Loading...
HomeMy WebLinkAboutEVALUATION REPORTEVALUATION, REPORT OF ST. LITC7 'M!7`7n` 7 ­ -1. q44*1,98 MANUFA4CT.UkING-CORPORATION ' !! R91w_Wi:i41v_0Ac0,, -42.6 GA. 5V-�C RIMI P__ PANEL'I If RECEIVED AW11WED BY ]DATE ­3/�, A'L"S AM PERMIT MUST BE KEPT OX J013 FEB 16 2018 m NO ANSRtmow WML By, m4ma - - , _.. - - 'iG- 9 6TH EDITION (201�7) FLOREDA, BUILfDIX G bt 6THIEDITION (2017).. L_ST, Lucie county, Permitting FL OM, A PRO FIVI 645.3-W ROOFING RECEIVED: THESE PLANS AND ALL PROPOSED WORK 1VMITALRQOFING, ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLY W17H AA APMAIRS COW, CONCEALED FASTENERS OR ATTACHOM lull I if 911; 40 I'l, E-Roc FEB 2 12018 ST. Lucie County, Permitting I I , Prepared For,: 'Metal Sales Mmitifietufffig Corporation 545 'Sbitth 9rd Street;. Suite 100. Lomkvffle, KY 40201 Telephone: ,(592) 85 . $4.300 Fax: �(502)85$4200 ,.Prepared By ; ' Bala SoekAlihgamPh.D., P.E. Florida RrOfis I §ional Engineer #6224.0 1216N1,ansing Ave., Suite C Tulsa; OK 7410.6 Telephone: (918) 401"5992 FAX: (866) 366-1543 This report consists of Evaluation Report , 3 Pages includmig,cover) Installation Details (I Page) %% ,BOCK A Report No. C11.82-3 Date: 9.9.17 N 6 62240 :xz 'STATE OF A, 4 NZeti OR .0o 0 F FL 146A,5.3-R3 C2182-3 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation, ; . , „ ; ; ; , ,... x . j , ; ... .••• . > :: , • , . : i. I.t .If ,,t y y" r I•.y Product Name: 5V-Crinl p - Panel Description: 24" widel coverage with (5) 1/2" high'' bs ` I 1 Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/3I2" plywood or min. W thick wood "Ifia,(i in)AS`GofY0.42 `P for new and existing constructions. Designedl,liyaolhefs'and�l"ntstall'ed as per FBC 2017. Deck Attachment: 8d x 2.5 long ring shank nails or #8 x 2"' long;wood,scr6w' @•;6 •�o`.e: (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017, Section, 1.507.4 5 1-- Required fQr new construction and optional for rer'oofng-6oristructi0n.' Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or I eater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.6 psf @ fl stener spacing of 36" o.c. (Factor of Safety = 2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @, fastener spacing of 8" o.c. Fastener Pattern: Type: #9-16 or #10!14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembl� tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads ds shall be determined for each project in accordance g p J with FBC 2017I Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity FL 14645.3-R3 1' C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting, Date 9/1/09 EXISTING SHINGLES (OPTIONAL) c r -Au NEW UNDERLAYMENT FACTFNFP AT PAAIFI FI AT .� TRUSS AT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X-SECTION NEW UNDERLAYMENT WITH SELF SEALING WASHER AT (REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. NEW CONSTRUCTION) EXISTING SHINGLES _ 5V-CRIMP (OPTIONAL) MIN 26 GA. EXISTING UNDERLAYMENT J (OPTIONAL) PLYWOOD DETAIL 1 19/32" THICK (MIN.) #9-16 OR #10-14 WOODSCREWS NEW UNDERLAYMENT WITH SELF SEALING WASHER AT (REQUIRED -ONLY FOR MAXIMUM SPACING OF 36" O.C. NEW CONSTRUCTION) EXISTING SHINGLES 5V-CRIMP (OPTIONAL) MIN 26 GA. EXISTING UNDERLAYMENT J G (OPTIONAL) PLYWOOD DETAIL 2 F 19/32" THICK (MIN.) 5V-CRIMP ALLOWABLE UPLIFT PRESSURE FASfIENER SPACING (IN) PRESSURE (PSF) 36 41.6 16 74.8 .8 196.75 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. t� d 00 Ci N 0 WN z 1' 0 7 Npp U � � u- ulY I o � X_,ro MJ I =N 0 J �U� 00 G¢ ul Li 8 J '^ W 0 i a o a a � a N Uo cn - NJ W II z a0 Y18L- SHEET I OF