Field Density Tests of Compacted Soils Method D=6938
Project: . Proposed Single Family Homes Date: July 23, 2018
Address: 9629 Landings Drive, Port Saint Lucie, FL 34986 Order #: 18CMT1946
Area Tested: Building Pad Permit #:
Material Type: Dark Brown Sand with Traces of Rock S"AAlKirn Tech: NH
Client: Paradise Homes Group �� .
p A ei,
Address: 575 NW Mercantile Place, `����®��
Ste. 109 Compaction Req.: •95%
Port Saint Lucie, FL 34986 Proctor Method: ASTM D-1557
Test
#
TEST LOCATION
Probe
Depth
Elev,.
I
Moist
o �o
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
%
Compaction,:
Pass
1
At NE Corner of Pad
12"
FG
7.3
110.9
112.5
12.0
98.6%
Yes
2
At Center of Pad
12"
FG
6.6
111.8
112.5'
12.0
99.4%
Yes
3
At SW Corner of Pad
12"
FG
6.8
109.5
112.5
12.0
97.3%
Yes
4
At SE Corner of Pad
12"
FG
7.1
110.3
112.5
12.0
98.0%
Yes
5
6
7
I
8
9
10
11
12
13
14
Remarks: See Reverse Side
This is a Compact
Legend for Elevation:
2 of 2) for Additional Information for Disclaimer
Test only on the top 12" of the pad and is not a verificatiop of
PR = Proofroll 1,2,3 = 1st, 2nd, 3rd Lift Submitted by:
SL = Springline FL = Final Lift Keith LeBlanc', P:F.
SG = Subgrade BG = Below Grade Federal Engineering 4 Testing,.InP.
BC = Basecourse BOF = Bottom of Footing Florida Reg., No. 59394
TOP = Top of Pipe FG = Finished Grade Certificate of Authorization. #t5471.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and auttiorization for publication of statements,
conclusions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degree' of compaction of the tested layer of
material only. A density does not replace a soil bearing capacity determination. These density tests do not certi r pmpoe8's;ructure.
The results do not preclude or guarantee that future settlement and cracking will not occur. A soil boring test +h ,u cTer1 in oilg`.�vill support the
proposed structure without settlement. If no soil borings have been performed to verify the underlying soils, we recommend t at soi o4i Fpe orrnad to evaluate the
suitability of the underlying soil to support the proposed structure. After laying dormant for a period of 90 days or after heavy rain/storms, retesting rriu`st be'performed on this
work.
PAGE 1 of 2
Com
d Soils Method ®-6938 Disclaimer
Pursuant to your request, Federal Engineering esting, Inc. (FET) has performed a compaction test at the referenced
project on the reverse side. The purpose Pf our test was to determine the degree of compaction of the tested layer of
material only. In no way shall a compaction test replace a soil -bearing capacity determination. A soil boring test must be
performed by the client prior to construction to verify subsoil conditions. Our scope of services only included testing the top
12" of added fill material. FET was not co tracted to perform supervision of the building pad preparation. This testing of
the added fill material does not include an analysis_ of the underlying soil materials to determine if they are capable of
supporting the proposed structure without settlement. This density compaction test does not warranty any underlying soil
materials or conditions below the tested top 12 inches of material. If no soil borings have been performed in the location of
the proposed structure, we recommend performing soil borings below all foundation areas of the proposed structure to
verify the underlying soil conditions.
Environmental analysis of the soil material is not part of the scope of services. If environmental analysis of the soils is
required, we can provide a proposal for pe crming an environmental analysis of the soil materials. The scope of services is
for determination of the degree of compaction of the tested layer of material only. No other analysis is implied or warranted.
Job project specifications were not available at the time the work was performed. Determination of the pass/fail compaction
results are based on current common industry requirements of 95% of the ASTM D-1557 standard for building foundations
and 98% of the AASHTO T-180 standard four paved areas such as roadways and parking lots. If different specifications are
required, Federal Engineering & Testing, Ina. shall be notified.
Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on
other areas or dates. Any subsequent site d disturbances due to water erosion, rain waters, construction activities, utility or
footing excavations, overgrown, vegetatiotraffic and other disturbances will void this test and the site must be re -
compacted and re -tested prior to construction.