Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 5705 Oleander Ave Builder Name: Treasure Coast General Contractors Street: 5705 Oleander Ave Permit Office: St Lucie City, State, Zip: Fort Pierce , FL , 34982 SCANNED Permit Number: Owner: - Christine W Campbell S1' Jurisdiction: . 611000 Design Location: FL, ST LUCIE CO_INTL �� Q ,lP /e(%` 1,n9. County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition Wall Types (1044.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.4 773.33 ftz b. Frame - Wood, Adjacent R=13.0 270.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(0) d. N/A R= ft2 ! 10. Ceiling Types (728.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 728.00 ft2 6. Conditioned floor area above grade (ft2) 728 b. N/A R= ft2 I c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(109.0 sqft.) Description Area j a. Sup: Attic, Ret: Attic, AH: Garage 6 120 a. U-Factor: Sgl, U=0.32 69.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.32 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.17 a. Central Unit 17.0 SEER:16.00 c. U-Factor: WA ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 16.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.202 I 14. Hot water systems - � a. Electric Cap: 40 gallons 8. Floor Types (728.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 728.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF Glass/Floor Area: 0.150 Total Proposed Modified Loads: 26.23 PASS Total Baseline Loads: 27.45 i i I hereby certify that the plans and specifications covered by Review of the plans and O�T'HE SrA?8 this calculation are in compliance th Florida r y specifications covered by this Code. calculation indicates compliance yrp'l s z .••••.�` .!+ with the Florida Energy Code. �+ a+rrr-_ �� ••: =• .;.� - �� O PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 " # 1 hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. �40� WE OWNER/AGENT: BUILDING OFFICIAL: DATE: 4/19//.p DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). �x.Y •. 1 ,, � rw 1, ,�.1 'VlY 1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 13iT7M1111:zrole-WeiVi PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 5705 Oleander Ave Bedrooms: 1 User Conditioned Area: 728 Christine W Campbell Total Stories: 1 1 Worst Case: No Treasure Coast General Contr Rotate Angle: 0 St Lucie Cross Ventilation: 611000 Whole House Fan: Single-family Addition Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5705 Oleander Ave County: St. Lucie City, State, Zip: Fort Pierce , FL, 34982 CLIMATE v Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 728 7134.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 728 7134.4 Yes ; 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 108 ft 0 728 ftz ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Metal 789 ftz 0 ftz Light 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 728 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 728 ft2 0.16 Wood 1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 2 3 4 N W S E Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Garage Frame - Wood Main 4 26 9 4 28 9 4 26 9 13 28 9 8 251.3 ft' 0 0.75 8 270.7 ft' 0 0.75 8 251.3 ftz 0 0.75 8 270.7 ftz 0 0.75 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 2 N Insulated Main E Insulated Main None None .4 3 6 7 19.8 ftz .4 2 8 9 8 25.8 ftz WINDOWS Orientation shown is the'entered, Proposed orientation. V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 N 1 Vinyl Low-E Single Yes N 1 Vinyl Low-E Single Yes W 2 Vinyl Low-E Single Yes W 2 Vinyl Low-E Single Yes S 3 Vinyl Low-E Single Yes 0.32 0.22 Y 0.32 , 0.22 Y 0.32 0.17 Y 0.32' 0.22 Y 0.32 0.22 Y 15.0 ftZ 2 ft 0 in 1 ft 0 in None 9.0 ftz 2 ft 0 in 1 ft 0 in None 40.0 ft2 2 ft 0 in 1 ft 0 in None 15.0 ftz 2 ft 0 in . 1 ft 0 in None 30.0 ftz 2 ft 0 in 1 ft 0 in None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 952 ftz 952 ftz 96 ft 9.8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000311 594.5 32.64 61.38 .2335 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplement None COP:1 16 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for None SEER: 16 17 kBtu/hr 510 cfm 0.75 1 sys#1 1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 HOT WATER SYSTEM it System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return I Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 120 ft2 Attic 36.4 ft2 ' Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: None Ceiling Fans: i Cooling[ ] Jan Heatin[ Jan Feb HFeb Mar Mar j [ ] Apr ]r Jul Jun ri May ril I May Jun Jul AuSeP rl Aug Se rl WOct Oct Nov Nov Hx Dec HDec Ventin I ] Jan Feb X Mar [X] r May Jun Jul Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 5705 Oleander Ave; Fort Pierce, FL, 34982 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 773.33 ft2 b. Frame - Wood, Adjacent R=13.0 270.67 ft2 3. Number of units, if multiple family 1 j c. N/A R= ft2 4. Number of Bedrooms 1(0) d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 728.00 ft2 6. Conditioned floor area (ft2) 728 b. N/A R= ft2 c. N/A R= ft2 7. Windows" Description Area 11. Ducts R ft2 a. U-Factor: Sgl, U=0.32 69.00 ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 120 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.32 40.00 ft2 SHGC: SHGC=0.17 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 17.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 16.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.202 8. Floor Types Insulation Area 14. Hot water systems - Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 728.00 ft2 a. Electric EF: 0.92 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits CF I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL bisplay Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: 010tE Sx``` COD WE "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGa6ge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2017 Envelope Leakage:, -_-,,I Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING !CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: 5705 Oleander Ave Street: 5705 Oleander Ave City, State, Zip: Fort Pierce , FL , 34982 Design Location: FL, ST LUCIE_CO_INTL Cond. Floor Area:: 728 sq.ft. Envelope Leakage Test Results Regression Data: C: n: Single or Multi Point Test Data IZA Builder Name: Treasure Coast General Contractors Permit Office: St Lucie Permit Number: Jurisdiction: 611000 Cond. Volume: 7134 cu ft. HOUSE PRESSURE FLOW: 1 Pa cfm 2 Pa cfm 3 Pa cfm 4 Pa cfm 5 Pa cfm 6 Pa cfm Leakage Characteristics Required ACH(50) from FORM R405-2017 : Tested ACH(50) * : *Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at 'a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: i 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 1 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time o I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. SIGNATURE: PRINTED NAME: DATE: me lest, snau De ruuy open. Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. I BUILDING OFFICIAL: DATE: Q�►O� �1HS ,-J'-�A��O�, 1/29/2018 8:10 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1