I APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
5335 MONTEGO CIR FT PIERCE, FL 34949
DETAILED DESCRIPTION OF PROJECT
REVISIONS: - I
I
DUE TO MATERIAL SHORTAGE THE UNDERLAYMENT IS CHANGING FROM TITANIUM UDL 25 TO POLYGLASS TU MAX FL#5259
CONTRACTOR INFORMAT
STATE of FL REG./CERT. #: - lCCCl
BUSINESS NAME: ALL AREA ROOFI
QUALIFIERS NAME: ANDREW, GRIFI
ADDRESS: 3921 S US HWY 1
CITY: FT PIERCE i
PHONE (DAYTIME): 772-464-6800
I
OWNER/BUILDER INFORMATION:
I
330649 ST. LUCIE CO CERT. #: 30522
& CONSTRUCTION
STATE: FL
ZIP: 34982
FAX: 772-464-6600
NAME: MARY JACOBS
ADDRESS: 5335 MONTEGO CIR
CITY: FT PIERCE STATE: FL ZIP: 34949
PHONE (DAYTIME: 609-709-7186 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
RevisedISM
SLCCC 9123109 m"ILE
I. l X' 6vFT
}na �,1 � � fr•.
\
*Florida Building C1ode Online ICE EIVED Page 1 of 2
r
MAR 119 2018
d : ; ST ,Lucie Cbunty, Peritting
BCIS Home Log In User Registration •� Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Slte Map i Links (•Search .�
Florida
oum)
Product Approvallf� ji USER: Public User p
Product Approval Menu > Product or Apnlicatlon Search > Application List > Application Detail
° FL # FL5259-R27 �j S
Application Type Revision pd, r'
Code Version 2017 � Af'�
Application Status Approved
1tk
Comments
Archived
Product Manufacturer POLYGLASS USA ST. LUCTE COLfi'TV BUILD ION
Address/Phone/Email lilt W. Newport Center Driv$_EVIEWED FOR COMMLL '
Deerfield Beach, FL 33442
(954) 233-1378 Ext 242 REVIEWED Y
alender@polyglass.com DATE
PLANS AND PERMIT MUST BE KEPT ON JOB
Authorized Signature Ariel Lender OR NO INSPECTION WILL BE MADE.
alender@polyglass.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report i
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Maury Alpert
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAI pert@ p o lyg lass. com
Ariel Lender
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1230
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAYBE NECESSARY IN ORDER TO
COMPLY WIN ALL ARUA69 99DE5,
ALender@polyglass.com • ;F.ALED FASTENERS OR ATTACHMENTS
Roofing ARE THE RESPONSIBILITY OF THE
Underlayments
CONTUTTOR OF RECORD
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
=1 Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/05/2018
John W. Knezevich, PE
:I Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R27 COI 2017 01 COI Nieminen ndf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
TAS 103 1995
TAS 110 1: py
"' 1 L , " CO
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk2vSD/o... 2/6/2018
,I
dFlorida Building Code Online
i
Equivalence of Product Standards
Certified By
Sections from the Code
I
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
I �
UL 1897
Method 1 Option D
09/14/2017
09/15/2017
09/18/2017
12/12/2017
01/24/2018
Page 2 of 2
2012
FL #
Model, Number or
Description
Name
5259.1
Polyglass Roof
Roofing underlayments
Underlayments I
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5.259 R27 )I 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R27.DdF
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure In this
Evaluation Reports
application relates to one particular
FL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R27.)df
underlayment system (over concrete
deck) for use under foam -an tile systems
(where the underlayment forms part of
Created by Independent Third Party: Yes
the load -path). Refer to ER Section 5.6.4
for other systems, other deck types and
associated maximum design pressures.
2.) Refer to ER Section 5 for other limits
of use. i
Oack Next
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mall to this entity. Instead,,. contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to
Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
W ef:tec B
Credit Card
Safe
https://floridabuilding.org/pr/pr_app dtl.aspx?param--wGEVXQwtDqvbSqAaZp3Crk2vS%... 2/6/2018
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
QOTRINITYIERD 353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R23
150 Lyon Drive FL5259-R27
Fernley, NV 98408 Date of Issuance: 02/24/2009
(570) 384-1230 Revision 23: 09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report- is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity l ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation'Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire lEvaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
I
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
��TRINITYJERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Sth Edition (2024) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1523.6.5.2.1
Physical Properties
TAS 103
1995
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
KaMy
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-111
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
Exterior Research and Design, LLC.
Evaluation Report P12060.02.09-R23
Certlykate of Authorization #9503
6T" EDITION (2017) FBC NON-HVHZ
EVALUATION
FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230
Revision 23: 09/14/2017
Page 2 of 14
Entity
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ICC-ES (EVL 2396)
Miami -Dade (CER 1592)
Polyglass USA
Polyglass USA
Polyglass USA
UL, LLC. (QUA9625)
4. PRODUCT DESCRIPTION:
Examination
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
IBC Compliance
HVHZ Compliance
Manufacturing Affidavit
P/L Affidavit
Materials Affidavit
Quality Control
Reference
P40390.08.12-1
P40390.08.12-2
C41420.09.12-3
P39680.03.13
P45370.04.13
P1738.02.07-R2
11757.04.01-1-R1
P41630.08.13
P11751.05.03-R1
P11781.11.03-R1
P45270.05.14
6020.07.144
6020.09.14-2
6020.09.14-3
6020.09.14-4
6020.09.14-5
6020.09.14-6
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC7550.03.15
P40390.04.15
PLYG-SC8080.05.15-1
PLYG-SC8905.05.16-1
PLYG-SC8080.07.16
PLYG-SC12025.10.16
PLYG-SC13040.12.16
PLYG-SC11900.03.17
PLYG-SC1211508.17
ESR-1697
NOA 14-0717.08
Products Current
Mule -Hide Cross Ltg
Polystick SA Compound
Service Confirmation
4.1 Mechanically Fastened Underiayinents:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
QPTRINITYIERD
Date
08/06/2012
08/07/2012
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
08/06/2013
11/26/2013
11/26/2013
05/12/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
10/03/2014
10/07/2014
10/17/2014
03/24/2015
04/03/2015
05/20/2015
05/17/2016
07/16/2016
10/12/2016
12/27/2016
03/10/2017
08/08/2017
11/01/2014
01/22/2015
02/18/2009
03/01/2009
08/18/2011
Exp. 10/05/2018
4.2 Self -Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate ofAuthorizotion H9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 3 of 14
TRINITY � ERD
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface;; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60,mil thick rubberized asphalt waterproofing membrane with a 190 g/mz polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual ProTM is a nominal, 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile ProTm is a nominal ' 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012:
;(04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6,G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the `Two iPly System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificote ofAuthorizotion #9503 6T"IEDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 4 of 14
��TRINITYJERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Elastobase
Yes
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet In 2-ply system)
No
No
No
Polyglass APP Base
No
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet In 2-ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
PolystickTU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
ElastoflexS6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE
1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch 'n Seal StormBond Roof
Tile Adhesive
FL14506
Polystick TU Plus, Polystick TU Max
Dow TileBond"
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass Polyl-ok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6"'IEDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 5 of 14
��TRINITY ERD
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet,wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Band -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type ll, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G oriElastoflex 56 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK, Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver.:
Polystick (all variations), Polyflex !SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex 56 G or, Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 6 of 14
r-\/�
TRINITY ERA
5.6.4 Wind Resistance for Underlavmerit Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of a'll underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap!Sheet (FR), self -adhered.
#2 Maximum Design Pressure = -97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100orASTMD41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
lY." ring shank nails th 'rough 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IN" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -135 usf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 orMTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#5 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure = -622.5 osf:
Deck: Structural concrete to'meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41 '
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure = -30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#8 Maximum Design Pressure =-37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 364-1230 Revision 23: 09/14/2017
Page 7 of 14
��TRINITYIERD
#9 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#10 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch c.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure = -45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure = -52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#15 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Efastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure -60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Efastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 8 of 14
��TRINITYJERD
#17 Maximum Design Pressure = -60 ost
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75gsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, CMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-ihch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -90 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface)
Fasteners:
Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment:
Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#23 Maximum Design Pressure = -90 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners:
Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, CMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing:
9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
CertifcateafAuthorizotion #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 9 of 14
��TRINI*ERD
#24 Maximum Design Pressure = -97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch D.C. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure = -105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#26 Maximum Design Pressure = -1201 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or CMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
1
#27 Maximum Design Pressure = -120 DO:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded tbp surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 446ch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered 'Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum.design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design'professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,'tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 10 of 14
TRINITY ERD
5.9 Tile Slippage Limitations RAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS
Flat or Lugged
Prohibited without battens
N/A
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
641le stack (4 over 2)
4:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified'requirements for ASTM D226, Type II underlayment in FBC Table
2507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap! Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
CertlficateojAuthorizatlan #9503 6T" EDITION (2027) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 11 of 14
v I RINITY�ERD
6.4 Polystick MTS, IR-Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex;SAP'FR, Mule -Hide
SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR):
b.4..L anaii De Installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum : 28 lb. hand
roller to ensure full contact and adhesion. I
For Dual Pro and Tile Pro, align the edge ofthe top sheet to the end of the glue pattern =`-• " -'
(the sheet will overlap the fabric). `
View of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus So Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed. application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes, is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to: a large roller or broom.
6.4.3 Tile Applications (not allowed for Polystick Dual Pro 1R-Xe or Polystick MU-X)•
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.4.4 Two (2) Ply Underlavment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 12 of 14
\l TRINITY ERD
6.5 Elastoflex G TU, Elastoflex S6 G or,Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use'in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an,alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48)i hours.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
Certljlcate oJAuthorirotion #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 13 of 14
TRINITY ERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 611520-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
Plant
Specification
Product Us
Fernley, NV, Hazleton, PA & Winter Haven, FL !
ASTM D1970
Polystick MU-X
Hazleton, PA
M-D 13-0004
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASTM D1970 & TAS 103
Polystick TU Plus
ASTM D1970 & TAS 103
Polystick TU Max
Tuscaloosa, AL
ASTM D4601, Type II
Polyglass G2 Base
Winter Haven, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
TAS 103
Polystick MTS
ASTM D1970 & TAS 103
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P FR
ASTM D1970
Polystick Dual Pro
ASTM D1970 & TAS 103
Polystick Tile Pro
ASTM D6164
Elastoflex S6, Elastoflex 56 G FR
ASTM D6222
Polyflex G, Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate ofAuthorizotlon #9503 6?" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 14 of 14