Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTob3u xammewooa vrlve Humble,TX 77338 Product Evaluation Report , MARK TRIPSON 26 Ga. 5V Crimp Roof Panel over Plywood Florida Product Approval # 13361.1 R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Mark Tripson 500012rh Street Vero Beach, Florida 32966 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1-4 c E Ns No. 449�W STATE OF ; -5 CO"Y�a� . Fi O R 1 �' • ?� ��• sew Drama. �i F • • . FCAA �� SS •��!' `� ,�FIL' �asrra i�� � O lq�L t a � 11 � ► ���� FL# 13361.1 R3 December 8, 2017 I Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: �SV Crimp Roof Panel, 26 Ga. Steel, 24" coverage, through fastened roof panel with fasteners in the panel rib over Min. 15/32" APA Plywood decking. Non - Structural Application. Panel Material/Standards: Material: Min. 26 Ga. Grade 50 Steel, ASTM A792 or ASTM A653 G90 conforming to�Florida Building Code 2017 Section 1507.4.3. Paint finish optional YieStrength: Min. 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thick'ess: 0.018" min. Width: 24" Coverage Rib Height: 3/8" major rib Panel Rollformer: Roll Former Corp Panel Fastener: #9-15 x '1-1/2" Woodgrip with long life head and sealing washing through the rib of the panel or approved equal, Y." minimum penetration through plywood. Corrosion, Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code 2017. Allowable Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure: 108.5 psf 156.5 psf Fastener Pattern (Through Panel Rib): 12"-12" 12"-12" Fastener Spacing: 12" O.C. 6" O.C. 'Design Pressure includes a Safety Factor = 2.0. ffllilll��I O 4 '�' • to No. 47 STATE OF ; Qc OR I _ � ssw ors -�i� 3` :; • ` ` (��' .: �', •.;�,}.: ��� ., !its% p •w' �� ��� F1L# 13361.1 R3 I December 8, 2017 Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ■ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ■ UL 1897-2012 - Uplift Test for Roof Covering Systems Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 376-0356T-06 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-2012 test standard. 1 Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. Underlayment: Per Florida Building Code 2017, Section 1507.1.1 and manufacturer's installation guidelines. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. ,`,,�ff�Irlf1lJ*jI STATE OF ; a s+n. orrbda. a� AL CI R I �� COAL 4# S mane G Iq 1 { f , FL# 13361.1 R3 December 8, 2017 Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. ' C E• E• jy D C E k No.449� STATE OF ; a N AL �u�na ,,� ass/ • ' �� ��,, 1r O 11111 s �%%% FL# 13361.1 R3 I December 8, 2017 ROLE FORMR CORP. HO WDEPENVENCE LANE CHWONT, VA 18114 sv 27-1/2' Rat Stook Material For 24" Coverage Note : All Radii 0.05 12NICIV99 26" - -Far- 24A - Coverag 12" -- 247 Coverac 7/16" Fixed Overlap Ribs 7/8° Adjustable Center Rib Adjustab!e Underlap Ribs rl • _ Ho.44923 -. • SW AL COA Bass 020" December 8, 2017 5-V CHIMP EXPOSED FASTENER SYSTEM FASTENER SPACING • � SEE LOAD TABLE 5V CRIMP PANEL /- WATERPRDO•F S / MEMBRANE MA78ilALCPf10N9 ASTM A 8�9 G-9i ASTR A :� FAMCATM OP ON STEEL 26 ` 7ECMtCAL MA -SUBSTRUCTURE Q1SWE CM 1 RVUZ FILL WSTIN CMCR SEIMCES = NATMI PIMCnCAUL7 ANY MATERI L, SHADE, a1 1THT'YW Ram, A-V f un GA� •LYi� M li6 �•W �.....� 49-18x 1-1!1VA30OZAC w/zr}a MEolo 11�t�a kotl%•10E IL��'• y�C E N S�`•':'n �L NO.44923 ; 7�STA o R lo.-O December 8, 2017