Loading...
HomeMy WebLinkAboutEXISTING PLAN VIEWSCANNED BY St Lucie you* MEAN HIGH WATER LINE AT FACE OF EXISTING SEAWALL OF I' END +AO l 0 w Permit Number y q r 56-3597377001-EE b p Southeast District y o?� 0Ny NOTES: 1. ELEVATION DATUM IS MLW MHW = -0.3 NAVD 88 MLW = -1.68 NAVD 88 2. NO SUBMERGED RESOURCES WITHIN PROJECT AREA 1?s Environmental S ervices, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone:772-215-3997 -Fax:772-879-4520 www.disenvironmentalservices.com SHORELINE LENGTH 156± L.F. Existing Plan View Debra Fasnacht 902 Jackson Way Fort Pierce, Florida PCN# 1423-802-0017-000-6 SCALE: 1" = 20' DEC 2017 SHEET 3 of 5 INDIAN RIVER 35t L.F. OF NEW SEAWALL TO BE INSTALLED IN SAME LOCATION ' e 4' C ^'-t AS EXISTING SEAWALL OR . M_ANGROV,ES, - ti EXISTING DOCK LANDWARD OF EXISTING SEAWALLS '1 H `a v ,yob` 121t L.F. OF NEW SEAWALL TO BE INSTALLED WITHIN 18- OF EXISTING SEAWALL SHORELINE LENGTH 156t L.F. S pF E�ri, 41 VA r� Permit -Number y A r R 56-359737-001-EE b d O p Southeast District y 'Y ?� SOS• `r O NOTES: � Z � Z S 1. ELEVATION DATUM IS MLW MHW = -0.3 NAVD 88 MLW = -1.68 NAVD 88 2. PROPOSED WORK IS TO INSTALL 121t L.F. OF NEW SEAWALL WITHIN 18" OF THE EXISTING SEAWALL AND INSTALL 35t L.F. OF NEW SEAWALL IN THE SAME LOCATION OR LANDWARD OF THE EXISTING SEAWALL (DOES NOT INCLUDE RETURNS) 3. NEW SEAWALL DESIGNED TO AVOID MANGROVE IMPACTS Environmental Proposed Plan View Debra Fasnacht Inc. ervices, 902 Jackson Way 1901 SW Yellowtail Avenue Fort Pierce, Florida Port Saint Lucie, FL 34953 PCN# 1423-802-0017-000-6 Phone:772-215-3997 Fax:772-879-4520 www.disenvironmentalservices.com SCALE: 1" = 20' DEC 2017 SHEET 4 of 5 PROPOSED SEAWALL (NEW SEAWALL SAME LOCATION AS EXISTING SEAWALL OR LANDWARD OF EXISTING SEAWALL) MHW SUBSTRATE TYPICAL CROSS SECTION VIEW A -A MHW MLW ENY r� o� w � Permit Number y 4 r 56-359737-001-EE b d p p Southeast DistrictVA y � q 'S ?4 V. ti It O V.tvss' .L NOTES: 1. ELEVATION DATUM IS MLW TYPICAL CROSS SECTION VIEW B-B MHW = -0.3 NAVD 88 MLW = -1.68 NAVD 88 2. NEW SEAWALL TO BE WITHIN 18" OF EXISTING SEAWALL WETFACE TO WETFACE FOR 121± L.F. AND IN THE SAME LOCATION AS EXISTING (OR LANDWARD) FOR 35± L'.F. 3. NO SUBMERGED RESOURCES PRESENT Environmental Cross Section Views T ervices, Inc. Debra Fasnacht 902 Jackson Way 1901 SW Yellowtail Avenue Fort Pierce, Florida Port Saint Lucie, FL 34953 PCN# 1423-802-0017-000-6 Phone:772-215-3997 Fax:772-879-4520 www.dlsenvironmentalservices.com SCALE: 1" = 2' DEC 2017 SHEET 5 of 5