Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGFlorida Building Code Onlir�� Page 1 of 4 s$ BCIS Home ( Log In ( User Registration ( Hot Topics ( Submit V Product Approval ,jp r ,USER: Public User Product Approval Menu > Product or Application Search > Application FL # Application Type Code Version Application Status BY ie Comb/ Slats & Facts ; Publications ( FBC Staff ( BCIS Slte Map ( Links Search ST. LITCT 147OLr1'TY REVIERVED FOR CC DATE , 12//f v PLANS AND PERMIT OR NO LNSPECTION INUSION 'BE KEPT ON JOP BE 11.110E. Comments 08/18/2017v. date reapply 08/21/17 Archived ❑ THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive REQUIRED BY FIELD INSPECTORS THAT Palm City, FL 34990 MAY BE NECESSARY IN ORDER TO (772) 872-8034 Rvalidation@yahoo.com COMPLY WITH AUAPPUCABLE CODES, Authorized Signature Richard McKuhen Flvalidation@yahoo.com CONCFXED FASTENERS OR ATTACHMENTS Technical Representative Address/Phone/Email Richard McKuhen 2160 SW Poma Drive ARE THE RESPONSl61LITY OF THE Palm City, FL 34990 (772) 872-8034 CONTRACTOR OF RECORD rchard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer © Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who deve oped LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. ® Validation Checklist - Hardcopy Received Certificate of Independence I FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL1897 2012 I UL 580 2006 Equivalence of Product Standards Certified By I Sections from the Code FILE 6upy I htts://www.floridabuildin .or / r/ r a Idti.as x? aram=wGEVX wtD v2aB H .. 2/13/2018 P g g p P_ PP_ P P Q q QP PQQ• L Florida Building Code Onli* N Page 2 of 4 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products 1 Option D FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (R6) I 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the installation method listed in ALUM ssnodf this report and applicable code sections of FBC) Refer to Created by Independent Third Party: Yes manufacturer's installation instructions. 17022.3 3 - "1.5" Mechanical Seam" (115) 1 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use I Installation Instructions Approved for use in HVHZ: No I FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24aa ssr.odf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with FL17022 R7 AE FL 17022.3 1.5 MECHANICAL the installation method listed in this report and applicable seam 24ga ssr.pdf code sections of FBC. Refer to manufacturerls installation Created by Independent Third Party: Yes instructions. i 17022.4 4 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use I Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.odf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A I Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly inlcompliance with FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.5 5 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No ! Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other. Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf limitations of use. Install the assembly in compliance with Created by IndependentThird Party: Yes https://www.floridabuilding. org/prlpr_app_dtl. aspx?param=wGEVXQwtDgv2aBQpHpQQ... 2/ 13/2018 Florida Building Code Onl Page 3 of 4 the installation method listed in this report and applicable I code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 6 - "1 in. Nail Strip" (115) I 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" I plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A I Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 7 - "1.5 in. Nail Strip" (R5) I 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use i Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes I Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A I Other: Refer to evaluation report for conditions and Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.odf Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 8 - "EMAX Rib" (R5) I 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A I Evaluation Reports Other: Refer to evaluation report for conditions a9d FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pdf limitations of use. Install the assembly in compliance with Created by Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 9 - " PBR MAX" (R5) i 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use I Installation Instructions Approved for use in HVHZ: No I FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A I Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf limitations of use. Install the assembly in compliance with Created by Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions. I Back Next Contact Us :: 2601 BI The State of Florida is an AA/EEO employer. Copyright 2� Phone: 850-487-1824 :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emall address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with �n email address which can be made available to the public. To determine If you are a licensee under ,Chapter 455, F.S., please click here . Product Approval Accepts: =Ctedi Card ry i i I https://www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQ... 2/ 13/2018 Compliant with Florida Building Code 2017 (61 ed.) Compliant with Florida Product Approval Rule 61.G20-3 Compliant: Keystone Certifications Product: I" Nailstrip 26GA Steel Roof Panel FI Yield strength: 50 ksi min.; Attached Wood Deck w/ 0.42 specific gravity Rib Height 1" - Corrosion Resistant Compliant: FBC Sec.150 Fastener 1: #10 x 1" (min.)_ Pancake Head Woc bottom of support. I Adhesive/Sealant : Bostik 9151 Chem -Chalk a 3/16" continuous bead application along base 2160 SW Poma Drive Palm City, FL 34990 Sec.1507.4.2 i min.15/3r plywood or 'th 16" Coverage (Max.) .4.3 Screw to penetrate 3/16" (min.) thru ne component, polyurethane adhesive with of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING _ 6" O.C. 1 6" O.C. SEAM ADHESIVE ____-.__ ____----_.__-- _ Not required _ _ 3/16" continuous bead _ _(see details) Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 I EQUIVALENCY: UL1897-04 is equivalent to Test Standard ULI897--12. *Design Pressure margin of safe 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial h eMit6n q9V company manufacturing or distributing products under this evaluation. ��• ° Locke Bowden, P.E. is not owned, operated, or controllee�' �eh�y��lmgj&, dtanjlpdurer, or distributing products under this report. • seal I STATE OF ••� °0�� S'ONACE ,. h Limitations: 1. Underiayment to be compliance with current Florida Building Co 2. Minimum slope to be compliant with Florida Building Code 2017 3. Products are compliant for State of Florida product approval per 4. Engineering analysis for "project specific approval by local authc 5. Fire classification is not part of this acceptance. Shear diaphragr 6. Support framing in compliance w/FBC 2017 6°i ed., Chapter 22 Loading. 7. This report does not imply warranty, installation, recommended FL 17022.5 1.0 Nail Strip (26GA (FBC)2017 6"'ed.. ed., and per with Manufacturer's installation reference. fle 61-G20-3. Compliance Method:1-D ss wlurisdiction is allowed by other registered engineers. alues are outside this report. Steel, Chapter 23 for Wood and Chapter 16 for Structural use outside of this report. 16" Wide Roof Panel - Details s� Profile 341 Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock For NEI IOD 2: Apply 311V Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1" Mn. per Table "A" Pancake Head Wood Screw i ('typical Fastening Pattern Across Width) I I FL 17022.5 1.0 Nail Strip (26GA 1" Nail Strip Roof Panel Deck- - 15/32'or greater Plywood, or - Wood plank 16"Wide Roof Panel - Details #10 X 1" Min. Iper Table "A" Pancake Head Wood Screw View Seam Adhesive Application: For Method 2 Apply 3/16" Bead Bosfik 915Tm Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A')