FL4904-118
Revision
2017
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
IN
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800) 663-3667
sschreiber@masonite.com
Steve Schreiber
sschreiber@masonite.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
Referenced Standard and Year (of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product
Certified By
Product Approval Method I Method 1 Option A
Date Submitted 12/15/2017
Date Validated 12/20/2017
Date Pending FBC Approv II
Date Approved 1 01/02/2018
Summary of Products
FL #
i
Model, Number or Name
Description
4904.1
Wood -edge heel Side -Hinged Door
6'-8" Opaque I/S and O/S Single Door
Units
Limits of Use I
Certification Agency Certificate
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
FL4904 R8 C CAC W006110 01 ndf
Quality Assurance Contract Expiration Date
Impact Resistant: Yes I
12/31/2020
Design Pressure: +76.0/-76.0 I
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0128.odf
Building Code Including the High Veldcity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements as determined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 3'-0" x 6'-8"
FL4904 R8 AE 514010A.odf
max nominal size. When large missile impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is NOT required. See
DWG-MA-FLO128-05 for details.
4904.2
Wood -edge Steel Side -Hinged Door
8'-0" Opaque I/S and O/S Single Door
Units
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL4904 R8 C CAC NI006110.02.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2020
Design Pressure: +70.0/-70.0 I
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0129.adf
Building Code including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements ias determined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 3'-0" x 8'-0"
FL4904 R8 AE 514009A.odf
max nominal size. When large missile impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is NOT required. See
DWG-MA-FLO129-05 for details.
4904.3
Wood-ei ge Steel Side -Hinged Door
6'-8" Opaque I/S and O/S Door w/ or w/o Sidelites
Units
Limits of Use I
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL4904 R8 C CAC NI006110.01.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes I
12/31/2020
Design Pressure: +55.0/-55.0
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0128.pdf
Building Code including the Higl1 Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements as determined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 12'-0" x 6'-8"
FL4904 R8 AE 514008A.odf
max nominal size. When large misslle Impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is NOT required on
opaque panels, but is required glazed panels. See DWG-
Ion
MA-FL0128-05.
4904.4
Wood -edge Steel Side -Hinged Door
8'-0" Opaque I/S Door w/ or w/o Sidelites
Units"
Limits of Use I
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL4904 R8 C CAC NI006110.02.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes 1
12/31/2020
Design Pressure: +45.0/-50.0
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0129.pdf
Building Code including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requlrements as determined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 12'-0" x 8'-0"
FL4904 R8 AE 514007A.odf
max nominal size. When large missile Impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is NOT required on
opaque panels, but Is required on glazed panels. See DWG-
MA-FL0129-05.
4904.5
Wood -edge Steel Side -Hinged Door
8'-0" Opaque O/S w/ or w/o Sidelites
Units
Limits of Use I
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL4904 R8 C CAC NI006110.02odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes 1
12/31/2020
Design Pressure: +50.0/-45.0
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0129.odf
Building Code including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements as determined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings antl Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 12'-0" x 8'-0"
FL4904 R8 AE 514007A.Ddf
max nominal size. When large missile impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is NOT required on
opaque panels, but is required on glazl d panels. See DWG-
MA-FL0129-05.
4904.6
Wood -edge Steel Side -Hinged Door
6'-8" Glazed I/S and O/S Door w/ or w/o Sidelites
Units
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes I
FL4904 R8 C CAC N1006110.03.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No I
12/31/2020
Design Pressure: +50.5/-50.5
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 IT FI-0130.odf
Building Code Including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements asldetermined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 12'-0" x 6'-8"
FL4904 R8 AE 514008A.Ddf
max nominal size. When large missile impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is required. See DWG -
MA-FLO130-05 for details.
i
4904.7
Wood -edge Steel Side -Hinged Door
8'-0" Glazed I/S Door w/ or w/o Sidelites
Units
Limits of Use
I
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL4904 R8 C CAC NI006110.04.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
12/31/2020
Design Pressure: +40.0/-45.0 I
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0131.Ddf
Building Code including the High Velocity Hurricane Zone,
determined by ASCE 7,
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
and where pressure requirements as
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 12'-0" x 8'-0"
FL4904 R8 AE 514007A.odf
max nominal size. When large missile impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is required. See DWG-
MA-FLO131-05 for details.
4904.8
Wood-ei ge Steel Side -Hinged Door
8'-0" Glazed O/S Door w/ or w/o Sidelites
Units
Limits of Use I
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL4904 R8 C CAC NI006110.04.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No I
12/31/2020
Design Pressure: +45.0/-40.0
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL4904 R8 II FL0131.odf
Building Code including the Higii Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements as determined by ASCE 7,
Created by Independent Third Party:
Minimum Design Loads for Buildings and Other Structures,
Evaluation Reports
does not exceed the design pressures listed. 12'-0" x 8'-0"
FL4904 R8 AE 514007A.Ddf
max nominal size. When large missile Impact resistance is
Created by Independent Third Party: Yes
required, hurricane protective system is required. See DWG-
MA-FLO131-05 for details.
Back Next
IContact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the' dfOce by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective Octoberll, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
I click here .
Product Approval Accepts:
® � ®. r�'LIir1 RM
Credit Card
Safe
o
SIDE -HINGED WOOD -EDGE STEEL DOOR UNIT
8'-0° GLAZED DOUBLE DOOR WITH / WITHOUT SIDELITES
GENERAL NOTES
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED.
2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED.
3. IN THE HVHZ, FACTORY PRIMED DOORS MUST BE PAINTED IN
ACCORDANCE WITH SECTION 2220 OF THE FBC.
4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
5. PLASTICS TESTING OF LITE FRAME MATERIAL -
TCM f1CCPC,Q}1ME, f,CC,fM,�T
SELF
SELF IGNITION TEMP ASTM D1929 740 'F > 650 -F
RATE OF BURNING ASTM D635 0.77 IN MIN
SMOKE DENSITY ASTM D2843 13.4%
TENSILE STRENGTH- ASTM D638 7.50% DIFF
• GOMPAKA11Vt IENSILL 51RENOIH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
AddndmloWR
Ceakag RNa
RelfMbf.
ma ReNCM4
• GOMPAKA11Vt IENSILL 51RENOIH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
AddndmloWR
Ceakag RNa
RelfMbf.
ma ReNCM4
149' W. OVERALL FRAME WM
21 " MAX 36.375' MAX. 37.5" MAX.
D.LO. PANEL WIDTH W/ASTRAGAL FRAME WIDTH
n
Li
I
L-1
I
&JllLJllLJ�
SINGLE DOOR UNIT DOUBLE DOOR UN R SINGLE DOOR UN R SINGLE DOOR UN ff SINGLE DOOR UNIT WISIDELITES
WITH SIDELDE WRH SIDELTTE
DOUBLE DOOR UNIT W/SIDELRES
id
WHERE WATER INFILTRATION PERFORMANCE IS DATE. 7 11 05
TABLE OF CONTENTS DESIGN PRESSURE RATING REQUIRED TO BE 159. OF DESIGN PRESSURE er.,c• N.T.S.
SHEET # DESCRIPTION CONFIG MAX WIDTH INSWING OUTSWING INSWING OUTSWING
1 TYPICAL ELEVATIONS & GENERAL NOTES X 3 .5 M+40.O-45.0W+45.O-40.0 +19.0 -19.0 +45.0 -40.0 Mm m: SWS2 ANCHORING LOCAl10NS &DETAILS XX 74 +19.0 -19.0 +450 -40.0CIO. Br
3 , ANCHORING LOCATIONS & DETAILS OX or XO 5 +19.0 -19.0 +45.0 -40.0 KURT BALTHAZOR DRAWIN No-OXO 112.5 +19.0 -19.0 +45.0 -40.0 FLORIDA P.E.OXXO 149 +19.0 -19.0 +45.0 -40.0 156533 DWG-MA-FL0131
%W 1 OF 3
SINGLE DOOR UNIT DOUBLE DOOR UN R SINGLE DOOR UN R SINGLE DOOR UN ff SINGLE DOOR UNIT WISIDELITES
WITH SIDELDE WRH SIDELTTE
DOUBLE DOOR UNIT W/SIDELRES
id
WHERE WATER INFILTRATION PERFORMANCE IS DATE. 7 11 05
TABLE OF CONTENTS DESIGN PRESSURE RATING REQUIRED TO BE 159. OF DESIGN PRESSURE er.,c• N.T.S.
SHEET # DESCRIPTION CONFIG MAX WIDTH INSWING OUTSWING INSWING OUTSWING
1 TYPICAL ELEVATIONS & GENERAL NOTES X 3 .5 M+40.O-45.0W+45.O-40.0 +19.0 -19.0 +45.0 -40.0 Mm m: SWS2 ANCHORING LOCAl10NS &DETAILS XX 74 +19.0 -19.0 +450 -40.0CIO. Br
3 , ANCHORING LOCATIONS & DETAILS OX or XO 5 +19.0 -19.0 +45.0 -40.0 KURT BALTHAZOR DRAWIN No-OXO 112.5 +19.0 -19.0 +45.0 -40.0 FLORIDA P.E.OXXO 149 +19.0 -19.0 +45.0 -40.0 156533 DWG-MA-FL0131
%W 1 OF 3
6' SEE DETAIL 6'
J L 3" L E' 33' L
3" I I E I 3" �" r I I 1 31
;EE DE
6 '6' —
6"6
I I IT-
W
Q
y
0
w
B
L
B
O
a B
A
A
6' 6-
6' 3"
6"
io
3" f C LI 1 3" e 3- '1 I—
3' 3'
SEE DETAIL 6'
io
U
U)
a
Aev�SdBY.
#10 x 2„ D2te�r�e9 � Ate_
#8 x 2-1/2"
- #8 x 2-1/2" #10 x 5/8"
#8 x 2-1/2" #10 x 2" #10 x 3/4"
#10 x 5/8" DETAIL "E" ASTRAGAL
• FRAME / DOOR ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME
DETAIL "C" AS SHOWN.
DETAIL "D" TYPICAL
1 D.96z l
,.s7s-
T T�
INSWING THRESHOLD OUTSWING THRESHOLD
SEE DEL
D'
SEE DETAIL
'C'
ASTRAGAL RETAINER BOLT HOLE -
MUST BE DRILLED THROUGH
THE THRESHOLD & INTO THE
STRUCTURE DEEP ENOUGH
FOR A 1.375" THROW
DETAIL "F" ASTRAGAL
IG (1/8- TEMP. GLASS)
DDW 995*-IN.ITMOR
W/ OPSTEE L R BUTYL
SPACER
ALUM, STEEL OR BUM SPACER
1/2- BITE
DOW 995
TYPICAL GLAZING DETAIL
a Lo
00
o
j (D
Q �
p �J
H
C9
_ a U
�U-)U
Z �
co
3
g
�a
p wz�
SCAM- N.T.S.
DWG. ft sws
BY:
OF
SEE DETAIL
io
a
SEE DETAI
"C" SHL
T-
6
ATTACHMENT DETAIL =F' sHT; 2
—1—ANCHOR—ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY—LUIS—R-LOMDS—PE
(FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND 1.25"
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE MIN o - �.. ; �-
#10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL SHIM
"AM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR CL
)CATION. TAPCON EDGE DISTANCE MIN 2-1/2".
_4OOD SCREW EDGE DISTANCE MIN 3/4 ~'
2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE TYPICAL MASONRY
FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO ANCHOR INSTALLATION
BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG
CORRUGATED EASTERNERS LOCATED 3" FROM EACH END t.
AND MAX 7" O.C. OR #10 X 2" FLAT HEAD WOOD
SCREWS LOCATED 6" FROM EACH END AND MAX 12" O.C. MIN _ 0.25"
MAX
3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM SHIM
ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT CL _I I_
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE ""
MINIMUM EMBEDMENT OF 1-1/4".`
4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO
TRANSFER LOADS TO STRUCTURE. TYPICAL WOOD BUCK
5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. ANCHOR INSTALLATION
3 I I a 6"3 I I r C 1 I I 6" G I I 31
DETAIL
SHT. 2
I III
s• s•
3'
11 I
�
W
a
a
N
J
D
W
W
B
8
D:
Q B
6.
3- 3.1
s-
HARDWARE S(HFf1111 F
1.
KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED
AT 10-1/2" CENTERLINE.
2.
4" X 4" FULL MORTISE BUTT HINGES
A ,,,M O M arE: 7 7 7 Ub
sc� N.T.S.
r °"rta Ow. Ely. SINS
flsrie�edBY
Data Cwc. Of.
OF