLay UDL Synthetic Roof Underlayments
I
LABELING: Labeling shall be in accordance wi Ih the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entirelEvaluation Report shall be provided to the user by the manufacturer or
its distributors and, shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3. THESE PLANS AND AU PROPOSED WORK
Prepared by: ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
BE NEC ESSARY IN ORDER TO
I
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE19831
COMPLY WITH AU, APPUGABLB 000U, °"
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 10/03/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrihityI ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
FILE COPY
'\JTPJN1N ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment!
Compliance Statement: LeakBarrier EasyLay UDL Synthetic Roof Underlayments, as produced by Tarco Roofing,
have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through
testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.1.1, T1507.1.1 Unrolling, Breaking Strength, ASTM D226 2009
Pliability
1507.1.1 Tear Strength j ASTM D1970 2015
1507.1.1 Tear Strength i ASTM D4533 2015
TAS 110 Accelerated Weathering TAS 110 2000
3. REFERENCES:
Entity Examination i Reference Date
ERD (TST6049) Physical Properties SC4950.02.14 02/27/2014
ERD (TST6049) FBC 1507.1.1 (Exception) TAR-SC16115.17 10/02/2017
UL, LLC (QUA9625) Quality Controli Service Confirm, 10227624 Exp. 11/22/2019
4. PRODUCT DESCRIPTION:
4.1 LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top surface;
meets FBC 1507.1.1 (Exception).
4,2 LeakBarrier EasyLay UDL Basici consists of a woven -polymeric scrim with a textured fabric on the top
surface; meets FBC 1507.1.1(Exception).
4.3 LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top
surface and a rubberized polymeric coating on the back surface meets FBC 1507.1.1 (Exception).
S. LIMITATIONS:
5.1
5.2
5.3
5.4
5.5
This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance' unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
LeakBarrier EasyLay UDL Synthetic Roof Underlayments may be used with any prepared roof cover where
the product is specifically referenced within FBC approval documents. If not listed, a request may be made
to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for
the prepared roof covering.
Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes &
Shingles
Slate
EasyLay UDL 15
Yes
No
No
Yes
Yes
Yes
EasyLa D. Basic
Yes
No
No
Yes
Yes
Yes
EasyLay UDL 50
Yes
No
No
Yes
Yes
Yes
Exterior Research and Design, I.I.C. Evaluation Report 4930.02.14-R3
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16884-R3
LeakBarrier EasyLay, UDL Synthetic Roof Underlayments; (254) 913-7750 Revision 3:10/03/2017
'Page 2 of 3
TRINITY � ERD
5.6 Exposure Limitations:
LeakBarrier EasyLay UDL 15 shall not be left exposed for longer than 30-days after installation.
LeakBarrier EasyLay UDL Basic and, LeakBarrier EasyLay UDL 50 shall not be left exposed for longer than
180-days after installation.
6. INSTALLATION:
6.1 LeakBarrier® EasyLay UDL Synthetic Roof Underlayments shall be installed in accordance with Tarco
Roofing published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
6.1 LeakBarrier EasyLay UDL 15, UDL Basic or UDL 50:
6.1.1 Shall be installed in compliance with ithe requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -width for
- double -layer applications.
6.1. For slopes 4:12 (18.4°) or greater: LeakBarrier EasyLay UDL Synthetic Roof Underlayments shall be laid
horizontally, parallel to the eave with the printed side up, flat and unwrinked and have minimum 4-inch side
(horizontal) laps and minimum 8-inch end (vertical) laps. Side (horizontal) laps shall run with the flow of
water in a shingling manner. End (vertical) laps shall be offset from course to course not less than 3 feet.
6.1.3 For slopes 2:12 (9.4°) to < 4:12 (18.4°): LeakBarrier EasyLay UDL Synthetic Roof Underlayments shall be
applied in a double coverage method, flat and unwrinkled. Begin by applying a 24-inch wide starter -strip
along the eaves. Then place a full -width sheet over the starter, with the lower edge flush to the starter's
lower edge. Apply succeeding 484 Inch wide courses up the roof slope, overlapping each previous course a
minimum of 20-inches in a "shingle fashion" with minimum 12-inch end (vertical) laps. End (vertical) laps
shall be offset from course to course not less than 3 feet.
6.1.4 Where laps or joints require sealant or adhesive use plastic cement recommended by Tarco Roofing. Tarco
Roofing recommends sealing all laps and joints where the underlayment will be exposed to wind -driven rain.
6.1.5 Attachment: Use corrosion -resistant or stainless steel roofing nails with 3/8-inch diameter heads or low -
profile plastic cap -nails with 1-inch diameter heads spaced 9-inch o.c. at all laps and 12-inch o.c. at two (2)
staggered rows in the field of the sheet. If wind or rain is expected prior to finished roofing application, use
1-inch diameter plastic cap nails
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant
Specification
Product(s)
Gujarat, India
FBC 1507.1.1 (Exception)
LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic, LeakBarrier
EasyLay UDL 50
9. QUALITYASSURANCE ENTITY:
UL, LLC. — QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate ofAuthorization #9503 If" EDITION (2017) FBC NON-HVHZ EVALUATION
LeakBarrier EasyLay UDL Synthetic Roof Underlayments; (254) 913-7750
Evaluation Report 4930.02.14-R3
FL16884-R3
Revision 3.10/03/2017
Page 3 of 3