HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW SINGLE HUNGi
� a
rti '
FLORIDA. DOPAPTMENT OF
Business r Professional Regulation{} Lucie
a*
BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Site Map Unks Search
Florida
p,� Product Approval
r D USER: Public User
s r,.C:.vJf�.l:Lan
Product Approval Menu > Product or Application Search > Application Lis[ > Application Detail
FL # FL10970-R7
Application Type Affirmation
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Klamath Falls, OR 97601
(800) 535-3936
fbci@jeld-wen.com
Jason Kantola
fbci@jeld-wen.com
JELD-WEN Corporate Customer Service
3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800) 535-3936
customerserviceagents@jeld-wen com
Windows
Single Hung
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 202
Year
1994
9 I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity OYes O No O N/A
Product Approval Method Method 1 Option A
L; C 0 P
ZMFIT?I
Date Submitted 07/10/2017
Date Validated 07/10/2017
Date Pending FBC Approval
Date Approved 07/15/2017
Summary of Products
FL #
Model, Number or Name
Description
10970.1
Builders Atlantic Aluminum
Side Load Single Hung (4100) 52.125" x 72" Insulated Glass
(1/8 in - 1/8 out Annealed) or Single Glaze (3/16 in
Annealed)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL10970 R7 C CAC NI011624-R1.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
01/31/2026
Design Pressure: +50/-50
Installation Instructions
Other:
FL10970 R7 II DP-
50 52.125x72 Installation Instructions.Ddf
Verified By: Hermes F. Norero, P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL10970 R7 AE PER3032.odf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
Wrol
Credit Card
Safe
4" MAX.
FROM
14 3/8' CORNERS
O.C. MAX.
12
5/B'
MAX.
X
N
5:
W
0
3
WINDOW WIDTH (506' MAX.) ---
TYPICAL ELEVATION WITH FASTENERS
General Notes:
C
Ox Tar a yr
•
1 1/4'
G .
MIN.
EMBEDMENT
�_�
V
v
MAX
SHIM
SPACE
IG
AU me
Ji
DOW CORNING
�• 1199 SILICONE
GLAZING DETAIL
TYPICAL VERTICAL
FRAME SECTI❑N
NDTEi Caulk between
unit and opening.
am. DOW CORNING
1199 SILICONE
oLAU .M
I
GLAZING DETAIL
n MAX
SHIM
�"
SPACE
Y
O—
4
:4
C
• The product shown herein is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/s' monolithic or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind bome debris
protection is required by local building code. 111111111 /
• Maximum sizes are buck / net sizes and do not include f60 g s!
This schedule addresses only the fasteners required to anchor the product to
achieve the rated design pressure and impact performance (where applicable) up
to the size limitations noted. It is not intended as a guide to the installation Z ; • �.�
process and does not address the sealing consideration that may arise in different; 7
wall conditions. For the complete installation procedure, see the instructionE * .
packaged with the window or go to www.jeld-wen.com/resourcesriinstallaflon. T T w
This drawing and its contents are confidential and are not to be reproduced or ?. '<`
copied in whole or in pad or used or disclosed to others except as authorized by
JELD-WEN, Inc.
MASONRY
(NCTL 210-3656-1A)
1 1/4' MIN. EMBEDMENT-F------- 1/4' MAX
SHIM
/j' SPACE,
Rel � v •• Q
nrsr a yr p a l
c
a•
d
TYPICAL H❑RIZ❑NTAL
FRAME SECTION
NOTEi Caulk between unit and opening.
Max
Fram
e
DP
IMPACT
Installation Notes:
1. Seal flange /window to substrate.
2. Use 3/s' Tapcon fasteners through frame with sufficient length to
penetrate a minimum of 1 1/4" into the concrete (Min. t'c = 3000 psi)
or masonry (Conforms to ASTM C90).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for
the project of installation. Digitally signed by Hermes F. Norero, P.E.
4. Fasteners are not required through the sill. Reason: I am approving this document
Date: 2013.10.2413:08:16-04'00'
`
Po
PROJECT ENGINEER:
DATE:
02/24/2010
3737 Lakeport Boulevard
Klamath Falls, OR 97601
(541) 882 - 3451
Tetzlaff
SCALE:JELDVEN
NTS
CQCKW BY:
TIRE:
�lv�
Builder's Aluminum (4100) Single Hung
Masonry Installation (52.125" x 72.00")
AwaRovEDBY:
`TiPRoJKr
Na.:
,�,o
IDENTIFIER No.
MY44099
PLANT NAME AND LOCATION:
Venice Window Division
CAD DWG. No.:
Bn41oo_NCTL21a365s-
REV:
01
SHEET
1 of 5
4" MAX.
FROM
14 3/8" 1 ORNERS
O.C. MAX.
12
O.C8"
MAX.
7
N
n
2
z
3
�- WINDOW WIDTH (5Zfi- MAX.)--�
TYPICAL ELEVATI❑N WITH FASTENERS
General Notes:
M
m¢ =T v4-
M
`L4' MAX
�
SHIM
I
SPACE
tam •R
iff
DOW CORNING
vv
1199 SILICONE
GLAZING DETAIL
TYPICAL VERTICAL
FRAME SECTI❑N
NOTE, Caulk between
unit and opening.
7 DOW CORNING
/ --
1199 SILICONE
aAU me
I
I GLAZING DETAIL
1/4' MAX
T
SHIN
//— SPACE
• The product shown herein is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/s' monolithic or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind borne debris
protection is required by local building code. 1 1 1 111
• Maximum sizes are buck / net sizes and do not include fr $t cIg s!
This schedule addresses only the fasteners required to anchor the product to `% •�•••
achieve the rated design pressure and impact performance (where applicable) up �Q •• , �;
to the size limitations noted. It is not intended as a guide to the installation
process and does not address the sealing consideration that may arise in different: 7
wall,. conditions. For the complete installation procedure, see the instructionE yk .
packaged with the window or go to www.ield-wen.com/resourcesfinstallaflon. 10 T T
This drawing and its contents are confidential and are not to be reproduced or
copied in whole or in part or used or disclosed to others except as authorized by �i91
JELD-WEN, Inc.
WOOD FRAME
(NCTL 210-3656-1A)
1/4' MAX
SHIM
SPACE
1 1/2' MIN.
TYPICAL H❑RIZ❑NTAL
FRAME SECTI❑N
NDTEi Caulk between unit and openng
Max
Fram
e
DP
IMPACT
Installation Notes:
1. Seal flange /window to substrate.
2. Use #10 PFH or greater fasteners through frame with sufficient length
to penetrate a minimum of 1 1/2" into the wood framing (Min. S.G. _
0.55).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for
the project of installation.
4. Fasteners are not required in the sill.
O WN BY:
Tetzlaff
CHiCI® BY:
APPROVED BY:
40RT/PROTECT No.:
IDENTIFIER No.
,o MY44099
3737 Lakeport Boulevard
02/24/2010
SCALE:NTS JELDVEN Klamath(
541) 882 93451
Builder's Aluminum (4100) Single Hung
Wood Frame Installation (52.125" x 72.00")
01 ISHEET 2 of 5
DATE:
Falls, OR 7601
AV MAX.
FROM
14.3/8' CORNERS
O.C. MAX.
13"
O.C.
MAX.
S
N
_Lt
s
S
,S
WINDOW WIDTH (546" MAX.) --►I
TYPICAL ELEVATI❑N WITH FASTENERS
General Notes: -
5
t0�
m 1=
�r yr
--03
1/4' MAX
SHIN
SPACE
I t� on
�99 CORNING
avr 11S
GLAZING DETAIL
TYPICAL VERTICAL
FRAME SECTION
NOTE- Caulk between
unit and opening.
3 uw DOV CORNING
1199 SILICONE
.
a fa."
I
•
GLAZING DETAIL
1/4' MAX
SHIN
SPACE
3
= .
• The product shown herein is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/s' monolithic or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind bome debris
protection is required by local building code. 1 � 111Y
• Maximum sizes are buck / net sizes and do not include f'ry��l!i� g s�
This schedule addresses only the fasteners required to anchor the product to %
achieve the rated design pressure and impact performance (where applicable) up �� �Q'•.••'•••• ••
to the size limitations noted. It is not intended as a guide to the installation
process and does not address the sealing consideration that may arise in different: 7
wall ,conditions. For the complete installation procedure, see the instructionE >k .
packaged with the window or go to www.'eld-wen.com/resourcesriinstallagon. ► '0 T T
This drawing and its contents are confidential and are not to be reproduced or , -
copied in whole or in part or used or disclosed to others except as authorized by I 1i,
JELD-WEN, Inc. mF
NAIL FIN
(NCTL 210-3656-1A)
1/4' MAX
SHIM
SPACE
TYPICAL H❑RIZONTAL
FRAME SECTION
NOTEi Caulk between unit and opening
Frame
sMax
DP
IMPACT
5z x 72°
+50/-50
NO
Installation Notes: -
1. Seal nail fin to substrate.
2. Use #8 PH or greater fasteners through nail fin with sufficient length to
penetrate a minimum of %" into the wood framing (Min. S.G. = 0.55).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for the
project of installation.
4. We recommend using Tegratite'" installation
(http://www.jeld-wen.com/newinstallationtechnologyn for weatherproofing.
5. Window includes a slip on aluminum 6063-T5 nail fin (typ. wall thickness
.050"). Nail Fin extends approximately 1.258" away from frame.
�j PROIECTENGINEER: DATE: 3737 Lakeport Boulevard
O -- 02/24/2010 tMAWN BY: JEL�EN Klamath Falls, OR 97601
TetZlaff SCAM:NTS (541) 882 - 3451
Gv: TITLE:
APPROVED BY: Builder's Aluminum (4100) Single Hung
`T/PROIELT No.: Nail Fin Installation (52.125" x 72.00")
IDENTIFIEit No. PLANT NAME AND LOCATION: CAD DWG. No.: REV: SHEET
#ae�,o MY44099 Venice Window Division BA4100_NCTL210.3656- A 02 3 Of 5
A" MAX.
FROM
14.3/8" i CORNERS
O.C. MAX.
01, 7"
MAX.
3
N
V
W
O
Z
3
WINDOW -WIDTH (006 _MAX.)—�
TYPICAL ELEVATI❑N WITH FASTENERS
--1.8 t MSTTMUD
,m, na wn ya.
I Thread
NDV ThroThro ugh
1
0.
stud
\-1/4• NAx
\ SHIN
SPANS
I Wn am
DOV CORNING
yr 1199 SD.ICD E
GAZING DETAIL
TYPICAL VERTICAL
FRAME SECTI❑N
NOTEi Caulk between
unit and opening.
aw DON CORNING
/ 1199 SD.ICONE
. I
• GLAMM DETAIL
I 1/4' NNf
/—SHOT SPACE
4
MR
STUD
General Notes:
• The product shown herein is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/s' monolithic or 1/8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind borne debris
protection is required by local building code. 1111111
�
• Maximum sizes are buck /net sizes and do not include f'ry��b� g s! 1
This schedule addresses only the fasteners required to anchor the product to
achieve the rated design pressure and impact performance (where applicable) up �� �Q'•.• \••• • ' :F,p
to the size limitations noted. It is not intended as a guide to the installation
process and does not address the sealing consideration that may arise in different: 7 __
wall. conditions. For the complete installation procedure, see the instructionE 7F .
packaged with the window or go to www.ield-wen.com/resources/installafion. T T
STEEL STUD
(NCTL 210-3656-1A)
3 Thread MIN.
Through Stud -.�-�-
18 ga. MIN. 1/4' SHIM
STEEL STUD -
SPACE MAX
NDN
MST 1/R'
1
TYPICAL HORIZ❑NTAL
FRAME SECTION
NOTE, Caulk between unit and opening.
Max Frame
DP
IMPACT
52 x 72°
+50/-50
NO
Installation Notes:
1. Seal flange / window to substrate.
2. Use #10 PFH sheet metal screws or greater through frame with
sufficient length to penetrate a minimum of three (3) threads beyond
metal substrate (Min. 18 Ga., Fy = 33 ksi).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for
the project of installation.
4. Fasteners are not required in the sill.
i/2010 3737 Lakeport Boulevard
JE1Dr'�ATEN Klamath Falls, OR 97601
NTS (541) 882 - 3451
IrsLTa¢o BY: TITLE:
,Wo„ED BY: Builder's Aluminum (4100) Single Hung
Steel Stud Installation (52.125" x 72.00")
This drawing and its contents are confidential and are not to be reproduced or ..-"'`&FLOW,
copied in whole or in part or used or disclosed to others except as authorized by �i���i �Ba�aa� �%�� IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG. No.: REV: SHEET
JELD-WEN, Inc. ���,�,�,5,a MY44099 Venice Window Division BA4100_NCTL210.365& A 01 4 of 511
414" MAX.
FROM
14 3/8" i ORNERS
O.C. MAX.
7-
O.C.
MAX•
i
t
N
x
t2
YI
x
Z
3
�-- WINDOW WIDTH-(52V MAX.)
TYPICAL ELEVATI❑N WITH FASTENERS
General Notes:
---18 go. MIN.
STEEL STUD
' v
Mae 1W ve 50.
$ HI Through
Stud
`v4' MAX
1
SHIM
SPACE
t
/rvr�
DOW CORNING
3/4• 11" SILICONE
GLAZING DETAIL TYPICAL VERTICAL
FRAME SECTI❑N
NOTE, Caulk between
unit and opening.
yu DOW CORNING
• 1199 SILICONE
. / 6AS am
• t
•
GLAZM DETAIL
1/4' MAX
SHIN
SPACE
OO—
10-HIM
�p
1
O
STUD
Noteg-
• The product shown herein is designed, tested and manufactured to
comply with the wind load criteria of the adopted International Building
Code (IBC), the International Residential Code (IRC), the Florida Building
Code including the "High Velocity Hurricane Zone" (HVHZ) and the
industry standard requirements for the stated conditions.
• All glazing shall conform to ASTM E1300.
• Minimum nominal glazing: 3/16' monolithic or 1 /8" insulated.
• Installation methods may be interchanged within the same opening.
• An impact protective system is required where wind bome debris
protection is required by local building code. t t 1 t1W
• Maximum sizes are buck / net sizes and do not include f'rim' g 5'. �i,
This schedule addresses only the fasteners required to anchor the product to
achieve the rated design pressure and impact performance (where applicable) up��'•.•''••• • • ' C
to the size limitations noted. It is not intended as a guide to the installation\.�
process and does not address the sealing consideration that may arise in different; 7 .
wall conditions. For the complete installation procedure, see the instructionE 7k .
packaged with the window or go to www.geld-wen.com/resourcesfinstallation. =1 -0 T T
This drawing and its contents are confidential and are not to be reproduced orT%P,
,
copied in whole or in part or used or disclosed to others except as authorized by
3 Thread MIN.
Through Stud
STEEL STUD NAIL FIN
(NCTL 210-3656-1A)
1/4' SHIM
SPACE MAX
TYPICAL H❑RIZ❑NTAL
FRAME SECTI❑N
NOTE, Caulk between unit and opening
�l
Max Frarne
DP
IMPACT
52 x 72"
+50/-50
ND
1. Seal nail fin to substrate.
2. Use #10 sheet metal screw or greater fasteners through the frame with
sufficient length to penetrate a minimum of three (3) threads beyond
metal substrate (Min. 18 Ga., Fy = 33 ksi).
3. Host structure (wood buck, stud framing and opening) to be designed
and anchored to properly transfer all loads to the structure. The host
structure is the responsibility of the architect or engineer of record for the
project of installation.
4. Fasteners are not required though the sill.
5. Window includes a slip on aluminum 6063-T5 nail fin (typ. wall thickness
.050"). Nail Fin extends approximately 1.258" away from frame.
:l.l Cnnlrveen: UAIe: 3737 Lakeport Boulevard
02/25/2010
JELDWN Klamath Falls, OR 97601
TetSCALE:zlaff NTS (541) 882 - 3451
uEo BY. TmF:
A�aRovEDev: Builder's Aluminum (4100) Single Hung
Steel Stud with Nail Fin Installation (52.125" x 72.00")
1pRT/PROTECT Na,
IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG. No.: RIVV: 0
1 SHEET 5 of 5
S,q MY44099 Venice Window Division BA4100_NCTL210.3656- A
JELD-WEN, Inc. I mG