HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFFlorida Building Code Online
Page 1 of 4
�n
UarR ROltfl+ gebUT DBPR.eBPRe11�l810tf8 "C6YiA'Ol'GBPR
BCISHome I Log In I User Registration Hot7oplcs I Submit Surcharge
FL #
Application Type
1
Code Version '
Application Status
f
Comments J
Archived
i
Product Manufacturer if
Address/Phone/Email J
Authorized
Technical
Quality Assurance Representative
Address/Phone/Email
Category �f
Subcategory
Compliance Method
Florida/Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Valldated By
1
Certificate of Independence
Referenced Standard and Year (of Standard)
r
I
Equivalence of Product Standards
Certified By
Sections from the Code
FL17022-R7
Revision
2017
Approved
08/18/2017v. date reapply 08/21/17
E-3
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Richard McKuhen
flvalldation@yahoo.com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
LOCKE BOWDEN
PE-49704
Keystone Certifications, Inc.
04/22/2024
Zachary R. Priest, P.E.
R Validation Checklist - Hardcopy Received
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr odf
Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
arm dtl.ast)x?naram=wGEVXOwtDgv2aBOvHnOOe6rMZ... 2/7/201 S
Florida Building Code Online
Page 2 of 4
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
FL #
Model, Number or
Name
Description
17022.1
1 - "5V Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf,
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions.
Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly In compliance'with the Installatio
method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of
FBC. Refer to
manufacturer's installation Instructions.
17022.2
2 - "5V Crimp" (R
5)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 11 FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odF
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for cont
Itions.Instali the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly In compliance with the installatioh
method listed In
ALUM ssr.odF
this report and applicable code sections of
FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's Installation instructions.
17022.3
3 - "1.5" Mechani
al Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
K17022 R7 II FL 17022.3, 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24oa ssr.ndf
Impact Resistant: No
Verined By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions
limitations of use. Install the assembly in compliance
the Installation method listed in this reportland
and
with
applicable
Evaluation Reports
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
seam 24oa ssr.odf
code sections of FBC. Refer to manufacturer's
Installation
Created by Independent Third Party: Yes
Instructions.
17022.4
4 - "1.5" Mechanical
Seam" (RS)
1.5" rib height, 16" wide, 0.0 2" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.ndf
Impact Resistant: No
Verined By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly In compliance with
Evaluation Reports
FL17022 RT AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.odf
Created by Independent Third Party: Yes
the installation method listed In this reportlland applicable
code sections of FBC. Refer to manufactureir's Installation
Instructions.
17022.5
5 - "1 In. Nall Strip" (115)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf
Verified By: Locke Bowden, P.E.'49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for cond
limitations of use. Install the assembly In compliance
tions and
with
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf
Created by Independent Third Party: Yes
httr)s://floridabuilding.org/Dr/Dr app dtl.asnx?I aram=wGEVXQwtDgv2aBODHi)QQe6rMZ... 2n/2018
Jib
Florida Building Code Online
G
Page 3 of 4
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's Installation
Instructions.
17022.E
6 - "i in. Nail Strip" (115)
1" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
/
plywood or Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No /
FL17022 R7 iT FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes'
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.odf
the Installation method Ilsted/in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Created. by Independent Third Party: Yes
instructions;
17022.7
"1.5 in. Nail Strip" (RS)
1.5" rib height, 19" wide, 26 gauge steel, standing seam
�-
roof panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
/
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: t+N/A/-Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of EBC. Refer to manufacturer's Installation
ins /
17022.8 /
8 -,"EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
trnt o Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf
Approved/for use outside HVHZ: Yes -
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 1,77022.8 EMAX Rib ssr.odf
limitations of use. Install the assembly In compliance with
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Instructions.
17022.9
PBR MAX" (115) 26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 11 FL 17022.9 PSR RIB SSr Ddf
Approved for use outside HVHZ: Yes
Verifled By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Refer to evaluation report for conditions
and FL17022 R7 AE FL 17n22.9,PBR RIB 55r Ddf
limitations
limitations of use. Install the assembly in compliance with
Created by independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC, Refer to manufacturers installation
Instructions.
Back Next
Contact Us " Z6DI gee Road T II ha
The State of Florida Is an AA/EEO employer. 2 Phone' 8 e 497 1924
CODYfInht OW-2013 UnderFloridaFlorida taw,small addresses are public records. If You d0 not Want your e-mail address r
etectronlc mail to this entity, Instead, contact the office b � �' tat m nt ;; Relund tat
Section have
one.
Th Florida Statutes, effective October 1, 2012�IIxnse y tradlHonal malt. If you have any q
they have one. The emaps provided may be used for Official communtca licensed underChepter455, F.S. mUSfp• aPublic -fe!6fdSMgUtst, do
supply a personal address, please piovlde the Department with an email addn with the licens - e50.497.139$, not send
resswmd,wn �•Howeveremalladdresses.are' 'Pursuant to
Chapter 455, Fs., please eatmade available to the public. To detemet lladdress r/
Product Approval Aceepbe.
MIMI
Credit r
Safe
SCCUrIt)'nt L•''1'ItlCS.
in"Z.orA/pr/pr app ddaspx?Para n=WGEVXQWtDgv2aBQpHpQQe6rMZ... 2/7/2018
* - 1
Palm City, Fl. 34990
Compliant with Florida Building Code 2017 (6" ed.)
Compliant with Florida Product Approval Rule # 611520-3
Compliant: Keystone Certifications
Product: EMAX Rib 29GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to attached to 15/32"
plywood or Woad Deck with fastehers. 36" Coverage (Max.)
Rib Height 3/4" 1
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(panel to deck): #10 x 1-1/2" (min.) Hex -Washer Head Wood Screw to penetrate
3/16" (min.) thru bottom of support.
Fastener 2 (panel sidelap, ): #14 x 7/8" (min.)I Hex -Washer Head Self -Drilling Screw to
penetrate 3/16"' (min.) thru bottom of suppo�t.
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec.
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
DESIGN PRESSURE*
I.86 PSF MAIN FIELD
-146 PSF PERIMETER
DECK THICKNESS (min.)
I 15/32" MIN
15/32" MIN
ROW SPACING (min.)
I 24"
12"
FASTENER SPACING ALONG ROW (max.)
SEE DETAILS
SEE DETAILS
PANEL WIDTH (max.)
I 36"
36"
PANEL SEAM (min.)
PANEL OVERLAPS
PANEL OVERLAPS
Reference Data: ARCHITECTURAL i TESTING, INC. TST ID#:1527
UL 580-06 & UL 1897-04 TEST REPORT F724 I.01-450-44 04/18/16
'DESIGN PRESSURE MARGIN OF SAFETY 2:1
EQUIVALENCY: UL1897-04 Is equivalent to TestStandard UL 1897-12.
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or disj� j4Vji09PfA jucts
under this evaluation. I ���� , BO y✓ ?""
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distrib `o'014u aU��1�tlQr Wloo,report. �
47
seal K
7 STATE OF ;
I y/ONACV� - :'
I
i
FL 17022.8 EMAX Rib k29GA Steel), 36" Wide Roof Panel - Details
I
i
Limitations:
i
1. Underlayment to be compliance with current Florida Bi
2. Minimum slope to be compliant with Florida Building C
3. Products are compliant for State of Florida product apl
4. Engineering analysis for "project specific approval by Ii
5. Fire classification is not part of this acceptance. Shear
6. Support framing in compliance w/FBC 2017 6'h ed., Ct
Loading.
7. This report does not imply warranty, installation, recon
PtYA0 , or
ing Code (FBC)2017 61h ed.
2017 6h' ed., and per with Manufacturer's installation reference.
gal per Rule 61 G20-3. Compliance Method: 1-D
I authorities w/jurisdiction is allowed by other registered engineers.
iphragm values are outside this report.
ter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
tr
product use outside of this report.
G
F1Dx 147Hex 1werH?ad NkOESaew
as�cr meting Croa aQoss pad vU
1 , Ard mexh"3! p3°el o�
o,M
View
VON arH YiSherF�,i15e6-D�IIcgSaeu
:p.»ed 1?ox. dog pvrJ Iv@`�
Rb-Px*l
Pavel
Panel Profile