HomeMy WebLinkAboutENGINEERING1A, .. ~ 1 General Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4, ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO.67 LESS THAN 3/4". AIR ENTRAINING +/- 1 % - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A M1NIMUIvI OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: 1. CONCRETE MASONRY UNITS (MU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE OF TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8", 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'4" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 6t1j EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN # 10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1 "X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #10X 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 6th EDITION (CHAPTERS 16,20 & 23). F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. I. TYP --TYPICAL 2. SIM -- SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4. CONT -- CONTINUOUS 5. VIF -- VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: I. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 6. PLEASE NOTE: 2x2 (tyP) DIAGONAL BRACING SHALL BE 2"X2"X0.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. 7. ALL ALUMINUM SCREENED ENCLOSURES SHALL BE DESIGNED SPECIFICALLY FOR THE APPLICATION STATED IN RULE 61G20-1-002: TO REMOVE SCREEN PANELS IN THE EVENT OF FORECAST WINDS THAT EXCEED 75 MPH. LABELS SHALL BE PLACED ON CHAIR RAIL MEMBERS ON ALL SCREEN WALLS IN A LOCATION THAT CAN BE EASILY SEEN AND FOR ALL PANELS ABOVE THE DESIGNED CHAIR RAIL ON ALL SCREEN WALLS SHALL BE CUT AS PRESCRIBED IN THE RULE AND THE CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS STATED IN RULE 61G20-1,002 AND SECTION 19 LAWS OF FLORIDA, 553.76, 553.77., ONLY APPLIES IF SHOWN ON PAGE S-2 DRAWING PAGE. SCANNED St Lucie Cain � CUN 'LED FASTENERS ORA IACIii HTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORO DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 150 MPH NOMINAL DESIGN WIND SPEED Vasd: 116 MPH 2. RISK CATEGORY: 1 3. WIND EXPOSURE; C 4. WIND LOADS - - SCREEN ROOF: N/A SCREEN WALLS: 43 PSF SOLID ROOF (SCREEN WALL): 32 PSF COMPONENTS AND CLADDING LOAD: +19.00/-38.8 PSF 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 8. EXISTING SLAB AND OR FOOTING MEETS THE REQUIREMENTS TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: N/A 10. SOLIDROOF TYPE; 3"X48"10.032" ELITE EPS COMPOSITE PANEL ROOF 11b FOAM DENSITY, FLORIDA PRODUCT APPROVAL, FL 7561-114. ALUMINUM STRUCTURAL MEMBERS THESE PLANS AND ALL PROPOSED WORK HOLLOW SECTIONS ARE SUBJECT TO ANY CORRECTIONS 2 x 2:---------------------------------------2" x 2" x 0.044„ 2 x 3:---------------------------------------2" x 3" x 0.050" REQUIRED BY FIELD INSPECTORS THAT 2 x 4:---------------------------------------2„ x 4" x 0.050" MAY BE NECESSARY IN ORDER TO 2 x 5:---------------------------------------2" x 5" x 0.050" OWN WITO :6 ApPw6A96E CODES. OPEN BACK SECTIONS 1 x 2: ---------------------------------------- 1" x 2" x 0.040„ 1 x 3:----------------------------------------1" x 3" x 0.045" SNAP SECTIONS 2 x 2 Snap: ---------------------------------- 2" x 2" x 0.045„ 2 x 3 Snap:---------------------------------2" x 3" x 0.050" 2 x 4 Snap:--------------------------------- 2" x 4" x 0.045" SELF MATING (SMB 2 x 4 SMB:------------- •-------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:--=-------------------. 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB-------------------- 2" x 10" x 0.092" x 0.374" ST. LUC- COU\'•Y B4EKEPT'M N REVIEWED FOR COd REVI E 'ED BY DATE L PLANS AND P> 1I MT N , OR, NO IIgS ECTION'ii-11t BE Arltwr, /Bob_ ore p.•• oc E ps•.•Opp 07 O F �F �.00 * i 'A : StA7E OF Oil i • ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhil.ls, FL 33542 Ph#(813)788-5314 Fax# 1-(e66)824-7894 E-mail-efb@fbcplans.com Website-WWW.fbcplans,com C.O.A.429054 DATE: 2-20-2018 DRAWN : TLK REVISION: DATE: RO1 DATE:3-13-2018 RO 2 RO 3 RO 4 PROJECT ADDRESS: SCHURMANN 233 OLSON AVE FORT PIERCE, FL 34946 CONTRACTOR: K & S INDUSTRIES, INC. 0379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, ATTACH TO HOST FASCIA S-3 S-3 SMALL 1 " JOG FILLED WITH FLAT r2x4 S"MB BAR M m o 2; 3" COMPOSITE o I w N PANEL ROOF X o N N 2x4 SMB S-3 2X4 EDGE BM/1X2 36'-0" �2X4 E�GEM/1 C2 m m m m m X d 0 Q 0 d d It r7 N N CV x x x x X N N N N 2X2(typ) 2X2(typ) 2X2(typ) H S-3 S-3 (tyP) THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC S-3 A d ,. q ` 0 .•••%,%C EjNv F •. * No. 70667 • STATE OF •: , '•�OR10P•.•'��; i ••.., •• Goa �- i O PROP KE2SEAL 1 ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. X O FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering o Services, Inc. 1 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-Www, fb cplans. corn C.O.A.429054 DATE: 2-20-2016 DRAWN By; TLK REVISION: DATE: RO1 DATE: 3-13-2018 RO 2 RO 3 RO 4 PROJECT ADDRESS: SCHURMANN 233 OLSON AVE FORT PIERCE, FL 34946 CONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 12 . , t4-. ALUMINUM RISER PAN 3"SOLID (4) #10 SMS W/ 3/4" ROOF PANEL WASHERS PER 12" PANEL _-___-_-- # 10 X 4" SMS Detail C2 (4" NEOPRENE 3"SOLID ER 8" O.C. PER (—ROOF PANEL PANEL j 1" 2" OPEN BACK ADDED TO EDGE BEAM w/(2) #10 x1 Y2" SMS &TO EDGE BEAM w/#10XiiW I II SMS12 C/CIF TRIBUTARY BETWEEN POST I I I I EXCEEDS 6'-6" OR 150 MPH "C" II II SIDE VIEW EDGE BEAM ..0 2"X2"X3"X 0.62" ANGLE W/ (2) #12X 3/4" EA. LEG #10X4" SMS THRU -EDGE BEAM INTO 2"}C "X0.050"EDGE BEAM POST SCREW BOSS CONTINUOUS (SEE S-2 FOR SIZE) EDGE BEAM SPLICE 4)#10X4"-MIN. NTOSCREW BOSS -------- --- --- 2"X_"X0.050"UPRIGHT (SEE S-2 FOR SIZE) — 2"X2"X3"X 0.62" (4) #10X4" SMS THRU I I AN W/ (2) #12X EDGE BEAM INTO I I 3/4" I LEG POST SCREW BOSS EDGE BEAM SPLICE $ ROOF PANEL TO EDGE BEAM CONNECTION DETAIS $_3 SCALE:NTS OPTION #1 OPTION #2 (4)#10 x 1 Y2" SMS RECEIVING CHANNEL INTO SCREW OR ANGLE EA. SIDE (typ) BOSSES S(.0625" THICKNESS) 2"X2" OR 2"X3" (2) #10x 3/4" SMS PURLIN OR GIRT (typ) EA. LEG) (TOTAL 6 SCREWS R.C. (8) SCREWS ANGLE EA. CONNECTION) H PURLIN OR GIRT TO BEAM OR POST DETAIL $_3 SCALE: NTS HINGE LOCA (4) #10 X 3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) -3/8" 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE(TYP EACH SIDE) (SEE TABLE) ANCHORSPA - (MIN) (TYP)(SEE TAB Column Size 3/8" 0 Concrete Screw Anchor B Min. Spa 2X3 2x4 3 2x5 1 3 2x6 1 4 2x7 1 5 2x8 2 3 2x9 2 4' 2x10 1 2 2" x 2" EXTRUSION HINGE LOCATIO HINGE LOCATION UPRIGHT SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2X3 MEMBER) PRIMARY 2" X 2" X 0.125" ANGLE (2) #10 X 3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE O O (TYP EACH SIDE) O 1" X 2" BASE MEMBER (TYP EACH SIDE) (1) - 3/8" 0 CONCRETE SCREW Q ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE 3" (MIN) SCREW ANCHOR @ 24" O.C. BETWEEN COLUMNS (TYP EACH SIDE) NOTES: 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT, 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON ITW RED HEAD® LDT 3/8" 0 STAINLESS STEEL CONCRETE SCREW. OTHER SIZE OR TYPE OF ANCHORS SHALL NOT BE USED. 4.2X2W/1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X3 SHOWN IN TABLE. 2" x 3" OR LARGER UPRIGHT TO CONCRETE W WO PAVER DETAILS $-3 SCALE:NTS DOOR 2" x 2" EXTRUSION NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. F TYPICAL SCREEN DOOR CONNECTION DETAIL S _ 3 SCALE:NTS 2" x _" MEMBER (SEE SHEET S-2 FOR SIZE) EAVE MEMBER ATTACHED TO 1"X2" OPEN BACK W/ (4) #10X2" SMS THRU SCREW BOSSES (typ) 1"X2"X0.045" OPEN BACK ATTACHED TO HOST W/ 1/4"0 X 2-3/4" EMBEDMENT MASONRY SCREW 3" FROM END &@ 24" O.C. OF WOOD USE IDENTICAL SIZE LAG) S2 S-3 HOST STRUCTURE EXISTING MASOP WALLGROUTED SOLID OR WOOD @ CONNECTION ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fbcplans.com C.O.A.429054 FORM HEADER OR DATE: 2-20-2018 INGCHANNEL DRAWN BY: TLK #10 SMS ATEACH RISER REVISION: DATE: r—FOR PAN OR #10 SMS @ RO 1 DATE: 3-13-2018 8' O.C. FOR COMPOSITE PANEL RO 2 SOLID ROOF RO 3 - RO 4 PROJECT ADDRESS: SCHURMANN 1-1/4" #10 SMS @ 8" O.C. 233 OLSON AVE (MIN) FOR COMPOSITE PANEL FORT PIERCE, FL 34946 (2) #10 SCREWS PER 12" WIDTH CONNECTING OR BACK OF PAN)PAN TO HEADER BOTTOM CONTRACTOR: (2) #10 X 2" SCREWS PER 12" WIDTH CONNECTING K & S INDUSTRIES, INC. HEADER OR CHANNEL TO FASCIA. 1379 SW BILTMORE ST. S1 ROOF PANEL TO FASCIA CONNECTION DETAILS PORT ST LUCIE, FL 34983 $-3 SCALE:NTS DETAILS S-3 THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC