Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRUSS
Lumber design .v.aIues7;Frq in accorda� . with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek® SCAMM , RE: 1337438-TC-5705 - li6v,, MITek USA, Inc. St Luc'ecau'"'�' 6904 Parke East Blvd. Site Information: Tampa, FL 33610-4115 Customer Info: TREASURE COAST GENERAL Project Name: SMITH Model: Lot/Block: Subdivision: Address: 5705 OLEANDER AVE City: FORT PIERCE State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 9.1 Wind Code: ASCE 7-10 Wind Speed: 160 mph Roof Load: 45.0 psf Floor Load: N/A psf This package includes 5 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T13135369 1 Al 1 2/4/18 12 I T13135370 I A2 1 2/4/18 1 13 1 T13135371 1 CJ1 1 2/4/18 14 1 T13135372 1 EJ3 1 2/4/18 15 1 T13135373 1 HJ3 1 2/4/18 SHOP DRAWING / SUBMITTAL RE APPROVED ❑ APPROVED AS NOTED El REVISE AND RESUBMIT ❑ REJECTED SUBMITTAL WAS REVIEWED FOR DESIGN CONFORMITYAND 'GENERAL CONFORMANCE TO CONTRACT DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT JOBSITE FOR TOLERANCE, CLEARANCE. QUANTITIES FABRICATION PROCE SES AND TECHNIQUES OF CONSTRUCTION, COORD) ATION OF HIS WORK WITH OTHER TRADES AND FULL CO P CEV�THCONTRACTDOCUMENTS ay: x Date: /t:,&o /LDI It, Architectonic Inc. Fort Pierce, FL 34950 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Albani, Thomas My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. -i i� 39380 STATE OF :�Q 0 R 1 O Q ;�,�. �...11, �O N A� ,��,��. Thomas A. Alban] PE No.39380 MITek USA, Inc. FL Cert 6634 6g04 Parke East Blvd. Tampa FL 33610 Date: Febtuajy 4,2018 Albani, Thomas 101, Job Truss T""` Type city Ply T13135369 1337438-TC-5705 Al,,der ' 1 1 Job Reference (optional) bullaers rlrst6ourc:, r-ort rrece, rL J4`940 v. i.... .+or . I . _. __ _ __.__.__ __ . _ ID:RcSDDjmAbSfW nUVpEgiKPsz?Sqw-jMjfRBZ46F1 OKBATLwp2?gC97nvi2SUMsh??5Bzovl o + 2-0-0 3-0-0 8-4-0 11-4-0 13-4-0 2-0-0 3.0-0 5-4.0 3-0-0 2-0-0 Special A.A Special Special Special LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 TCDL 15.0 Lumber DOL 1.25 BC 0.41 BCLL 0.0 ' Rep Stress Incr NO WB 0.06 BCDL 10.0 Code FBC2017/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=617/0-8-0, 5=617/0-8-0 Max Horz 2=35(LC 4) Max Uplift 2=-453(LC 4), 5= 453(LC 5) Max Grav 2=671(LC 43), 5=671(LC 42) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1266/653, 3-4=-1167/635, 4-5=-1266/653 BOT CHORD 2-8=-575/1181, 7-8= 590/1200, 5-7= 575/1182 Scale = 1:25.0 DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.07 7-8 >999 240 MT20 244/190 Vert(CT) -0.09 7-8 >999 180 Horz(CT) 0.02 5 n/a n/a Weight: 43 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc puffins. BOT CHORD Rigid ceiling directly applied or 7-6-4 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for/this design. 2) Wind: ASIDE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 453 lb uplift at joint 2 and 453 lb uplift at joint 5. 7) "NAILED" indicates 3-1 Od (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guldlines. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 170 Ib down and 50 lb up at 3-0-0, and 170 lb down and 50 Ito up at 8-4-0 on top chord, and 136 lb down and 107lb up at 3-0-0, and 136 lb down and 107 lb up at 8-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) in the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-4=-70, 4-6= 70, 2-5=-20 Concentrated Loads (lb) Vert: 8=32(F) 7=32(F) 11=-6(F) 12=-6(F) N m Im 6 Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 8904 Parke East Blvd. Tampa FL 33610 Date: February 4,2018 Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. f0/032015 BEFORE USE. �� Design valid for use only with MITek® connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems, seeANSi/TPIT Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314. Tampa, FL 33610 Job Truss T_,- - 71pe City Ply /' T13135370 1337438-TC-5705 A2 H. 1 1 Job Reference (optional) C..1 C..{. � n0.-nn 711iG D- 1 auiiuers rubLoouum, rVrl rime, rL JV.- 4-10-0 rSf W nUVoEa!KPsz?Saw-BZH1 fXaitY9HxKlfvdKHY21LCBHAnv_V4LIZddzov1 n -8-0 46 = 4x6 = 3 4 10 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) 0.07 5-7 >999 240 TCDL 15.0 Lumber DOL 1.25 BC 0.26 Vert(CT) 0.06 5-7 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.05 Horz(CT) -0.01 5 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=643/0-8-0, 5=643/0-8-0 Max Harz 2= 41(LC 9) Max Uplift 2= 388(LC 8), 5=-388(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3— 774/1083, 3-4=-673/1075, 4-5= 774/1083 BOT CHORD 2-8=-895/668, 7-8=-913/673, 5-7=-897/668 Scale = 1:25.0 PLATES GRIP MT20 244/190 Weight: 45 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 5-10-4 oc bracing. NOTES - I) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL--4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) -2-0-0 to 4-0-0, Interior(1) 4-0-0 to 4-10-0, Exterior(2) 4-10-0 to 6-6-0 zone; porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 2 and 388 lb uplift at joint 5. q ICh Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: February 4,2018 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M0.7473 rev. 101032015 BEFORE USE. ' Im Design valld for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing -MiT®k' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss T^-^c Type Qty Ply T13135371 1337438-TC-5705 CA G Jack 4 1 Job Reference (option 1 Builders FirstSource, Fort Piece, FL 34945 8. ro0 6 oep ' o �v `, u""" W . `_ `" - ' 'a- ' I D:RcSD DjmAbSf W nUVpEgiKPsz?Sqw-flq PStbKosH8ZUKSTLfW 5FHU aahJ W MXfJ?U694zovl m .2-0-0 1-0-0 2.0-0 1-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.00 2 >999 240 TCDL 15.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 2 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=-130/Mechanical, 2=348/0-8-0, 4=9/Mechanical Max Harz 2=53(LC 8) Max Uplift 3= 130(LC 1), 2=-248(LC 8) Max Grav 3=116(LC 8), 2=348(LC 1), 4=1 B(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib)' or less except when shown. Scale = 1:6.8 PLATES GRIP MT20 244/190 Weight: 6 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 130 Ib uplift at joint 3 and 248 lb uplift at joint 2. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cott 6634 6904 Parke East Blvd. Tampa FL 33610 Date: February 4,2018 Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/032015 BEFORE USE. ' Design valid for use only with MITek® connectors. This design Is based only upon parameters shown. and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only, Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI t Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss T.,,-- Type / Oty PIY r T13135372 1337438-TC-5705 EJ3 J__ .ten 4 1 Job Reference (optional) .o-l.l11 7l1i G Donn 1 Builders FirstSource, Fort Piece, FL 34945 8.1 aC) s oeP ro cU 1 r IVII i ON irMUSLrIeS, Inc.tea. a I D: RcSD DjmAbSf W nUVpEgi KPsz?Sqw-flgPstbKesHBZU KsTLrW 5FH R_afpW MxfJ? U694zov1 in -2-0-0 3-0-0 2.0-0 3-0-0 Scale = 1:10.2 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.01 2-4 >999 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.17 Vert(CT) -0.01 2-4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix-P Weight: 12lb FT=20% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=18/Mechanical, 2=354/0-8-0, 4=26/Mechanical Max Horz 2=79(LC 8) Max Uplift 3=-23(LC 12), 2=-237(LC 8), 4= 23(LC 8) Max Grav 3=20(LC 22), 2=354(LC 1), 4=52(L"C 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. r BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone; porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1'.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 3, 237 lb uplift at joint 2 and 23 lb uplift at joint 4. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 8904 Parke East Blvd. Tampa FL 33810 Date: February 4,2018 ® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIF7473 rev. 10103,2015 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the appllcablIlty of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Addilional temporary and permanent bracing WNW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss T- -- Type Oty Ply T13135373 1337438-TC-5705 HJ3 I �tl Hip Girder 2 1 Job Reference o tional Builders FirstSourge, Fort Piece, FL 34945 a.i 3u s Sep i o za i r Mii r en uiuusu lea, ua:. oat — o oe� ID:RcSDDjmAbSfWnUVpEgiKPsz7Sqw-7xOo3DcyPAP7Bev212MIdTgaq_yzFpBoYtEghWzovil 2-9-15 4.2-3 2-9-15 4-2-3 2.83 F12 2 NAILED NAILED 3x4 = Scale = 1:13.7 m 0 4-2-3 4-2-3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) -0.06 2-4 >805 240 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.56 Vert(CT) 0.05 2-4 >879 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 17lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=40/Mechanical, 2=364/0-10-15, 4= 10/Mechanical Max Harz 2=79(LC 4) Max Uplift 3=-33(LC 8), 2— 333(LC 4), 4=-53(LC 19) Max Grav 3=40(LC 1), 2=437(LC 35), 4=93(LC 30) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; VUlt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 331b uplift at joint 3, 333 (b uplift at joint 2 and 53 lb uplift at joint 4. 6) "NAILED" Indicates 3-1 Od (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guidlines. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 2-4=-20 Concentrated Loads (lb) Vert: 5=168(F=84, B=84) Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 8904 Parke East Blvd. Tampa FL 33610 Date: February 4,2018 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111I1-7473 rev. 10/03J2015 BEFORE USE � Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTelc Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPIi Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-'h d' For 4 x 2 orientation, locate plates 0-1/0 from outside edge of truss. This symbol indicates the required direction of slots in connector plates. ' Plate location details available in MTek 20/20 software or upon request. PLATE SIZE The first,dimension is the plate 4 x 4 width measured -perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI , Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) I 2 3 TOP CHORDS r) C O U a- O JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ]CC -ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSIlTPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek@ All -Rights Reserved MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-brocing, is always required. See BCSI, 2. Truss bracing must be designed by on engineer. For wide truss spacing, Individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other Interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions Indicated are minimum plating requirements. 12. Lumber used shall be of the species and size -and In all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing Indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 16, Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer, 17, Install and load vertically unless Indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone Is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.