Loading...
HomeMy WebLinkAboutRESIDENTIAL GENERATORr 16/20/2VRAW ST,LUM COUMY PLAN I'MMiEW BLDG:' DATE:: GENERAC ELEC. ..... j DAT�'7'� PLUMB: GUARDIAN® SERIES DATE: MECH: Residential Standby. Generators i `Am— SGANNEV) Air -Cooled Gas Engine INCLUDES: • True Power" Electrical Technology • Two Line LCD Multilingual Digital i . Evolution TM Controller (English/Spanish/ French/Portuguese) • , Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) 716 kW 60 Hz Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz See Page 4 for Details.— ' • Electronic Governor • System Status & Maintenance Interval LED . Indicators i • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation, C&S • 5 Year Limited Warranty LISTED QUI Note: CUL certification only applies to unbundled units and units packaged with • Capability to be installed within 18" (457 mm) limited circuit switches, Units packaged with the Smart Switch are UL certified in the USA only. of a building* 'Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's .0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible. Generac's G-Farce engine This state-of-the-art power maximizing regulation system is standard an lineup offers added peace of mind and reliability,' for when you need it the most. The . all Generac models. It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O TRUE POWER' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O .SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5% Total Harmonic Distortion for utility quality power. This allows network provides parts and service know-how for the entire unit, from the confident operation of sensitive electronic equipment and micro -chip based appliances, engine to the smallest electronic component , such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J • PROTOTYPE TESTED V11, HEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes Its own transfer J SYSTEM TORSIONAL TESTED ✓' MOTOR STARTING ABILITY systems and controls for total system compatibility. w GENERAC LL�{�� PROMISE Link y7BHA� a i •Bultl N IRO USAu9ny OOmONk one "yp/p/, y!!"L GENERAC" 1 �/20/22' kW .......... _...... _.. _ .-_ .. features and 'bene its __.�..�-- .........._� Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalis and plasma moly rings helps the engine run cooler, reducirig oil consumption resulting in longer engine life. • "Spiny -loll' cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubricaon system Pressurized lubrication ation to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 ye4/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 %prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Remote mounting Transfers your vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Mounts near your existing distribution panel for simple, low-cost installation. Evolution" Controls • Auto/Mabual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. for • Sealed, raised buttons Smooth, weather -resistant user interface programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65°% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantlymonitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to.the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit ' • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for 'added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. . • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. GENERAC° 16/2(T/22'kW . ...specifications Generator Model G007035.0, G007036-0, G007038.0, G007039-0 G0� 07`042,q G0970.0 G007037.0 (16 kW) (20 M 4 2( ZL . Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Ota{2[()1_=0��1(Ci�fStOrtlOn�'`'`}IIt k�°'i^^,,aiL�N:� '"s,''r"�''"5 G'br ?sf:SS12rje� r.u�CSScl15't•`'re-'""«'C'�haflga i'3 s'me. Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp 2 2 Power Factor 1.0 1.0 1.0 �at1e�R,eq iut �ent�(pot; c3�ed^�,y°�����'��.� �`����,�,�,�'�.'�-,��p�.�2_FnVoII�s;�G�.aup26fl54000AMnlmum�d rQu,^35AG�650�CCA�Minimu�r�` Unit Weight (lb/kg) 406/186 448/203 466/211 Sound output In dB(A) at 23 it (7 m) with generator operating at normal load" 66 66 67 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Farce 1000 Series �UplbCr�Of� �nd(S.'"�"3k'�34,',',��'+r�?^y��t�fi�` J>r�w�<� r Gs 't €F "'.'�`� ,� : ""—�v�' � 'w'-'"�:•z:.�y�?rn+'�i2 �'.r� ^+',k.,.. �'rr'1i�,2w ,���'�.��'a Disolacement 999 cc 999 cc 999 cc Valve Arranaement Overhead Valve Overhead Valve Overhead Controls 2-Line Plain Text Multilingual.LCD Display Simple user interface for ease of operation. start delay between 2-1500 Set Capable Exerciser/Exercise Set Charger Common Start with starter control, unit stays on. If utility fails, transfer to load takes place. Standard Standard 16 sec on, 7 rest "Sound levels are taken from the front of the generator. Sound levels taken tiom other sides of the generator maybe higher depending an Installation parameters. Bating definitions -Standby. Applicable for supplying emergency power for the duration of the utility power outage. No ovedoad capability is available for this rating: (Ail ratings in accordance with BS5514. IS03046 and DIN6271). - Mardmum Mlovolt amps and currentare subject to and limited by such factors as fuel Bhpmegajoule content, amblenttemperature, altitude, engine powerand condition, etc. Maximum power decreases about3.5 percentforeach 1,000 feet (304.8 motors) above sealevel; and alsowill decrease about 1 percentforeach VC (101r) above 16°C (60 T). GENERACO 16/20/22 kW i............._......- switch options Limited Circuits Switch Features • 16 circuits, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both; inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both capper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1° standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Depth H1 H2 W1 W2 InE266.75JE7643 10.5 13.5 6.91 mm 266.7 � 343.0 17-5 4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#.14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240,1e OpenTransition Service Rated Height Ht H2- Width W1 W2 Depth In 26.75 30.1 10,5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Model G007036-0 (16kW) Current Rating (Amps) 100 Vol el aUpB NACu�" V s2012,40 3Nr Utility Voltage Monitor (Fixed)* -Pick-up 80% Dropout 65% Ear ,: E.6 r N<� �a' :•,- a roz 'seuc m Exercises bl-weekly for 5 minutes*t Standard LULL sled "'`c�xfzs Total Circuits Available 16 Tandem eak GCa `a'bp i ities� erg �B spaces Circuit Breaker rotected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly Model G007037-0 (16 kW)/GO07039.0 (20 kW)/ G007043-0 (22 kW) Current Rating (Amps) 200 t�.�?9��.n9 (VA�)�,.r .� .��: ,� �-ax •�� "; :. 20/240,�1 d�«'.''�`"� Utility Voltage Monitor (Fixedt* -Pick-up 80% -Dropout 65% rd'.w.:6.•_. .` d. -..; -uy �i'.Mu:�..s...s,ra:.,adt:.e..S�.%�.:..k• Exercises bi-weekly for 5 minutes* Standard Enclosure Type NEMA/UL3R Ci" if Br of d r am` a r Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise cari be set to weekly or monthly 16/20/22 W. GENERAL available acesseries ."4 RiFtifttx 1�`..-V Li,Y' 4i, ITJ'S2�..,'ttKN N�,.9'�t-`i.,.,.,.Paz"3�4��:r'•.-�r..-.�3s�w..�S..-:2.�..-.+��'�L--..^. _ ;�yx���,lF A.; ':`Si`.. � Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- 1 G006463-4 Mobile Link- °s cess to an Internet connection from a PC or with any smart device. You will even be notified via a -mall ar text�message when a change in the generator's status occurs. Available in the U.S. only. Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet I G0058 19-0 26R Wet Cell Battery t cell, battery for use with all air-cooled standby product (excluding PawerPact@). µ I )G007101-0 --- r Battery Pad Warmer Thepadwarmerrests.underthebattery.Recommendedforuseiflhetempi;raturereguladyfallsbelow0°F.� .(Not necessary for use with AGM -style batteries). Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below IG007102-0 Oil Warmer 0°F. 1 G007103-0 _ I Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. i 1 G005621-Ow Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out,a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 -Bisque Fascia Base Wrap Kit sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting. (Standard on 22 kW) holes located in the base. 1 If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint Idt includes the necessary paint to properly maintain or touch-up a generator - enclosure. IG006485-0 Scheduled Maintenance Kft Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance an a Generac automatic standby generator. 1 G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its �_ Power management capabilities.Itprovides additional power management flexibility not found inany other: (50Amps) i 1 power management system. dimensions & PCs Dimensions shown are approximate. Refer to Installation manual for erect dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFTSIDEVIEW GENERAC® Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 rb.-I°1 FRONTVIEW Generac Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 - generac.com ,02016 Generac Power Systems, Inc. Ali rights reserved. All specifications are subject to change whhout notice. Pad No. 100000001 94-D 10/24/16