Loading...
HomeMy WebLinkAboutLETTER OF APPROVAL BY HUD(�3-oi37 Palm Haybor Homes May 2, 2018 To: Building Department _J Bruce Bussell Engineering Manager /� Palm Harbor Homes, Inc. South Frontage Road i A •' [��[� `E13 Plgant City, Florida 3 563 9934 �� Phone: 813-752-1368 Ext.756 � + Fax 1: 813-754-8675 St Lucie county ` E-Mail Bbbussell@palmharbor.com RE: Palm Harbor Home, Serial Number #21054, Model 340TL30622A Savanna Club, Site 7026 I( Dear Plans Examiner, The site -beam, which was installed by Palm Harbor Homes, and is approved by HUD, Manufactured Home Construction & S fety Standards, is constructed to receive on -site additions that are built and designed b}jothers to accommodate such amenities as carports, sheds, and screen rooms. The on -site structure must be designed by a Florida, registered, engineer, to the Florida Budding Code and all local codes. This plant - installed site beam is of adequate design for this purpose as long as tie downs and piering are per page 1 of Section 11, Misc. & Final Inspection section of the installation manual (attached). The attached details, EW-P 16.2 and PA69-EW-31, are approved by the Manufactured Home Construction & Safety Standards. And, the design loads for the plant -installed site beam, as well as the supporting structure and anchorage are from the FBC and ASCE 7. 1 I can be of further assistance at the above contact information. Sincerely yours, Bruce Bussell Engineering Manager Palm Harbor Homes r� a• rY•l '+7Y Ciplion I using 2x4. let4n Metal Flat Secure. Roof.Panel Hkmdw Into 2x4 as apprcyad by Ro& Panel Header' Lap RAM -Lap Sic Option ,2:: Using 2x4 in., and exterior tiv! Root' Panel Sacur6 Roof Par iel: He6der 1nto2%4;Wappraysd by the.manufectunars Ineleflation Inskic0aft. Roo Panel Header 511kwne,CsuIk LAO.Recelvei Lap Skin I Q dadoed2X6 Wall -stud Cauk Vp.'Tnns, 2x4 03 S-P­F LAWn Fasten Into'bdc* wall shid, with Sea. 0.131x3" nalle. or 0--ea 711W 11W50.' appr1pv*d-ehe8V*,8 J.w.'ThennoplyoThetmosheath ,OSS or Plywood. loam 10. Doed en. ­ " ' __ ' P-F-' K2 ErIgineering. ino- id on -tgp of 61keath! nig studs AiLavilhum flat etcx* -StWPW amund 294 aw. iscamw Int0i soffiti and *xWhIng W metal strews.. E. vlo_nmim N4 #3 84W Fasten hft eachwall stud. with 4 im. W&W scirw4s. appraved sheathing I.e.: ThennopIV, The OSB or-PNwood'. APPROVED PFS.Corporation PALM HARBOR HOMES ING. Madison, W1 - 1 15303 DALLAS PARKWAY -:SUITE SOO. ADDISON. TX 75001 TnE Screen.roomano Cown adechment 09/1a/oo OCT 0 3 2000 Factory prep .options. HUD'. Manufactured Horne Construction & .,,NQ ZONE WUS EW EW - 216.2 ad-riz SECTION 11 — NIISCIELLANEOUS AND, FINAL .INSPECTIONS, Index 11A., AWN_jN6,_'eA"6ATS j Additional structures such asuwnings,,-c Harbor Home have not -typically been to design for roof .or Witfdloads. Any :addi and shall not intodere,° with w eaihemroqt] However, some Palm Harbof homes hav receiver designedto,take the loads of an. information oil d PERIMETER PIERS AND FOOTERS. AWNING -UNIT LOAD-@ SPACING WIDTH DTH WIDTH I - - - o.q.. 'FOR. - 16.x-16 '12" 140" -1160- 4440 # 6'-,3" 180,11 4788 # 5-9" 1 140" 1160" 4886 # 51-71. 180" 5235 # . 5'-7 20•, 140",] -1 0" •5334 # 6-1" 1 8q. 1 5684 # 1 4'-911. _.H UTILITY ROOMS,, ETC. ports, patio covers .or attabliments'to a Palm ,n into consideration nor calculated into the, iris made -to the home must b0:9,01f.7suppbrInng: ig (i.e. shingles; les, flashmig,.gutters, siding)., an, option toF be- ordered - with: a factory installed J&on., in-Ahis- case,, -refer to -the detail for - FACTORY INSTALLED DOUBLE SECTION HOME. RECEIVER . BY OTHERS �SITE INSTALLED, AWNING WIDTH 186'MAX. MA X. ��Z�j !��O"MAX­WZA UNIT WIDTI (14-0—M—FNTM BY OTHERS: 1 16'-0" MAX. - WZ-3, I - - '_ Perimeter piers and_fooUk-riotds: 1. _S,pa6ihg.f6f 16k'16is; based .oh 2000,ppfs oil'heari1ig­*q4p_aqty. 2. Refer to, -palm harbor homes installation -manual for footers: required for the loads, given o.c. Notes: I 3'. 4. 5. 6. 7. 8. -�-i 6"MAXIMUM INSET WZ 283 REQUIRE ANCHORAND VERTICAL TIE -4" ox. MAX., WITH.STABILIZER.P— V-0. O.C. MAX. 1 E UN WZ 293 REQUIRE TIE -DOWN ENGINFERING'VECTOR SYSTEM EQUAL) OR ANY QUALIFYING SY; SPECIFICALLY APPROVED FORE Vertical ticconnections have been, Actory,installed,to handle -the uplift and overtiihiing-- load the , nit along t-he additio"nalload from the awning, 1 - Imain- u� 49itIf w connection to themainunit. (bra:ck&s@' S1-411o.p. rhaY.) The factory -mstalled,re�coiver is designed to handle the additional uplift and downward loads from the.connectioir of the, awning to the main unit. The - awning roof and roof support away, -.from -.the in ain un it, must 'lie -designed -(by others) to carry all loads to the ground. The design of the awning connection alon_g With weatherization (by o1;hprs)=rAu§,t_be -designed to canythe appr9pni4te. load into the factory -insWiedreceiver. The -design must. be: a ocordigg to,,, th I e4oads and'.requ ireinents of the I RC2003 fo T,expos ure - 'c". Factory installed members were designed -for -awning loads based on 90- mph (3second gust) winds for wind zone 1,, 120 mph '(3'sec. g4st).. winds. for wind.zoim2, and .140 inph-(3 sec. gust).Vinds.,for'-wind zone 3. Tliisf isin accordance with IRC 2003 exposure V. For aijoroved lateral load i` i1e. re�iq mg�.sys stall�tiii reduirements- and nuniber-xeq i -d' refer to -other pAges in the Pal Harbor'Homes installation manual. No stabilizer plates arerequired.,zit anchors.loaded in direct(in,4ine) pull. This -design isfor '140." minimum floor width and 186" maximum floor W'ldffi on the main units 'andfor26--psf roof livi in, Wm__ lbold I 4D i`-d zones.. Maximurn pier heig htJnc1udiffg1-Lbeqrn for wind -'zone 1 is 5V -and. mimmum"height is 31'% Pier heights for wind zones 2 and; 3 are based. on vector system design. Section 11, Misc.,&-Fin9l Inspedtiov PMe I COPYRIGHT ti666 BY -PALM 'ilAR130PHOMiFS;INC. i All Rights Reserved