Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL
4 Automatic Transfer Switches WA��EDGENERAC' SqLrccieCesa�ty Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C DDS LISTED •BWII In IM WA J gd..U, e and brelgn pWs `CUL only applies to non -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution TM or Nexus TM Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RTSW) Generac Automatic Transfer Switches are housed in, an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non -service rated (RTSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. ZAT 'ISO - w�sooti: ,20D8 100-400 Amps, Single Phase Functions All timing and sensing functions originate in the generator controller GENERAC5 Automatic Smart Transfer Switches Utilityvoltage drop-out...................................................................................................................................................,....................................................I.............<60% Timer to generator start ............................ ...:................................................... ...............1;0 second factory set, adjustable between 2-1500 seconds by a qualified dealer" Engine warm up delay ........................................... ......................................................... ..:............................................................................. ......I ...................... 5 seconds Standbyvoltage sensor..................................................................................................................................................................................................60% for 5 seconds Utilityvoltage pickup...........................................................................................................................................................................................................I.............>80% Re -transfer time delay...............................................................................................................................................................................................................15 seconds Enginecool -down timer ............................................. ...................................................... ....................................... :.................................................................60 seconds Exerciser..............................................................................................................................................................................................................12 minutes every 7 days The transfer switch can be operated manually without power applied. `When used in conjunction with units utilizing Evolution- controls Specifications Model RTSC10OA3 RTSW100A3 RTSW150A3 RTSC200A3 RTSW20OA3 RTSW300A3 RTSC40OA3 RTSW400A3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240,1e 120/240,1s 120/240, to 120/240, to 120/240, ie 120/240,1a 120/240,1H 120/240,1ta Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMANL 313 kMA7UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R UL Rating UL/CUL UL UL UL/CUL UL UL UL/CUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCM Dimensions Model RTSC100A3 RTSW100A3 RTSW150A3 RfS020OA3 RTSW20OA3 RTSW300A3 RrS6400A3 RTSW40OA3 Height H1 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 (in./mm) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 4811219.2 Width W1 12.5/317.5 12.5/317.5 10.5/256.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 (in./rnm) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (in./mm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/160.1 10.061255.5 10.06/255.5 10.06/255.5 Weight (lbs./kilos) 20/9.07 22.5110.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 GENERAC° f,, DEPTN�+ DEPTH C Generac Power Systems, Inc. • S45'W29290 HIM: 59, Waukesha, WI 53189 • generac.com ©2015 Genemc Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. BuAelin OL3205•B Printed in U.S.A. 0728/15