HomeMy WebLinkAboutENERGY EFFICIENCY CODE� � 1
FORM R405-2014
i�6�,-ooau
SCANNED
BY
St Lucie C®untv
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: TIKNIS AND CAUFIELD RESIDENCE,
Builder Name: PARADISE HOMES
Street: 9629 LANDINGS DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, 34986
Permit Number. 1803-0020
Owner. JAMES TIKNIS AND THOMAS CAUFJELD
Jurisdiction: ST LUCIE COUNTY
°
Design Location: FL, Fort Pierce i
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3798.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 .3338.60 ft2
3. Number of units, if multiple family 1
b. Frame- Wood, Adjacent
c. N/A
R=11.0 460.00 ftz
R= ftz
4. Number of Bedrooms 3
d. NIA
R= ftz
5. Is this a worst case? No
10. Ceiling Types (3193.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 3193.00 ftz
6. Conditioned floor area above grade (ftz) 3193
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0 i
ntz
11 Ducts
R
7. Windows(496.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU 1 AND 2 6 200
a. U-Factor: Sgl, U=0.62 ! 254.67 ftz
b. Sup: Attic, Ret: Attic, AH: AHU 1 AND 2 6 125
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.69 128.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
58.5 SEER:15.75
c. U-Factor: Sgi, U=0.58 72.00 ftz
b. Central Unit
24.0 SEER:16.00
SHGC: SHGC=0.24
13. Heating systems
kBtufhr Efficiency
d. U-Factor: other (see details) 42.00 ftz
a. Electric Strip Heat
34.0 COPA.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 1.500 ft.
Area Weighted Average SHGC: 1 0.224
14. Hot water systems
8. Floor Types (3193.0 sqft.) Insulation Area
a. Electric
Cap: 80 gallons
a. a. Slab -On -Grade Edge Insulation R=0.0 3193.00 ftZ
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
None
Glass/Floor Area: 0.156 Total Proposed Modified Loads: 105.79
P n QS
Total Baseline Loads: 109.85
M
I hereby certify that the plans and specifications covered by
Review of the plans andST,g7�
this calculation are in compliance with the Florida Energy
specifications covered by this
�1 _ ; O
Code.
calculation indicates compliance
PREPARED BY:
with the Florida Energy Code.
Before construction is completed.
- >�
DATE: -"1
this buildingwill be inspected for
P
1�
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Erie r y Code.GpDv'
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
ALL PROJECTS require. an envelope leakage test report with envelope leakage no:greater than 7 ACH50 (R402.4.1,2).
5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant So g
F."
-� 4�w {�
FORM R405-2014
PROJECT
Title:
TIKNIS AND CAUFIELD RESI
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
3193
Lot #
Owner Name:
JAMES TIKNIS AND THOMA
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
PARADISE HOMES
Rotate Angle:
0
Street:
9629 LANDINGS DRIVE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fen:
No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Single-family
I
FL, 34986
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
Daily Temp
1/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2265
24508
2
AHU 2
928
10344
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
GREAT ROOM
590
6900 No
0
1
Yes
Yes
Yes
2
FOYER
63
1008 No
0
1
Yes
Yes
Yes
3
KITCHEN
314
4396 Yes
0
1
Yes
Yes
Yes
4
DINING ROOM
224
2464 No
0
1
Yes
Yes
Yes
5
AHU 1 AND 2
18
180 No
0
1
No
Yes
Yes
6
LAUNDRY
122
1220 No
0
1
Yes
Yes
Yes
7
CLST 3
18
180 No
0
1
Yes
Yes
Yes
8
BEDROOM 3
195
1950 No
0
1
1
Yes
Yes
Yes
9
HALLWAY
88
880 No
0
1
Yes
Yes
Yes
10
BATH 3
78
780 No
0
1
Yes
Yes
Yes
11
CLST 2
26
260 No
0
1
Yes
Yes
Yes
12
BEDROOM 2
182
1820 No
0
1
1
Yes
Yes
Yes
13
CABANA BATH
100
1000 No
0
1
Yes
Yes
Yes
14
STORAGE
247
2470 No
0
1
Yes
Yes
Yes
15
MASTER SUITE
440
4840 No
0
1
1
Yes
Yes
Yes
16
M WIC 1
48
480 No
0
1
Yes
Yes
Yes
17
MWIC2
48
480 No
0
1
No
Yes
Yes
18
M BATH
176
1760 No
0
1
Yes
Yes
Yes
19
M TOILET
40
400 No
0
1
Yes
Yes
Yes
20
M HALL
20
200 No
0
1
No
Yes
Yes
21
STUDY
156
2184 No
0
1
Yes
Yes
Yes
5/2/2018 2.46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7
FORM R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
GREAT ROOM
12 ft
0
590 ft2
1
0
0
2 Slab -On -Grade Edge Insulation
FOYER
9 ft
0
63 ftz
____
1
0
0
3 Slab -On -Grade Edge Insulation
KITCHEN
12 ft
0
314 ftz
__._
1
0
0
4 Slab -On -Grade Edge Insulation
DINING ROOM
14 ft
0
224 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulation
AHU 1 AND 2
i
1 ft
0
18 ft2
1
0
0
6 Slab -On -Grade Edge Insulation
LAUNDRY
8 ft
0
122 ft2
_.__
1
0
0
7 Slab -On -Grade Edge Insulation
CLST 3
2ft
0
18 ftz
1
0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 3
13 ft
0
195 ftz
_-__
1
0
0
9 Slab -On -Grade Edge Insulation
HALLWAY
4 ft
0
88 ftz
10SIab-On-Grade Edge Insulation
BATH 3
8 ft
0
78 ft2
__-_
1
0
0
11SIab-On-Grade Edge Insulation
CLST 2
2ft
0
26 ft2
1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 2
17 ft
0
182 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
CABANA BATH
15 ft
0
100 ftz
1
0
0
14SIab-On-Grade Edge Insulation
STORAGE
25 ft
0
247 ft2
1
0
0
15SIab-On-Grade Edge Insulation
MASTER SUITE
32 ft
0
440 ft2
1
0
0
16SIab-On-Grade Edge Insulation
M W IC 1
8ft
0
48 ft2
1
0
0
17Slab-On-Grade Edge Insulation
M W IC 2
1 ft
0
48 ft2
-___
1
0
0
18SIab-On-Grade Edge Insulation
M BATH
19 ft
0
176 ft2
1
0
0
19Slab-On-Grade Edge Insulation
M TOILET
18 ft
0
40 ft2
_ _
1
0
0
20SIab-On-Grade Edge Insulation
M HALL
1 ft
0
20 ft2
__
1
0
0
21SIab-On-Grade Edge Insulation
STUDY
14 ft
0
156 ftz
____
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
v # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip Barrel file 3571 ft2
0 ft2
Medium
0.2
No 0.9
No
0
26.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1
In)
Area
RBS IRCC
E- 1 Full attic
Vented
150
3193 ft2
N N
5/2/2018 2:46.PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 7
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) GREAT ROOM
30
Blown
590ft2
0.1
Wood
2
Under Attic (Vented) FOYER
30
Blown
63ft2
0.1
Wood
3
Under Attic (Vented) KITCHEN
30
Blown
314ft2
0.1
Wood
4
Under Attic (Vented ) DINING ROOM
30
Blown
224ft2
0.1
Wood
5
Under Attic (Vented) AHi U 1 AND 2
30
Blown
18fe
0.1
Wood
6
Under Attic (Vented) LAUNDRY
30
Blown
122ft2
0.1
Wood
7
Under Attic (Vented) iCLST 3
30
Blown
18 ft2
0.1
Wood
8
Under Attic (Vented) BEDROOM 3
30
Blown
195 ft2
0.1
Wood
9
Under Attic (Vented) HALLWAY
30
Blown
88ft2
0.1
Wood
10
Under Attic (Vented) BATH
30
Blown
78ft2
0.1
Wood
11
Under Attic (Vented) CLST 2
30
Blown
26 ft2
0.1
Wood
12
Under Attic (Vented) BEDROOM
30
Blown
182ft2
0.1
Wood
13
Under Attic (Vented) CABANA BATH
30
Blown
100 ft2
0.1
Wood
14
Under Attic (Vented) STORAGE
30
Blown
247 ft2
0.1
Wood
15
Under Attic (Vented) MASTERSUITE
30
Blown
440ft2
0.1
Wood
16
Under Attic (Vented) MWIC1
30
Blown
48ft2
0.1
Wood
17
Under Attic (Vented) M W IC 2
30
Blown
48 ft2
0.1
Wood
18
Under Attic (Vented) M BATH
30
Blown
176ft2
0.1
Wood
19
Under Attic (Vented) MTOILET
30
Blown
40ft2
0.1
Wood
20
Under Attic (Vented) MHALL
30
Blown
20ft2
0.1
Wood
21
Under Attic (Vented) STUDY
30
Blown
156ft2
0.1
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing Solar
Below
_ 1
W
Exterior Concrete Block- Ext InstOREAT ROO
4.1
22
0 10
0
220.0 ft2
0
0
0.2
0
2
E
Exterior Concrete Block- Ext Insul FOYER
4.1
9
0 16
6
148.5 ft2
0
0
0.2
0
_ 3
N
Exterior Concrete Block - Ext Insul KITCHEN
4.1
10
0 14
0
140.0 ft2
0
0
0.2
0
4
E
Exterior Concrete Block - Ext Insul KITCHEN
4.1
12
0 14
0
168.0 ft2
0
0
0.2
0
5
W
Exterior Concrete Block - Ext InsMINING ROO
4.1
14
0 11
0
154.0 ft2
0
0
0.2
0
6
S
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
8
0 10
0
80.0 ft2
0
0
0.2
0
_ 7
S
Exterior Concrete Block- Ext Insul CLST 3
4.1
2
0 10
0
20.0 ft2
0
0
0.2
0
8
S
Exterior Concrete Block - Ext InstBEDROOM 3
4.1
13
0 10
0
130.0 ft2
0
0
0.2
0
9
W
Exterior Concrete Block - Ext InsulHALLWAY
4.1
4
0 10
0
40.0 ft2
0
0
0.2
0
_ 10
E
Exterior Concrete Block -. Ext Insul BATH 3
4.1
2
0 10
0
20.0 ft2
0
0
0.2
0
_ 11
S
Exterior Concrete Block - Ext Insul BATH 3
4.1
6
0 10
0
60.0 ft2
0
0
0.2
0
_ 12
S
Exterior Concrete Block - Ext Insul CLST 2
4.1
2
0 10
0
20.0 ft2
0
0
0.2
0
_ 13
S
Exterior Concrete Block - Ext InsiMEDROOM 2
4.1
14
0 10
0
140.0 ft2
0
0
0.2
0
_ 14
W
Exterior Concrete Block- Ext InsSEDROOM 2
4.1
3
0 10
0
30.0 ft2
0
0
0.2
0
15
N
Exterior Concrete Block - Ext InsGIABANA BAT
4.1
10
0 10
0
100.0 ft2
0
0
0.2
0
16
S
Exterior Concrete.Block - Ext InsWABANA BAT
4.1
10
0 10
0
100.0 ft2
0
0
0.2
0
_ 17
W
Exterior Concrete Block - Ext Ins01ABANA BAT
4.1
10
0 10
0
100.0 ft2
0
0
0.2
0
_ 18
N
Exterior Concrete Block - Ext InsuISTORAGE
4.1
13
0 10
0
130.0 ft2
0
0
0.2
0
19
E
Exterior Concrete Block - Ext InsuISTORAGE
4.1
19
0 10
0
190.0 ft2
0
0
0.2
0
5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7
FORM R405-2014
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
_20
S
Exterior
Concrete Block - ExtlnsulSTORAGE
4A
13
0
10
0
130.0.ftz
0
0
0.2
0
_ 21
N
Exterior
Concrete Block - Ext InsitnASTER SUI
4.1
24
Q
11
0
264.0 ft'
0
0
0.2
0
22
S
Exterior
Concrete Block - Ext InsWASTER SUI
4.1
8
0
11
0
88.0 ftz
0
0
0.2
0
_ 23
W
Exterior
Concrete Block- Ext InsWASTER SUI
4.1
20
0
11
0
220.0 ft'
0
0
0.2
0
_24
N
Exterior
Concrete Block - Ext Insul MIWIC1
4.1
8
0
10
0
80.0ft2
0
0
0.2
0
_ 25
N
Exterior
Concrete Block- Ext Insul M BATH
4.1
11
0
10
0
110.0 ft'
0
0
0.2
0
_ 26
E
Exterior
Concrete Block - Ext Insul M BATH
4.1
8
0
10
0
80.0 ft'
0
0
0.2
0
_ 27
N
Exterior
Concrete Block - Ext InsulM TOILET
4.1
5
0
10
0
50.0 ftz
0
0
0.2
0
_ 28
E
Exterior
Concrete Black - Ext InsulM TOILET
4.1
8
0
10
0
80.0 ft'
0
0
0.2
0
_ 29
S
Exterior
Concrete Block - Ext Insul M TOILET
4.1
5
0
10
0
50.0 ftz
0
0
0.2
0
_ 30
E
Exterior
Concrete Block - Ext Insul � STUDY
4:1
12
0
14
0
168.0 ftz
0
0
0.2
0
_ 31
S
Exterior
Concrete Block- Ext Insul STUDY
4.1
2
0
14
0
28.0 ft'
0
0
0.2
0
_32
N
Garage
Frame -Wood LAUNDRY
11
2
10
20.0ft'
0
0
0.2
0
_ 33
E
Garage
Frame - Wood LAUNDRY
11
22
10
220.0 ft'
0
0
0.2
0
34
W
Garage
Frame -Wood STORAGE
11
22
10
220.0 ftz
0
0
0.2
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Wood FOYER
None
.27
6
6 8
40ft'
2
N
Insulated CABANA BAT
None
.27
2
4
8
18.7 ftz
3
N
Insulated 'STORAGE
None
.27
8
8
64 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
W
1
Metal Low-E Single Yes
0.69
0.22
128.0 ft'
1 ft 6 in
1 ft 4 in
None
None
2
N
3
Metal Low-E Single Yes
0.58
0.24
12.0 ft'
1 ft 6 in
1 ft 4 in
None
None
3
E
4
Metal Low-E Single Yes
0.42
0.23
18.0 ftz
1 ft 6 in
1 ft 4 in
None
None
4
E
4
Metal Low-E Single Yes
0.62
0.22
24.0 ft'
1 ft 6 in
1 ft 4 in
None
None
5
W
5
Metal Low E Single Yes
0.58
0.24
48.0 ftz
1 ft 6 in
1 ft 4 in
None
None
6
S
6
Metal Low-E'Single Yes
0.62
0.22
12.0 ftz
1 ft 6 in
1 ft 4 in
None
None
7
S
8
Metal Low-E Single Yes
0.62
0.22
15.0 ft'
1 ft 6 in
1 ft 4 in
None
None
8
W
9
Metal Low-E Single Yes
0.62
0.22
18.7 ftz
1 ft 6 in
1 ft 4 in
None
None
9
S
11
Metal Low-E Single Yes
0.58
0.24
6.0 ft'
1 ft 6 in
1 ft 4 in
None
None
10
'S
13
Metal Low-E-Single Yes
0.62
0.22
15.0 ft'
1 ft 6 in
1 ft 4 to
None
None
11
S
16
Metal Low-E Single Yes
0.4
0.26
6.0 ft'
1 ft 6 in
1 ft 4 in
None
None
12
E
19
Metal Low-E Single Yes
0.62
0.22
30.0 ft'
1 ft 6 in
1 ft 4 in
None
None
13
N
21
Metal Low-E Single Yes
0.62
0.22
16.0 ft'
1 ft 6 in
1 ft 4 in
None
None
14
N
21
Metal Low-E Single Yes
0.62
0.22
15.0 ft'
1 ft 6 in
1 ft 4 in
None
None
15
S
22
Metal Low-E Single Yes
0.62
0.22
40.0 ft'
1 ft6 in
1 ft 4 in
None
None
16
W
23
Metal Low-E Single Yes
0.62
0.22
30.0 ft'
1 ft 6 in
1 ft 4 in
None
None
17
N
25
Metal Low-E Single Yes
0.62
0.22
9.0 ft'
1 ft 6 in
1 ft 4 in
None
None
5/2/2018 2.46 PM EnergyGauge® USA - FlaRes2014 Section.11405.4.1 Compliant Software Page 5 of 7
FORM R405-2014
WINDOWS
Orientation shown Is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
18
19
20
E 28 Metal Low-E Single
E 30 Metal Low-E Single
E 30 Metal Low-E Single
Yes
Yes
Yes
0.58 0.24 6.0 ft' 1 ft 6 In 1 ft 4 In None
0.42 0.23 18.0 ft2 1 ft 6 in 1 ft 4 in None
0.62 0.22 30.0 ft' 1 ft 6 in 1 ft 4 In None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
484 f12 484 ft2
46 ft loft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000485
4066.1 223.22 419.8 .3544 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat
Electric Strip Heat
None
None
COP:1 34 kBtulhr 1
COP:1 17 kBtuthr 2
sys#1
sys#2
COOLING SYSTEM
#
—System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
Split
Split
SEER: 15.7558.5 kBtu/hr 1755 cfm 0.8 1
SEER: 16 24 kBtu/hr 720 cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 80 gal 66.6 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft,
DUCTS
/
#
— Supply—
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
2
Attic 6 200 f(=
Attic 6 125 ft'
Attic
Attic
20 ft' Default Leakage AHU 1 AND (Default) c(Default) c
13 ft2 Default Leakage AHU 1 AND (Default) c(Default) c
1 1
2 2
5/2/2018 2.46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7
FCIRM R405-2014
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan
Heatirig Jan
Feb
Feb
Mar
XMar
A r (]
Apr [
Ma
] May
Jun
Jun
Jul
Jul
r Aug�
[ Aug
Se
I ] Sep
Oct
Oct
Nov
Id Nov
Dec
X�j Dec
Venting Jan
Feb
[Xl Mar
[X]
A r [
11 Ma
[[[ ]]] Jun
Jul
[[[ Au
[ ] Se
Oct
Nov
[ 1 Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
13
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
178
78
78
78
78
78
80
80
80
80
PM
80
80
180
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
180
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating(WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: TIKNIS AND CAUFIELD RESIDENCE Builder Name: PARADISE HOMES
Street: 9629 LANDINGS DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, 34986 Permit Number: 1803-0020
Owner. JAMES TIKNIS AND THOMAS CAUFIELD Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
i
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
Rim joists
Rim ,joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
.sealed to the sub -floor or. drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
5/2/2018 2:47 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Pagel of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
9629 LANDINGS DRIVE, PORT ST LUCIE, FL, 34986
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows" Description
a. U-Factor: Sgl, U=0.62
SHGC: SHGC=0.22
b. U-Factor. Sgl, U=0.69
SHGC: SHGC=0.22
c. U-Factor: Sgl, U=0.58
SHGC: SHGC=0.24
d. U-Factor: other (see details)
SHGC: other.(see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
9. Wall Types -
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
3338.50 ft'
b. Frame- Wood, Adjacent
R=11.0
460.00 ftz
1
c. NIA
R=
ftz
3
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
3193.00 ftz
3193
b. NIA
R=
ftz
Area
c. N/A
R=
ftz
254:67 ft'
11. Ducts
R ftz
a. Sup: Attic, Ret• Attic, AH: AHU 1 AND 2
6 200
b. Sup: Attic, Ret: Attic, AH: AHU 1 AND 2
6 125
128.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
72.00 fF
a. Central Unit
58.6
SEER:15.75
b. Central Unit
24.0
SEER:16.00
Insulation
R=0.0
R=
R=
42.00 ft'
13. Heating systems
kBtu/hr Efficiency
a. Electric Strip Heat
34.0 COP:1.00
1.500 ft.
b. Electric Strip Heat
17.0 COP:1.00
0,224
Area
14. Hot water systems
3193.00 ftz
a. Electric
Cap; 80 gallons
EF: 0.98
ft'
ft'
b. Conservation features
None
15. Credits
None
I certify that this home has complied with the- Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: r Date: �s J i
Address of New Home: z1, ��J�{ ��S D City/FL Zip:P0VtS221 . VW
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 - Section R405A.1 Compliant Software Page 1 of 1