HomeMy WebLinkAboutGAS PIPING SCHEMATICSCANNED BY & Ldde ccun,h/ BOARD OF COUNTY COMMISSIONERS [A2] [L4] TANK L1 L3 SIZE 54'0 L2] GAS PIPING SCHEMATIC 1.6] [A4] L1 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division [A6] [A1] [A3]; [AS]a 0; TANK SIZE: �J� I GALS. APPLICANCE — TYPE/SIZE Al GG-W rcf-.Pe 1 o r- I 33)1 00 Z BTU A2 BTU A3 BTU A4 BTU A5 BTU A6 BTU PIPING LENGTH & SIZE ' L1 a7V FT. INCH DIA. L2 FT. INCH DIA. L3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. 1-10 FT. INCH DIA. 1-11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE — TABLE 402 I' —)) ST. LUCIE COUNTY BUILDING QIVISION REVI 192 FOR C,F,lMPLI E REVIEWED BY DATE MUST S15 Kr -PT. ON 4011 OR NO JN1PftPgTIQH Wlhb De" MAI c> Website: www.stlucieco.aov 2300 Virginia Avenue - Fort Pierce. FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 Como Oil and Propane 1701 Commerce Avenue Vero Beach, FL K960 U N ?a` t 4PNCj%4,t�RE6 3:50 10 a Wrt.% 2''6 �� G� GROUND LEVEL 1/4" GALVANIZED VINYL COATED 500 GAL. WIRE ROPE W/ CABLE CLAMP, /' (2 REQUIRED \\ \\ \\ LP GAS \;, ) V TANK 5/8 x 48 TRAILER ANCHOR WITH 6" H"14 REQUIRED) RECEIVED ��-1z- z-,_/1-�� FEB 2 8 2018 GROUND LEVEL�e 5. u \/ 1/4" GALVANIZED VINY� / COATED WIRE ROPE \/ / 2 REQUIRED \ \ 500 GAL. LP GAS 5/0" x 48" TRAILER ANCHOR /\ \ TANK WITH 6" HELIX, 4 REQUIRED \/\/\/\/\/\/•aY� 4`J �y o A't+ m p'tm 9AI� 3oy%ye \\ \ . 3m a \ \ \ \ \/ENGINEERS SEAL SHOULD BE BLUE IN COLOR; fFONOT \\ \\ \ \\ \ CONTACT ENGINEER TO VERIFY SEAL IS AUTHENTIC°a°0n PROJECT: COMO OIL:. Vera Beach, Florida SHEET 1 OF 1 DRAWN BY: JL FL PE # 68366 Af ENGINEERING DESIGNED BY: JK PROJECT NO.: 180184 AND TES - I * qrAl P. mnmgz DATE: 01/1812018 owitt Quality Steel Corporation AGDUG Propane Wanks I . nr,vrl- r%1 ininn 1w1nrr_on1 [Bin /Ar'/1 Ira1 1LFS9ZFI r)IAAFI\ISIr)I\IS AND SPFCIPICATIONS WATERI IWAPACITY DIAMETER (OD) • HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG" SPACING WEIGHT (Ibs.) **QUANTITY FULL LOAD PER STACK *120 wg, 24"' Ellip. 5'-8" 3' 1'-� 1/2" 2'-101/2" 260 108196 16 1 12 *250 wg. 30" Hemi, 7',10" 3'-8" 1'-5'' 4'-11" 480 54 9 *320 wg. 30" Hemi, 9'-7" 3'48" �'- " 5' 620 45 9 500 wg. 37 1/2" Hemi, 10' 4'-2" 1'- " 5' 950 37 130 8 1 6 1000 wg, 4111 Hemi, 16' 4'-5" 11'-9 1/2" 1,800 17115 6 15 1450 wg, 46 1/2" Ellip. 17'�4" 4'-11" 1'-:9" 11'-7" 2,650 12 4 19' 0 wg. 46 1/2" Ellip. 23'-11" 4'-11" 1' 9" 16' 3,5z0 8 4 Dlmjnslons and speeiflcations shown pre approximate. Individual vessels may vary. " Leg spacing +/. 2", Lag Widths and spacing may vary basgd on Mfg. location. Check With your, salesperson for details, 1.20, 250,320 wg. stardard tanks no holes In legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes fib" on center. 1450 wg. end up as shown above. Full load and stpglS quantities vary by shipping location. Check with your salesperson for details. General Specifications i - Conforms to the latest edition of ASM.E Rules for Construction, of Pressure Vessels, Section Vill, Division 1, Complies with NFPA 58. t - - Rated at 250 psig from -20- F to 125° F. All vessels registered with National Board. I fTwo service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/U.G dome. Option 2: Aboveground option, coated with either pLder coated TOIC polyester finish or liquid i applied epoxy primer coat followed by urethane. top coat, supplied with steel AG/U(3 dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Como Oil and Propanee���.G' 1701 Commerce Avenue �7 Vero Beach, FL 32960os�t- 1 Inriarprl lanuary 14. 2015 } Exarpple 3 Determine the sizes of piping or tubing required for the 2 PSI LP -Gas installation shown. Total first stage piping length = 26 feet; first stage regulator setting is 10psig (use Table 1 or 2 @ 30 feet) Total 2 PSI Piping Length = 19 ft. (use Table 4 @ 20 ft. or Table S @ 20 ft.) From as to a, demand= 338,000 BTU use 318" CSST or 1/2" copper tubing or 1/2" pipe From Regulator a to each appliance: From a to b, demand= 65,000 BTU; length = 25 ft. (Table 5), yse 1/2" CSST From a to c, demand= 200,000 BTU; length = 30 ft. (Table 5) use 1" CSST From a to d, demand= 38,000 BTU; length = 21 V (Table 5) use 3/8" CSST use 25 ft. column Furnace From a to e, demand= 35,000 BTU; length = 40 ft. (Table 5) Range 55,000 200,000 use 1/2' CSST First Stage; �c r Regulator i 26 30Water Feet Fig Feet� b 25 Feet 21 Heater F38,000 a Feet Feet d :. as / 12 2 PSI Second Inches 40 Stage Regulator Line Pressure Feet Regulator Clothes l I' Dryer 35,000 e Table 1 -First Stage Tubing or Pipe Sizing* 10 PSIG Inlet with a 1 PSIG Pressure Drop (Between First and Second Stage Regulators) n n....:..................tti. ,.a n;ne nr f„1.;. i., th--nric of RTI 111hr of undiluted LP -Gases (Propane) (Based on 1:50 Specific Gravity Gas) Size of Pipe or Copper Tubing, Inches Copper 10 20 30 40 50 Length of Pipe or Tubing, in Feet* 60 70' 80 90 100 125 150 175 200 250 300 350 400 Tubing '%" 513 352 283 1 242 215 '194 179 1 166 1 156 1 147 1 131 118 109 1 101 90 81 75 70 (b.D.) t/z° 1,060 727 584 500 443 401 369 343 322 304 270 244 225 209 185 168 155 144 2,150 1,480 1,190 1,020 901 816 751 699 655 E 549 497 457 426 377 342 314 292 /3,760 2,580 2,080 1,780 1,570 1,430 1,310 1,220 1,150 1 959 869 799 744 659 597 549 511 Pipe Size '/e° 5,330 3,670 2,940 2,520 2,230 2,020 . 1,860 1,730 1,630 1,540 1360 1230 1130 1,060 935 847 779 725 �t/z" 3,320 2,280 1,830 1,570 1,390 1,260 1,160 1,080 1,010 956 848 768 706 657 582 528 486 452 3/" 6,950 4,780 3,840 3,280 2,910 2,640 2,430 2,260 2,120 2.000 1,770 1,610 1,480 1,370 1,220 1,100 1,020 945 1° 13,100 9,000 7,220 6,180 5,480 4,970 4,570 4,250 3,990 3,770 3,340 3,020 2,780 2,590 2,290 2,080 1,910 1,780 1'/4" 26,900 18,500 .14,800 12,700 11,300 .10,200 9,380 8,730 8,190 7,730 6,850 6,210 5,710 5,320 4,710 4,270 3,930 3,650 1Y,' 40.300 27,700 22,200 1 19,000 16,900 1 15.300 14,100 ;13,100 12,300 11,600 1 10,300 9,300 8,560 7,960 7,060 6,400 5,880 5,470 2" 77,600 53,300 42.800 1 36,600 32,500 1 29,400 27,100 i25.200 1 23,600 22,300 1 19,800 17,900 16,500 15,300 13,600 12,300 11,300 10,500 *Notes: Total length of piping from outlet of first stage regulator to miet of secona stage regwator for to iii- ui ­1 -yo ,may ,a• , , , ��• �.•�n 1) To allow 2 PSIG pressure drop, multiply total gas demand by 0.707 and use capacities from table. 2) For different first stage pressures, multiply total gas demand by the following factor and use capacities from table. Example: 1,000,000 BTU load at 5 PSI: 1,000,000 (1.12)=1,120,000 BTU then use chart based on 1,120,000 BTU First Stage Pressure PSIG Multiply By Data Calculated per NFPA# 54 and NFPA# 58 20 0.844 15 0.912 5 1.120 Tabl4 2 - First Stage Polyethylene Plastic Tubing or Pipe Sizing' 10 PSIG Inlet with a 1 PSIG Pressure Drop (Between First and Second Stage Regulators) Maximum capacity of nolvethviene pipe or tubing in thousands of BTU/hr of undiluted LP -Gases (Propane) Based on 1.50 Specific Gravity Size of Plastic NPS Pipe SDR 10 20 30 40 50 60 70 80 �erjgth 901 of Pipe, 100 or Tubing 1 125 in 1501 FocV' 175 1 200 1 225 250 215 300 350 400 tAaT 7.00 762 653 578 524 482 448 421 397 352 319 294 273 256 242 230 219 202 188 y: 9.33 2,140 1,840 1,630 1,470 1,360 1,260 1,180 1,120 990 897 826 778 721 681 646 617 567 528 * 11.00 2,390 3,670 3,260 2,950 2,710 2,530 2,370 2,240 990 897 826 778 721 681 646 617 567 528 1 T 11.00 5,230 4,470 3,960 3,590 3,300W3.0702,880 2,720 2,410 2,190 2.010 1,870 1,760 1,660 1.580 1,500 1,380 1,290 1, 11.00 7,740 6,630 5,870 5,320 4,9004;270 4.040 3,580 3,240 2,980 2,780 2,600 2,460 2,340 2,230 2,050 1,910 1% 11.00 13,420 11,480 10,180 9,220 8,4807,400 6,990 6,200 5,620 5,170 4,810'4,510 4,260 4,050 3,860.0020,300 17,300 15,400 13,900 12,80011,200 10,600 9,360 8,480 7,800 7,260 6,810 643011.00' 36,400 31,200 27,600 25,000 23,0000.100 19,000 16,800 15,200 14,000 13,000 12,200 11,600 11,000 10,470 9,640 8,970 T = Tube Size First Stage Pressure PSIG Multiply By Data Calculated per NFPA# 54 and NFPA# 58 20 0.844 15 0.912 5 1.120 13 Man 100 Rego Dr. P.O. Box 247 Elon, NC 27244 USA www.regoproducts.�m Phone (336) 449-7707 Fax (336) 449-8594 I N