HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVALLAUG
S.,
�'j$PLICATIdN #:AP13.27674
STATE OF FLORIDA PERMIT #:56-SF-1821605
DEPARTMENT OF HEALTHermitting DOCUMENT #:F:11202673
ONSITE SEWAGE TREATMENT AND M==
CONSTRUCTION INSPECTION AND FINAAPPROVAL DATE PAID:02/08/Z018
L
•�oOp, FEE PAID:515.00
OCANNED RECEIPT #:567P[D-3478895
APPLICANT: Bryan Smith _ BY
AGENT: Treasure Coast General Contractors Nula maw
PROPERTY ADDRESS: 5705 Oleander Ave Fort Pierce, FL 34982
LOT: BLOCK:'
SUBDIVISION: ID# : 3409-114-0003-000-5
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
] 101]
TANK SIZE [1] 1090.00 [21 483.00
[
];
1271
SURFACE WATER
FT
] [02.]
TANK MATERIAL Polyethylene.
[
]
[281 •
DITCHES•
FT
] [031'
OUTLET DEVICE
[
]
[2+9]
PRIVATE WELLS:
FT
] [041
MULTI -CHAMBERED [ Y N ]
[
]
[.30]
PUBLIC WELLS
FT
] [051
OUTLET FILTER Polylok PL-68
[
]
[31]
IRRIGATION WELLS
FT
] [061,
LEGEND 1. 70-143-11DC4 2. 70-143-54SC4
[
]
[321
POTABLE WATER 75
FT
] [071
WATERTIGHT
[
]
[33.]
BUILDING FOUNDATIONS, 21
FT
] [08]
LEVEL.
[
]
(.34]
PROPERTY LINES 5
FT
] [09]
DEPTH TO LID
[
]
[35]
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
] [101
AREA [aj 362.24 [2] SOFT
[
]
[36]
DRAINFIELD COVER
] [11]
DISTRIBUTION BOX, HEADER x
[
]
[371
SHOULDERS
] [121
NUMBER OF DRAINLINES 1, 8.00 2.
[
.]
[.38]
SLOPES
] [131
DRAINLINE SEPARATION
[
]
[391
STABILIZATION 09/20/2019
] [141
DRAINLINE SLOPE
] [151
DEPTH OF COVER
ADDITIONAL.INFORMATION
1 [16]
ELEVATION [ ABOVE / BELOW ],BM 23'.00
[
]
[401
UNOBSTRUCTED; AREA
] [171
SYSTEM LOCATION
[
']
[41]
STORMWATER MUNOFF
] (181
DOSING PUMPS 1.00
[
]
[.42]
ALARMS
] [191
AGGREGATE SIZE
[.
]
[431
MAINTENANCE, AGREEMENT.
] [20]
AGGREGATE EXCESSIVE FINES'
[
]
[44]
BUILDING AREA
] [211,
AGGREGATE DEPTH
(
]
[45]
LOCATION CONFORMS, WITH SITE PLAN
[
]
[46]
FINAL SITE GRADING
FILL / EXCAVATION MATERIAL
[ 7
[471
CONTRACTOR
[ ]
[22] FILL AMOUNT
[ ]
[481
OTHER INFILTRATOR Qliick4 Plus EQ36'LP
[ )
[231 FILL TEXTURE
[ ]
[241 EXCAVATION DEPTH
ABANDONMENT
[ ]
[251 AREA REPLACED
[ ].
�[49]
TANK PUMPED
[ ]
[261 REPLACEMENT MATERIAL
[ ]_
[SO]
TANK CRUSHED 6• FILLED
Comments: Comments are on page 2..
CONSTRUCTION [ APPROVED � F-Oft St. LUCi2 CHD DATE.:: 08/13/201.8
DISAPPROVED ] ° Environmental Specialist
``
If,,rl--an J Ingram (ENVIRONMENTAL HEACTH).
FINAL SYSTEM [ APPROVED / DISAPPROVED]: r� -^^'a' /'mil St.. Lucie , CAD DATE: 0$/20/20.1$
Environmental Specialist l D na S M*(F.lorlda Department & Health
(Explanation of Violations' on following page)
DH 4016, 08109 (Obsbletes all previous editions which.may not be used)
Incorporated: 64E-6'.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1327674 E101821606
g" STATE OF FLORIDA.
,L f DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
APPLICATION 0-API 327.674
PERMIT # 56=SF '1'821605
DocuMENT. # F11,202673
DATE PAID 02/08/2418
515
FEE PAID:, —00
RECEIPT'#
The system is sized for 2 bedrooms with a maximum.occupancy of 4 persons (2 per bedroom), for a total estimated flow of 200
gpd. O'Grady's plumbing services, Grady Miller CFC1425688.. New ST, DT, 1/2 hp liberty pump and 8x4 long DF installed.
DT not of sufficient capacity. 150 gal DT capacity required for 200 gpd•system,:41 gaf DT installed: Contractor notifed onsite.
Contractor notified that a minimum 1:50 gal ;DT is required and that he must swap. the dosing tank out for one with sufficient
capacity and leave the legend -exposed' if he wished to have it inspected at final inspection: System. needs final inspection for DT
repiacement(legerid), pump; alarm, mound system, and'final site grading,.
DT inspected, New 483 tank installed_. Liberty 1/3.HP pump installed.
Needs final inspection for mound system, alarm check, and final Site grading.
Final inspection for mound system, alarm check,andfinal site grading'. satisfactory. No violations observed, Emailed,to contractor
and building department.
DH 4016, 06/0.9 (obsoletes all previous editions'which.may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3 .
EH Database v 1,0.1 AP1327674 E01821606.