DEPARTMENT OF REGULATORY AND ECONOMIC
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
`7 LUCTV, CotNI T y RTTrr,n
BE PLANS AND ALL PROPOSES sJ��i°�.i� FOR coy slog
SUBJECT TO ANY CORREC110 EVIE "ED BY
UIRED BY FIELD INSPECTORS V
�� NECBS6AAY IN ORDER TO O_�.'-N AIND EMIT ST BE KEPT ON JOB
PLY WITH ALL APPLICA-80 00051, � i�' E SECTION
PRODUCT CONTROL SECTION
SOURCES (RER) 11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
XN"ED FASTENERS OR ATTAC>i BTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
This NOA is being issued under the applicable rule and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration dal
(in Miami -Dade County) and/or the AHJ (in areas c
product or material tested for quality assurance purl
manner, the manufacturer will incur the expense of
suspend the use of such product or material within t
if it is determined by Miami -Dade County Product i
requirements of the applicable building code.
This product is approved as described herein, and h
including the High Velocity Hurricane Zone of the
DESCRIPTION: Polyglass Polystick U
LABELING: Each unit shall bear a permanent label
statement: "Miami -Dade County Product Control Apl
stated below. The Miami -Dade County Product Control Section
ter than Miami -Dade County) reserve the right to have this
ses. If this product or material fails to perform in the accepted
Ich testing and the AHJ may immediately revoke, modify, or
;ir jurisdiction. RER reserves the right to revoke this acceptance,
)ntrol Section that this product or material fails to meet the
been designed to comply with the Florida Building Code
)rida Building Code.
the manufacturer's name or logo, city, state and following
i", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the exl iration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or p+ess. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of•this NOA shall be cause for termination and removal, of NOA.
ADVERTISEMENT: The NOA number preceded I by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be prc
shall be available for inspection at the job site at the req
This NOA renews and revises NOA No.] 5-0410.04 and
The submitted documentation was reviewed by Freddy
MIAMI•DADE COUNTY
ffi�lddl...•
to the user by the manufacturer or its distributors and
of the Building Official.
of pages 1 through 8.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
ILE COPYPage 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering
PRODUCTS DESCRIPTION:
Product
Dimensions
Polystick IR-Xe
65' x 3'33/8"
Manufacturing
Or 65' x 3'
Location #1 & #2
60 mils thick
Polystick Dual Pro
Manufacturing
Location #2
Polystick Tile Pro
Manufacturing
Location #2
Polystick TU Max
Manufacturing
Location #1 & #2
Polystick TU P
Manufacturing
Location #2
Polystick TU Plus
(Surface Printing)
Manufacturing
Location #1 & #2
Polystick MTS
Manufacturing
Location #2
Polystick MTS Plus
Manufacturing
Location #2
Elastoflex S6 G
Manufacturing
Location #2
Bitumen
Est Product
nation Description
D 1970 A fine granular/sand top surface self -adhering, APP
polymer modified, fiberglass reinforced, bituminous
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
61' x 3'33/8" TAS 103 and
A rubberized asphalt self -adhering, glass-fiber/polyester
60 mils thick ASTM D 1970
reinforced waterproofing membrane. Designed as a
metal roofing and roof tile underlayment.
6P x 3'33/8" TAS 103 and
A rubberized asphalt self -adhering, glass-fiber/polyester
60 mils thick ASTM D 1970
reinforced waterproofing membrane. Designed as a metal
roofing and roof tile underlayment.
65'8" x 3'3-3/8" TAS 103 and
A rubberized asphalt self -adhering, polyester reinforced
60 mils thick ASTM 1970
waterproofing membrane. Designed as a a roof tile
underlayment.
32'10" x 3'33/8" TAS 193 and
A rubberized asphalt waterproofing membrane, glass-
130 mils thick ASTM D 1970
fiber/polyester reinforced, with a granular surface
designed for use as a tile roof underlayment.
65' x 3'33/8" TAS 103 and
80 mils thick ASTM D 1970
65'8" x 3'33/8" TAS
60 mils thick
65'8" x 3'33/8" TAS
60 mils thick
32'10" x 3'3 %"
A rubberized asphalt self -adhering, glass-fiber/polyester
reinforced waterproofing membrane. Designed as a metal
roofing and roof tile underlayment.
03 A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
TAS 103, and Polyester reinforced, SBS modified bitumen membrane
ASTM D 16164 with a sanded back face and a granule top surface. For
use in roof tile underlayment systems.
I
�i NOA No.: 17-0614.22
MIAMI•DAD; COUNTY I Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
PI0870.0F09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.0�.11
TAS 103
03/02/11
P33370.0L4.11
ASTM D 1623
04/26/11
P36900.0�.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.1Q.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08I12-2
ASTM D 1623
08/07/12
P37590.07� 13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.19.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC1013 9.06.16-3
TAS 103 & TAS 110
06/27/16
PLYG-10130. 6.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-Q2-01
TAS 103
09/29/06
PUSA-055- 2-02
TAS 103
12/10/07
PUSA-089-
2-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798.& G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23138A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imppint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied
by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building
installation of this materials.
...
APPROVED
or applicable building code in order to properly evaluate the
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1:
Deck Description:
System Type E(1):
Anchor/Base Sheet:
Fastening:
Membrane:
Surfacing:
Deck Type 1:
Deck Description:
System Type E(2):
Anchor/Base Sheet:
Fastening:
Membrane:
Surfacing:
Deck Type 1:
Deck Description:
System Type E(3):
Anchor/Base Sheet:
Fastening:
Ply Sheet:
Membrane:
Surfacing:
Wood, non -insulated
Min. 19/32" plywood c
Anchor sheet mechanic
wood plank
}lly fastened to deck, membrane adhered
One or more plies of AS
Per FBC 1518.2 & 1518
base sheet only)
Polystick IR-Xe, Polysl
TU P, Polystick TU Plu
See General Limitations
Wood, non -insulated
Min. 19/32" plywood or
Anchor sheet mechanica
One or more plies of AS
Per FBC 1518.2 & 1518
base sheet only)
Elastoflex S6 G, hot as[
See General Limitations
Wood, non -insulated
Min. 19/32" plywood or w
Base sheet mechanically
One or more plies of ASTI
Per FBC 1518.2 & 1518.4
base sheet only)
Polystick MTS Plus, self -
vertical laps.
Polystick TU Plus, self -a(
See General Limitations B
vI D 226 Type II or ASTM D 2626.
Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
k Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
Polystick MTS or Polystick MTS Plus, self -adhered.
elow.
od plank
fastened to deck, membrane adhered
A D 226 Type II or ASTM D 2626.
Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
applied
id plank
tstened to deck, subsequent cap membrane self- adhered.
D 226 Type II or ASTM D 2626.
ails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
with minimum 3" horizontal laps and minimum 6"
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel �o the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane i applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane in o place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membra e shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane
6. Roll or broom the entire membrane surface
to lap areas.
7. Flash vent pipes, stacks, chimneys and pent
Notice of Acceptance.
8. All protrusions or drains shall be initially to
pressed in place and formed around the prol
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptar
2. Polystick Dual Pro, Polystick Tile Pro, Po
used in asphaltic shingles, wood shakes and
slate roof assemblies.
Polystick TU P may be used in all the previ,
Polystick IR-Xe may be used in all the prev
Polystick TU Max may be used in non-struc
Elastoflex S6 G may be used in roof tile sys
and roll from the center outward in both directions.
as to have full contact with the surface, giving special attention
s in compliance with Roof Assembly current Product Control
with a 6" piece of underlayment. The flashing tape shall be
on to ensure a tight fit. A second layer of Polystick shall be
TU Plus, Polystick MTS and Polystick MTS Plus may be
non-structural metal roofing, roof tile systems and quarry
assemblies listed except metal roofing.
assemblies listed except metal roofing and roof tile systems.
rl metal roofing and roof tile systems.
s only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polysti k Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystic} Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus lshall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystic)i Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osureiLimitations (Days)
MTS
IR-Xe
Elastotlex
S6 G
I TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
,180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality asslurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
MIAMI•DAD, COUNTY I Expiration Date: 09/13/21
Approval Date: 07/06/17
i Page 5 of 8
Rule 61 G20-3 of the Florida Administrative
8. In roof tile application, data for the attachml
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Pu
set and mechanically fastened roof tile appl
Polystick Dual Pro is limited to mechanic,
Polystick MTS and Polystick MTS Plus a
Section 9.
Polystick TU P may be used in mechanical
applications.
Code.
nt resistance of roof tiles shall be as set forth in the roof tile
TU Plus or Elastoflex S6 G may be used in both adhesive
� fastened roof tile applications.
limited to mechanically fastened with the limitations outlined in
fastened roof tile applications with the exception of mortar set tile
When loading roof tiles on roof tile underla�lment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
P
lystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MTS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
I
The above slope limitations can be exceededl only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Floridal Building Code requirements. When battens are required, they shall
be utilized during loading and installation of Itiles.
10. Care should be taken during the loading pro�edure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to P�lyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
Q
0
U)
N
f0
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product C
specific prepared roofing products. Polysti
Max, Polystick TU P, Polystick TU Plus,
used with any approved roof covering Notii
Polystick Tile Pro, Polystick TU Max, Pc
Plus or Elastoflex S6 G as a component p�
If Polystick IR-Xe, Polystick Dual Pro, I
TU Plus, Polystick MTS, Polystick MTS
Authority Having Jurisdiction (AHJ) or the
that appropriate documentation is provided
testing results.
POLYGLASS GENERAL APPLICA
itrol Notice of Acceptance for listed approval of this product with
IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
)lystick MTS, Polystick NITS Plus or Elastoflex S6 G may be,
of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
stick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
of an assembly in the Notice of Acceptance.
ystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
us or Elastoflex S6 G are not listed, a request may be made to the
fiami-Dade County Product Control Section for approval provided
detail compatibility of the products, wind uplift resistance, and fire
GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POIIYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local buildingl codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Seets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge lring shank type, applied with a minimum 1 V metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back hailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granuld end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed wl�en loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations # and #10.
6. Battens and/or Counter -battens, as required by �he the manufacturers NOA, must be used on all projects for
pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6 '/"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation% & before loading of roofing tiles is Forty -Eight (48) Hours.
S. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in eiter direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled'to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, cleat and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Associatign (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8