HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS80THome i Log In
^r ---;--U u5er
BtR+
c 1
' b
4BVa NGT�E- AeOor CE t�k GHNn9iViS10HS CGWtrAc(7Bvti
:r
'Qjgduct'Aooroval Menu > Product or''Aooliwtiorr�Swkh
>;Aooiication List>.Applfcatlon Detdil
q
FL #
FL9777-Ri1'
- _
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived"
"D
Product. Manufacturer
Oweris Corning.
Address/Phone/Email
One Owens.Corriijrg ?arkway
Toledo; OH 43659
(740):404-7829
greg: keeferbow.enscoming.com.
Authorized Signature
Greg Keeler,
greg.keeler@owenscorningcom
Technical A'epresentative '
Address/Phone/Email
0
Assurance; Representative
Quality
Address/Phone/Email
Category
Roofing
.Subcategory
Undedayments
JCompllance
Method
Evaluation -,Report from'a. Florida Registered Architect or a, Ucensed. Florida
/.ten
Professional Engineer
Evaluation. Report- Hardcopy Received
Florida Engineer or Architect Name who developed the ZacharyR.: Priest
Evaluation Report
Florida Ucense 044021
Quality Assurance Entity, UL LLC
Quality -Assurance Contract Expiratfon Date 12/31/2620
Validated By Locke -Bowden
y. Validation Checklist-- Hardcopy Received
Certificate=of Independence FL9777 R11 COI OCR14002 8a 2017 FBG Evaluation Report Weaiheriock
Non-HVHZrodf.'
Referenced Standard and Year of St idard Year
( ) Standard.
ASTM D 19701
2015
ASTM'D 226
2009
ASTM. G 155
2005,
TAS 103
1995
UL1897
2012.
Equivalence .of Product Standards
Certified By
Sections from'the Code
Product Approval Method Method 1 Option, D
Date Submitted
10/11/20,17
Date Validated
10/11/2.017
Date Pending MC Approval
10 17/201.7
Date Approved
12/12/2017'
Summary of Prnduets
.FL #
Madel; Number or Name
Description
:9777.1
Weatherlock G,
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9777 R11 II OCR14002.8a•2017'FBC Evaluation Report
Weatherlock Non-HVHZ.Odf
:Impact Resistant: N/A
Verified By: ;Zachary R., Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes.
Other::See.evaluation-report for,limits.of use.
Evaluation Reports
FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HYHZ.Odf
Created by IndependentThird. Party: Yes.
9777.2
WeatherLock G (High Tear-)
Weatherproofing Underlayment
Limits of. Use
Installation Instructions
Approved for use in HVHZ: No.
FL9777 1111 Ii OCR,14002 8a 2017 FBC Evaluatlon Re or
Weatherlock. Non-HVHZ
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By.: Zachary. R. Priest 13E-74021
Design Pressure: N/A
Other: See, evaluation report'for limits of Use.
Created by IndependentThird Party: Yes
Ev_al'uation, Reports
F(9777 R11 AE OCR14002 8a 2017 FBC Fval'uation Rewrt
;Weatherlock Non-HVHZ.pdf
Created by Independent Third, Party: Yes
9177.3
Weathetlock,MAT
,Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved'for use in HVHZ: Yes
,FL9777' R11 II OCRI4002 8b 2017 FpC EvaluatiobAeport
Weatherlock HVHZ.odf'
Approved for use-outside.HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest74021
Design Pressure: 'N/A
Created by Independent Third Party: Yes.
Other: See evaluation report for'ilmits of use.
Evaluation Reports
FL9777` R11 -AE' OCR14002_8b 2017, FBC Evaluation Report
Weatherlock HVHZ.Odf
Created by Independent Third Partyi Yes
9777.4
Weatherlock MAT
.Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use.in HVHZ., No'
Approved for use.outside'HVHZ:, Yes
FL9777 R11 II OCR14002:8a 2017 FBC Evaluation'Reoort
Weatherlock Non-HVHZ.Odf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for Ilinits of use,
Verified By: Zachary R. Priest 7402.1
Created by Independent Third Party: Yes
Evaluation Reports
FL9777. Rll AE OCR14002.8a 20177FRC Evaluation Report
Weatherlock,Non-HVHZ, Ddf
:Created by Independent Third Party: Yes
97775
WeatherLock Metal
Weatherproofing Underlayment
limits of Use
Installation. Instructions
Approved for use in HVHZ: No
Approved for, use outside HVHZ: Yes
FL9777 - 811 II OCR14002� 8a 2017'FBC Evaluation Report
Weatherloek'Non-HVHZ.Odf
Impact Resistant: N/A
Verified By, Zachary R: Priest PE-74021
.Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See�evaluatiun"report for limits of`use.
Evaluation Reports
FL9777 R11 AE .00it14002.8a 2017 FBC Evaluation'R mrt
Weatherlock Non-HVHZ:Odf
Created. by Independent Third. Party: Yes
9777.6;
WeatherLock' Metal
Weatherproofing Underlayment
Limits of Use,
iInstaliation Instructions
Approved for use in HVHZ: Yes
Approved -for use outside-HVHZ: No
FL9777 -RII 'II O R1400 -ah m 7 FBC Evaluation R !�
Weatherlock HVHZ:pdf
Irilipact Resista-fifiNA Verified By., Zachary' R. Priest PE7-74021
Design .Pressure:: NIA Created by.irideperident Third -Party.., Yes
:Other: See evaluation report for limits of use. EValuididn Rdpdfts
FIL0777 R11 AE QdR14061,86 2017 EBC EV61gati6n Reij6rt
Weathercock HVHZpd-
Created; WIndeDefident: Third, Party: Yes
9777,7 WeatherLoduSpedalty Tile & Metal
Elm-fts of Use
Approved for use In HNNU No,
Approved for use outside.HVHZ: Yes
Impail R,esl.sta.nt:,N/A
a6slign Preqsurd: +0/w142.5.
Other. See,,evaluatwn report The limits of use.
Verified BY!; Zachary R.. Priest74021
Createcf 6�. Independent thirdRatt'y"., Yes
Cr6atOd
Back t(e>if
Yes
Cantnt us I., 260I Blair Store Mad. Tallahassee FL 32399 M66d: 850-47-18
The State of Florida Is an/AAjEEO eMpiOYer- CbMiGlit 2&726State of ta 0 k.::,gefund .
Fldridg. : Prjyacy,Stajgrr�n �.,Acctsslblliti, S taStatementiji n
,Under Floriclat'la% ernall addresses' -a_Wpbbk records. if you do not wantyour e-mail address released In response to a-puibilc--records request, do not'serfd electriahk
mail 6 this an*. lnviadcontaq *e.oM;p.'by phone or Wtradit(ohol mall. if.96whave afty,quastloni, please 6nitacMSS6,487.139S. "Pursuant to.'Sectlon
455-2715(i),;FI.6ifda,StatLit",'.effe6t[vii oct6ber-1, 2012ylicensees licensed underChapter 455, FS:'must proyldeahe oppartment-with an email address lfth4y fiav4
one: The ernalls provided;may be used -for official communication with'the'llcensee.'HoweVer.einaWad6eises are public record: -Ifyotl do no6NIsh'tdsuppIV. a,p"nal
address, please. provide the ,Deplaitin�tMtti. an en4laddress w6ldi, canbe'roade availible•to the public. To detertnifte If VQU are a( licensee Under Chaptef 455, F.S.,
please di&hdhe.
Produa Approval Accepts:
CREEK
TECHNICAL SERVICES, L..LC
EVALUATION REPORT -
Certificate of Authorization No.' 29894
17520.Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING -CODE, C EDITION (2617)
Manufacturer: OWENS CORNING ROOFING'AND ASPHALT LLC
1.O.wens Coming Parkway
Toledo, OH 43657
(800) 438-7466
www.owenseorning.com
Manufacturing location: Brentwood,,NH
Houston, TX;
Quality Assurance: ULLLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1501A.1
Properties:
Physical properties
REFERENCES
Issued October 11,. 2017
ga&
Report No.
Standard
Year
.PRI Construction
MaterialsTechnologfes (TST5878)
NEi-039-02-01
ASTM D.1970
2015
PRI Construction:Materials
Technologies (TST5878)
NEI-042-02-01REV2
A$TWP 1970
2016
PRI Construction,
Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI .Construction
Materials;Technologies (1'ST5878)
NEI-045-02-01
ASTM-G.155
2005a
PRI Construction
Materials Technologies (TST5878)
'NEI=053-02-01
TAS 103
1995
PRI Construction
Materials Technologies (TST5678)
NE1-053-02-.01.
ASTM G 155
2005a
PRI Const`uction
Materials:Technologies (TST5878)
NEI=093-02-02
ASTM D 1970
2015
PRI Constiactiori
Materials Technologies (TST5878)
0017-213=02r01
-ASTM D 1623
2009
PRI Constructi6n-Mai6dals!Technologies
(TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction
Materials Technologies (7ST5878)
0CF-252 62-01
ASTM D 4798
2001
PRI Construction
Materials Technologies (TST5878)
OCF-252=02=01
ASTM D 1970
2015
PRI Construction
Materials -Technologies (TST5878)
IOCF-253-02-02,
ASTM D 1970
2015
PRI Construction
Materials Technologies (TST5878)
OCF-272-02-61
TAS 103
1995,
PRI Construction
;Materials Technologies (TST5878)
OCF-296-02.02
ICGES AC 186'
2012
ICC-ES;AC 48
:2012
PRI Construction
Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 19.70
2015
PRI Construction
Materials Technologies (TST5878)
0CF-316-;02-61
,ASTM D 1970
201.5
PRI Construction
Materials Technologies (TST5878)
OCF-320-02;01
TAS 1.03
1995
PRI Construction
Materials Technologies (TST5878)
0CF-320-02=01
ASTM G 1.55
20056
PRI Construction
Materials Technologies (TST5878)
0CF=321=02-01'
ASTM D 1623
2069
PRI Construction
Materials Technologies (TST5878);
OCF7322-02-0.1
UL ,1897
2012
PRI Construction
Materials Technologies (TST5878)
0CF-355-02-01.
UL 1897
2012
'Determined to be equivalent to-ASTM D 2264)9, Type I
and 11
OCR14002.8a
1 of 4
This evaluation report is provided for State of Florida product.approval-under Rule 6,1 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance, throughoutthe duration for which this report is valid.
This evaluation report does not express nor-tmply warranty, installation, recommendeduse, or other product attributes that are not
specificallyaddressed herein.
OWENS CORNING ROOFING AND ASPHALT LLC;
cREEK WeatherLockilD -Self-Sealing Ice i Water Bafriers,
TECHNICAL SERVICES, LILC
PRODUCT DESCRIPTION AND LIMITS OF WE
WeatheirLock@D G
WeatherLocW G, is an ASTM D 1970 self-adhesive underlayment,constructed from SBS
(Brentwood, NH)
modified asphalt, -aft6rglass mat: reinforcement and, surfaced with giaribles. The
product is supplied in 2=sq-, rolls: with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock& Q is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck -shall be limited to a
maximum 30 days,
WeatherLock@ Mat
WeatherLockO Mat is, an ASTM D WO self-adhesive.underlayment constructed from
(Brentwood,. NH or
SBS modified' asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston,
$q. rolls, with nominal. dimensions'of 3-ft x, 33.3-ft and 2sq'. rolls, with nominal dimensions;
of,3-ft x 66.7-ft..
WeatherLockO Mat is permitted lobe used; as prescribed in FBC Section 1 - 607.1.1 for
mechanically attached roof coverings. Exposure Ion the. roof deck shall be, limited to a
maximum-30 days.
WeatherLdckO Metal'
WeatherLock@, Metal is an ASTM D. 1. 970 self-adhesive, unded-ayment constructed from
.
(Brentwood', NH)
'SBS: modifie , clasp asphalt With a fiberglass mat re inforcement and plastic: film surface. The
product is supplied in 2.0- sq. rolls with nominal dimensions of 3-ft x 66.74".
WeatherLock(DUBtal is permitted to be used as prescribed in FBC Section 1607.1.1 for
mechanically attached roof coverings. Exposure on the, roof deck :shall be limited to a
maximum 9.0 days.
WeatherLock@
WeatherLockg Specialty, Tile & Metal is an ASTMD 1970 self-adhesive underlayment
Specialty Tile a & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH. or,
The product is. supplied in 2.14 sq, rolls with, nominal dimensions of 3-ft x 7163-tft.
Houston, 7X)
WeA therLockO Specialty Tile & Metal Is permitted to be used as prescribed in FBC
Section 1507.1.1. Weathertocko specialty tile & Metal is permitted to be used with
adhered clay or concrete tile f.66fitig I using either ICP Adhesives, Polyset AH-160 (ICP
.Adhesives and Sealants, Inc.) or TILE BONDTm Roof Tile Adhesive, (The Dow Chemical
Company). Exposure on theroof'deck.-shall be, limited to a maximum 90 days:
The maximum roof slope shall be 6:12 when used with .clay or concrete tile installations
without battens. tile shall be stored. on battens for roof Oopes: gt6atijr than 6:12. Tiles
,shall not be stacked greater 10 riles,oer stack.
WeatherLock@ G (High Weathed-odW G (High Teat) is a self.adhered,. underlayment used'as'an alternative to
Tear) ASTM D 226, Type I or Type 11 roofing felt and, ASTM I D 1970 self -adhering polymer
(Houston, modified bitumen underlayment. The underlpyrnent is composed of SBS modified
asphalt with a fiberglass mat internal. reinforcement and is surfaced with granules. The
product Is, supplied with a nominal thickness of 50 mils in 1.95-sq rolls with, nominal
dimenslions of 3.;ft-x 66-ft.
Weathi§fLock@ G (High Tear) is permitted to be used as prescribed in FBC Section
11507J.1 for me.chanically,Eittached roof coverings. Exposure on, the roof deck shall be
limited to a maximum 30 days.
11
2 of 4
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify - CREEK
Technical Services, LLC of any product changes. or quality assurance changes throughpu_(th�e-dqratf.on for which this report is valid.
This evaluaflon.report does not expess nor irriply warranty, installation, -recommended 'Use, of other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock®'Self-Sealinglce 8 Water Barriers
TECHNICAL, $ERVICES, LLC
PRODUCT APPLICATION
Min: Roof Slope:- 2:12 in accordance with the FBC
Application.: All underfayments shall be installed in accordance with the-FBC.
Decksubstrates shall be clean; dry, ,and free from any irregularities and debris. All
fasteners in. the deck shall be' checked for protrusion and correcte.'d prior to untlerieymeRt
application. Prior to beginning installation, the underiaymenf shall be unrolled and
allowed to relax for a minimum of Sr-6 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into ,place, to ensure completel,contact with the deck. The undedayment shall be installed:
with the to
length parallel to the eave, starting at the. eaves. and with minirrium..3" side,
laps and minimum�V end laps'staggered min: 6-ft:from preceding course. Additionally, if
applying Weathert-ockO' Specialty'Tile &.:Metal, end; laps ;shall be primed with ASTM D.
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
:of the lap,
It is permissible,to back nail the ,undedayment 12-inches on -center as needed (nails shall
be; installed perpendicular to deck with the nail heads flush to the top surface of the.
underlayment)..Additionally, WeatherLockO Specialty Tile & Metal shall. be back. nailed`
when installed on roof -slopes greater thin 3:12.
Min.. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum'
Temperature: application temperature,
WIND RESISTANCE
The: Maximum Design Pressures -shown belowwere calculated using a 2'.--.1.-m4rgin of safety per FBG Section 150.4:9
Undedavment System No.1 — Weathe_rLbek Specialty Tile. & Metal.Oniv
Roof Deckf Min. 15/32=inch CDX plywood attached to wood supports spaced. a� maximum 24I o.c:
Underlayment: WeatherLockO Specialty Tile &. Metal shall be, applied in accordance with
manufac'tut6t's installation .instructions to the fastened 'deck- and backnailed along the
selvage .with, minimum 12ga., 1-114-1nch, galvanized' ring shank roofing nails through
optionally primed„ 32ga. x 1-5/8-inch 0 tin caps spaced 1.2" o.c: The applied
underhgm6nt shall be. rolled with a minimum 751b steel roller immediately following
application.
Maximum Design ,142.5 psf
Pressure:
3 of,4
This evaluation report is provided forState:of Florida product approval under Rule 61G20-3, The manufacturer shall notifg CREEK
Technical Services, LLC of any.product;changes or quality assurance changes throughout the duration for which this report is valid.,
This evaluation report does not express: nor imply warranty, -installation, 'recommended' use, or other product attributes that are not
specifically addressed herein.
C j� OWENS-CORNING ROOFING -AND ASPHALT LLG
G R EILi I' Weather, 00. Self -Sealing Ice B Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of evaluatedproduct shall comply with -this report; the FBC, -and the manufacturers published
application instructions. Where discrepancies exist between these .sources, the more restrictive. and FBC
compliant installation detail: shall prevail.
4) The roof deck. shali.be-constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck.area shall be properlyveritilated:in accordance with the FBC requirements.
6) All side lap seams shall be, installed to shed water from the deck.
7) The underlayment maybe used as.described in. other current FBC,produci approval documents.
8) Design -wind load pressures shall be determined for components and cladding in accordance with FBC.
1609.
9), The roof deck shall be designed by others In •accordance with FBC requirements to' resistthe design wind
load pressures for components and cladding.
10) ,Maximum Design Pressures for a given ,und4dayment shall meet or exceed the design. wind loads
determined for the roof assembly.
11:) All products listed 'in :this reportshall be manufactured under a qualitysassurance program incompliance with
Rule 61 G20=3.
COMPLIANCE STATEMENT
The products evaluated herein by:Zachaty R. Priest, P.E. have demonstrated compliance with the Florida,, Building:
Code 6"' Edition (2017) as evidenced' in.the referenced documents:submitted by named ;manufacturer:,
Pi
xGENSF
.`' No 74691:
S:TAT E 0 F
�'. A P
CERTIFICATION OF INDEPENDENCE
y 2017..10.
09:06:29
_04'00'
Zachary R; Priest, P:E.
Florida'Registration No; 74021
Organization'No. ANE9641
CREEK Technical Services, LLC does not have; nor will it acquire; a financial interest -in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,, LLC is not owned, operated,,or controlled •by any *company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, .P E. does not have; nor -will acquire,, a financial interest in any company manufacturing, or distributing, products
under this' evaluation.
Zachary R. Priest, P.E. does not,have;, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002:8a
Of
This evaluation report is,provided-for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical' Services, LLC of any product.changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does.not express nor imply warranty, installation, recommended us e,• or other product attributes that are. not
specifically addressed herein.