HomeMy WebLinkAboutNOAs TRINI1y I ERD EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 SCOPE: This Evaluation Report is issued under Rule 61G20-3 at construction materials in the State of Florida. The docur P.E. for use of the product under the Florida Building products described herein have been evaluated for co sections noted herein. DESCRIPTION: TRI=BUILT Roof-Underlayments LABELING: Labeling shall be in accordance with the herein. CONTINUED COMPLIANCE: This Evaluation Report is valid unt Quality Assurance documentation changes, or provisions i this Evaluation Report by the named client constitutes changes or the referenced Quality Assurance documental Evaluation Report relative to updated Code requirements ADVERTISEMENT: The Evaluation Report number preceded advertising literature. If any portion of the Evaluation Rer lOtl� EXTERIOR RESEARCH & DESIGN, LLC. �t Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report A42960.10.12-R6 FL16048-R6 Date of Issuance:10/25/2012 Revision 6: 09/25/2017 the applicable rules and regulations governing the use of ntation submitted has been reviewed by Robert Nieminen, :ode and Florida Building Code, Residential Volume. The pliance with the 6th Edition (2017) Florida Building Code irements the Accredited Quality Assurance Agency noted such time as the named product(s) changes, the referenced f the Code that relate to the product change. Acceptance of agreement to notify Robert Nieminen, P.E. if the product on changes. Trinity) ERD requires a complete review of this vith each Code Cycle. by the words "Trinity IERD Evaluated" may be displayed in )rt is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation 'Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 FILt COPY The facsimile seal appearing was authorized by Robert Nieminen, P.E. on09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retail d :ONCEALED FWUNWA�IA�rti THESE PLANS AND ALL PROPOSED WORK ST. LUC►IE COUNTY BUILD _ . ION ARE SUBJECT TO ANY CORRECTIONS REVIEWED FOR COMP ARE THE RESPONSIBIL" OF THE REQUIRED BY FIELD INSPECTORS'THAT REVIIE D Y CONTRACTOR OF RECORD DATE MAY BE NECESSARY IN ORDER TO PLANS AND PERMIT ST BE KEPT ON JOB COMPLY WITH AU APPUICABUE CODES. OR NO INSPECTION WILL BE MADE. 11 ''. 0r ', . ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Sub -Category: Compliance Statement: ' demonstrated compliance in accordance with the foil Conditions of Use set forth 2. STANDARDS: Section 1504.3.1 1504.3.1 1504.6 1507.2.4 / 1507.1.1, 1507.2.9.; 1507.3.3 3. REFERENCES: Entity ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD(TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) UL, LLC. (QUA9625) UL, LLC. (QUA9625) 4. e- tPRODUCT DESCRIPTION:,, a`p 4.1 Txi=Built' Sand -It, modified bitu y � O TRINITY I ERD Roofing Underlayment -BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have :h the following sections of the 6th Edition (2017) Florida Building Code through testing ing Standards. Compliance is subject to the Installation Requirements and Limitations / Property Wind Resistance Wind Uplift Accelerated Weathering Physical Properties Physical Properties Examination Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Accelerated Weathering Wind Resistance Quality Control Quality Control Standard FM 4474 UL 1897 ASTM G155 ASTM D1970 FRSA/TRI April 2012 (04-12) Reference S40540.02.13-1 S40540.11.13 S40540.03.14 S44870.04.14-2 S44870.04.14-3 S44870.04.14-1 S44870.04.14-4 S43530.02.14-1-R1 S43530.05.14 S40540.10.14 SC7645.02.15 SC8520.04.15 SC14045.05.17-R1 Multiple -Listing R16814 Service Confirmation Year 2011 2012 2005 2015 2012 Date 02/19/2013 11/19/2013 03/26/2014 04/02/2014 04/02/2014 04/10/2014 04/10/2014 05/14/2014 05/28/2014 10/31/2014 02/13/2015 05/27/2015 06/07/2017 12/10/2015 Exp. 07/18/2020 SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS i roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.2 Tri-Built S/A HTiTU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment, meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smoot )t HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in F.BC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. _ 7 '1:4i(N..•aiF}`i�•'i�": .4w.i}�r)f1.^b �:iw�itl :,}C-3' ^,y S;4_, i:• ;! .. ., ��'. � ..' .i. �. Exterior Research and Design pLLC Evaluation Report A42960.10.12-R6 lC :i TH i Certificate of Authorization#9503 6 EDITION(2017)FACNON, HVHZ,EVALUATION ;r i i ;; y FL16048=R6, 4 t s" .. o l + + ' ; • ° r ° S { TRI-BUILT Roof iUnderlayinents; (800) 51641485' ' "t ,h Revision 6: 09/25/2017 Si' i! ,.. i '} •iz,rt `?s.. _ g. S' fn.'''iy l=,i"•il'�, ,I`=1sE'.? ! Page 2of6 ;. R `J TRIN['jY I ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLEA": ROOF COVER OPTIONS Underlayment Asphalt ` < a k Nail -On Tile Foam -On Tile Metal Wood Shakes Slate Shingles &Shingles ITr,-Bu11t_SandNR`SA 5 h I h g I eI Unde lla_ym nt Yes No No No Yes Yes Tri-Built S/A HT TU Yes Underlayment Yes Yes See 5.5.1 Yes Yes Yes Tri-Built Smooth HT S/A Underlayment Yes No No Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE lA: ALLOWgBCE TILE ADHESIVE%,UNDERLAYMENT COMBINATIONS) , Adhesive Florida Product Approval Underlayments ICP Adhesives Polyset® AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBond'"' FL22525 I Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; primed Southern Yellow Pine; ASTM D4: While not required over plywood, OSB or So recommends priming the deck if the final r TRI-BUILT Materials Group, LLC requires tc OSB prior to installation of the self -adhering 5.6.2 Bond -to -Insulation: ilt S/A HT TU Underlayment or Tri-Built Smooth HT S/A ;B; ASTM D41.primed OSB; Southern. Yellow Pine; ASTM D41 primed structural concrete. thern Yellow Pine substrates, TRI-BUILT Materials Group, LLC of cover is not slated for installation within 24 hours. Note: Igue-and-groove board decking be covered with plywood or Inderlayment. Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix J. ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-RG TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/2S/2017 Page 3 of 6 5.6.3 5.6.4 #1 #2 1 \-­,]TR1.N1TY1ERD Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226, Tye I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind pressures. Maximum Design) Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered. #3 Maximum Desia Deck: Deck Preparatio Primer: Underlayment: #4 Maximum Desia Deck: Base Sheet: Underlayment: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. is Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. (Optional) RESISTO EXTERIOR PRIMER Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Tri-Built S/A HT TU Underlayment, self -adhered. Exterior Research and Design, U.C. Evaluation Report A42960.10.12-116 Certificate of Authorization #9503 6T" EDITION.(2017) FBC NON-HVHZ EVALUATION F1.16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 4 of 6 'TRINIIY. I ERD' 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS' ,:• ` Maximum Underlayment Tile Profile I Staging Method Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) 1 c Tri-Built S/A HTTU Underlayment Lugged Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-116 Certificate of Authorization #9503 6T" EDITION (2017) FBC.NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 5 of 6 6. INSTALLATION: 6.1 TRI-BUILT Roof published instal specifics noted k 6.2 Re -fasten any Ic to remove any d �.J I RINITY ,' ERD layments shall be installed in accordance with TRI-BUILT Materials Group, LLC requirements subject to the Limitations set forth in Section 5 herein and the decking panels, and check for protruding nail heads. Sweep the substrate thoroughly and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: 6.3.3 While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. I Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the expos Ied part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. I Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at t i e top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile lapplications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. ISee Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIR As required by the Buildi this product. 8. MANUFACTURING Gulfport, MS 9. QUALITY ASSURANCE UL, LLC —QUA9625; Official or Authority Having Jurisdiction in order to properly evaluate the installation of 578-3406; k.chancellor@us.ul.com -END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 6 of 6 CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: Manufacturing Plants: Quality Assurance: SCOPE TjTAMKO7BUIL"DING-PRDDU 220-West-41"—Street----`ri Joplin, MO 64801 (417) 624-6644 Joplin, MO Phillipsburg, KS Frederick, MD Dallas, TX Tuscaloosa, AL UL LLC (QUA9625) Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, 6T" EDITION (2017) Issued September 25, 2017 Category: Roofing Subcategory: Asp 04"1 ItShin1,gles Code Sections: 1-5, 1507:2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-064-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-131-02-01 TAS 100 -1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-31i4-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies (TST5878) TAP-317-02-01 TAS 100 1995 UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (TST9628) 04NK24366 ASTM D 3462 2010A UL LLC (TST9628) 05NK28I006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC (TST9628) 061\11<03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 08CA59132 ASTM D 3161 2016 UL LLC (TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 10CA50498 ASTM D 3462 2010A UL LLC (TST9628) 1OCA64882 ASTM D 3161 2016 UL LLC (TST9628) I INK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 12CA24551 ASTM D 3161 2016 UL LLC (TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC (TST9628) 4787043752 ASTM D 3161 2016 UL LLC (TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC (ANE11669) TBP150d1.3 Calculations 2017 TBP15001.4 FL18355-R4 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GD TAMKO BUILDING PRODUCTS rj K Asphalt Shingles TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION Elite Glass -Seal® 12-'1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass -Seal 12I 1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ciramic granules complying with ASTM D 3462. Glass -Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt_ shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Heritage® I 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin, Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Herita e® Premium 9 1I -1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg & complying with ASTM D 3462. Tuscaloosa) Heritage® Premium 1I2" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Vintage® 1I7-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Woodgate 112" x 36-3/8", ASTM D 316.1, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage® Hip and Ridge (Phillipsburg) TBP15001.4 This evaluation report is provi Technical Services, LLC of ar This evaluation report does n specifically addressed herein. 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle surfaced with mineral granules complying with ASTM D 3462. FL18355-R4 Page 2 of 11 :d for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK product changes or quality assurance changes throughout the duration for which this report is valid. express nor imply warranty, installation, recommended use, or other product attributes that are not I � TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERVICES, L-LC INSTALLATION Elite Glass -Seal® (Frederick, Joplin & Tuscaloosa) Glass -Seal (Frederick, Joplin (Non- HVHZ) & Tuscaloosa) Nailing Area. Nailing Area Basic Wind Speed (V it): IMax. 194 mph Basic Wind Speed (Vasa): Max. 150 mph Deck (HVHZ): jin accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed I I elow. Installation (Non-HVHZ): lestalled with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. 1" 1n Figure 1. Elite Glas 4 Nail Pattern (N EW Edge & Glass -Seal i'HZ only) 1i� Butt Edges Figure 2. Elite Glass -Seal & Glass -Seal 6 Nail Pattern 6-7/8" TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assuranceichanges throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Heritage@ Basic Wind Speed (V it): (Dallas, Frederick, Joplin, Basic Wind Speed (Vasa): Phillipsburg & Tuscaloosa) Deck (HVHZ): Heritage@ Premium (Dallas, Frederick Phillipsburg & Tuscaloosa) Deck (Non-HVHZ): Heritage@ Woodgate (Dallas & Frederick) Underlayment: Min. slope: InILlIation HVHZ : Installation (Non-HVHZ): I V I Figure 3. H 1" TBP15001.4 TAMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. FASTENERS` ` NAILZONE COMMON BOND EXPOSURE 6-68" /211►h-12-3/,8" 12-112'"� h-1" a®, Heritage® Premium, and Heritage® Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERSzl!;��:�14OND NAILZONE OMMON 1 1. 1 l EXPOSURE 5-5/8" 7-1I2"-i►�it- 7�3I8'.�- 7-1 f2"-M�'h-7-1/2'� �4-1 " Figure 4. Heritage® & Heritage® Premium 6 Nail Pattern FL18355-R4 4of11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i ' I CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC i,BONO 6=178" � �ExPOSURE 5;51$"' . 1 -112, ' 7-1/2' ' ► ,7-318„ 1 /2 711 Ij.• i ,. �Figure 5. Heritage® Woodgate 6 Nail Pattern -►I1"11" 14-12.1/2" 1 412-1 %2"- 1•'11"14- , l i I 4 i ®Common Band (.� FASTENERS i \t co T 00 39-3/8' Figure 6. Heritage®, Heritage® PF'emium, & Heritage® Woodgate Alternate 6 Nail Pattern PAINT LINEN 7=7I8" 6-1I8"� :PREFERRED' FASTENER! .LWATIQN Figure 7. Heritage® (Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warrant y, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Premium Basic Wind Speed (V,,ii): Max. 194 mph (Frederick) Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation (HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. NAIL ZONE/ 'COMMON BOND' 51/2" JIJ EXPOSURE 5" 1 �,� � 1'.1 "-►�-- 12" Figure 8. Heritage® Premium (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONFJ COMMON BOND 51iv D .0 - EXPO RE S." I VLt TBP15001.4 This evaluation report is provi Technical Services, LLC of ar This evaluation report does n specifically addressed herein. 4 , . 3 9"—+91h : li-1 11 Figure 9. Heritage@ Premium (Frederick) 6 Nail Pattern FL18355-R4 Page 6 of 11 !d for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK product changes or quality assurance changes throughout the duration for which this report is valid. express nor imply warranty, installation, recommended use, or other product attributes that are not CREEK TECHNICAL SERVICES, LLC Heritage@ Woodgate Basic Wind Speed (V„it): (Frederick) Basic Wind Speed (Vnd): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (Non-HVHZ): TAMKO BUILDING PRODUCTS Asphalt Shingles it iMax. 194 mph 'Max. 150 mph JIn accordance with FBC requirements; IS lidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. linstalied with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. BOND 5.1./�2" I ! 11 � I, EXPOSURE ( i Figure 10. Heritage® Woodgate (Frederick) 4 Nail Pattern (non-HVHZ only) NAIL ZONE: COMMON BOND' lQ(POS,;RE-5" Figure 11. Heritage® Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation; recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Vintage® Basic Wind Speed (Vint): (Phillipsburg) Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ): UIYderla ment: Min. slope: I Lallation HVHZ : II nstallation (Non-HVHZ): s T re TBP15001.4 This evaluation report is prc Technical Services, LLC of This evaluation report does specifically addressed here! M� -20MM2031=301 Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "5 Nail Pattern" or "6 Nail Pattern" detailed below. r 15" Figure 12. Heritage® Vintage® 5 Nail Pattern (non-HVHZ only) Figure 13. Heritage® Vintage® 6 Nail Pattern 17.1?2" luposure • Notch Ev— /Nouft 17-IM FL18355-R4 Page 8 of 11 id for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK product changes or quality assurance changes throughout the duration for which this report is valid. express nor imply warranty, installation, recommended use, or other product attributes that are not 1 CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC i Hip & Ridge Basic Wind Speed (Vuit): Max. 194 mph (Frederick & Joplin) Basic Wind Speed Msd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing i Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for rlew construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation: I, stalled with 5-1/8 inch exposure in accordance with the IBC and manufacturer's published installation instructions. direction of the exposed end shall be away from the The p evailing wind. Direction of prevailing 'posure Figure I �5-1/8exposure SAW', 1of I ,If" 1" Fastener. Faster Figure 2 1�4r� Figure 3 Figure 14. Hip & Ridge (Frederick & Joplin) TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurbnce changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation; recommended use, or other product attributes that are riot specifically addressed herein. CREEK TECHNICAL SERV Vintage® Hip & Ridge (Phillipsburg) TBP15001.4 This evaluation report is prc Technical Services, LLC of This evaluation report does specifically addressed herei TAMKO BUILDING PRODUCTS Asphalt Shingles LL.0 Wind Speed (V„it): Max. 194 mph Wind Speed (V,,d): Max. 150 mph (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. 0S13 existing construction. ;rlayment: In accordance with FBC requirements. slope: 2:12 and in accordance with FBC requirements. Ilation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. of prevailing wind exposure Figure 1 1" } Fastener �5-1/2" IFigure 2 Icposure rigure s Figure 15. Vintage® Hip & Ridge (Phillipsburg) FL18355-R4 Page 10 of 11 ed for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK product changes or quality assurance changes throughout the duration for which this report is valid. t express nor imply warranty, installation, recommended use, or other product attributes that are not r `) i CREEKTAMKO BUILDING PRODUCTS [1 Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave inl horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6`h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. %%���PRY ��•tiPG•\'�GENSF•5�� No 74021 I • X X o STATE OF : 44/� E�r.% CERTIFICATION OF INDEPENDENCE 2017.09.25 i 11:31:41 .. ..YyWy YMgIW,0.•M1,1 - .. .. .. 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE11669 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. i CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. i Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. (-)o \,l TRINITY (ERD EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and construction materials in the State of Florida. The docume P.E. for use of the product under the Florida Building Co compliance with the 6eh Edition (2017) Florida Building Coc DESCRIPTION: TRI-BUILT Mod1 lef d-Bitumen-Roof-Systems EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203)262-9245 Evaluation Report A42970.10.12-112 FL16027-R2 Date of Issuance:10/23/2012 Revision 2: 09/25/2017 applicable rules and regulations governing the use of on submitted has been reviewed by Robert Nieminen, The product described herein has been evaluated for sections noted herein. LABELING: Labeling shall be in accordance with the requirl ments the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of t i e Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentationlchanges. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by tre words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 261,page Appendix. Prepared by: !� �' TC? •3?4'?4 5 Robert J.M. Nieminen P.E. • a r' , F' �,—,. The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No. 59166, Florida DCA ANE1983 �'�•,uat�a`�' P.E. on 09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: + 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ul� ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Sub -Category: Compliance Statement: LLC, have demonstrated through testing in accorc and Limitations / Conditii (TRINITY I ERD Roofing Modified Bitumen Roof Systems tl-BUILT Modified Bitumen Roof Systems, as produced by TRI-BUILT Materials Group, impliance with the following sections of the 6th Edition (2017) Florida Building Code ce with the following Standards. Compliance is subject to the Installation Requirements of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470,4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-111 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) Physical Properties P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867)� FM 4470 3006646 01/04/2000 FM Approvals(TST18671 FM 4470 3001334 01/25/2000 FM Approvals(TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals(TST1867) FM 4470 3006115 05/02/2001 FM Approvals(TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals(TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST186i7) FM 4470 3020703 07/30/2004 FM Approvals(TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals(TST18617) FM 4470/4474 3024594 05/23/2006 Exterior Research and Design, I.I.C. Evaluation Report A42970.10.12-R2 Certificate ofAuthoriration #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-R2 I TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 2 of 4 �TRINITYJERD Entity Examination Reference Date FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals(TST1867) FM 4470/4474 I 3030668 09/12/2007 FM Approvals(TST1867) FM 4470/4474 I 3032172 06/12/2009 PRI(TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI(TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 UL LLC (QUA9625) Quality Control MI -Agreement 02/27/2012 UL LLC (QUA9625) Quality Control ML Correlation, R27202 08/20/2012 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp. 10/06/2018 4. PRODUCT DESCRIPTION: This Evaluation Report covers TRI-BUILT Modified Bitumen Roof Systems installed in accordance with TRI-BUILT Materials Group, LLC published installation instructilons and the Limitations / Conditions of Use herein. The following membranes make up the subject systems. Table 1: Roll -Goods for TRI-BUILT Modified, Bitumen Roof:Systems ' Type Product I Specification Reference Grade Type SBS Membranes TriBuilt SA SBS Base ASTM D6163, Table 2 S I TriBuilt SBS Granular ASTM D6164 G I TriBuilt SA SBS Cap ASTM D6164 G I APP Membranes TriBuilt APP Smooth ASTM D6222 S I TriBuilt APP Granular ASTM D6222 G I TriBuilt SA APP Cap ASTM D6222 G I LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 5.3 5.4 5.5 This Evaluation Report is not for use in FBC HVHZ Refer to a current Approved Roofing Materials Di ns. for fire ratings of this product. For steel deck installations, foam plastic insulation lshall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. The roof system evaluation herein pertains tc members shall be in accordance with FBC I Jurisdiction. Load resistance of the roof deck Approval documentation. -deck roof components. Roof decks and structural ments to the satisfaction of the Authority Having be documented through proper codified and/or FBC 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone,2/3 enhancements. Exterior Research and Design, U.C. Evaluation Report A42970.10.12-R2 Certificate of Authorization #9503 6Tx EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 3 of 4 7- 5.8 For assemblies wi assembly shall me rational analysis is �J I RINITY ERD :hl all components fully bonded in place, the maximum design pressure for the selected et or exceed critical design pressure determined in accordance with FBC Chapter 16. No permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insular existing deck or eN any surface condil with ANSI/SPRI IA 124 shall be condu 5.11 For bonded insuk system shall be c Authority Having J Loss Prevention DI 5.12 Metal edge attach FBC Chapter 16 an RAS 111, except 1609.3(3). 5.13 All products in the 6. INSTALLATION: ion or membrane over existing substrates in a re -roof (tear off) or recover installation, the i�sting roof surface shall be examined for compatibility with the adhesive to be installed. If ions exist that bring system performance into question, field uplift testing in accordance 11, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS cted on mock-ups of the proposed new roof assembly. tion or membrane over existing substrates in a recover installation, the existing roof Ipable of resisting project design pressures on its own merit to the satisfaction of the irisdiction, as documented through field uplift testing in accordance with ASTM E907, FM ita Sheet 1-52 or Testing Application Standard TAS 124. merit (except gutters), shall be designed and installed for wind loads in accordance with J tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6.1 TRI-BUILT Modified Bitumen Roof Systems shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer tlo FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING Contact the noted requirements. 9. QUALITY ASSURANCE U L LLC — QUA9625; ( - TH agency for information on product locations covered for F.A.C. Rule 61G20-3 QA 578-3406, k.chancellor@us.ul.com PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42970.10.12-112 Certificate ofAuthorization #9503 6TM EDITION (2017) FBC NON.HVHZ EVALUATION FL16027-RZ TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 4 of 4 �JTRINITYJ ERD DIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1E-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 11' Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 8 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 213 Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 / 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 30 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 36 Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 413 LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded -Roof _Cover -----_ 21 5C CWF New, Reroof (Tear -Off) or Recover — B _ Mech.-Attached-BaYe Insulation, Bonded Top Insulation, Bonded Roof Cover 22 5D CWF New, Reroof (Tea(Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization #9503 6i" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26 C)o J 1 FZINITY I ERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢-HA-(HA): Full coverage at 25-30 Ibs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive (D=15): Continuous_0.75 to 1-inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to h0 55 iwcni de ribbons,-12=inch-o:c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). NotOlyBonde. Not Green maybe used where-O/y8ond-500 is re erenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya nu rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (013500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carrythe limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26 C)o \i TRINITY I ERD 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE I: TRI-BUILT ROOF COVERS Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type II (Base and Ply sheets, Asphalt -Applied) HA at 20 40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40 Ibs/square (SBS, Asphalt -Applied) SBS-TA Cap Ply TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base Ply TriBuilt SA SBS Base (SBS, Self -Adhering) Self -Adhering Cap Ply TriBuilt SA SBS Cap APP-TA Base Ply or Ply TriBuilt APP Smooth (APP, Torch -Applied) Torch -Applied Cap Ply TriBuilt APP Smooth, TriBuilt APP Granular APP-SA Cap Ply TriBuilt SA APP Cap Self -Adhering (APP, Self -Adhering) 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) - Type-- -- Attach VB-1. ASTM D41 TriBuilt SA SBS Base Self -Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Insta-Stik, 12-inch o.c. -75.0 VB-3. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 VB-4. ASTM D41 TriBuilt SA SBS Cap Self -Adhering CR-20, 12-inch o.c. -270.0 VB-5. ASTM D41 TriBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0 17. Dens Deck shall be field -primed with PG300 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization H9503 6TR EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26 �I TRINITY (ERD TAB - LE 1A-1 WOOD DECKS' NEW CONSTRUCTION OR REROOF{Tenn-OFF) ,SYSTEM TYPE A 2:, MECHANICALLYATTACHEO'ANCHOR SHEET; BONDED`INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 0.25-inch Dens Polyglass G2 Base, 8-inch o.c. in 4- Deck, Dens Deck Prime, Min. 19/32- --�CertainTeedGlasbase,,- 32 ga., 1-5/8- -� inch lap and 8- (Optional) FBC SECUROCK Gypsum- inch plywood Firestone MB Base, JM inch diameter _. inch -inch -in -Approved, Fiber Roof Board, Min. -075-inch-inch— (Optional) SBS-AA, W 1 max. Tamko tin caps with 11 three, equally ASTM C3289, H� -HA gp_AA BP_ SBS-TA, -60.0 inchspans in spans Glass BPerma-ase Glass Base or or a annular ringspaced, g ' p a II of lso- type p y (homogeneous) or min. ( g ) — -APP-TA— GAFGLAS #75 shank nails staggered cyanurate 0.5-inch Structodek center rows High Density Fiberboard Roof Insulation Polyglass G2 Base, 8-inch o.c. in 4- Min. 19/32- CertainTeed Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC Min. 0.25-inch Dens (Optional) SBS-SA, inch plywood Firestone MB Base, JM inch diameter inch o.c. in Approved, Deck, Dens Deck Prime, One or APP-SA, W 2 at max. 24- Perma-Ply 28, Tamko tin caps with it three, equally ASTM C1289, HA SECUROCK Gypsum- HA SBS-SA more SBS- SBS-TA or -60.0 inch spans Glass Base or ga. annular ring spaced, type II polyiso- Fiber Roof Board SA or APP-TA GAFGLAS #75 shank nails staggered cyanurate APP-TA center rows 6-inch o.c. in 4- Min. 2-inch D-IS, OB500, Min. 19/32- 32 ga., 1-5/8- inch lap and 6- ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D-IS, inch plywood Polyglass Elastobase inch diameter inch o.c. in H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, (Optional) SBS-AA, W-3 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP -AA BP -AA SBS-TA, -60.0* inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch Fiber Roof Board M-OSFA APP-TA shank nails staggered center rows or ENRGY-3 oc 6-inch o.c. in 4- Min. 2-inch D-IS, OB500, Min. 19/32- 32 ga., 1-5/8- inch lap and 6- , ACFoam IIIII, CR-20 or M- D-IS, (Optional) SBS-SA, inch plywood Polyglass Elastobase inch diameter inch o.c. in H-Shield, H- OSFA, atop (Optional) Additional OB500, One or APP-SA, W-4 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener layers of base insulation CR-20 or SBS-SA more SBS- SBS-TA or -60.0* inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch M-OSFA SA or APP-TA shank nails staggered or ENRGY-3 oc APP-TA center rows Exterior Research and Design, LLC. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL36027-R2 Revision 2: 09/25/2017 Appendix 1, Page 4 of 26 �f 1 RINITY ERD TABLE 1A-2: WOOD;DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) oR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED'ROOF"COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psfl 12-inch o.c. in 4- Min. 0.25-inch Dens Deck, Min. 19/32- Polyglass OMG Flat inch lap and 12- (Optional) FBC Dens Deck Prime, SECU ROCK inch plywood Elastobase or Bottom Plates inch in two, Approved, Gypsum -Fiber Roof Board, (Optional) SBS-AA, SBS- W-5 max. Polyglass (square) with equallyspaced, ASTM C1289, HA Min. 0.75-inch FescoBoard HA BP -AA BP -AA TA, APP-TA -60.0 in inspans spans Elastobase Roofgrip #12 staggered center type II polyiso- (homogeneous) or min. 0.5- Poly cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Polyglass 12-inch o.c. in 4- (Optional) FBC (Optional) Min. 19/32- OMG Flat inch lap and 12- inch plywood Elastobase or Bottom Plates inch o.c. in two, Approved, Min. 0.25-inch Dens Deck, One or SBS-SA, APP- W 6 at max. 24- Polyglass (square) with equally spaced, ASTM C1289, HA Dens Deck Prime, SECUROCK HA SBS-SA more SBS- SA, SBS-TA -60.0 inch spans Elastobase Roofgrip #12 staggered center type II polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA Poly cyanurate TA rows TABLE 16: WOOD DECKS -NEW CONSTRUCTION; REROOF (TEAR -OFF) OR RECOVER _ — SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,.BONDEDTOP INSULATION, BONDED"f;00E-COVER— System Base Insulation Layer — Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) _ Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (Psfl Min. 19/32-inch Min. 1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if (Optional if using W-7 plywood at max. 24-inch ENRGY 3, H-Shield Dekfast #12 or TruFast 1 per x (homogeneous) or min. 0.5 -inch HA using AA Ply) AA Base) One or SBS -AA, SBS-TA, -60.0 spans or Polytherm MP-3 with TruFast DP 1.33 ft Structodek High Density Fiberboard BP AA more BP -AA or APP-TA Roof Insulation APP-TA Exterior Research and Design, LLC. d/b/a Trinity)ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 0 EDITION (2017) FBC NON-HVH2 EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL36027-R2 Revision 2: 09/25/2017 Appendix 1, Page 5 of 26 \I TRINITY J ERD - TABLE,IC °WOOD DECKS -NEW CONSTRUCTION; REROOF (TI?AR-OFF) oR RECOVER ` SYSTEM TYPE C MECHANICALLY -ATTACHED INSULATION; BONDED'ROOF COVER F ; System Deck (Note 1) Base Insulation Top Insulation Layer Roof Cover (Note 15) MOP Type Fasteners Attach Base Ply Ply Cap Ply No. Layer (Psf) Min. 19/32-inch (Optional) Min. 0.5-inch Structodek High Density Dekfast Galvalume (Optional if (Optional if using AA W-8 plywood -at -max— One or more layers, Fiberboard Roof Insulation or min. 0.25- Steel Hex with 1 per 1.33 SBS-AA, SBS-TA, APP- -82.5 24-inch spans any combination— -inch-Dens Deck, �— Dens Deck Prime or Dekfast #12 DP ft BP -AA or APP-TA TA loose laid SECUROCK Gypsum -Fiber Roof Board—!_ (Optional) Dekfast Galvalume —� W-9 Min. 19/32-inch plywood at max. One or more layers, Min. 1.5-inch ENRGY 3, H-Shield or Steel Hex with Dekfast #12 DP or 1 perZ .33 SBS-SA (Optional) One or more SBS-SA, APP-SA, SBS- 82 5 24-inch spans any combination, Polytherm TruFast MP-3 with ft SBS-SA or APP TA TA or APP-TA loose laid TruFast DP TABLE 1D WOOD DECKS NEW CONSTRUCTION; REROOF (TeAa-OFF) oe RECOVER r SYSTEM TYPED: PRELIMINARILYATTACHED;INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF,C_ _OVER: ; System Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (Psf) Polyglass Elastobase, Polyglass OMG Flat Bottom Plates Min. 19/32-inch Elastobase Poly, Polyglass G2 Base, (square) with Roofgrip 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, W-10 plywood at max. One or more layers, Prelim. CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -52.5 24-inch spans any combination Attached Base, JM Perma-Ply 28, Tamko Glass Dekfast #14 or TruFast staggered center rows or APP-TA APP-TA Base or GAFGLAS #75 MP-3 with TruFast HD Min. 19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast 12-inch o.c. in 4-inch land 12- One or more SBS-SA, APP-SA W-11 plywood at max. any combination Attached Elastobase Poly with poly top surface #14 or TruFast MP-3 with inch o.c. in two, equally spaced, SBS-SA ,ap SBS-TA or 24-inch spans TruFast HD staggered center rows APP-TA Min. 19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, W-12 plywood at max. any combination Attached Elastobase Poly (square) with Roofgrip #12 inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -60.0 24-inch spans staggered center rows or APP-TA APP-TA Min. 19/32-inch 12-inch o.c. in 4-inch lap and 12- SBS-SA, One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates One or more APP-SA, W-13 plywood at max. any combination Attached Elastobase Poly with poly top surface (square) with Roofgrip #12 inch o.c. in two, equally spaced, SBS-SA SBS-TA or -60.0* 24-inch spans staggered center rows APP-TA Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report A42970.30.12-R2 for F1.16027-112 Certificate of Authorization #9503 O EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 6 of 26 �PTRRINITYJERD TABLE 1E-1; WOOD DECKS -NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Psf) W-14 Min.15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA 45.0' inch spans equally spaced, staggered center rows APP-TA or APP-TA W-15 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA -52.5 inch spans equally spaced, staggered center rows APP-TA or APP-TA Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase (Optional) One or W-16 plywood at max. Poly, Polyglass G2 Base, CertainTeed 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, more BP -AA or SBS-AA, SBS- -60.0 24-inch spans Glasbase, Firestone MB Base, JM Perma- with 11 ga. annular ring shank nails equally spaced, staggered center rows APP-TA TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS #75 Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, One or SBS-SA, APP- W-17 ly plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank nails equally spaced, staggered center rows more S(Optional) BS-SA or moreAPP- SA, SBS-TA or -60.0 24-inch spans APP-TA W-18 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two, (Optional) BP -AA or SBS-AA, SB5-TA -90.0 inch spans equally spaced, staggered center rows APP-TA or APP TA Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 4-inch o.c. in 4-inch lap and 4-inch o.c. in four,_ _ (Optional) One or _ --- _SBS-SA, APP- W-19 plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank nails. _equally-spaced;-staggeed center r ows more SBS-SA or SA, SBS-TA or -97.5 24-inch spans ---- APP-TA APP-TA W-20. Min.15/32-inch plywood at max. 24- - — - — Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and o.c. in three, (Optional) BP -AA or , SBS-TA SBS-Aor -105.0 inch spans enter r equally spaced, staggered center rows APP-TA APP or APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SB5-AA, SBS- W-21 plywood at max. Elastobase Poly with 11 ga. annular ring shank nails equally spaced, staggered center rows more BP -AA or TA, APP-TA -112.5 24-inch spans APP-TA Min. 19/32-inch 32 ga., 1-5/8-inch diameter tin caps SBS-SA, APP- W-22 plywood at max. Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SA, SBS-TA or -112.5 24-inch spans Elastobase Poly with poly top surface Note: Tin caps are to be primed with equally spaced, staggered center rows more APP-TA APP TA ASTM D41 primer. Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 7 of 26 \,�TRINITYJERD TABLE;IE 2.1NOOD DECKS=NEW'CONSTRUCTION; REROOF (Teas -OFF) oa Ri covEa SYSTEM TYPE E: NON-INSULATED,MECHANICALLYATTACHEDBASESHEET,BONDED-ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Psf) --- _Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or W-1 —� plywood at max. _Poly, Polyglass G2 Base, CertainTeed 'Firestone Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or SBS-AA, SBS- -52.5 24-inch spans Glasbase, MB-Base,-JM-Perma- or TruFast-MP-3-with TruFast HD center rows APP-TA TA, APP-TA ply 28, Tamko Glass Base or GAFGLAS #75 Min. 19/32-inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- 12-inch o.c. in 4-inch lap and-12=inch— — One or more-SBS-_ SBS-SA, APP- W-2 plywood at max. Elastobase Poly with poly top surface 3 with Tru Fast HD O.C. in two, equally spaced, staggered SA SA, SBS=TA or— 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c. in two, equally spaced, staggered more BP -AA or TA, APP-TA -60.0 24-inch spans center rows APP-TA Min.19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch One or more SBS- SBS-SA, APP- 4 Ew- plywood at max. Elastobase Poly with poly top surface Roofgrip #12 in two, equally spaced, staggered SA SA, SBS-TA or 60.0 24-inch spans center center rows APP-TA :. oR REw ROOF (TE[► TABLE iF .WOOD DECKS NEW CONSTRUCTIONR: OFF) t SYSTEM TYPE F NON INSULATED, BQNDED3ROOF CODER :Syst m `; - Roof Cover (Note 15) MDP } y Deck Primer (Psf) Joint Treatment _ Base Ply Ply Cap Ply W-'5�aNtli 32 'a A D4 - SB w SoBS=P-ood,r:15 =SA S- STBS-y A �_`90(Optlona)'ASTM 0 mag..2,4 mcfiP"s ns�s � ._ r,_SA T.AAPaP - W 6 Min. 15/32-inch plywood (Optional) ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA 97.5 at max. 24-inch spans SBS Base, rolled into place to create continuous bond. APP-TA or APP-TA Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL36027-112 Certificate of Authorization #9503 6°1 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26 \J TRINITY I ERD TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (pso Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using Grade 33 steel or ACFoam II, ENRGY Dekfast #14, Trufast (homogeneous) or min. 0.5-inch (Optional if using AA Base) One or SBS-AA, SBS- SC-1. min. 2,500 psi 3, H-Shield or MP-3 with Trufast HD or 1 per 2 ftz Structodek High Density HA AA Ply) BP -AA more BP -AA or TA, APP-TA _45.0* structrual concrete Polytherm OMG 3-inch Galy Plate Fiberboard Roof Insulation APP-TA with OMD HD Min. 22 ga., type B. Min. 2-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using SC-2. Grade 33 steel or ACFoam II, ENRGY Dekfast #14, Trufast MP-3 with Trufast HD or 1 per 4 ftz (homogeneous) or min. 0.5-inch HA (Optional if using AA Base) One or SBS-AA, SBS- -45.0* min. 2,500 psi 3, H-Shield or OMG 3-inch Galv Plate Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete Polytherm Fiberboard Roof Insulation APP-TA with OMD HD Min. 22 ga., type B, Min.1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using SC-3. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or TruFast 1 per 1.33 (homogeneous) or min. 0.5-inch HA (Optional if using AA Base) One or SBS-AA, SBS- -90.0 min. 2,500 psi ftz Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete or Polytherm MP-3 with TruFast HD Fiberboard Roof Insulation APP-TA Min. 22 ga., type B, Min. 1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard BP -AA (Top surface One or more SBS-SA, APP- SC-4. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or TruFast 1 per 1.33 z (homogeneous) or min. 0.5-inch HA primed with ASTM layers, SBS-SA or SA, SBS-TA -90.0 min. 2,500 psi or Polytherm MP-3 with TruFast HD ft Structodek High Density D41 primer)- - �-- -APP=TA -- or APP-TA structrual concrete Fiberboard Roof Insulation _; •. - -. -- '-- TABLE 2B; STEEL OR`STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION, RERO. OF (TEAR -OFF) oR RECOVER' SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF.COVER System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Ps6 Type Fasteners Attach Base Ply Ply Cap Ply Min. 22 ga., type B, (Optional) One or (Optional if (Optional if using AA SC-5. Grade 33 steel or more layers, any Min. 0.5-inch SECUROCK Gypsum- OMG 3-inch Galvalume Steel 1 per 1.78 using AA Ply) Base) One or more BP- SBS-AA, SBS- -75.0 min. 2,500 psi combination, loose Fiber Roof Board Plate with OMG #14 HD ftz BP -AA AA or APP-TA TA, APP-TA structrual concrete laid Min. 0.5-inch Structodek High Min. 22 ga., type B, One or more layers, Density Fiberboard Roof Dekfast Galvalume Steel Hex with (Optional if (Optional if using AA SC-6. Grade 33 steel or any combination, Insulation or min. 0.25-inch Dens Dekfast #12 (steel only) or #14 or 1 per 1.33 using AA Ply) Base) One or more BP- SBS-AA, SBS- -82.5 min. 2,500 psi loose laid Deck, Dens Deck Prime or TruFast MP-3 with TruFast DP ftz BP -AA AA or APP-TA TA, APP-TA structrual concrete SECUROCK Gypsum -Fiber Roof (steel only) or HD Board Min. 22 ga., type B, (Optional) Dekfast Galvalume Steel Hex with SBS-AA, SBS- Grade 33 steel or One or more layers, Min. 1.5-inch ENRGY 3, H-Shield Dekfast #12 (steel only) or #14 or 1 per 1.33 (Optional) One or more TA, SBS-SA, SC 7. min. 2,500 psi any combination, or Polytherm Trufast MP-3 with TruFast DP ftz SBS-SA SBS-SA or APP-TA APP-TA, APP- 12.1 structrual concrete loose laid (steel only) or HD SA Exterior Research and Design, LLC. d/b/a Trmity(ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 e EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-112 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 9 of 26 � �i �l TRIIVIIY JERD TABLE2C STEELOR,STRUCTURALCU NCRETE DECKS .NEW CONSTRUCTION, REROOF (TEAR -OFF) oR RECOVER , -. - - = SYSTEM TYPED PRELIMINARILYATTACHE-D INSULATION, MECHANICALLYATTACHEO BASE SHEET, BONDED ROOF COVER NOTE; INSULATION IS_OPTIONAL FOR RECOVER'APPLICATIONS System Deck 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP No. (Note Type Attach Base Fasteners Attach Base Ply Cap Ply (Psf) Min. 22 ga ; type-B,— — _ _ One or7nore— — Polyglass Elastobase, Polyglass OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap (Optional) One or SC-8. Grade 33 steel or min. layers, any Prelim. Elastobase Poly or JNI Perma-- with Roofgrip #14, Dekfast Hex and 18-inch o.c. in two, more BP -AA or APP- SBS-AA, SBS- -45.0* 2,500 psi structrual combination Attached Ply 28 wiYh Dekfast#14 or-Trufast-MP 3 equally spaced, staggered TA, APP-TA concrete with Tru Fast HD center rowsTA ----- Polyglass Elastobase, Polyglass -- Min. 22 ga., type B, Elastobase Poly, Polyglass G2 OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap Grade 33 steel or min. One or more Prelim. Base, CertainTeed Glasbase, with Roofgrip #14, Dekfast Hex and 12-inch o.c. in two, (Optional) One or SBS-AA, SBS- SC-9. 2,500 psi structrual layers, any Attached Firestone MB Base, JM Perma- with Dekfast #14 or TruFast MP-3 equally spaced, staggered more BP -AA or APP- TA, APP-TA -52.5 concrete combination Ply 28, Tamko Glass Base or with Tru Fast HD center rows TA GAFGLAS #75 Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap SBS-SA, APP- SC-10. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase Poly with with Roofgrip #14, Dekfast Hex and 12-inch o.c. in two, One or more SBS-SA SA, SBS-TA -52.5* 2,500 psi structrual combination Attached poly top surface with Dekfast#14 orTruFast MP-3 equally spaced, staggered or APP-TA concrete with Tru Fast HD center rows Min. 22 ga., type B, One or more OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap (Optional) One or SC-il. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase or with Roofgrip #12 (steel only) or and 12-inch o.c. in two, more BP -AA or APP- SBS-AA, SBS- 60.0 2,500 psi structrual Attached Polyglass Elastobase Poly equally spaced, staggered TA, APP-TA concrete combination #14 center rows TA Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom'Plates (square) 12-inch o.c. in 4-inch lap SBS-SA, APP- SC-12. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase Poly with with Roofgrip #12 (steel only) orOne and 12-inch o.c. in two, or more SBS-SA SA, SBS-TA -60.0* 2,500 psi structrual combination Attached poly top surface #14 equally spaced, staggered or APP-TA concrete center rows Min. 22 ga., type B, One or more SC-13. Grade 80 steel or min. layers, any Prelim. TriBuilt APP Smooth Dekfast isofast IF-2.375-AT Plates 12-inch o.c. in the 5-inch (Optional) APP-TA SBS-TA, APP- 82.5 2,500 psi structrual combination Attached with Dekfast #15 HS wide, heat -welded side lap TA concrete Min. 22 ga., type B, Grade 80 steel or min. One or more Prelim. Trufast 2.4 in. Barbed Seam 12-inch o.c. in the 6-inch SBS-TA, APP- SC-14. 2,500 psi structrual layersany Attached TriBuilt APP Smooth Plates with Trufast EHD Fasteners wide, heat -welded side lap (Optional) APP-TA TA 82.5 concrete combination Min. 22 ga., type B, One or more Dekfast Hex with Dekfast #14 or 12-inch o.c. in the 4-inch SC-15. Grade 33 steel or min. layers, any Prelim. TriBuilt APP Smooth OMG Flat Bottom Plates with lap and 18-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS- -112.5 2,500 psi structrual combination Attached OMG Roofgrip #14 equally spaced, staggered APP-TA TA, APP-TA concrete I I I I center rows Exterior Research and Design, U.C. d/b/a Trinity( ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 GP EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL36027-R2 Revision 2: 09/25/2017 Appendix 1, Page 10 of 26 �`.rTRRINITY IERD -TABLE 3A: STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION OR: REROOF'(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION; BONDED ROOF COVER " SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Type Attach Type Attach Base Ply Ply Cap Ply (psfl SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: - - Structural (Optional) Min. 1.5-inch H-Shield or Multi -Max (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-1 concrete ASTM D41 FA3 D-IS base insulation D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 67.5 Structural (Optional) (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 2 Min. 1.5-inch ACFoam II or ENRGY 3 D-IS D-IS SBS-SA 135.0 concrete ASTM D41 base insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C-3 concrete None Min.1.5-inch, min. 1.5 pcf Insulfoam D-IS insulation D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -157.5 Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C-4 None Min.1.5-inch, min. 2.0 pcf Insulfoam OB500 OB500 SBS-SA 120.0 concrete insulation SBS-SA or APP-TA SBS-TA or APP-TA C-5 Structural None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of OB500 SBS-SA (Optional) One or more SBS-SA, APP-SA, 127.5 concrete base insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-6 None Min. 1.5-inch ACFoam II or H-Shield OB500 OB500 SBS-SA 150.0 concrete base insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 1.5-inch ACFoam II, ENRGY 3, H- (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 7 concrete None Shield or Multi -Max FA3 M-OSFA base insulation M-OSFA SBS-SA SBS-SA or APP-TA---- _ -SBS=TA or APP-TA 232.5 Structural (Optional) additional layers_of_base- -� �- (Optional) One or more SBS-SA, APP-SA, C-8 None Min.1.5-inch, min. 2.0 pcf Insulfoam CR-20 �� CR-20 SBS-SA -240.0 concrete --- -insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural Min.1.5-inch ACFoam 11, ACFoam III, O tional additional layers(s)of ( p ) (Optional) One or more SBS-SA, APP-SA, C 9 None ENRGY 3, H-Shield, H-Shield CG , Multi- CR-20 CR-20 SBS-SA -270.0 concrete Max FA3 or ISO 95+GL base insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural OB (Optional) additional layers(s) of OB (Optional) One or more SBS-SA, APP-SA, C-10 None Min. 2-inch ACFoam II or H-Shield Classic Classic SBS-SA -270.0 concrete (FULL) base insulation (FULL) SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 1.5-inch ACFoam II, ACFoam III, (Optional) additional layers(s) of (Optional) One more SBS-SA, APP-SA, C-11 ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA HA SBS-SA -480.0 concrete Multi -Max FA3 base insulation 565 SA or APP-TA SBS-TA or APP-TA SELF -ADHERING SYSTEMS = BASE INSULATION AND COVERBOARD: Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 12 None Min. 1.5-inch Multi -Max FA3 D-IS D-IS SBS SA 67.5 concrete Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-13 None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-I5 D-IS SBS-SA -120.0 concrete Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 2-inch ACFoam 11, ENRGY-3 or H Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-14 concrete None Shield D-IS Fiber Roof Board D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 247.5 Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-15 None Min.1.5-inchENRGY3 OB500 OB500 SBS-SA 127.5 concrete Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for F1.36027-112 Certificate of Authorization #9503 dm EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 11 of 26 V I RINIIY I ERD TABLE 3A;'STRUCTURAL CONCRETE DECKS NEW CONSTRUCTION OR REROOF (TEAR -OFF); 7 'SYSTEM, YPE'A-1: BONDED INSULATIONS BONDED ROOF COVER' SEE NOTE,16 FOR VAPOR BARRIER OPTIONS - System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Structural -Min..-1.5=inch ACFoam II, H-Shield or Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS SA, APP-SA, C-16 concrete None ISO 95+GL OB500 -- _Deck Prime OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -150.0 Structural Min. 2-inch ACFoam II, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum _ (Optional) One or more SBS-SA, APP-SA, C-17 concrete None Shield OB500 Fiber Roof Board OB500 SBS=SA SBS-SA or APRTA _SBS_TA or APP-TA 24TS Structural Min. 1.5-inch ACFoam II, ENRGY 3, H- Min. 0.25-inch SECUROCK Gypsum (Optional) One or more SBS-SA, APP-SA, C-18 concrete None Shield or Multi -Max FA3 M-OSFA Fiber Roof Board M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 232.5 Structural Min. 2-inch ACFoam II, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-19 concrete None Shield M-OSFA Fiber Roof Board M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -247.5 Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-20 None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 CR-20 SBS-SA -240.0 concrete Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA Min. 1.5-inch Ultra -Max or Multi -Max Structural FA-3, min. 1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-21 concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 240.0 CG or ENRGY 3 Structural Min. 2-inch ACFoam II, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 22 concrete None Shield CR-20 Fiber Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 247.5 Structural OB Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more SBS-SA, APP-SA, C-23 None Min. 2-inch ACFoam II or H-Shield Classic Classic SBS-SA -350.0 concrete (FULL) Fiber Roof Board (FULL) SBS-SA or APP-TA SBS-TA or APP-TA Min. 1.5-inch ACFoam II, ACFoam III, Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-24 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Fiber Roof Board HA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -350.0 Multi -Max FA3 ,'ASPHALTAND/ORTORCHABPLIEbSYSTEMS .. -'� '`'� - - •- 3 Structural Min. 0.25-inch SECUROCK Gypsum (Optional) One or more C-25 concrete None Min. 2-inch ACFoam II or H-Shield D-IS Fiber Roof Board D-IS BP -AA BP AA SBS-AA 225.0 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-26 concrete None Min. 2-inch ACFoam II or H-Shield D-IS Fiber Roof Board D-I5 APP-TA APP-TA APP-TA -232.5 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-27 concrete None Min. 2-inch ACFoam II or H Shield OB500 Fiber Roof Board OB500 BP -AA BP -AA SBS AA 225.0 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-28 concrete None Min. 2-inch ACFoam II or H Shield OB500 Fiber Roof Board OB500 APP-TA APP-TA APP TA 232.5 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-29 concrete None Min. 2-inch ACFoam II or H-Shield M-OSFA Fiber Roof Board M-OSFA BP -AA BP AA SBS-AA 225.0 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-30 concrete None Min. 2-inch ACFoam II or H-Shield M-OSFA Fiber Roof Board M OSFA APP-TA APP TA APP TA 232.5 Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 12 of 26 �PTRRINITYJERD } TABLE 3A: STRUCTURAL CONCRETE DECKS —NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR$ARRIER'OPTIONS - System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 1.5-inch Ultra -Max or Multi -Max C-31 Structural FA-3, min.1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR-20 BP -AA BP AA SBS-AA 225.0 CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max Structural FA-3, min. 1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-32 concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR-20 APP-TA APP-TA APP-TA 232.5 CG or ENRGY 3 Structural (Optional) Min. 2-inch ACFoam II or H- OB Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more C-33 concrete None Shield Classic Fiber Roof Board Classic BP -AA BP -AA SBS-AA -225.0 (FULL) (FULL) Structural (Optional) Min. 2-inch ACFoam II or H- OB Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more C-34 concrete None Shield Classic Fiber Roof Board Classic APP-TA APP TA APP-TA -232.5 (FULL) (FULL) Structural Min. 1.5-inch ACFoam 11, ACFoam III, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-35 ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA HA BP AA —SBS-AA -225.0 concrete Multi -Max FA3 Fiber Roof Board —BP=AA Structural Min.1.5-inch ACFoam-II,-ACFoam-III; Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-36_ ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA HA APP-TA APP-TA -232.5 concrete Multi -Max FA3 Fiber Roof Board APP TA (Optional if (Optional if using AA C-37 Structural ASTM D41 Min. 0.75-inch FescoBoard HA None N/A using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -277.5 concrete (homogeneous) One or more APP-TA BP -AA AA or APP-TA Min. 1.5-inch ACFoam II, ACFoam III, (Optional if (Optional if using AA C-38 Structural ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.75-inch Fesco Board HA using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -290.0 concrete Multi -Max FA3 One or more AA or APP-TA APP-TA (Optional if Structural Min. 0.5-inch Structodek High Density using AA Ply) (Optional if using AA SBS-AA, SBS-TA, C 39 concrete ASTM D41 Fiberboard Roof Insulation HA None N/A One or more Base) One or more BP-. APP-TA 285.0 BP -AA AA orAPP TA Min. 1.5-inch ACFoam II, ACFoam III, (Optional if (Optional if using AA C-40 Structural ASTM D41 ENRGY 3, H Shield, H-Shield CG or HA Min. 0.5-inch Structodek High HA using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, 480.0 concrete Multi -Max FA3 Density Fiberboard Roof Insulation One or more AA or APP-TA APP TA BP AA Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 13 of 26 �I TRINITY I ERD TABLE,3A- STRUCTURAL`CONCRETE DECKS- NEW CONSTRUCTION OR REROOF,.(TEa R-OFF . d "' SYSTEM,.TYPE A-1.;BONDEq INSULATION; BONDED ROOF COVER . . = SEE NOTE,16 FOR VAPOR BARRIER OPTIONS ' System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (Psq — ----- -Min.-l:5-inch-ACFoam_II, ACFoam III, (Optional if (Optional if using AA C-41 Structural ASTM D41 � ENRGY 3, H-Shield, H-Shield CG or -- HA -Min.-0.2-5-inch"Dens Deck Prime HA using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -480.0 concrete Multi -Max FA3 � -- One or more AA or APP-TA APP-TA BPBP A� (Optional if (Optional if using AA C-42 Structural ASTM D41 Min. 0.25-inch Dens Deck Prime HA None N/A using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -510.0 concrete One or more AA or APP-TA APP TA BP -AA TABLE 36 STRUCTURAL` CONCRETE DECKS- NEW CONSTRUCTION OR REROOF.(TEAR=OFE) SYSTEM TYPE R NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER System No. Deck Primer Roof Cover (Note 15) MDP (Psf) Base Ply Ply Cap Ply C-43 Structural concrete ASTM D41 SBS-SA (Optional) 585-SA or APP-TA SBS-SA, APP-SA, SBS-TA or APP-TA -315.0 C-44 Structural concrete ASTM D41 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA -622.5 Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 14 of 26 V TRINITY (ERD TABLE4Ar LIGHTWEIGHTCONCRETE DECKS -NEW CONSTRUCTION.ORREROOF (TEAR -OFF) , SYSTEM 'TYPE A-1: BONDED INSULATION;, BONDED ROOF'COVER System Deck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) Concrete (Note 14) (Psfl SELF -ADHERING SYSTEMS WITHM BASE INSULATION AND 0PTIONAL TOP INSULATION OF THESAMETYPE: Structural Min. 200 psi, min 2- (Optional) Additional (Optional) One or SBS-SA, APP- LWC-1 concrete inch Elastizell Min.1.5-inch, min. 2.0 pcf Insulfoam OB500 layers of base insulation OB500 SBS-SA more SBS-SA SA _120.0 Structural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL (Optional) Additional (Optional) One or SBS-SA, APP- LWC-2 concrete inch Elastizell or H-Shield OB500 layers of base insulation OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 APP-TA or APP-TA Structural Min. 200 psi, min. (Optional) Additional (Optional) One or SBS-SA, APP- LWC-3 concrete 2-inch Elastizell Min. 2.0 pcf Insulfoam CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA SA _180.0 Structural Min. psi, min. Min.1.5-inch ACFoam II, ACFoam III, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-4 concrete 2-inchElastizell ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 FA3 APP-TA or APP-TA Structural Min. 200 psi, min. (Optional) Additional (Optional) One or SBS-SA, APP- LWC-5 concrete 2-inch Celcore or Min. 2.0 pcf Insulfoam CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA SA 222.5 Mearlcrete Structural Min. 200 psi, min. Min. 1.54 ch ACFoam II, ACFoam III, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-6 concrete 2-inch Celcore or ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA or SA_, S_BS-TA_ _ -222.5 Mearlcrete FA3 J_� _APP,TA--— or APP-TA - SELF -ADHERING SYSTEMS WITH BASE INSULATIONAND COVERBOARD: -- --- -- -- (Optional) One or SBS-SA,,APP- APP- LWC-7 Structural Min. psi, min 2- Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. OB500 SBS-SA more SBS-SA or SA, SBS-TA -120.0 concrete las inch Elastizell um -Finch Roof Board Gypsum -Fiber Roof Board APP-TA or APP-TA Structural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-8 concrete inch Elastizell or H-Shield OB500 Gypsum -Fiber Roof Board OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 APP-TA or APP-TA Structural Min. 200 psi, min. Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-9 concrete 2-inch Elastizell ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 FA3 or min. 2.0 pcf Insulfoam APP-TA or APP-TA Structural Min. 200 psi, min. Min.1.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-10 concrete 2-inch Celcore or ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 Mearlcrete FA3 or min. 2.0 pcf Insulfoam APP-TA or APP-TA -ASPHALT'AND/ORT,ORCHAPPLIED SYSTEMS:- - - •- - - - - - -- - - - - -_ (Optional) One or Structural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL Min. 0.25-inch SECUROCK BP -AA, SBS-AA, SBS- LWC-11 concrete inch Elastizell or H-Shield OB500 Gypsum -Fiber Roof Board OB500 APP-TA TA re BP -AA or APP- TA, APP-TA -225.0 Min.1.5-inch ACFoam II, ACFoam III, ENRGY 3, (Optional) One or Structural Min. 200 psi, min. Min. 0.25-inch SECUROCK BP -AA, SBS-AA, SBS- LWC-12 concrete 2-inch Elastizell ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 APP-TA more BP -AA or APP- TA APP TA -180.0 FA3 or min. 2.0 pcf Insulfoam TA Exterior Research and Design, U.C. d/b/aTrinitylERD Certificate of Authorization 49503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-112 for FL16027-112 Revision 2: 09/25/2017 Appendix 1, Page 15 of 26 �I TRINITY I ERD -TABLE4A: LIGHTWEIGHTCONCRETEbECKSCONSTRUCTION OR REROOF (TeAR-OFF) . - "'' " ~•' SYSTENiTYPEAA: BONDEDINSULATION BONDEDROOF_COVER•. System Deck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) Concrete (Note 14) (Psf) -- -Structural Min. 200 psi, min. Min.1.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK BP -AA, (Optional) One or SBS-AA, SBS- LWC-13 — 2-inch-Celcore_o� ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 CR-20 more BP -AA or APP- -222.5 concrete Mearlcrete FA3 or min. 2:O-pcf-Insulfoam—� Gypsum -Fiber Roof Board APP-TA TA TA, APP-TA _ . TABLE 4B: LIGHTWEIGHT CONCRETEDECKS CgNSTRUCT ION oR;REROOF (Tenn -OFF " - SYSTEM TYPE A-2: MECHANICALLY ATTACHEDANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER , System Deck Lightweight Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) Concrete to MDP No. (Note 1) (Note 14) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 1.5-inch Min. 22 a., g 7-inch o.c. at (Optional) Min. Thermaroof Composite, (Optional if Type B, Min. 300 psi 4-inch lap and 1.5-inch Polytherm Composite or (Optional if using AA Base) LWC-14 vented steel Approved GAFGLAS OMG CR 7-inch o.c. in ACFoam II, H- HA min. 0.5-inch Structodek HA using AA Ply) One or more SBS-AA, SBS- -45.0 at max. 5 ft cellular LWC #75 BSF two, equally Shield, Multi- High Density Fiberboard BP -AA BP -AA or APP- TA, APP-TA spaced center Max FA3 or Roof Insulation or min. spans rows Polytherm 0.75-inch FescoBoard TA (homogeneous) Min. 22 ga., 7-inch o.c. at Min. 1.5-inch 4-inch lap and Type B, Min. 300 psi GAFGLAS OMG CR 7-inch o.c. in ACFoam II, H- (Optional) One SBS-SA, APP- LWC-15 vented steel Approved #75 BSF two, equally Shield, Multi- HA None N/A SBS-SA or more SBS-SA SA, SBS-TA -45.0 at max. 5 ft cellular LWC spaced center Max FA3 or or APP-TA or APP-TA spans Polytherm rows Exterior Research and Design, LLC. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 e EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 16 of 26 �PTRRINITYJERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED 13ASE SHEET, BONDED ROOF COVER Base Sheet (Note A below) Roof Cover (Note 15) System Deck M DP Type Fasteners Attach Base Ply Cap Ply No. (Note 1) Lightweight Concrete (Note 14) (Psf) (Note A) 'GENERIC' CELLULAR LIGHTWEIGHT INSULATING'CONCRETE: .. Min. 300 psi, min. 2-inch thick cellular Min. 22 ga., type B steel LWC. Note: To qualify the LWIC under this 7-inch o.c. in a 3-inch lap and 7-inch o.c. in (Optional) LWC-16 at max 5 ft spans or assembly, an OMG CR BPF shall achieve B3 OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA, APP- -45.0 structural concrete an average withdrawal of 53lbf when field of the sheet BP -AA TA tested per TAS 105 or ANSI/SPRI FX-1 CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min. 0.0179-inch Tensilform S-75 or min. 8-inch o.c. in a 3-inch lap and 16-inch o.c. in Trufast FM-90 or One or more LWC-17 0.0205-inch Tensilform Min. 200 psi, min. 2-inch thick Celcore B1, B2, B3 or 137 two, equally spaced, staggered rows in the SBS-AA -37.5 75 at max. 5 ft spans or OMG CR BPF field of the sheet BP AA structural concrete Min. 22 ga., type B steel 7-inch o.c. in a 3-inch lap and 7-inch o.c. in LWC-18 at max 5 ft spans or Min. 200 psi, min. 2-inch thick Celcore B1 through B12 Trufast FM-90 or two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete OMG CR BPF field of the sheet BP AA Min. 26 ga., type HF B1, B2, 133, B4, 9-inch o.c. in a 3-inch lap'and 9-inch o.c. in— —� — LWC-19 steel at max 5 ft spans Min. 225 psi, min. 2-inch thick Celcore MF B7, 68, B10, Bll OMG CR BPF _two,-equallyspaced, staggered-- rows in the One or more SBS-AA -45.0 or structural concrete _ _or-B12� field of the sheet BP -AA Min. 22 ga., type B steel B1, B2, B3, B4, 7-inch o.c. in a 3-inch lap and 14-inch o.c. in LWC-20 at max 6 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B7, B8, B10, B11 OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete or B12 field of the sheet BP AA Min. 22 ga., type B steel Bl, B2, 133, B4, 9-inch o.c. in a 3-inch lap and 9-inch o.c. in LWC-21 at max 6 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B7, 138, B10, Bll OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete or B12 field of the sheet BP AA Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap and 18-inch o.c. in One or more Trufast Twin Loc- SBS-r A, SBS- LWC-22 at max 5 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF Bl or B2 Nail two, equally spaced, staggered rows in the BP -AA or APP- TA APP-TA -45.0 structural concrete field of the sheet TA or Min. 22 ga., type B steel 9-inch o.c. in a 4-inch lap and 18-inch o.c, in One or more SBS-SA, APP- LWC-23 at max 5 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- Trufast Twin Loc- two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 film top surface) Nail structural concrete field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel 8-inch o.c. in a 4-inch lap'and 8-inch o.c. in BP -AA or APP- SBS-AA, SBS- LWC-24 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF 132 Trufast FM-90 three equally spaced, staggered center rows TA TA or APP-TA -60.0 structural concrete Min. 22 ga., type B steel 82 (with poly- in a 4-inch lap and 8-inch o.c. in One or more SBS-SA, APP- LWC-25 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF Trufast FM-90 SBS-SA or SA, SBS-TA -60.0 film top surface) three quo.c three equally spaced, staggered center rows structural concrete APP-TA or APP-TA Exterior Research and Design, U.C. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVH2 EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-112 Revision 2: 09/25/2017 Appendix 1, Page 17 of 26 V TRINITY I ERD TABLE LIGHTWEIGHT CONCRETE-DECKS=NEW CONSTRUCTION oR_REROOF (TEAR OFF) SYSTEM TYPE E. MECHANICALLY ATTACHED BASE SHEET;;BONDED ROOF:COVER Base Sheet (Note A below) Roof Cover (Note 15) System Deck Lightweight Concrete (Note 14) MDP Type No. (Note 1) (Note A) Fasteners Attach Base Ply Cap Ply (Psf) Min. 22. ga�ty epty ep B-steel— Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more LWC-26 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore— —Bl through B12 two, equally spaced, staggered rows in the SBS-AA -75.0 structural concrete _OMG-CR_BP_F —field-of_the sheet BP AA Min. 22 ga., type. B steel Pol lass yg 10-inch o.c. in a 4-inch la and 10-in P (Optional) BP— —SBS=AA—SBS-- —90:0— LWC-27 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF Elastobase Poly Trufast FM three equally spaced, staggered center rows AA or APP-TA TA, APP-TA structural concrete ELASTRECL CELLULAR'LIGHTWEIGHTINSULATING CONCRETEC Min. 0.0179-inch Tensilform S-75 or min. Min. 200 psi, min. 2-inch thick Elastizell Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-AA, SBS- LWC-28 0.0205-inch Tensilform Range II B1 through B12 OMG CR BPF in two, equally spaced, staggered rows in the BP -AA or APP- TA or APP-TA -30.0 75 at max. 5 ft spans or field of the sheet TA structural concrete Min. 0.0179-inch Tensilform S-75 or min. Min. 200 psi, min. 2-inch thick Elastizell B2 (with poly- Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-SA, APP- LWC-29 0.0205-inch Tensilform Range II film top surface) OMG CR BPF in two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -30.0 75 at max. 5 ft spans or field of the sheet APP-TA or APP-TA structural concrete Min. 22 ga., type B steel Min. 200 psi, min. 2-inch thick Elastizell Trufast FM-90 orSBS-AA, .. 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more SBS- LWC-30 at max 5 ft spans or Bl through B12 two, equally spaced, staggered rows in the BP -AA or APP- -45.0 structural concrete Range II OMG CR BPF field of the sheet TA TA or APP-TA Min. 22 ga., type B steel Min. 200 psi, min. 2-inch thick Elastizell B2 (with poly- Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-31 at max 5 ft spans or Range II film top surface) OMG CR BPF two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SBS-AA, SBS- LWC-32 at max 5 ft spans or with Zell -Crete Fibers, supple -mentally B2 Nails (min. 1.8- three, equally spaced, staggered rows in the One or more TA, SBS-SA, -60.0 structural concrete attached with Roofgrip #21 and 3-inch inch) field of the sheet BP -AA APP-TA or plates at 1 per 8 ft2 APP-SA Min. 350 psi, min. 2-inch thick Elastizell Min. 22 ga., type B steel with Zell -Crete Fibers, supple -mentally B2 (with poly Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SBS-SA or SBS-SA, APP- LWC-33 at max 5 ft spans or attached with Roofgrip #21 and 3-inch film top surface) Nails (min. 1.8- three, equally spaced, staggered rows in the APP-TA SA, SBS-TA -60.0 structural concrete plates at 1 per 8 ft2 inch) field of the sheet or APP-TA MEARLCRETE;CELLULAR LIGHTWEIGHTINSULATI' CONCRETE , ,'_ F `, . , 1, 1 ' _ -- '-- - - l Min. 24 ga., type B steel t FM or 7.5-inch o.c. in a 3-inch lap and 10-inch o.c. One or more LWC-34 at max 5 ft spans or Min. 200 psi, min. 2-inch thick Mearlcrete B1 through 612 FOMG in two, equally spaced, staggered rows in the SBS-AA -30.0 structural concrete CR BPF field of the sheet BP AA Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for F1.36027-112 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 18 of 26 �I TRINITY I ERD TABLE4C: LIGHTWEIGHT CONCRETE ,DECKS—NEW`CONSTRUCTION ORREROOF(TFAR-OFF). ,SYSTEM TYPE 'E. MECHANICALLY ATTACHEDBASESHEET, 'BONDED 'ROOF COVER Base Sheet (Note A below) Roof Cover (Note 15) System Deck MDP Type Fasteners Attach Base Ply Cap Ply No. (Note 1) Lightweight Concrete (Note 14) (Psf) (Note A) Min. 22 ga., type B steel 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more LWC-35 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete Bl, B2 or B12 Trufast FM-90 or two, equally spaced, staggered rows in the BP -AA or APP- SBS-AA, SBS- -45.0 structural concrete OMG CR BPF field of the sheet TA TA orAPP-TA Min. 22 ga., type B steel 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-36 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- Trufast FM-90 or two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete film top surface) OMG CR BPF field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more LWC-37 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete Bl, 62, 63, B7 or Trufast FM-90 or two, equally spaced, staggered rows in the BP -AA or APP- SBS-AA, SBS- -52.5 structural concrete B11 OMG CR BPF I field of the sheet TA TA or APP-TA Min. 22 ga., type B steel 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete 82 (with poly- Trufast FM-90 or two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -52.5 structural concrete film top surface) OMG CR BPF field of the sheet APP-TA or APP-TA A. Base Sheets options are coded as follows: ➢ Bl: Polyglass G2 Base; B2: Polyglass Elastobase or Polyglass Elastobase Poly, B3: GAFGLAS #75; B4: GAFGLAS Stratavent Nailable Venting Base Sheet; B5: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6, B7: JM P_erma Ply No. 28; B8: JM Vensulation; B9: JM GlosPly IV, B10: JM GlasPly Premier; Bll: Tamko Glass -Base; B12: Tamko Vapor -Chan Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for F1.36027-112 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 19 of 26 �TRINITY I ERQ T TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS NEW CONSTRUCTION oa REROOF (TEaR=OFF) . Y SYSTEM TYPE A-1crBONDED INSULATION, 80NOED ROOF COVER -- System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) -- Min. 1.5-inch ACFoam II, Min. 0.25-inch Dens Deck, Dens Deck Prime, (Optional) One or CWF-1 Min. 2.5-inch Tectum ISO Shield, D-IS or -IS SECUROCK Gypsum -Fiber Roof Board or min. 0.5- D-IS or Bp -AA more BP -AA orAPP- SBS-AA, SBS-TA, 45.0 plank orTectum LS Plank -inch-Structodek High Density Fiberboard Roof OB500 APp TA therm, E Polytherm, ENRGY-3 Insulation TA Min. 2.5-inch Tectum Min. 1.5-inch ACFoam II, D-IS or Min. 0.25-inch Dens Deck, Dens Deck Prime, D-IS or SBS-SA or -(Optional) -One -or _ SBS=TA-SBS-SA,- CWF 2 Plank or Tectum LS Plank ISO H-Shield, OB500 SECUROCK Gypsum -Fiber Roof Board OB500 APP-TA more SBS-SA or App-TA, APP-SA _ 450— therm, Polytherm, ENRGY-3 APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch Dens Deck, Dens Deck Prime, (Optional) One or CWF-3 Min. 2.5-inch Tectum CR-20 SECUROCK Gypsum -Fiber Roof Board or min. 0.5- CR-20 BP -AA more BP -AA orAPP- SBS-AA, SBS-TA, 52.5 plank or Tectum LS Plank PolISO therm, ENRGH-Shi-3 Polytherm, ENRGY-3 inch Structodek High Density Fiberboard Roof TA APP TA Insulation Min. 2.5-inch Tectum Min.1.5-inch ACFoam II, Min. 0.25-inch Dens Deck, Dens Deck Prime, SBS-SA or (Optional) One or SBS-TA, 565-SA, CWF-4 Plank or Tectum LS Plank ISO 95+GL, H-Shield, CR-20 SECUROCK Gypsum -Fiber Roof Board CR-20 APP TA more SBS-SA or APP-TA, APP-SA -52.5 Polytherm, ENRGY-3 I I APP-TA Exterior Research and Design, U.C. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for F1.16027-112 Revision 2: 09/25/2017 Appendix 1, Page 20 of 26 ��PTRINITYJERD TABLE 5B:' CEMENTITIOUS WOOD FIBER DECKS —NEW CONSTRUCTION oR REROOF (TEAR -OFF) SYSTEM TYPEA-2: MECHANICALLYATTACHED ANCHOR SHEET, -BONDED INSULATION, BON DEO ROOF COVER - System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fastener Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Min. 2.5-inch Polyglass 9-inch o.c. in 4-inch ACFoam II, ACFoam Deck Prime, SECUROCK Gypsum- (Optional) Tectum Plank Elastobase, Trufast lap and 12-inch o.c. III, H-RGY Fiber Roof Board, Min. 0.75-inch One more SBS-AA, CWF-5 or Tectum LS Polyglass Inuldek in two, equally e,IS0ENRGY Shield, EN 3, HA FescoBoard (homogeneous) or HA BP -AA BP -AAA or SBS-TA, -30.0* Plank Elastobase Poly, Loc-Nail spaced, staggered Polytherm or Multi- min. 0.5-inch Structodek High APP-TA APP-TA Polyglass G2 Base center rows Density Fiberboard Roof Max FA3 Insulation Polyglass 9-inch o.c. in 4-inch Min. 1.5-inch Min. 2.5-inch Elastobase, Trufast lap and 12-inch o.c. ACFoam II, ACFoam Min. 0.25-inch Dens Deck, Dens SBS-SA (Optional) SBS-TA, CWF-6 Tectum Plank Polyglass Inuldek in two, equally III, IS095+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -30.0* or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, Fiber Roof Board TA SBS-SA or APP-TA, Plank Polyglass G2 Base center rows Polytherm or Multi- APP-TA APP-SA Max FA3 Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Min. 2.5-inch Polyglass 9-inch o.c. in 4-inch ACFoam II, ACFoam Deck Prime, SECUROCK Gypsum- (Optional) Tectum Plank Elastobase, Trufast lap and 18-inch o.c. III15095+GL, H- Fiber Roof Board, Min. 0.75-inch One more SBS-AA, CWF-7 or Tectum is Polyglass Twin in two, equally Shield,,, ENRGY 3, HA FescoBoard (homogeneous) or HA BP -AA BP -AA A or SBS-TA, -45.0* Plank Elastobase Poly, Loc-Nail spaced, staggered Polytherm or Multi- min. 0.5-inch Structodek High _— _ — APP-TA - -APP-TA Polyglass G2 Base center rows Density -Fiberboard -Roof - Max FA3 ------- Insulation Polyglass 9-inch o.c. in 4-inch Min. 1.5-inch Min. 2.5-inch Elastobase, Trufast lap and 18-inch o.c. ACFoam II, ACFoam Min. 0.25-inch Dens Deck, Dens SBS-SA (Optional) SBS-TA, CWF-8 Tectum Plank Polyglass Twin in two, equally II), IS095+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -45.0* or TectumLS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY3, Fiber Roof Board TA SBS-SA or APP-TA, Plank Polyglass G2 Base center rows Polytherm or Multi- APP-TA APP-SA Max FA3 Exterior Research and Design, LLC. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 e EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for F1.36027-112 Revision 2: 09/25/2017 Appendix 1, Page 21 of 26 �I TRINITYIERD ' TABLE DECKS- NEW CONSTRUCTION, REROOF(TEde-OFF)of RECOVER, .SC,'CWENTITIOUS`WOQUFIBER SYSTEM TYPE M •MECHANICALLYATTACHED BASE INSULATION, BONDED TOP INSULATION BONDED'ROOF,COVER System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note i) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (PsR -Min. ch Min. 2-inch H- OMG Polymer GypTec Plate : Min. 0.5-inch Structodek (Optional if using (Optional if using AA SBS-AA, CWF-9 Tectum Plank or -Shield -or— with Polymer GypTec or TruFast 1 per 4 ft High Density Fiberboard HA Base) One or more BP -AA SBS-TA, -45.0* Tectum LS Plank Polytherm TL Yin. Plate witFi TL Fastener— �_ Roof Insulation AA Ply) BP -AA or APP-TA APP-TA * TABLE 5D CEMENTITIOU$ WOOD FIBER'DECKS-'_NEW CONSTRUCTION, REROOF (TEAR-OFF)�OR'RECOVE' -77 SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION; BONDED ROOF COVER ; System Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Base Insulation Layer (PsR Type Fasteners Attach Base Ply Ply Cap Ply Min. 2.5-inch (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Prime (Optional if using AA SBS-AA, WF-10 Tectum Plank or more layers, any or SECUROCK Gypsum -Fiber Roof Board or Trufast Twin Loc-Nails 2 1 per 2 ft (Optional if using Base) One or more BP -AA SBS-TA, -45.0* Tectum LS Plank combination, loose min. 0.5-inch Structodek High Density (min. 1-inch embedment) AA Ply) BP -AA or APP-TA APP-TA laid Fiberboard Roof Insulation TABLE_SE: CEMENTITIOUS WOOD FIBER DECKS -NEW CONSTRUCTION'ok REROOF (TEAR -OFF) ;.- - SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACH BASE SHEET, BONDED ROOP COVER System Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply No. (Psf) Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Inuldek 9-inch o.c. in 4-inch lap and 12-inch o.c. in two, (Optional) One or SBS-AA, SBS-TA, CWF-11 or Tectum LS Plank Poly, Polyglass G2 Base Loc-Nail equally spaced, staggered center rows more BP -AA or APP-TA APP-TA 30.0 * Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Twin Loc- 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, (Optional) One or SBS-AA, SBS-TA, CWF-12 or Tectum LS Plank Poly, Polyglass G2 Base Nails equally spaced, staggered center rows more BP -AA or APP-TA APP-TA 45.0 * Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for F1.36027-112 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 22 of 26 ��TRINITYJERD TA6LE6A: GYPSUM DECKS— REROOF(TEAR-OFF) - SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Notes 1 & 12) (pso Type Attach Type Attach Base Ply Ply Cap Ply G-1 Existing, sound poured gypsum Min. 2.0 pcf, Insulfoam OB500 (Optional) additional layers(s) of base OB500 SBS-SA (Optional) One SBS-SA, APP-SA -112.5 or gypsum plank deck insulation or more SBS-SA (Optional) One G 2 Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or OB500 (Optional) additional layers(s) of base OB500 SBS-SA or more SBS-SA 565-SA, APP-SA, -112.5 or gypsum plank deck H-Shield insulation or APP-TA SBS-TA or APP-TA (Optional) One G-3 Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 SBS-SA or more SBS-SA SBS-SA, APP-SA, -112.5 or gypsum plank deck H-Shield or min. 2.0 pcf, Insulfoam Fiber Roof Board or APP-TA SBS-TA or APP-TA Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3, (Optional) additional layers(s) of base (Optional) One SBS-SA, APP-SA, G-4 or gypsum plank deck H-Shield or Multi -Max FA3 M-OSFA insulation and/or min. 0.25-inch M-OSFA SBS-SA or more SBS-SA SBS-TA or APP-TA 202.5 SECUROCK Gypsum -Fiber Roof Board or APP-TA G-5 Existing, sound poured gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers of base CR-20 SBS-SA (Optional) One SBS-SA, APP-SA -240.0 or gypsum plank deck insulation or more SBS-SA (Optional) One G-6 Existing, sound poured gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 SBS-SA or more SBS-SA SBS-SA, APP-SA, -240.0 or gypsum plank deck Fiber Roof Board or APP-TA SBS-TA or APP-TA (Optional — -- Existing, sound poured gypsum Min. 0.25-inch Dens Deck, Dens ----- — �N/A _ if using _(Optional_if-using-- AA Base) One or SBS-AA, SBS-TA, G-7 or gypsum plank deck Deck Prime or SEW ROCK Gypsum- CR-20 _ _None _ — - AA Ply) more BP -AA or APP-TA -245.0 Fiber Roof Board - ---- BP -AA APP-TA Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ACFoam III, (Optional) additional layers(s) of base (Optional) One SBS-SA, APP-SA, G-8 or gypsum plank deck ENRGY 3, H-Shield, H-Shield CG or CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA or more SBS-SA SBS TA or APP TA -257.5 Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board or APP-TA Exterior Research and Design, LLC. d/b/a TrinitylERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 0 EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-112 Revision 2: 09/25/2017 Appendix 1, Page 23 of 26 r�� ,( 1 tZI1VITY I ERD - TABLE 6B GYPSUM DECKS-REROOF (TEAR OFF) , :. " SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHORSHEET, BONDEWNSULATION, BONDED'ROOFCOVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) No. (Note 1) Type Fasteners (Note il) Attach Type Attach Type Attach Base Ply Ply Cap Ply MDP (Psf) -� -9-inch-o.c..in 4- Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Existing, sound Polyglass Trufast FM- inch lap and 18- ACFoam II,-ACFoam— Deck Prime, SECUROCK Gypsum - (Optional) poured gypsum Elastobase, 75 or FM- inch o.c. in two, III, IS095+GL, H- Fiber Roof Board,-Min..0.Z5=inch — _ One or more SBS-AA, G-9 or gypsum Polyglass 90 or Twin equally spaced, Shield, ENRGY 3, HA FescoBoard (homogeneous) or HA BP=AA BP -AA or _SBS=TA,_ -45.0* plank deck Elastobase Poly, Loc-Nails staggered center Polytherm or Multi- min. 0.5-inch Structodek High APP-TA APP-TA Polyglass G2 Base rows Max FA3, Density Fiberboard Roof Insulation ,. TABLE 6C:' GYPSUM DECKS REROOF (TEAR -OFF) OR RECOVER :. - _SYSTEMTYPE•C: NIECHANICALLYATTACHED INSULATION, BONDED ROOFCOVER , System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck G-10 Existing sound more layers, any Prime or SECUROCK Gypsum -Fiber Roof Board 0.5-inch Trufast Twin Loc- Nails 1-inch 1 2 ftZ (Optional if AA Ply) (Optional if using AA Base) One SBS-AA, SBS- poured gypsum or combination, loose or min. (min. per using or more BP -AA or APP-TA TA, APP-TA -45.0* gypsum plank deck laid Structodek High Density Fiberboard embedment) BP -AA Roof Insulation TABLE 61D: GYPSUM DECKS-REROOF (TEAR OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLYATTACHED BASE SHEET; BONDED'ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners (Note 11) Attach Base Ply Cap Ply (PsQ Existing sound poured Polyglass Elastobase, Polyglass Elastobase Yg Yg Trufast FM-75 or FM-90 or 9-inch o.c. in 4-inch la and 18-inch o.c. in P (Optional) One or more SBS-AA, SBS-TA, G-11 gypsum or gypsum Poly, Polyglass G2 Base Twin Loc-Nails two, equally spaced, staggered center rows BP -AA or APP-TA APP-TA _45.0* plank deck Exterior Research and Design, I.I.C. d/b/a Trinity ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modred Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 24 of 26 QCTRINITYIERD m. TABLE ZA: RECOVER APPLICATIONS - SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Substrate Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-1 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS insulation and/or min. 0.25-inch D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -67.5 SECUROCK Gypsum -Fiber Roof Board Existing (Optional) additional layers(s) of base (Optional) One or more R 2 asphaltic roof Min. 2.0 pcf Insulfoam D-IS insulation D-IS SBS-SA SBS-SA SBS-SA, APP-SA -90.0 Existing Min. 1.5-inch ACFoam II or ENRGY 3 or min. Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-3 asphaltic roof 2.0 pcf Insulfoam D-IS Roof Board D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA _90.0 Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-4 asphaltic roof Min. 1.5-inch ACFoam II or ENRGY 3 D-IS insulation and/or min. 0.25-inch D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -90.0 SECUROCK Gypsum -Fiber Roof Board Existing (Optional) additional layers of base (Optional) One or more R 5 asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 insulation OB500 SBS-SA SBS-SA SBS-SA, APP-SA 120.0 Existing Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-6 asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Roof Board OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -120.0 Existing Min. 1.5-inch ACFoam II, ENRGY 3 or FI- (Optional) additional layers(s) of base (Optional) One or more SBS SA, APP-SA, R-7 OB500 insulation and/or min. 0.25-inch OB500 SBS-SA - -127.5 asphaltic roof Shield -SECUROCK Gypsum -Fiber Roof Board -SBS=SA-orAPP-TA S85-TA or APP-TA Existing Min. 1.5-inch ACFoam II, ENRGY 3, H- M- (Optional) additional layers(s) of baseM- (Optional) One or more 585-SA, APP-SA, R-8 insulation and/or min. 0.25-inch SBS-SA -157.5 asphaltic roof Shield or Multi -Max FA3 OSFA SECUROCK Gypsum -Fiber Roof Board OSFA SBS-SA or APP-TA SBS-TA or APP-TA Existing (Optional) additional layers(s) of base (Optional) One or more R 9 asphaltic roof Min. 2.0 pcf Insulfoam CR-20 insulation CR-20 SBS-SA SBS-SA SBS-SA, APP-SA -240.0 Existing Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-10 asphaltic roof Min. 2.0 pcf Insulfoam CR-20 Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -240.0 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, (Optional) additional layers(s) of base R-11 Existing min. 1.3-inch ACFoam III or min.1.0-inch CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, -240.0 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA 3 Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-12 Min. 2-inch ACFoam II, ENRGY-3 or H-Shield CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA 247.5 asphaltic roof SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Existing Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One more S8S-AA, SBS-TA or R-13 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS SA, APP-TA BP -AA or APP-TA APP-TA -67.5 Board Existing Min. 1.5-inch ACFoam II or ENRGY 3 or min. Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-14 asphaltic roof 2.0 pcf Insulfoam D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS SA, APP-TA BP -AA or APP-TA APP-TA _90.0 Board Exterior Research and Design, U.C. d/b/a Trinity(ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6P EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-RZ Revision 2: 09/25/2017 Appendix 1, Page 25 of 26 2 ",,�TPUNITYJ ERE) TABLE 7A:' RECOVER SYSTEM TYPE,471.. BONDED INSULAT.ION..BONDED,ROOF COVER; ,� System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) M DP No. Substrate Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Existing Min. 1.5-inch ACFoam 11, ENRGY 3, H-Shield Min. 0.25-Inch Dens Deck, Dens Deck BP AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-15 asphaltic roof or ISO 95+GL OB500 Prime or SECUROCK Gypsum-Fiber.Roof OBSOD SA, APP-TA BP -AA or APP-TA APP-TA -127.5 Board Existing— Min. 1.5-inch ACFoam 11, ENRGY 3, H-Shield M- Min. 0.25-inch SECUROCK Gypsum -Fiber M_ BP -AA SBS- (Optional) one or more SBS-AA, SBS-TA or R-16 asphaltic roof or Multi -Max FX3— -OSFA­— -Roof Board _OSEA SA APP-TA BP -AA or APP-TA APP-TA -157.5 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min. 1.3-inch ACFoam III or min. 1.0-inch Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more R-17 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY CR-20 Roof Board CR-20 BP -AA BP -AA SBS-AA -225.0 3 or min. 2.0 pcf Insulfoarn Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min. 1.3-inch ACFoam III or min. 1.0-inch Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) one or more R-18 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY CR-20 Roof Board CR-20 APP-TA APP-TA APP-TA -232.5 3 or min. 2.0 pcf Insulfoarn -T 9E'7B:'kEt0VERA0PLicAf lom J SYSTIEIVITYPE F:AON-ANSULATED. BONDED,BASESHEET, 'BONDED; ROOF -OVER_ System Roof Cover (Note 15) MDP Deck Primer Base Ply Ply Cap Ply No. (Psf) R-19 Existing asphaltic roof ASTM D41 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0 Exterior Research and Design, LLC. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nierninen, PE-59166 6' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 26 of 26