HomeMy WebLinkAboutENERGY EFFICIENCY CODE� � 1 FORM R405-2014 i�6�,-ooau SCANNED BY St Lucie C®untv FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TIKNIS AND CAUFIELD RESIDENCE, Builder Name: PARADISE HOMES Street: 9629 LANDINGS DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, 34986 Permit Number. 1803-0020 Owner. JAMES TIKNIS AND THOMAS CAUFJELD Jurisdiction: ST LUCIE COUNTY ° Design Location: FL, Fort Pierce i County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3798.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 .3338.60 ft2 3. Number of units, if multiple family 1 b. Frame- Wood, Adjacent c. N/A R=11.0 460.00 ftz R= ftz 4. Number of Bedrooms 3 d. NIA R= ftz 5. Is this a worst case? No 10. Ceiling Types (3193.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 3193.00 ftz 6. Conditioned floor area above grade (ftz) 3193 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 i ntz 11 Ducts R 7. Windows(496.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 1 AND 2 6 200 a. U-Factor: Sgl, U=0.62 ! 254.67 ftz b. Sup: Attic, Ret: Attic, AH: AHU 1 AND 2 6 125 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.69 128.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 58.5 SEER:15.75 c. U-Factor: Sgi, U=0.58 72.00 ftz b. Central Unit 24.0 SEER:16.00 SHGC: SHGC=0.24 13. Heating systems kBtufhr Efficiency d. U-Factor: other (see details) 42.00 ftz a. Electric Strip Heat 34.0 COPA.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 1 0.224 14. Hot water systems 8. Floor Types (3193.0 sqft.) Insulation Area a. Electric Cap: 80 gallons a. a. Slab -On -Grade Edge Insulation R=0.0 3193.00 ftZ b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits None Glass/Floor Area: 0.156 Total Proposed Modified Loads: 105.79 P n QS Total Baseline Loads: 109.85 M I hereby certify that the plans and specifications covered by Review of the plans andST,g7� this calculation are in compliance with the Florida Energy specifications covered by this �1 _ ; O Code. calculation indicates compliance PREPARED BY: with the Florida Energy Code. Before construction is completed. - >� DATE: -"1 this buildingwill be inspected for P 1� compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Erie r y Code.GpDv' OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 ALL PROJECTS require. an envelope leakage test report with envelope leakage no:greater than 7 ACH50 (R402.4.1,2). 5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant So g F." -� 4�w {� FORM R405-2014 PROJECT Title: TIKNIS AND CAUFIELD RESI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3193 Lot # Owner Name: JAMES TIKNIS AND THOMA Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: PARADISE HOMES Rotate Angle: 0 Street: 9629 LANDINGS DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fen: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family I FL, 34986 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2265 24508 2 AHU 2 928 10344 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 GREAT ROOM 590 6900 No 0 1 Yes Yes Yes 2 FOYER 63 1008 No 0 1 Yes Yes Yes 3 KITCHEN 314 4396 Yes 0 1 Yes Yes Yes 4 DINING ROOM 224 2464 No 0 1 Yes Yes Yes 5 AHU 1 AND 2 18 180 No 0 1 No Yes Yes 6 LAUNDRY 122 1220 No 0 1 Yes Yes Yes 7 CLST 3 18 180 No 0 1 Yes Yes Yes 8 BEDROOM 3 195 1950 No 0 1 1 Yes Yes Yes 9 HALLWAY 88 880 No 0 1 Yes Yes Yes 10 BATH 3 78 780 No 0 1 Yes Yes Yes 11 CLST 2 26 260 No 0 1 Yes Yes Yes 12 BEDROOM 2 182 1820 No 0 1 1 Yes Yes Yes 13 CABANA BATH 100 1000 No 0 1 Yes Yes Yes 14 STORAGE 247 2470 No 0 1 Yes Yes Yes 15 MASTER SUITE 440 4840 No 0 1 1 Yes Yes Yes 16 M WIC 1 48 480 No 0 1 Yes Yes Yes 17 MWIC2 48 480 No 0 1 No Yes Yes 18 M BATH 176 1760 No 0 1 Yes Yes Yes 19 M TOILET 40 400 No 0 1 Yes Yes Yes 20 M HALL 20 200 No 0 1 No Yes Yes 21 STUDY 156 2184 No 0 1 Yes Yes Yes 5/2/2018 2.46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation GREAT ROOM 12 ft 0 590 ft2 1 0 0 2 Slab -On -Grade Edge Insulation FOYER 9 ft 0 63 ftz ____ 1 0 0 3 Slab -On -Grade Edge Insulation KITCHEN 12 ft 0 314 ftz __._ 1 0 0 4 Slab -On -Grade Edge Insulation DINING ROOM 14 ft 0 224 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation AHU 1 AND 2 i 1 ft 0 18 ft2 1 0 0 6 Slab -On -Grade Edge Insulation LAUNDRY 8 ft 0 122 ft2 _.__ 1 0 0 7 Slab -On -Grade Edge Insulation CLST 3 2ft 0 18 ftz 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 3 13 ft 0 195 ftz _-__ 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 4 ft 0 88 ftz 10SIab-On-Grade Edge Insulation BATH 3 8 ft 0 78 ft2 __-_ 1 0 0 11SIab-On-Grade Edge Insulation CLST 2 2ft 0 26 ft2 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 2 17 ft 0 182 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation CABANA BATH 15 ft 0 100 ftz 1 0 0 14SIab-On-Grade Edge Insulation STORAGE 25 ft 0 247 ft2 1 0 0 15SIab-On-Grade Edge Insulation MASTER SUITE 32 ft 0 440 ft2 1 0 0 16SIab-On-Grade Edge Insulation M W IC 1 8ft 0 48 ft2 1 0 0 17Slab-On-Grade Edge Insulation M W IC 2 1 ft 0 48 ft2 -___ 1 0 0 18SIab-On-Grade Edge Insulation M BATH 19 ft 0 176 ft2 1 0 0 19Slab-On-Grade Edge Insulation M TOILET 18 ft 0 40 ft2 _ _ 1 0 0 20SIab-On-Grade Edge Insulation M HALL 1 ft 0 20 ft2 __ 1 0 0 21SIab-On-Grade Edge Insulation STUDY 14 ft 0 156 ftz ____ 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel file 3571 ft2 0 ft2 Medium 0.2 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC E- 1 Full attic Vented 150 3193 ft2 N N 5/2/2018 2:46.PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) GREAT ROOM 30 Blown 590ft2 0.1 Wood 2 Under Attic (Vented) FOYER 30 Blown 63ft2 0.1 Wood 3 Under Attic (Vented) KITCHEN 30 Blown 314ft2 0.1 Wood 4 Under Attic (Vented ) DINING ROOM 30 Blown 224ft2 0.1 Wood 5 Under Attic (Vented) AHi U 1 AND 2 30 Blown 18fe 0.1 Wood 6 Under Attic (Vented) LAUNDRY 30 Blown 122ft2 0.1 Wood 7 Under Attic (Vented) iCLST 3 30 Blown 18 ft2 0.1 Wood 8 Under Attic (Vented) BEDROOM 3 30 Blown 195 ft2 0.1 Wood 9 Under Attic (Vented) HALLWAY 30 Blown 88ft2 0.1 Wood 10 Under Attic (Vented) BATH 30 Blown 78ft2 0.1 Wood 11 Under Attic (Vented) CLST 2 30 Blown 26 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 30 Blown 182ft2 0.1 Wood 13 Under Attic (Vented) CABANA BATH 30 Blown 100 ft2 0.1 Wood 14 Under Attic (Vented) STORAGE 30 Blown 247 ft2 0.1 Wood 15 Under Attic (Vented) MASTERSUITE 30 Blown 440ft2 0.1 Wood 16 Under Attic (Vented) MWIC1 30 Blown 48ft2 0.1 Wood 17 Under Attic (Vented) M W IC 2 30 Blown 48 ft2 0.1 Wood 18 Under Attic (Vented) M BATH 30 Blown 176ft2 0.1 Wood 19 Under Attic (Vented) MTOILET 30 Blown 40ft2 0.1 Wood 20 Under Attic (Vented) MHALL 30 Blown 20ft2 0.1 Wood 21 Under Attic (Vented) STUDY 30 Blown 156ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 W Exterior Concrete Block- Ext InstOREAT ROO 4.1 22 0 10 0 220.0 ft2 0 0 0.2 0 2 E Exterior Concrete Block- Ext Insul FOYER 4.1 9 0 16 6 148.5 ft2 0 0 0.2 0 _ 3 N Exterior Concrete Block - Ext Insul KITCHEN 4.1 10 0 14 0 140.0 ft2 0 0 0.2 0 4 E Exterior Concrete Block - Ext Insul KITCHEN 4.1 12 0 14 0 168.0 ft2 0 0 0.2 0 5 W Exterior Concrete Block - Ext InsMINING ROO 4.1 14 0 11 0 154.0 ft2 0 0 0.2 0 6 S Exterior Concrete Block - Ext InsuILAUNDRY 4.1 8 0 10 0 80.0 ft2 0 0 0.2 0 _ 7 S Exterior Concrete Block- Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.2 0 8 S Exterior Concrete Block - Ext InstBEDROOM 3 4.1 13 0 10 0 130.0 ft2 0 0 0.2 0 9 W Exterior Concrete Block - Ext InsulHALLWAY 4.1 4 0 10 0 40.0 ft2 0 0 0.2 0 _ 10 E Exterior Concrete Block -. Ext Insul BATH 3 4.1 2 0 10 0 20.0 ft2 0 0 0.2 0 _ 11 S Exterior Concrete Block - Ext Insul BATH 3 4.1 6 0 10 0 60.0 ft2 0 0 0.2 0 _ 12 S Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 10 0 20.0 ft2 0 0 0.2 0 _ 13 S Exterior Concrete Block - Ext InsiMEDROOM 2 4.1 14 0 10 0 140.0 ft2 0 0 0.2 0 _ 14 W Exterior Concrete Block- Ext InsSEDROOM 2 4.1 3 0 10 0 30.0 ft2 0 0 0.2 0 15 N Exterior Concrete Block - Ext InsGIABANA BAT 4.1 10 0 10 0 100.0 ft2 0 0 0.2 0 16 S Exterior Concrete.Block - Ext InsWABANA BAT 4.1 10 0 10 0 100.0 ft2 0 0 0.2 0 _ 17 W Exterior Concrete Block - Ext Ins01ABANA BAT 4.1 10 0 10 0 100.0 ft2 0 0 0.2 0 _ 18 N Exterior Concrete Block - Ext InsuISTORAGE 4.1 13 0 10 0 130.0 ft2 0 0 0.2 0 19 E Exterior Concrete Block - Ext InsuISTORAGE 4.1 19 0 10 0 190.0 ft2 0 0 0.2 0 5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _20 S Exterior Concrete Block - ExtlnsulSTORAGE 4A 13 0 10 0 130.0.ftz 0 0 0.2 0 _ 21 N Exterior Concrete Block - Ext InsitnASTER SUI 4.1 24 Q 11 0 264.0 ft' 0 0 0.2 0 22 S Exterior Concrete Block - Ext InsWASTER SUI 4.1 8 0 11 0 88.0 ftz 0 0 0.2 0 _ 23 W Exterior Concrete Block- Ext InsWASTER SUI 4.1 20 0 11 0 220.0 ft' 0 0 0.2 0 _24 N Exterior Concrete Block - Ext Insul MIWIC1 4.1 8 0 10 0 80.0ft2 0 0 0.2 0 _ 25 N Exterior Concrete Block- Ext Insul M BATH 4.1 11 0 10 0 110.0 ft' 0 0 0.2 0 _ 26 E Exterior Concrete Block - Ext Insul M BATH 4.1 8 0 10 0 80.0 ft' 0 0 0.2 0 _ 27 N Exterior Concrete Block - Ext InsulM TOILET 4.1 5 0 10 0 50.0 ftz 0 0 0.2 0 _ 28 E Exterior Concrete Black - Ext InsulM TOILET 4.1 8 0 10 0 80.0 ft' 0 0 0.2 0 _ 29 S Exterior Concrete Block - Ext Insul M TOILET 4.1 5 0 10 0 50.0 ftz 0 0 0.2 0 _ 30 E Exterior Concrete Block - Ext Insul � STUDY 4:1 12 0 14 0 168.0 ftz 0 0 0.2 0 _ 31 S Exterior Concrete Block- Ext Insul STUDY 4.1 2 0 14 0 28.0 ft' 0 0 0.2 0 _32 N Garage Frame -Wood LAUNDRY 11 2 10 20.0ft' 0 0 0.2 0 _ 33 E Garage Frame - Wood LAUNDRY 11 22 10 220.0 ft' 0 0 0.2 0 34 W Garage Frame -Wood STORAGE 11 22 10 220.0 ftz 0 0 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood FOYER None .27 6 6 8 40ft' 2 N Insulated CABANA BAT None .27 2 4 8 18.7 ftz 3 N Insulated 'STORAGE None .27 8 8 64 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Metal Low-E Single Yes 0.69 0.22 128.0 ft' 1 ft 6 in 1 ft 4 in None None 2 N 3 Metal Low-E Single Yes 0.58 0.24 12.0 ft' 1 ft 6 in 1 ft 4 in None None 3 E 4 Metal Low-E Single Yes 0.42 0.23 18.0 ftz 1 ft 6 in 1 ft 4 in None None 4 E 4 Metal Low-E Single Yes 0.62 0.22 24.0 ft' 1 ft 6 in 1 ft 4 in None None 5 W 5 Metal Low E Single Yes 0.58 0.24 48.0 ftz 1 ft 6 in 1 ft 4 in None None 6 S 6 Metal Low-E'Single Yes 0.62 0.22 12.0 ftz 1 ft 6 in 1 ft 4 in None None 7 S 8 Metal Low-E Single Yes 0.62 0.22 15.0 ft' 1 ft 6 in 1 ft 4 in None None 8 W 9 Metal Low-E Single Yes 0.62 0.22 18.7 ftz 1 ft 6 in 1 ft 4 in None None 9 S 11 Metal Low-E Single Yes 0.58 0.24 6.0 ft' 1 ft 6 in 1 ft 4 in None None 10 'S 13 Metal Low-E-Single Yes 0.62 0.22 15.0 ft' 1 ft 6 in 1 ft 4 to None None 11 S 16 Metal Low-E Single Yes 0.4 0.26 6.0 ft' 1 ft 6 in 1 ft 4 in None None 12 E 19 Metal Low-E Single Yes 0.62 0.22 30.0 ft' 1 ft 6 in 1 ft 4 in None None 13 N 21 Metal Low-E Single Yes 0.62 0.22 16.0 ft' 1 ft 6 in 1 ft 4 in None None 14 N 21 Metal Low-E Single Yes 0.62 0.22 15.0 ft' 1 ft 6 in 1 ft 4 in None None 15 S 22 Metal Low-E Single Yes 0.62 0.22 40.0 ft' 1 ft6 in 1 ft 4 in None None 16 W 23 Metal Low-E Single Yes 0.62 0.22 30.0 ft' 1 ft 6 in 1 ft 4 in None None 17 N 25 Metal Low-E Single Yes 0.62 0.22 9.0 ft' 1 ft 6 in 1 ft 4 in None None 5/2/2018 2.46 PM EnergyGauge® USA - FlaRes2014 Section.11405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 WINDOWS Orientation shown Is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 18 19 20 E 28 Metal Low-E Single E 30 Metal Low-E Single E 30 Metal Low-E Single Yes Yes Yes 0.58 0.24 6.0 ft' 1 ft 6 In 1 ft 4 In None 0.42 0.23 18.0 ft2 1 ft 6 in 1 ft 4 in None 0.62 0.22 30.0 ft' 1 ft 6 in 1 ft 4 In None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 484 f12 484 ft2 46 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000485 4066.1 223.22 419.8 .3544 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP:1 34 kBtulhr 1 COP:1 17 kBtuthr 2 sys#1 sys#2 COOLING SYSTEM # —System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 15.7558.5 kBtu/hr 1755 cfm 0.8 1 SEER: 16 24 kBtu/hr 720 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 80 gal 66.6 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft, DUCTS / # — Supply— Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 2 Attic 6 200 f(= Attic 6 125 ft' Attic Attic 20 ft' Default Leakage AHU 1 AND (Default) c(Default) c 13 ft2 Default Leakage AHU 1 AND (Default) c(Default) c 1 1 2 2 5/2/2018 2.46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 FCIRM R405-2014 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Heatirig Jan Feb Feb Mar XMar A r (] Apr [ Ma ] May Jun Jun Jul Jul r Aug� [ Aug Se I ] Sep Oct Oct Nov Id Nov Dec X�j Dec Venting Jan Feb [Xl Mar [X] A r [ 11 Ma [[[ ]]] Jun Jul [[[ Au [ ] Se Oct Nov [ 1 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 13 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 178 78 78 78 78 78 80 80 80 80 PM 80 80 180 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 180 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TIKNIS AND CAUFIELD RESIDENCE Builder Name: PARADISE HOMES Street: 9629 LANDINGS DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, 34986 Permit Number: 1803-0020 Owner. JAMES TIKNIS AND THOMAS CAUFIELD Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT i CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and Rim joists Rim ,joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be .sealed to the sub -floor or. drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 5/2/2018 2:47 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Pagel of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 9629 LANDINGS DRIVE, PORT ST LUCIE, FL, 34986 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows" Description a. U-Factor: Sgl, U=0.62 SHGC: SHGC=0.22 b. U-Factor. Sgl, U=0.69 SHGC: SHGC=0.22 c. U-Factor: Sgl, U=0.58 SHGC: SHGC=0.24 d. U-Factor: other (see details) SHGC: other.(see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) 9. Wall Types - Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 3338.50 ft' b. Frame- Wood, Adjacent R=11.0 460.00 ftz 1 c. NIA R= ftz 3 d. N/A R= ftz 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 3193.00 ftz 3193 b. NIA R= ftz Area c. N/A R= ftz 254:67 ft' 11. Ducts R ftz a. Sup: Attic, Ret• Attic, AH: AHU 1 AND 2 6 200 b. Sup: Attic, Ret: Attic, AH: AHU 1 AND 2 6 125 128.00 ft2 12. Cooling systems kBtu/hr Efficiency 72.00 fF a. Central Unit 58.6 SEER:15.75 b. Central Unit 24.0 SEER:16.00 Insulation R=0.0 R= R= 42.00 ft' 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 34.0 COP:1.00 1.500 ft. b. Electric Strip Heat 17.0 COP:1.00 0,224 Area 14. Hot water systems 3193.00 ftz a. Electric Cap; 80 gallons EF: 0.98 ft' ft' b. Conservation features None 15. Credits None I certify that this home has complied with the- Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: r Date: �s J i Address of New Home: z1, ��J�{ ��S D City/FL Zip:P0VtS221 . VW *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/2/2018 2:46 PM EnergyGauge® USA - FlaRes2014 - Section R405A.1 Compliant Software Page 1 of 1