Re: 3528 Red Tailed Hawk Dr. Lot 7022
Port St. Lucia, FL 34952
In Care Of: Respe Spector
Pe it # 1803-0142
Our offce has been made aware that our plans were not followed entirely. I have addressed each
comment from you, that deviate from our plans.
• Roof paned overhang can be up to 12 inches.
• 2"x4" studs can be used instead of 2"x6" studs everywhere.
• Horizontal break in the sheathing is allowed at blocking location.
• The grade at the shed walls needs to be 4" below exterior sheathing per FRBC R318.7.3.
• Hurricane Ties SP1 and SP2 that were used are structurally equivalent to H2.5 called for
on the plans.
Should you have any questions regarding any of the enclosed, please do not hesitate to contact
our office at your earliest convenience.