HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 5705 Oleander Ave
Builder Name: Treasure Coast General Contractors
Street: 5705 Oleander Ave
Permit Office: St Lucie
City, State, Zip: Fort Pierce , FL , 34982 SCANNED
Permit Number:
Owner: - Christine W Campbell S1'
Jurisdiction: . 611000
Design Location: FL, ST LUCIE CO_INTL �� Q ,lP /e(%`
1,n9.
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
Wall Types (1044.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.4 773.33 ftz
b. Frame - Wood, Adjacent
R=13.0 270.67 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms(Bedrms In Addition) 1(0)
d. N/A
R= ft2
!
10. Ceiling Types (728.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 728.00 ft2
6. Conditioned floor area above grade (ft2) 728
b. N/A
R= ft2
I
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(109.0 sqft.) Description Area j
a. Sup: Attic, Ret: Attic, AH: Garage
6 120
a. U-Factor: Sgl, U=0.32 69.00 ft2
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.32 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.17
a. Central Unit
17.0 SEER:16.00
c. U-Factor: WA ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
16.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.202 I
14. Hot water systems -
�
a. Electric
Cap: 40 gallons
8. Floor Types (728.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 728.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF
Glass/Floor Area: 0.150 Total Proposed Modified Loads: 26.23
PASS
Total Baseline Loads: 27.45
i
i
I hereby certify that the plans and specifications covered by
Review of the plans and
O�T'HE SrA?8
this calculation are in compliance th Florida r y
specifications covered by this
Code.
calculation indicates compliance
yrp'l s z .••••.�` .!+
with the Florida Energy Code.
�+ a+rrr-_ �� ••: =• .;.� - �� O
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
"
#
1 hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
�40�
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: 4/19//.p
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
�x.Y •. 1 ,, � rw 1, ,�.1 'VlY
1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
13iT7M1111:zrole-WeiVi
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
5705 Oleander Ave Bedrooms: 1
User Conditioned Area: 728
Christine W Campbell Total Stories: 1
1 Worst Case: No
Treasure Coast General Contr Rotate Angle: 0
St Lucie Cross Ventilation:
611000 Whole House Fan:
Single-family
Addition
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 5705 Oleander Ave
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34982
CLIMATE
v Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
728 7134.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
728 7134.4 Yes ; 1
1
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 108 ft 0
728 ftz
---- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Metal 789 ftz 0 ftz Light
0.6
No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 728 ftz
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
728 ft2 0.16 Wood
1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017
WALLS
Adjacent Space
Cavity Width Height Sheathing Framing Solar
Below
1
2
3
4
N
W
S
E
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Garage Frame - Wood Main
4 26 9
4 28 9
4 26 9
13 28 9
8 251.3 ft' 0 0.75
8 270.7 ft' 0 0.75
8 251.3 ftz 0 0.75
8 270.7 ftz 0 0.75
0
0
0
0
DOORS
#
Ornt Door Type Space
Storms
U-Value Width Height
Ft In Ft In
Area
1
2
N Insulated Main
E Insulated Main
None
None
.4 3 6 7 19.8 ftz
.4 2 8 9 8 25.8 ftz
WINDOWS
Orientation shown is the'entered, Proposed orientation.
V
#
Wall
Omt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1
2
3
4
5
N 1 Vinyl Low-E Single Yes
N 1 Vinyl Low-E Single Yes
W 2 Vinyl Low-E Single Yes
W 2 Vinyl Low-E Single Yes
S 3 Vinyl Low-E Single Yes
0.32 0.22 Y
0.32 , 0.22 Y
0.32 0.17 Y
0.32' 0.22 Y
0.32 0.22 Y
15.0 ftZ 2 ft 0 in 1 ft 0 in None
9.0 ftz 2 ft 0 in 1 ft 0 in None
40.0 ft2 2 ft 0 in 1 ft 0 in None
15.0 ftz 2 ft 0 in . 1 ft 0 in None
30.0 ftz 2 ft 0 in 1 ft 0 in None
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
952 ftz 952 ftz
96 ft
9.8 ft 1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000311
594.5 32.64 61.38 .2335 5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity Block
Ducts
1
Electric Strip Heat/Supplement None
COP:1
16 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/Supplemental for None
SEER: 16
17 kBtu/hr 510 cfm 0.75 1
sys#1
1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
HOT WATER SYSTEM
it System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.92 40 gal
40 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply —
— Return I
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 120 ft2
Attic
36.4 ft2 ' Default Leakage
Garage
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: None
Ceiling Fans:
i
Cooling[ ] Jan
Heatin[ Jan
Feb
HFeb
Mar
Mar
j
[
] Apr
]r
Jul
Jun ri
May ril
I May Jun Jul
AuSeP
rl Aug
Se
rl
WOct
Oct
Nov
Nov
Hx
Dec
HDec
Ventin I ] Jan
Feb
X Mar
[X]
r
May Jun Jul
Aug
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating(WD)
AM
68
68
68
68 68 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
Heating(WEH)
AM
68
68
68
68 68 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2017 -
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
5705 Oleander Ave; Fort Pierce, FL, 34982
1. New construction or existing
Addition
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0
773.33 ft2
b. Frame - Wood, Adjacent
R=13.0
270.67 ft2
3. Number of units, if multiple family
1
j c. N/A
R=
ft2
4. Number of Bedrooms
1(0)
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0
728.00 ft2
6. Conditioned floor area (ft2)
728
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows" Description
Area
11. Ducts
R ft2
a. U-Factor: Sgl, U=0.32
69.00 ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 120
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.32
40.00 ft2
SHGC: SHGC=0.17
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
17.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
16.0
COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.202
8. Floor Types
Insulation
Area
14. Hot water systems -
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0
728.00 ft2
a. Electric
EF: 0.92
b. N/A
R=
ft2
c. N/A
R=
ft2
b. Conservation features
None
15. Credits
CF
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL bisplay Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
010tE Sx```
COD WE
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGa6ge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2017 Envelope Leakage:, -_-,,I Report Performance
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING !CONSTRUCTION
Envelope Leakage Test Report
Performance Method
Project Name: 5705 Oleander Ave
Street: 5705 Oleander Ave
City, State, Zip: Fort Pierce , FL , 34982
Design Location: FL, ST LUCIE_CO_INTL
Cond. Floor Area:: 728 sq.ft.
Envelope Leakage Test Results
Regression Data:
C:
n:
Single or Multi Point Test Data
IZA
Builder Name: Treasure Coast General Contractors
Permit Office: St Lucie
Permit Number:
Jurisdiction: 611000
Cond. Volume: 7134 cu ft.
HOUSE PRESSURE
FLOW:
1
Pa
cfm
2
Pa
cfm
3
Pa
cfm
4
Pa
cfm
5
Pa
cfm
6
Pa
cfm
Leakage Characteristics
Required ACH(50) from
FORM R405-2017 :
Tested ACH(50) * :
*Tested leakage must be less than or equal to the
required ACH(50) shown on Form R405-2017 for
this building. If the tested ACH(50) is less than 3
the building must have a mechanical ventilation
system.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at 'a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved
third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing: i
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
1
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time o
I hereby certify that the above envelope leakage
performance results demonstrate compliance
with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
SIGNATURE:
PRINTED NAME:
DATE:
me lest, snau De ruuy open.
Testing shall be conducted by either
individuals as defined in Section
553.993(5) or (7), Florida Statutes or
individuals licensed as set forth in
Section 489.105(3)(f), (g), or (i) or an
approved third party. A written report of
the results of the test shall be signed
by the third party conducting the test
and provided to the code official.
I
BUILDING OFFICIAL:
DATE:
Q�►O� �1HS ,-J'-�A��O�,
1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1