Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE1 FORM R405-2017 FLORIDA, ENERGY EFFICIENCY CODE FOR BUILDING Florida Department of Business and Professional Regulation - Residential CONSTRUCTION Performance Method Project Name: BOWMAN ADDITION Builder Name: Street: 5710 BIRCH DRIVE p�R` �����r17��� Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, 34982 Permit Number:1803-0147 Owner: DONALD & KRYSTINA BOWMAN B ll Jurisdiction: Design Location: FL, Fort Pierce �� LUCIe Co UrIt0ounty:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types(384.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 384.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) j d. N/A R= ft2 10. Ceiling Types (288.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 288.00 ft2 6. Conditioned floor area above grade (ft2) 288 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(46.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: ADDITION 6 57 a. U-Factor: Dbl, U=0.67 40.00 ft2 SHGC: SHGC=0.30' b. U-Factor: Dbl, U=0.29 6.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 I a. Central Unit 41.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.288 14. Hot water systems - None required a. Cap: N/A 8. Floor Types (288.0 sqft.) Insulation Area EF: 3.28016E010 a. Slab -On -Grade Edge Insulation R=0.0 288.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 12.91 Glass/Floor Area: 0.160 Total BaselinePASS Loads: 13.15 I hereby certify that.the plans and specifications covered by Review of the plans and 40E S7-Al this calculation are In compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance iiq •;,.•�, ",� with the Florida Energy Code. n+n+'°., •;y:J:. O PREPARED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 O - k 11 X I hereby certify that -this building as designed, is in compliance Florida Statutes. it the•Fforida�frrergyzGode ; Fr W �,W.� ;.. �y� WE r OWNER/AGENT: BUILDING OFFICIAL: DATE DATE: y x..fi<x = Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/2/2018 3:57 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant S e f 4 a PnRIVI R4n5_gn17 PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: BOWMAN ADDITION Bedrooms: 0 User Conditioned Area: 288 DONALD & KRYSTINA BOW Total Stories: 1 1 Worst Case: No Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: Whole House Fan: Single-family Addition Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 5710 BIRCH DRIVE St. Lucie FT. PIERCE, FL, 34982 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume, 1 Block1 288 2304 SPACES Number' Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ADDITION 288 2304 1 Yes 288 i 1 Yes Yes Yes , FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ADDITION 75 ft 0 288 ftz ____ 1 0 0 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) .1 Hip Composition shingles 312 ftZ 0 ftz Light 0.6 No 0.9 No 0 22.6 ATTIC V/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 288 ftz N N CEILING # .Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 288 ft2 0.11 Wood 4/2/2018 3:57 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 GnRM PArlr,-7r117 WALLS 'Adjacent Cavity ity Width Height Sheathing Framing Solar Below ()rat In WaH TA(pe 1 N Exterior Frame - Wood ADDITION 13 12 8 96.0 ft2 0.23 0.6 0 2 E Exterior Frame - Wood ADDITION 13 24 8 192.0 ft2 0.23 0.6 0 3 S Exterior Frame - Wood ADDITION 13 12 8 96.0 ft2 0.23 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt 'ID Frame Panes NFRC U=Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Double Yes 0.29 0.21 N 6.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 2 S 3 Vinyl Low-E Double Yes 10.67 0.3 N 40.0 ft2 I 2 ft 0 in 1 ft 4 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 268.8 14.76 27.75 i .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts I. Electric Strip Heat/Existing/co None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Existing/confirme None SEER: 15 41 kBtu/hr 1230 cfm 0.8 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ft2 DUCTS / — Supply — -- Return — I- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 57 ft2 Attic 1 ft2 Default Leakage ADDITION (Default) (Default) 1 1 4/2/2018 3:57 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 TEMPERATURES ProgramabJe Thermostat: Y Ceiling Fans: Cool' Jan Heating Jan Feb . Feb Mar Mar A r Apr Ma j May X Jun 4j Jun X Jul 4� Jul [X] Au Aug [ ] rj Se Sep Oct Oct H Nov Nov Dec f X Dec Ventin Jan 'Feb X X Mar [X A r [ Ma ' [ Jun [ Jul E) ] Au [ ] Se Oct Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type, 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/2/2018 3:57 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSL## _TION INSPECTION COMPONENT G.,-:FERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BOWMAN ADDITION Builder Name: Street: 5710 BIRCH DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, 34982 Permit Number:1803-0147 Owner: DONALD & KRYSTINA BOWMAN Jurisdiction: Design Location:. FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed In the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a ccontinuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic i The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor irisulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be!sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation . Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pmp*ng and wiring, Shower/tub The air barrier installed at exterior walls' adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box o' The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots. HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed, fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. ' Caulking or other adhesive sealants shall not be used to fill voidsbetween fire spflnklgr cover plates gndwalls or ceoluncs- a. in addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 4/2/2018 3:57 PM EnergyGauge@) USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor'area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.67 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.29 SHGC: SHGC=0.21 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 5710 BIRCH DRIVE, FT. PIERCE, FL, 34982 Addition Single-family 1 0(0) No 288 Area 40.00 ft2 6.00 ft2 ft2 ft2 2.000 ft. 0.288 Insulation Area R=0.0 288.00 ft2 R= ft2 R= ft2 9. Wall Types a. Frame - Wood, Exterior b. N/A c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: ADDITION 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems - None required a. b. Conservation features 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction'through the above energy saving features which will be installed (or exceeded) in this home,before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Insulation R=13.0 R= R= R= Insulation R=30.0 R= R= Area 384.00 ft2 ft2 ft2 ft2 Area 288.00 ft2 ft2 ft2 R ft2 6 57 kBtu/hr Efficiency 41.0 SEER:15.00 kBtu/hr Efficiency 34.0 COP:1.00 o Cap: N/A EF: Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/2/2018 3:57 PM, EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 + wriglksofto Proiect Summary Job: : Enure House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM imect intormation For: BOWMAN ADDITION 5710 BIRCH DRIVE, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Outside db Inside db Design TD Daily range Reative humidity Moisture difference 90 OF 75 OF 15 OF L 50 % 61 gr/lb Heating Summary Structure 17643 Btuh Ducts 5646 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23289 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling .Area (ftZ 1618 1618 Volume ()ft3) 15209 15209 Air changes/hour 0.38 0.20 'Equiv. AVF (cfm) 96 51 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 6.1 kW 20877 Btuh 14 OF 1367 cfm 0.059 cfm/Biuh 0.08 in H2O Sensible Cooling Equipment Load Sizing Structure 24133 Btuh Ducts 4223 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 26939 Btuh Latent Cooling Equipment Load Sizing Structure 3318 Btuh Ducts 2715 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6033 Btuh Equipment total load 32972 Btuh Req. total capacity at 0.70 SHR 3.2 ton Cooling Equipment Summary Make American Standard Trade EXISTING SYSTEM Cond 4A7A5042E1 Coil GAM5AOC42M31SAA AHRI ref Efficiency 12.0 EER, 15 SEER Sensible cooling 28700 Btuh Latent cooling 12300 Btuh Total cooling 41000 Btuh Actual air flow 1367 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0.08 in H2O Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Apr-02 15:52:22 wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACCA C:\Users\Quick Calcs\Documents\BOWMAN ADDITION.rup Calc = MJ8 Front Door faces: W -�- wrightsoft° Right-JO Worksheet - Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House EXISTING HOUSE 2 Exposed wall 178.0 ft 130.0 ft 3 Room height 9.4 ft d 9.4 ft heat/cool 4 Room dimensions 1.0 x 1330.0 ft 5 Room area 1618.0 ftz 1330.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft'-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _____0.091. n _ .-2.55 2.18 _ .- 40_4 ._ 404 _.. _ 1030 _ _ _ 883 _ 291 - .__. . 291, _ __ _ _742 _ _ _ _636- 1RJ 12C-Osw 0.091 a 2.55 2.18 432 426 1086 931 207 207 527 452 ' C - - - 4A5 tom - - 0.770 - a - 21.56 4.2.10 6 2 129 - 253 0 - 0 0 0 y✓ 12C-0sw ` 0.091 s- 2.55 _ 2.18 _ 404 363 926 - 794 _. 291 201 _ _ 742 _ _ 636 11 -!—G_ 4A5-2om- -------_—__-0.770 .s_, _ _21.56 ---19.31..__.- .41...-- __ 82 -- - _880.------ .788 -.__0 — ____ -0-----_-__0._-- _-- .0 Vj✓ 12C-0sw 0.091 w 2.55 2.18 432 321 819 702 432 321 819 702 1A-c1om 1.270 w 35.56 91.12 90 0 3200 8201 90 0 3200 8201 i�—Gp 11 DO _ , . 0.390 w 10 92 11.3 21 21 229. 238 21 238 C_ __ _ 16D-30td _- . _. _._ _ _ _. ._-_0.032 , ... -_ .,-_-0.90, , - - 1.04 _ _ 1618 _ _ _ 1618, - - _-_ 1450 _,,, _ - _ 1.6.83 ...... _ 1330 , _ - .21 ._ ._ _ 1330 _ _229 ,_- __ 1192 _ __ _ ___1383 F -. _. 22A_tpl _ _ _ LL_ ,-. - -, _ _ ..- 0.989 _-- _ 27.69 _0.00 - ., 1618 _ _ _ - 178 4929 - 0 - _ 1330 _,_.• _- 130 , _ _3600 .- _-. _0 - - - ------- s 6 c) AED excursion 3446 3504 Envelope loss/gain 14679 17917 11052 15752 12 a) Infiltration 2964 836 2165 610 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 4 920 Appliances/other 4000 2000 Subtotal (lines 6 to 13) 17643 24133 13217 19282 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17643 24133 13217 19282 15 Duct loads 32% 17% 5646 4223 32% 17% 4230 3374 Total room load 23289 28356T 17447 22657 Air required (cfm) 1367 1367 1 1024 1092 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft� 2018-Apr-02 15:52:22 Right -Suite® Universal 2017 17.0.14� RSU081 01 Page 1 '4aC�` C:\Users\Quick Calcs\Documents\BOWMAN ADDITION.rup Calc = MJ8 Front Door faces: W f r i . +- wrightsoft° Right-J® Worksheet Job: Entire House Date: , QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALC3@/1OL.COM 1 Room name NEW KITCHEN/DIN. 2 Exposed wall 48.0 ft 3 Room height 9.4 ft heaticool 4 Room dimensions 24.0 x 12.0 ft 5 Room area 288.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuh/W-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W _ _. 12C,Osw — _,_ _ _-_ w_0 091 _ _ n. _ 2.55 - _ 2 18 -- _ - 113'_ _113 _ __ ___" _____.287 __ - ___246 , _ ____ _ - - - __ y✓ 12C-Osw 0.091 a 2.55 2.18 226 220 560 480 _ _C 4A572om _ -_ _ _ _ 0 7/0 e 42.10 6 1 129 253 yJ • _ 12C-Osw' _ 0 O91 _ 's _21.56 2.55 ____2_.18 113 72 _- 183 _ _ 157 -- - 11 _�—G_ 4A5 2om__.__ _. _ _ 0 770 --_ 21.56 19.31! .41 41 ,__ 788--- V�l' I�Gp 12C-Osw 1A-c1om 0.091 1.270 . _s__ w w 2.55 35.56 _. 2.18 91.12 _ 0 0 _,_ _. 0 0 _-880 0 0 _ 0 0 11D0- OMO w_ 10.9.2 0. 0 _._ C:_._�_.15D-30td_ - __ .__ - .._ 0.032---_--__- _ 0.90 _. .11.31 _104:.--___._286'.",,.._.288..___�258 - ---0 _.__0._.- - - ------------ -_0.989 _. - . 27.66 _-0.00 __. _. _ 286 48- _. _ _ 1329_ .- — _ --- 0 6 c) AED eXcursion -58 Envelope loss/gain 3627 2165 12 a) Infiltration 799 225 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 2 460 Appliances/other 2000 Subtotal (lines Q.to 13) 4426 4851 Lt ss external load 0 0 'Lass transfer 0 0 redistribution 0 0 14 Subtotal 4426 4851 15 Duct loads 32% 17% 1416 849 Total room load 5842 5700 Air required (cfm) '143 275 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsoft" 2018-Apr-02 16:52:22 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 C:\Users\Quick Calcs\Documents\BOWMAN ADDITION.rup Cale = MJ8 Front Door faces: W k -�- wrightsoft° Duct System Summary Dae. Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM For: BOWMAN ADDITION 5710 BIRCH DRIVE, FT. PIERCE, FL Heating Cooling External static pressure 0.08 in H2O 0.08 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.08 in H2O 0.08 in H2O Supply / return available pressure 0.040 / 0.040 in H2O 0.040 / 0.040 in H2O Lowest friction rate 1.000 in/ 100ft 1.000 in/100ft Actual air flow 1367 cfm 1367 cfm Total effective length (TEL) 131 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk EXISTING HOUSE-E c 22657 1024 1092 1.000 15.0 OxO VIFx 0 0 NEW KITCHEN/DIN. h 2921 171 137 1.000 6.0 Ox0 VIFx 15.1 115.0 st1 NEW KITCHEN/DIN':-A h 2921 171 137 1.000 6.0 Ox0 VIFx 15.9 115.0 st1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 343 275 1.000 776 9.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO. 1367 1367 0 0 0 0 Ox 0 VIFx A— wri htsofta 2018-Apr-0215:62:22 �. � 9 Right -Suite® Universal 2017 17.0.14. RSU08101 Page 1 ACC• C:\Users�Quick Calcs\Documents\BOWMAN ADDITION.rup Calc = MJ8 Front Door faces: W