NOTICE OF ACCEPTANC
Interwrap, Inc.
32923 Mission Way
Mission, BC, Canada V2V-6E4
SCOPE:
'THESE PLANS AND ALL PROPOSED WORK
'ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY W" "AJOPWOARIA OO®RS,
OA
RESOURCES (RER)
LT
XTY r'OUNTV
'A AWII'''iViD FOR CAD
il`A;VIE`l�,'I;I} B
DATE � l /4/lam
OA NO
BE KEPT ON JOI
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.rniarnidade.Lyov/economv
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determi?ed by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium® UDL-3'0 / Titanium® PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30,
and UDL-MD (2 ply) / Titanium® PSU-30 Underlayment System
LABELING: Each unit shall bear a pe panent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 13-0730.01 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
C
ADE COUNTY
....
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILfIY OF THE
CONTRACTOR OF RECORD
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 1 of 7
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Category: Underlayment
Material: Polypropylene
TRADE NAMES OF PRODUCTS MANUFACTURED BY APPLICANT
TABLE 1
Product Dimensions Test Product
Specification Description
Titanium® UDL-25 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with one
PLUS Type I & II side coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Manufacturing
Location #1& #2
UDL-MD (2Ply system) 48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with a
Type I & II
chemical slip resistant and UV protected coating on
Manufacturing
both sides.
Location #2
Titanium® UDL-30 48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Type I & II
sides coated with UV protected and slip resistant
Manufacturing
polymer stabilized polypropylene on both sides.
Location #1& #2
Titanium® PSU-30 36" x 72' rolls
TAS 103
Unreinforced polymer modified bitumen material
adhered to the underside of a polymer -coated,
Manufacturing
synthetic woven sheet. The underside is backed
Location #3
with a release film.
MANUFACTURING LOCATIONS:
1. ML 1
2. ML3
3. ML4
NOA No.: 14-0603.19
MIAMI•DADE COUNTY Expiration Date: 01/26/22
Approval Date: 02/02/17
Page2,of'7 .
EVIDENCE SUBMITTED:
Test Agency
Intertek Testing Services
Trinity I ERD
Test Identifier
#3031783
3124826-01
3119607COQ-003 B
3130639COQ-002A
3124826MID-007
3146738COQ-003B
3146738COQ-003A
I35520.06.11
I35520.06.11
I38010.08.11
I35520.08.11-1
I3 5520.08.11
I44970.07.13-R1
Test Name/Renort
Date
TAS 104
02/19/03
ASTM E108
02/19/08
ICC-ES AC48
02/20/08
ASTM D226
02/20/08
ASTM E108
02/25/08
ASTM D 1876/ TAS 117
03/28/08
ASTM D226
04/22/08
TAS 103 / TAS 104
06/15/11
TAS 103 / TAS 104
06/15/11
ASTM D226
08/11/11
TAS 114
08/12/11
ASTM D2523 / D1781
08/17/11
ASTM D226, ASTM D1876
09/09/13
and TAS I I4(C)
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 3 of 7
APPROVED TITANIUM UNDERLAYMENT SYSTEM ASSEMBLIES:
Deck Type 1: Wood
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All General and System Limitations shall apply.
Base sheet: One or more plies of Titanium® UDL-25 PLUS or Titanium® UDL-30 applied with
minimum 4" horizontal laps land minimum 6" vertical laps and mechanically fastened as
noted below.
Note: Titanium® UDL-30 shall be inverted to provide a smooth bonding surface. Primer is
not required when Titanium UDL-30 is installed inverted (printed side facing down)
Fastening:
Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet.
Primer:
Metal/Tin caps shall be primed with ASTM D41 primer
Ply Sheet:
(Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum
6" vertical laps.
Membrane:
I
Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field,
using a heavy pressure roller under safe conditions to further secure the membrane.
Surfacing:
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
Note:
For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
i
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 4 of 7
Deck Type 1: Wood I
Deck Description: 19/32" or greater plywood or wood plank
System E (2): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All General and System Limitations shall apply.
Base sheet: One or more plies Titanium® UDL-30 applied with minimum 4 horizontal laps and
minimum 6" �%rtical laps and mechanically fastened as noted below.
Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field'of the sheet.
Primer: Titanium® UDL-30 shall be primed on the printed side with ASTM D41 primer prior to
placement of cap sheet.
Ply Sheet: (Optional) Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum
6" vertical laps.l,
Membrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave, using a heavy
pressure roller under safe conditions to further secure the membrane.
Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 5 of 7
Deck Type 1: Wood
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All General and System Limitations shall apply.
Base sheet: One or more plies of UDL-MD (2Ply system) applied with minimum 4" horizontal laps and
minimum 6" vertical laps and mechanically fastened as noted below.
Fastening: Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet.
Ply Sheet: (Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum
6" vertical laps.
Membrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field,
using a heavy pressure roller under safe conditions to further secure the membrane.
Surfacing: Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 6 of 7
BUILDING PERMIT
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
LIMITATIONS
1.
Fire classification is not part of
fire ratings of this product.
2.
This acceptance is for prepared
applicable building code.
3.
Titanium Synthetic Underlaym
irregularities. All nails in the dei
panels. Sweep the deck thoroug
4.
Titanium® UDL-25 PLUS / Ti
system) / Titanium® PSU-30 1
fastened roof tile, foam -on roof
5.
The standard maximum roof pits
/ Titanium® PSU-30, UDL-MD
for flat tiles and-6:12 on profile
shall be staged 2 base tiles per
maximum 7 tiles high on the sly
than the above limitations, the u
6. Titanium Synthetic Underlayme
7. Titanium® UDL-30 / Titaniuml
system) / Titanium® PSU-30 tw
longer than 90 days of applicatic
8. Titanium Synthetic Underlayme
approved under a specific Notic
Acceptance for listed approval c
9. Titanium Synthetic Underlayme
Titanium Synthetic Underlaymi
Titanium Synthetic Underlayme
(AHJ) or the Miami -Dade Cc
documentation is provided to de
10. All membranes or packaging sh
and the following statement: "]
Product Control Seal as shown 1:
E
this acceptance; refer to a current Approved Roofing Materials Directory for
applications. Minimum deck requirements shall be in compliance with
ats shall be applied to a smooth, clean and dry surface with deck free of
c shall be carefully checked for protruding heads. Re -fasten any loose decking
ly to remove any dust and debris prior to application.
mium® PSU-30, Titanium® UDL-30 / Titanium® PSU-30, UDL-MD (2PIy
vo-ply underlayment system, may be used in asphalt shingle, mechanically
le, metal roofing, wood shakes & shingles or slate roof assemblies.
1 for the Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium(& UDL-30
2Ply system) / Titanium(& PSU-30 two-ply underlayment system shall be 5:12
1 tiles with lugs. For flat tile applications at slopes exceeding 5:12, flat tiles
endicular to slope behind a mechanically attached batten or toe board with
)e atop base tiles (Total of stack not to exceed 9 tiles). At roof slopes greater
of loading battens or toe boards are required to load the roof tile.
is shall not be applied over an existing roof membrane as a recover system.
PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30, UDL-MD (2Ply
-ply underlayment system shall not be left exposed as a temporary roof for
:s are components used in roof system assemblies. Roof system assemblies are
of Acceptance. Refer to Prepared Roofing System Product Control Notice of
this product with specific prepared roofing products.
is may be used with any approved roof covering Notice of Acceptance listing
its as a component part of an assembly in the Notice of Acceptance. If
is are not listed, a request may be made to the Authority Having Jurisdiction
inty Product Control Department for approval provided that appropriate
.il compatibility of the products, wind uplift resistance, and fire testing results.
1 bear the imprint or identifiable marking of the manufacturer's name or logo
iami-Dade County Product Control Approved" or the Miami -Dade County
."CEPTANCE
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 7 of 7