Loading...
HomeMy WebLinkAboutELECTRICAL RISER(2) 2 1/2" CONDUIT W/ (3) 350 MCM THHN CU IN EACH MAIN RES. MAIN RES. GARAGE METER EXISTING EXIST EXIST EXIST a 400A "MDP" -I 'I ATS 120/240V 1201240V 120/240V 1201240V (2) 212" CONDUIT WITH 1 — 1'', 1'. _ 1:; W/ (3) 350 MCM THHN CU DISC. 400A 200A 200A 11 IN EACH (VERIFY col FPL) -7 _T -7 TO FPL TRANSFORMER At Cu TIEDTO EXISTING (1) 1-1/4" CONDUIT / GROUNDING ELECTRODE a W/ (3) 93 THHN CU & 1 CONDUCTOR & GRND ROD (1) #6 CU GRND 1)2"CONDUIT #8CuTIED TO12"L. X20' W/ (3) 3M THHN CU Cu GROUND ROD & & (1) #6 CU GRND BLDG STRUCTURE TO STANDBY GENERATOR 01 (1) 3" CONDUIT INSTALL & CONNECT (1) 10' WU(4) 2ro THHN CU, (2)1/0THHN COPPER GROUNDING ROD &(1)#ZCUGRND W/CONTROL TO GENERATOR CHASIS WIRING GROUNDING LUG ELECTRICAL RISER NTS r,-\ Generator w/Automatic Transfer Switch 1 /4'r = V-0" Standby Generators INCLUDES: • Two Line LCD Tri-Lingual Digital Nexus'" Controller • Isochronous Electronic Governor • Sound Attenuated Enclosure Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • --t I % Voltage Regulation • Natural Gas or LP Operation • 2 Year Limited Warranty GENERAC Standby Generators Liquid -Cooled Gas Engine Standby Power Rating 770771 Model OT070 (Aluminum -Bisque) - 70 kW 60 Hz o -e 80 (Aluminum - Bisque) - 80 kW 60 Hz Model OT100 (Aluminum - Bisque) - 100 kW 60 Hz Model OT130 (Aluminum - Bisque) - 130 kW 60 Hz Model QT150 (Aluminum - Bisque) - 150 kW 60 Hz • UL 2200 Listed cWus V& Q(11R-ffff LISTED ..," Meets EPA Emission Regulations 70, 100, 130 & 150 kW meet CA/MA ern isslons requirement with optional catalyst 80 kW not for sale in CAIMA FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING ant lay components at 0 SOUD-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. GENERAO'S success in "IMPROVING POWER BY DESIGN." But it This state-ot-the-art paver maximi2ing regulation system is steward on doesn't stop there. Total commitment to component testing, reliability NI Generac models. It paivides optimized FAST RESPONSE to changing testing, environmental testing, destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA, EGSA, and other standards, allows you to electronically torque -matching the surge lean to the engine. Digital choose GENERAL POWER SYSTEMS with the confidence that these voltage regulation at -±1%. systems will provide superior performance. 0 SINGLE SOURCE SERVICE RESPONSE from Gammas extensive der network provides parts and service know-how for the entire unit, from the O TEST CRITERIA; engine to the smallest electronic component. PROTOTYPE TESTED NEMA MG1.22 EVALUATION 0 GENERAC TRANSFER SWITCHES. Long life and reliability are SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY synonymous with GENERAC POWER SYSTEMS. One reason for this confidence Is that the GENERAL product line includes its own transfer systems and controls to r tow system compatibility. j�jgiTI$O MIN. 6" SLAB FROM 5000# CONCRETE SLAB MUST BE LEVEL SLAB MUST BE MIN, 4" ABOVE GRADE OUTLINE OF 70KW GENERATOR THIS END AWAY FROM EXISTING HOUSE EXHAUST OF GENERATOR rra1onSlab ------------------------------- 2'- 8 1A" �Idie LOW VOLTAGE AREA ONLY I I 1131� ------ rn_____ L--------+ J — — — — — — o i — — — — — — _ ro — — — �� \_u �i-:_ •1/: i' C _ �• ►l_\ ► Ell '_r\ -:' :l�Gv. ��. .. ► :_ GENERAC 100.400 Amps, Single Phase Automatic; Smart Transfer Switches Functions Ali timing and sansing functions originate in the generator controller utility voltage drop -out... ..... ..... .............. ....... ....... .. „ ._...,. ......,,,. ....... <60% Timer to generator start . .......... . I. ....... ...... .... ....,. 10 second factory set, adjustable between 2-1500 seconds by a clu allied deal Engine warm up delay., . ,,.�..... ... ..... ... .. .. ,,....., . ..�.,.... ..., ,......,.. ,. .. ...,., ...,, ..,..,... ... , _..1,..,...5 93cands standby voltage sensor ...... ......... . ...... I. .... .. ... .. . ........ .. .... .. .. ..,., ...... ... ,...60% Itor 5 seconds tlanyvoltage pickup .... ........... ...... . ... ... . ... .. :. ... ... ... ........ . ......... .,,>80% R i-transfer time delay 15 seccnrs _ — — — — — — — Enginercool-down timer .. .. .. 60 seconds . , Fxercissr ...... ... .. .. .. —12 minutes every 7 days GENERATOR MODEL The tralaiwswnellcan beoperated manually without power zppiled — — — — 'When used in conjunction with units utillzing Evolution"' controls Specifications Modal RTSCIO(W Rl'SWIOOA3 RTSW150A3 RTSC20CA3 RTSW2oom Rr5W300A3 RrSC4WM RTSWt40G43 Amps 100 100 150 200 200 300 400 400 voltage 1201240,10 120/240, ie 120/240,1e 1201240, to 120/240, to 120/240, to 120/240,1a 1201240, to Load Transition Type (AuaAl)atit} Open Tranaltion Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Had open Transiticm ;Service Rated Open Tiansifion Open Tra croon Service Rated Enclosure Type NrMAI 3R NEMA/UL A NEMWUL 3R NEMA/UL 311 NEMA(UI. 3R NEMNUL 311 NEMA/UL 3R NEMANL 3R UL Rating UTA;UL I UL j UL i uucUl j UL j Ut, I U1GUL uL itertand;Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Rem! 1/a #14 250MCM -#6 1MCM -#4or1/0-250MCt4 Dimensions mom RTW.00A3 KoNlo0A3 RTSWI 50AS I RTSC200A3 RT5W20CA3 RTSW30M RTSC400M RTSW400A3 HeitJ11 H1 t72 437.9 4( 172 437 47 .9 ,7 79.4 26 5�6 17.. 4 7.9 2N 3 6,7 679.4 2 5/ 4 . 1 108 . 2 9 / 9 1. 3 25R83 B 4 .91 1069. 2 / nArm1 H2 2000 20150E 30/762 _9WI 3QI762 4811219.2 361914,A 48/12192 4Yaii W1 12.U317,5 12.E (I 10,51266,7 12.513175 10 51266,7 1669/423.9 19.1814812 16.69/423.9 (InIM) w2 14.fJ370.8 14.6r370A 13.513429 14.6d370.8 1351342.9 21.62/554.2 2N609.6 2187J554.2 Degh (ro..Imm) 7,09/190,1 7.09/180.1 6.3/160.1 7.0180.1 6.3/160.1 1006/255.5 0,061255.5 10.06/266.5. WeigNJaisAili 2019.07 2M,11021 39}•17.69 20/9,07 SWIM 10I 1S3/80.33 140/63.5 GENERAL° General: PomrSystems, Inc. • S45VQ9290 HWY.59, Waukesha, 0 53189 • generac.com @2p15QmwsPorver6yAeme,li�, Allditorn"ad. All speclllcWmsnsubjmtWchwilawatgWr4 a aWWfno.3205�8 Krdedr SA. 07r&15 r / --------------- AUTOMATIC TRANSFER SWITCH — — — — — — — — — — — — — — J 10'-0" SLAB LENGTH 1'-3" 1 2'-47/8" BATTERY12V 24F MIN. 625 CCA = STUB -UP AREA O_ 'S 0 THIS END TOWARDS EXISTING HOUSE AIR INLET OF GENERATOR OUTDOOR INSTALLATION ONLY SCANNED BY St Lizie C&S4 wr,— U 1 N L 41 p tiq - -J v Imo. dxe%;;�Z EE J <C J LU �0 LUW=1 H �H Z2D= W 0 o = QW u)mccooWD0 Ir- zwayz Wz U=¢W'Se�[P LU H unow zZZ�w F—rp=z U0I—�JI-W=Ow0OL > QZJ'SQI=--0z2Z OE 0 Q=LL<5ZWiz¢o ¢ owwSO =NW>=-= ¢o���Zz0o LQ� z WZWOQiZ<U_o w UJ—— FWC�Z —_JZ1W Z<W C7z>00� Zt-W= C.)WOUOcn�oOinrzWc.9 �z LULLWLL O�2O=)-=OOO wa¢P U UHmO-iY� W¢NiLC) >u-dot- w �UZLLON}O}HOU t— LLLLOW'Cfn>~=WW <dWZZ00LL6J=U_� OWU)=WO<LO`3: 0 J0Wzmw = WLL�QWZC7WCCW� J LLOU 20<7F�a-O j i WU J Z 0 � 0o0-2OW=¢0=U WZ�LL'Lu—�,wZLUZ� U) WU)6�Q_Jz�gz W �WQ2UQ(�2IOU U M 00 O U/ L.L U U BT.LUCIE COUNT' PLANS OBLDG:___— U DATE: ELE ' _/ Y z DATE: O PLUIB DATE: MECH:� U DATE: 00 M M z U J 0 C L L L w 0 "0 U LD �U H .a) >LLJ a) J 0 � W .� JI N MIl MAR 01 2018 ST. Lucie County, permitting 2/27/18 9:06:04 PM G-1 SCaie As indicated