Entegra Roof Tile, LLC
1289 NE 91h Ave
Okeechobee, FL 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Plantation Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA #14-1120.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Gaspar J Rodriguez.
1" 01"
MIAMt•DADE COUNTY
NOA No::15-0721.04
U.L,Expiration Date:12108/20
Approval Date: itinvic
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Roofing Tiles
Material:
Concrete
I. PRODUCT DESCRIPTION
Manufactured by
Dimensions
Test Product
Applicant
Specifications Description
Plantation Tile
Length: 16�%,"
TAS 112 Flat concrete roof file for direct deck or
Width: 13"
battened nail -on, mortar or adhesive set
applications.
Trim Pieces
L = varies
TAS 112 Accessory trim; concrete roof pieces for
W =varies
use at hips, rakes, ridges and valley
Varying thickness
terminations. Manufactured for each file
'
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee,FL
2.2 SUBMITTED EVIDENCE:
Test Aeency
Test Identifier
_Test Name/Report Date
American Test Lab of South
RT0624.05-14
TAS 112 07/03/14
Florida
Redland Technologies
.7161-03
Static Uplift Testing Dec. 1991
Appendix III
PA 102 & PA 102(A)
The Center for Applied
94-060B
Static Uplift Testing March, 1994
Engineering, Inc.
94-084
PA 101(Adhesive Set) May 1994
Redland Technologies
7161.03
(Mortar Set)
Wind Tunnel Testing Dec. 1991
Appendix II
PA 108 (Nail -On)
Redland Technologies
Letter Dated Aug. 1,1994 Wind Tunnel Testing Aug. 1994
Redland Technologies
P0631-01
PA 108 (Nail -On)
Wind 'Tunnel Testing July 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of Sept. 1993
The Center -for Applied
Project No. 307025
screw vs. smooth shank nails
Wind Driven Rain Oct. 1994
Engineering, Inc.
Test #MDC-76
PA 100
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier March 1999
Walker Engineering, Inc.
Calculations
25-7183 April 1999March 1995
25-7094 February 1996
25-7496 April 1996
MU MWMEcouN7Y
NOA No.: 15-0721.04
Expiration Date:12/08/20
Approval Date:11105115
Page 2 of 7
2.2 SUBMITTED EVIDENCE:
Test Aneney
Walker Engineering, Inc.
Walker Engineering, Inc.
Farabaugh Engineering and
Testing Inc.
Farabaugh Engineering and
Testing Inc.
Farabaugh Engineering and
Testing Inc.
3. LIMITATIONS
Test Identifier
Test Name/Report
Calculations
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
Calculations
Two Patty Adhesive Set System
T295.11
TAS-108
T306-11
TAS-108
T279-11
TAS-108
Date
December 1996
April 1999
10/65/11
10/04/11
09/23/11
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum 'undetlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
nttartMant: "Ou NOA No.:15-0721.04
Expiration Date:12/09/20
Approval Date:11105/15
PAge 3 of 7
4. INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Welght.(W) and Dimensions (I x w )
Tile Profile
Weight-W. (Ibf)
Length-1 (ft)
Wldth-w (ft)
Plantation Tile
111.8
1.375
1.08
Table 2: Aerodynamic Multipliers - �, (ft3)
The i 7. (ft3) ; (ft3)
Profile Batten Application Direct Deck Application
The
Table 3: Restoring Moments due to Gravity - M (ft-Ibf)
Profile 2":12" 3":12" 4":12" y,,.12" g��.12"
e_..--- •--- — -- -
.22 17.91
7:79 6.7b 7.67 6.61 7.52
6.26
than
C
•DADE COUNTY NOA No.:15-0721.04
Expiration Date;12/08/20
Approval Date: 11/05/15
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
For Nall -On Systems
Tile
Profile
Fastener Type
Direct Deck
(Min 16132"
plywood)
Direct Deck
(Min.19132"
plywood)
Battens
Plantation Tile
2-10d Ring Shank
30.9
38.1
17.2
Nails
1-10d Smooth or.
7.3
9.8
4.9
Screw Shank Nail
2-10d Smooth or,
14.0
18.8
7•4
Screw Shank Nails
1 #8. Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or
24.3
24.3
24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or
19.0
19.0
22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or
35.5
35.5
34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or
31.9
31.9
32.2
Screw Shank Nails
Eave Cli
2-10d Ring Shank
50.3
65.5
48.3
Nails'
1 Installation with a e
the headlap and fasteners are located a minimum of 2W from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Plantation Tile
Adhesive
31.33
2 See manufactures component approval for Installation requirements,
3 Flexible Products Company TiIsBond Average weights per patty 13.9 grams.
3M- 2-Component Foam Roof Tile Adhesive AH-160. Avers e.wel ht, era a tea, rams.
Table 6 Attachment Resistance Expressed as a Moment - Mr (ft-lbfF
For Single Patty Adhesive Set S stems
Tile Profile -
Tile Application
Minimum Attachment Resistance
Plantation Tile
31VI"' 2-Component Foam Roof Tile Adhesive AH-160
iAn9i=11
3Mm 2-Component Foam Roof Tile Adhesive AH-160
40.4s
4 Lame paddy placement of 45 nrams of 31VI" 2-Component Foam Roof Tile Adhesive AH-160
mediumpaddy Placement of 24 grams of 3M" 2-Component Foam Roof Tile Adhesive AH-160.
NOA No.:15-0721.04
Expiration Date:12/08/20
Approval Date: 11/05/15
Page 5 of 7
W
Table 7: Attachment Resistance Expressed as a Moment - Mr(ft-lbf)
for Mortar Set Systems
Tile Profile Tile Application Attachment
Resistance
Seespecific mortar manufacturer's Notice of Acceptance.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
�ENTESRA s=
PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.:15-0721.04
MIAM4D14DE COUNTY Expiration Date:12109/20
Approval Date:11105/15
Page 6 of 7
PROFILE DRAWING
PLANTATION FLAT CONCRETE TILE
END OF THIS ACCEPTANCE
MIAMI DAdE COUNTY
NOA No.:15.0721.04
Expiration Date: 12/08M
Approval Date: 11/05/15
Page 7 of 7