HomeMy WebLinkAboutENERGY EFFICIENCY CODE1
FORM R405-2017
FLORIDA, ENERGY EFFICIENCY CODE FOR BUILDING
Florida Department of Business and Professional Regulation - Residential
CONSTRUCTION
Performance Method
Project Name: BOWMAN ADDITION
Builder Name:
Street: 5710 BIRCH DRIVE p�R`
�����r17���
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, 34982
Permit Number:1803-0147
Owner: DONALD & KRYSTINA BOWMAN B ll
Jurisdiction:
Design Location: FL, Fort Pierce �� LUCIe Co UrIt0ounty:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types(384.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 384.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms(Bedrms In Addition) 0(0) j
d. N/A
R= ft2
10. Ceiling Types (288.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 288.00 ft2
6. Conditioned floor area above grade (ft2) 288
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(46.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: ADDITION
6 57
a. U-Factor: Dbl, U=0.67 40.00 ft2
SHGC: SHGC=0.30'
b. U-Factor: Dbl, U=0.29 6.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21 I
a. Central Unit
41.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.288
14. Hot water systems - None required
a.
Cap: N/A
8. Floor Types (288.0 sqft.) Insulation Area
EF: 3.28016E010
a. Slab -On -Grade Edge Insulation R=0.0 288.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 12.91
Glass/Floor Area: 0.160
Total BaselinePASS
Loads: 13.15
I hereby certify that.the plans and specifications covered by
Review of the plans and
40E S7-Al
this calculation are In compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
iiq
•;,.•�, ",�
with the Florida Energy Code.
n+n+'°., •;y:J:. O
PREPARED BY:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
O - k 11 X
I hereby certify that -this building as designed, is in compliance
Florida Statutes.
it the•Fforida�frrergyzGode
; Fr W �,W.� ;..
�y�
WE
r
OWNER/AGENT:
BUILDING OFFICIAL:
DATE
DATE:
y x..fi<x
= Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/2/2018 3:57 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant S e f 4 a
PnRIVI R4n5_gn17
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
BOWMAN ADDITION Bedrooms: 0
User Conditioned Area: 288
DONALD & KRYSTINA BOW Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
ST. LUCIE COUNTY Cross Ventilation:
Whole House Fan:
Single-family
Addition
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
5710 BIRCH DRIVE
St. Lucie
FT. PIERCE,
FL, 34982
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH _MUNI 39 90
70 75 299
62 Low
BLOCKS
Number
Name
Area Volume,
1
Block1
288 2304
SPACES
Number'
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
ADDITION
288 2304 1 Yes 288
i
1 Yes
Yes Yes
, FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio ADDITION 75 ft 0
288 ftz ____
1 0 0
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt
Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
.1
Hip Composition shingles 312 ftZ 0 ftz Light
0.6 No 0.9
No 0 22.6
ATTIC
V/ #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150
288 ftz N N
CEILING
#
.Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
ADDITION 30 Blown 288 ft2 0.11
Wood
4/2/2018 3:57 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
GnRM PArlr,-7r117
WALLS
'Adjacent
Cavity ity Width Height
Sheathing Framing Solar
Below
()rat
In WaH TA(pe
1 N
Exterior Frame - Wood
ADDITION 13 12 8
96.0 ft2
0.23 0.6
0
2 E
Exterior Frame - Wood
ADDITION 13 24 8
192.0 ft2
0.23 0.6
0
3 S
Exterior Frame - Wood
ADDITION 13 12 8
96.0 ft2
0.23 0.6
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt 'ID Frame Panes
NFRC U=Factor SHGC Imp Area
Depth
Separation Int Shade
Screening
1
E 2 Vinyl Low-E Double Yes 0.29 0.21 N 6.0 ft2
2 ft 0 in
1 ft 4 in Drapes/blinds
None
2
S 3 Vinyl Low-E Double Yes 10.67 0.3 N 40.0 ft2
I
2 ft 0 in
1 ft 4 in Drapes/blinds
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000356 268.8 14.76 27.75
i
.2598
7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
I. Electric Strip Heat/Existing/co None COP:1 34 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/Existing/confirme None SEER: 15 41 kBtu/hr 1230 cfm 0.8 1 sys#1
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model # Collector Model # Area Volume FEF
ft2
DUCTS
/ — Supply — -- Return — I- Air CFM 25 CFM25 HVAC #
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 57 ft2 Attic 1 ft2 Default Leakage ADDITION (Default) (Default) 1 1
4/2/2018 3:57 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
TEMPERATURES
ProgramabJe Thermostat: Y
Ceiling Fans:
Cool' Jan
Heating Jan
Feb
. Feb
Mar
Mar
A r
Apr
Ma
j May
X Jun
4j Jun
X Jul
4� Jul
[X] Au
Aug
[ ]
rj
Se
Sep
Oct
Oct
H Nov
Nov
Dec
f X Dec
Ventin Jan
'Feb
X
X Mar
[X
A r [
Ma '
[ Jun
[ Jul
E)
] Au
[ ]
Se
Oct
Nov
[ Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type,
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
4/2/2018 3:57 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
2017 - AIR BARRIER AND INSL## _TION INSPECTION COMPONENT G.,-:FERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: BOWMAN ADDITION Builder Name:
Street: 5710 BIRCH DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, 34982 Permit Number:1803-0147
Owner: DONALD & KRYSTINA BOWMAN Jurisdiction:
Design Location:. FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a ccontinuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
i
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor irisulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be!sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation .
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pmp*ng and wiring,
Shower/tub
The air barrier installed at exterior walls' adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o'
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots.
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed, fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
'
Caulking or other adhesive sealants shall not be used to fill voidsbetween fire spflnklgr cover plates gndwalls or ceoluncs-
a. in addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
4/2/2018 3:57 PM EnergyGauge@) USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor'area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.67
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.29
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5710 BIRCH DRIVE, FT. PIERCE, FL, 34982
Addition
Single-family
1
0(0)
No
288
Area
40.00 ft2
6.00 ft2
ft2
ft2
2.000 ft.
0.288
Insulation Area
R=0.0 288.00 ft2
R= ft2
R= ft2
9. Wall Types
a. Frame - Wood, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: ADDITION
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems - None required
a.
b. Conservation features
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction'through the above energy saving features which will be installed (or exceeded)
in this home,before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Insulation
R=13.0
R=
R=
R=
Insulation
R=30.0
R=
R=
Area
384.00 ft2
ft2
ft2
ft2
Area
288.00 ft2
ft2
ft2
R ft2
6 57
kBtu/hr Efficiency
41.0 SEER:15.00
kBtu/hr Efficiency
34.0 COP:1.00
o
Cap: N/A
EF:
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/2/2018 3:57 PM, EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
+ wriglksofto
Proiect Summary Job: :
Enure House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM
imect intormation
For: BOWMAN ADDITION
5710 BIRCH DRIVE, FT. PIERCE, FL
Notes:
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Outside db
Inside db
Design TD
Daily range
Reative humidity
Moisture difference
90 OF
75 OF
15 OF
L
50 %
61 gr/lb
Heating Summary
Structure
17643
Btuh
Ducts
5646
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
23289
Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Heating Cooling
.Area (ftZ 1618 1618
Volume ()ft3) 15209 15209
Air changes/hour 0.38 0.20
'Equiv. AVF (cfm) 96 51
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
6.1 kW
20877 Btuh
14 OF
1367 cfm
0.059 cfm/Biuh
0.08 in H2O
Sensible Cooling Equipment Load Sizing
Structure
24133
Btuh
Ducts
4223
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 26939 Btuh
Latent Cooling Equipment Load Sizing
Structure
3318
Btuh
Ducts
2715
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
6033
Btuh
Equipment total load 32972 Btuh
Req. total capacity at 0.70 SHR 3.2 ton
Cooling Equipment Summary
Make American Standard
Trade EXISTING SYSTEM
Cond 4A7A5042E1
Coil GAM5AOC42M31SAA
AHRI ref
Efficiency 12.0 EER, 15 SEER
Sensible cooling
28700
Btuh
Latent cooling
12300
Btuh
Total cooling
41000
Btuh
Actual air flow
1367
cfm
Air flow factor
0.048
cfm/Btuh
Static pressure
0.08
in H2O
Load sensible heat ratio
0.82
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Apr-02 15:52:22
wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
ACCA C:\Users\Quick Calcs\Documents\BOWMAN ADDITION.rup Calc = MJ8 Front Door faces: W
-�- wrightsoft° Right-JO Worksheet
- Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM
1
Room name
Entire House
EXISTING HOUSE
2
Exposed wall
178.0 ft
130.0 ft
3
Room height
9.4 ft d
9.4 ft heat/cool
4
Room dimensions
1.0 x 1330.0 ft
5
Room area
1618.0 ftz
1330.0 ftz
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area (ftz)
Load
number
(Btuh/ft'-°F)
(Btuh/ft�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
_____0.091.
n
_ .-2.55
2.18
_ .- 40_4
._ 404
_.. _ 1030
_ _ _ 883
_ 291
- .__. . 291,
_ __ _ _742
_ _ _ _636-
1RJ
12C-Osw
0.091
a
2.55
2.18
432
426
1086
931
207
207
527
452
' C
- - -
4A5 tom - -
0.770
- a
- 21.56
4.2.10
6
2
129
- 253
0
- 0
0
0
y✓
12C-0sw `
0.091
s-
2.55
_
2.18
_ 404
363
926
- 794
_. 291
201
_ _
742
_ _
636
11
-!—G_
4A5-2om- -------_—__-0.770
.s_,
_ _21.56
---19.31..__.-
.41...--
__ 82
-- - _880.------
.788
-.__0
— ____ -0-----_-__0._--
_-- .0
Vj✓
12C-0sw
0.091
w
2.55
2.18
432
321
819
702
432
321
819
702
1A-c1om
1.270
w
35.56
91.12
90
0
3200
8201
90
0
3200
8201
i�—Gp
11 DO _ , .
0.390
w
10 92
11.3
21
21
229.
238
21
238
C_ __ _
16D-30td _- . _. _._ _ _
_. ._-_0.032
,
... -_
.,-_-0.90,
,
- - 1.04
_ _ 1618
_
_ _ 1618,
- - _-_ 1450
_,,, _ -
_ 1.6.83
......
_ 1330
, _ - .21
._ ._ _ 1330
_ _229
,_- __ 1192
_ __
_ ___1383
F -. _.
22A_tpl _ _ _ LL_ ,-. - -,
_ _ ..- 0.989
_-- _
27.69
_0.00
- ., 1618
_ _ _ - 178
4929
- 0
- _ 1330
_,_.• _- 130
, _ _3600
.- _-. _0
-
- - -------
s
6
c) AED excursion
3446
3504
Envelope loss/gain
14679
17917
11052
15752
12
a) Infiltration
2964
836
2165
610
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
6
1380
4
920
Appliances/other
4000
2000
Subtotal (lines 6 to 13)
17643
24133
13217
19282
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17643
24133
13217
19282
15
Duct loads
32%
17%
5646
4223
32%
17%
4230
3374
Total room load
23289
28356T
17447
22657
Air required (cfm)
1367
1367
1
1024
1092
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft� 2018-Apr-02 15:52:22
Right -Suite® Universal 2017 17.0.14� RSU081 01 Page 1
'4aC�` C:\Users\Quick Calcs\Documents\BOWMAN ADDITION.rup Calc = MJ8 Front Door faces: W
f r
i .
+- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
,
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALC3@/1OL.COM
1
Room name
NEW KITCHEN/DIN.
2
Exposed wall
48.0 ft
3
Room height
9.4 ft heaticool
4
Room dimensions
24.0 x 12.0 ft
5
Room area
288.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Area
Load
number
(Btuh/W-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W _ _.
12C,Osw — _,_
_
_-_ w_0 091
_ _ n. _
2.55
- _ 2 18
--
_ - 113'_
_113
_ __ ___"
_____.287
__
- ___246
, _ ____
_
- - -
__
y✓
12C-Osw
0.091
a
2.55
2.18
226
220
560
480
_ _C
4A572om _ -_ _ _
_ 0 7/0
e
42.10
6
1
129
253
yJ •
_
12C-Osw'
_
0 O91
_
's
_21.56
2.55
____2_.18
113
72
_-
183
_ _
157
--
-
11
_�—G_
4A5 2om__.__ _.
_ _ 0 770
--_ 21.56
19.31!
.41
41
,__ 788---
V�l'
I�Gp
12C-Osw
1A-c1om
0.091
1.270
. _s__
w
w
2.55
35.56
_.
2.18
91.12
_
0
0
_,_ _.
0
0
_-880
0
0
_
0
0
11D0-
OMO
w_
10.9.2
0.
0
_._
C:_._�_.15D-30td_
-
__ .__
-
.._ 0.032---_--__-
_
0.90
_. .11.31
_104:.--___._286'.",,.._.288..___�258
-
---0
_.__0._.-
-
-
------------
-_0.989
_. - .
27.66
_-0.00
__. _. _ 286
48-
_. _ _ 1329_
.- — _ --- 0
6
c) AED eXcursion
-58
Envelope loss/gain
3627
2165
12
a) Infiltration
799
225
b) Room ventilation
0
0
13
Internal gains: Occupants @ 230
2
460
Appliances/other
2000
Subtotal (lines Q.to 13)
4426
4851
Lt ss external load
0
0
'Lass transfer
0
0
redistribution
0
0
14
Subtotal
4426
4851
15
Duct loads
32%
17%
1416
849
Total room load
5842
5700
Air required (cfm)
'143
275
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrightsoft" 2018-Apr-02 16:52:22
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2
C:\Users\Quick Calcs\Documents\BOWMAN ADDITION.rup Cale = MJ8 Front Door faces: W
k
-�- wrightsoft° Duct System Summary Dae.
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
For: BOWMAN ADDITION
5710 BIRCH DRIVE, FT. PIERCE, FL
Heating
Cooling
External static pressure
0.08
in H2O
0.08
in H2O
Pressure losses
0
in H2O
0
in H2O
Available static pressure
0.08
in H2O
0.08
in H2O
Supply / return available pressure
0.040 / 0.040
in H2O
0.040 / 0.040
in H2O
Lowest friction rate
1.000
in/ 100ft
1.000
in/100ft
Actual air flow
1367
cfm
1367
cfm
Total effective length (TEL)
131 ft
SupplyDetail
Table
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FR
(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
EXISTING HOUSE-E
c 22657
1024
1092
1.000
15.0
OxO
VIFx
0
0
NEW KITCHEN/DIN.
h 2921
171
137
1.000
6.0
Ox0
VIFx
15.1
115.0
st1
NEW KITCHEN/DIN':-A
h 2921
171
137
1.000
6.0
Ox0
VIFx
15.9
115.0
st1
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st1
Peak AVF
343
275
1.000
776
9.0
0 x 0
VinlFlx
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
OxO.
1367
1367
0
0
0
0
Ox 0
VIFx
A— wri htsofta 2018-Apr-0215:62:22
�. � 9 Right -Suite® Universal 2017 17.0.14. RSU08101 Page 1