Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFFlorida Building Code Online Page 1 of 4 �n UarR ROltfl+ gebUT DBPR.eBPRe11�l810tf8 "C6YiA'Ol'GBPR BCISHome I Log In I User Registration Hot7oplcs I Submit Surcharge FL # Application Type 1 Code Version ' Application Status f Comments J Archived i Product Manufacturer if Address/Phone/Email J Authorized Technical Quality Assurance Representative Address/Phone/Email Category �f Subcategory Compliance Method Florida/Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Valldated By 1 Certificate of Independence Referenced Standard and Year (of Standard) r I Equivalence of Product Standards Certified By Sections from the Code FL17022-R7 Revision 2017 Approved 08/18/2017v. date reapply 08/21/17 E-3 Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Richard McKuhen flvalldation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. R Validation Checklist - Hardcopy Received FL17022 R7 COI FL 17022.1 5 V CRIMP ssr odf Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 arm dtl.ast)x?naram=wGEVXOwtDgv2aBOvHnOOe6rMZ... 2/7/201 S Florida Building Code Online Page 2 of 4 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf, Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly In compliance'with the Installatio method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.2 2 - "5V Crimp" (R 5) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 11 FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odF Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for cont Itions.Instali the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly In compliance with the installatioh method listed In ALUM ssr.odF this report and applicable code sections of FBC. Refer to Created by Independent Third Party: Yes manufacturer's Installation instructions. 17022.3 3 - "1.5" Mechani al Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No K17022 R7 II FL 17022.3, 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24oa ssr.ndf Impact Resistant: No Verined By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions limitations of use. Install the assembly in compliance the Installation method listed in this reportland and with applicable Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL seam 24oa ssr.odf code sections of FBC. Refer to manufacturer's Installation Created by Independent Third Party: Yes Instructions. 17022.4 4 - "1.5" Mechanical Seam" (RS) 1.5" rib height, 16" wide, 0.0 2" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.ndf Impact Resistant: No Verined By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations of use. Install the assembly In compliance with Evaluation Reports FL17022 RT AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Created by Independent Third Party: Yes the installation method listed In this reportlland applicable code sections of FBC. Refer to manufactureir's Installation Instructions. 17022.5 5 - "1 In. Nall Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Verified By: Locke Bowden, P.E.'49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for cond limitations of use. Install the assembly In compliance tions and with FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf Created by Independent Third Party: Yes httr)s://floridabuilding.org/Dr/Dr app dtl.asnx?I aram=wGEVXQwtDgv2aBODHi)QQe6rMZ... 2n/2018 Jib Florida Building Code Online G Page 3 of 4 the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. 17022.E 6 - "i in. Nail Strip" (115) 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" / plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No / FL17022 R7 iT FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.ndf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes' Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf the Installation method Ilsted/in this report and applicable code sections of FBC. Refer to manufacturer's installation Created. by Independent Third Party: Yes instructions; 17022.7 "1.5 in. Nail Strip" (RS) 1.5" rib height, 19" wide, 26 gauge steel, standing seam �- roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No / FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: t+N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of EBC. Refer to manufacturer's Installation ins / 17022.8 / 8 -,"EMAX Rib" (115) 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. trnt o Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf Approved/for use outside HVHZ: Yes - Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 1,77022.8 EMAX Rib ssr.odf limitations of use. Install the assembly In compliance with Created by Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.9 PBR MAX" (115) 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 11 FL 17022.9 PSR RIB SSr Ddf Approved for use outside HVHZ: Yes Verifled By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Refer to evaluation report for conditions and FL17022 R7 AE FL 17n22.9,PBR RIB 55r Ddf limitations limitations of use. Install the assembly in compliance with Created by independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC, Refer to manufacturers installation Instructions. Back Next Contact Us " Z6DI gee Road T II ha The State of Florida Is an AA/EEO employer. 2 Phone' 8 e 497 1924 CODYfInht OW-2013 UnderFloridaFlorida taw,small addresses are public records. If You d0 not Want your e-mail address r etectronlc mail to this entity, Instead, contact the office b � �' tat m nt ;; Relund tat Section have one. Th Florida Statutes, effective October 1, 2012�IIxnse y tradlHonal malt. If you have any q they have one. The emaps provided may be used for Official communtca licensed underChepter455, F.S. mUSfp• aPublic -fe!6fdSMgUtst, do supply a personal address, please piovlde the Department with an email addn with the licens - e50.497.139$, not send resswmd,wn �•Howeveremalladdresses.are' 'Pursuant to Chapter 455, Fs., please eatmade available to the public. To detemet lladdress r/ Product Approval Aceepbe. MIMI Credit r Safe SCCUrIt)'nt L•''1'ItlCS. in"Z.orA/pr/pr app ddaspx?Para n=WGEVXQWtDgv2aBQpHpQQe6rMZ... 2/7/2018 * - 1 Palm City, Fl. 34990 Compliant with Florida Building Code 2017 (6" ed.) Compliant with Florida Product Approval Rule # 611520-3 Compliant: Keystone Certifications Product: EMAX Rib 29GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to attached to 15/32" plywood or Woad Deck with fastehers. 36" Coverage (Max.) Rib Height 3/4" 1 Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(panel to deck): #10 x 1-1/2" (min.) Hex -Washer Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Fastener 2 (panel sidelap, ): #14 x 7/8" (min.)I Hex -Washer Head Self -Drilling Screw to penetrate 3/16"' (min.) thru bottom of suppo�t. Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* I.86 PSF MAIN FIELD -146 PSF PERIMETER DECK THICKNESS (min.) I 15/32" MIN 15/32" MIN ROW SPACING (min.) I 24" 12" FASTENER SPACING ALONG ROW (max.) SEE DETAILS SEE DETAILS PANEL WIDTH (max.) I 36" 36" PANEL SEAM (min.) PANEL OVERLAPS PANEL OVERLAPS Reference Data: ARCHITECTURAL i TESTING, INC. TST ID#:1527 UL 580-06 & UL 1897-04 TEST REPORT F724 I.01-450-44 04/18/16 'DESIGN PRESSURE MARGIN OF SAFETY 2:1 EQUIVALENCY: UL1897-04 Is equivalent to TestStandard UL 1897-12. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or disj� j4Vji09PfA jucts under this evaluation. I ���� , BO y✓ ?"" Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distrib `o'014u aU��1�tlQr Wloo,report. � 47 seal K 7 STATE OF ; I y/ONACV� - :' I i FL 17022.8 EMAX Rib k29GA Steel), 36" Wide Roof Panel - Details I i Limitations: i 1. Underlayment to be compliance with current Florida Bi 2. Minimum slope to be compliant with Florida Building C 3. Products are compliant for State of Florida product apl 4. Engineering analysis for "project specific approval by Ii 5. Fire classification is not part of this acceptance. Shear 6. Support framing in compliance w/FBC 2017 6'h ed., Ct Loading. 7. This report does not imply warranty, installation, recon PtYA0 , or ing Code (FBC)2017 61h ed. 2017 6h' ed., and per with Manufacturer's installation reference. gal per Rule 61 G20-3. Compliance Method: 1-D I authorities w/jurisdiction is allowed by other registered engineers. iphragm values are outside this report. ter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural tr product use outside of this report. G F1Dx 147Hex 1werH?ad NkOESaew as�cr meting Croa aQoss pad vU 1 , Ard mexh"3! p3°el o� o,M View VON arH YiSherF�,i15e6-D�IIcgSaeu :p.»ed 1?ox. dog pvrJ Iv@`� Rb-Px*l Pavel Panel Profile