Loading...
HomeMy WebLinkAboutPLAN1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SEI7 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. AC1318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND,LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED,. PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 --II-AGGREGATES -LARGE AGGREGATE 3/4"-MAX.. - ASTM-C 33---- -- III. AIR ENTRAINING +/- 1 % - ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS- ASTM A615, GRADE 60 11. WELDED WIRE FABRIC ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. FOOTING SIZE: EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB (3000 PSI) IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM.8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH V MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY W/ NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ALUMINUM SPECIFICATIONS: SCANNED BY 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 A[ f_jlLhJUft_ Unlhy OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. --C. FOR ALUMINUM-APPLICATION-USE#1OX1-1/2' SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 6-0" IN HEIGHT. •I MISCELLANEOUS: ST. LUCIE COUNT'F RUILp_® REVIE« ED FOR CONi'P ..e DATE qt6/tQs BE mm, \�11111111111111//� // N C) 4(/ N = W _ � co o O J o0 _ :.0 c) - Q z N 0 M c w w /0///111111111 �\N`\\\\\ 0 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE P_W = P_IC_T_URE_WINDOW- X = HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"4:044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"4.044" 2 x 5: 2"x5"x0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"xO.044" 1 x 3: 1 "x3"4.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"4.045" THESE PLAN AND ALL PROPOSED WORK ARE SUBJEC TO ANY CORRECTIONS REQUIRED FIELD INSPECTORS THAT MAY BE NEC SSARY IN ORDER TO 00NI Y M Ali, APPLICA04 00RS>i CONCE4LED FASTENERS ORQOACHMENTS ARE TH RESPONSIBILITY OF THE CON RACTOR OF RECORD SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"xO.050"xO.100" IN 2 x 6 SMB: 2"x6"xO.050"xO.120' 2 x 7 SMB: 2"x7"x0.057"x0.120" 2 x 8 SMB: 2"x8"xO.072"xO.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"x0.092"x0.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED IN INCHES. Uqto J 00 04 00 o Jn m rV ~ M M � w ZZQ E O U Lu J _ O0 c Lu E Lo •� Z F- LLI � a) ( Mc Z Q W- O 'd N Q U tY o LLlq- O a 00 J H U a J U)LL Z U) W O- U UJ Q w C F- H o CU Q W00� _ zLo co0 Lu 2rIL DESIGN DATE: 03/01/2018 REVISION 1: DATE PAGE: REVISION 2: DATE /� SCALE: NTS I THESE PLANS WERE PREPARED BASED ON THE PREMISE THAT THE EXISTING STRUCTURE WAS DESIGNED BY A PROPERLY LICENSED PROFESSIONAL ENGINEER OF THE STATE OF FLORIDA, WAS PERMITTED BY THE APPROPRIATE PERMITTING AGENCY, WAS CONSTRUCTED BY A FLORIDA LICENSED CONTRACTOR AT THE TIME OF CONSTRUCTION, -iAS NOT BEEN SUBJECT TO DAMAGE BY A MAJOR EVENT, AND HAS BEEN CERTIFIED 3Y THE CONTRACTOR THAT THE EXISTING STRUCTURE CURRENTLY SHOWS NO DEVIATIONS DR DEFECTS FROM THE STATE OF THE STRUCTURE AS PERMITTED BY THE FINAL INSPECTION OF THE PERMITTING AGENCY. ALSO, THE OWNER AND ALL PARTIES CONCERNED WILL NDEMNIFY FLORIDA ENGINEERING LLC FROM ANY DAMAGES OR CHANGES TO THE EXISTING STRUCTURE AS A RESULT OF ANY MODIFICATION OR FOR ANY OTHER REASON. Im --5X 3X.-f25-- - co V DOOR X > 2X2 DJ N -e m Q X > (n N C Z N 2X5SMB U� WN co Lf) N , N 1X2 v \ \\\\\Xxj1111111/'�/��/// ` N 2X6 SMB 2X6 SMB \�� o LL •.�� W a Lo Lo Lo =Z• : J N N N =D.Z o Lu Q- T- T-- r- _ 3 : W (o F- X x X oo v> j z co Cc M M M EXISTING SLAB 1 7'-102" 7'-102" J dam- C) 00 . 15'-9" F— M 4TH WALL CONSTRUCTION z Z o 0 N U LL (3 GYICTInIr_` flArllll II AR I r'%AG WJ I � 0) LIJ � LLI LL U .L N Z � LU - z O Q �r o --- QQ� �< v 0 LO LL LL 5'-9 2X3 m 3X2 m 2X3 co N 2 N X L Lo 2X2 N 2X2 N 2X2 1X2 EXISTING SLAB 5'-3"5'-3"-- 1- 5'-3" .I c l n" 0 U 00 O N 0 0 w Q 0 N co I- C) LU U U Nr 0 r` O 00 U (n � J J U) LL z W O U UJ Q 66 Lu W w U) o O� Q W00� 2 Zco0 Lu O Of a DESIGN DATE: 03/01/2018 REVISION 1: DATE PAGE: 2 REVISION 2: DATE SCALE: NTS (4) #10x3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) 3/8" 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE (TYP EACH SIDE) (SEE TABLE) O low O ANCHOR SPA (MIN) (TYP) (SEE TABLE) COLUMN SIZE 3/8" 0 CONCRETE SCREW ANCHOR B MIN SPA 2X3 0 0 2X4 1 3 2X5 1 3 2X6 1 4 2X7 1 5 2X8 2 3 2X9 2 4 2X10 - 2 4:5 - NOTES: SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2x3 MEMBER) / RIMARYZW" x0.125" ANGLE 2) 910x3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE O GI, (TYP EACH SIDE) "x2" BASE MEMBER (TYP EACH SIDE) 1) 3/8" 0 CONCRETE SCREW ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE �T' MIN. SCREW ANCHOR @ 24" O.C. BETWEEN COLUMNS (TYP EACH SIDE) 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2 3/4" AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTH AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D. FASTENERS, OTHER BRAND 8 TYPE SHALL BE APPROVED BY ENGINEER. 4. 2X3 W/ 1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 5. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTIONS SIMILAR IF - CONCRETE LINTEL IF WOOD LINTEL SUBSTITUTE 1/4" OX3" LAG SCREW FOR 3/8" 0 LDT FOR BOTH PRIMARY 8 SECONDARY ANGLES 6.2X2X.045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. 2"x3" OR LARGER UPRIGHT TO CONCRETE WMO PAVER DETAILS SCALE:NTS 24GAALUMINUM FLASHING #8 SMS W/ 5/8" NEO- \ WASHER 12" O/C \` FOR ALUMINUM PANS OR GALVALUME STEEL PANS USE #12 X 9/16" W/ 5/8" PLAN NEO-WASHER (3) PER PAN ROOF PER FOR COMPOSITE PANELS #12 X 1" LG. THAN PANEL THICKNESS SMS W/ 1-1/2" NEO-WASHER 12" O/C (2) 3/8" THRU-BOLT SEE ALSO COL/EDGE BEAM ALTERNATES BEAM PER PLAN ADJACENT MOBILE HOME POST COL. PER PLAN 4TH WALL / ROOF TO C.B. CONNECTION SCALE: NTS i BEAM PER PLAN 0 BEAM PER PLAN i (2) 3/8" 0 THRU-BOLT Q SEE ALSO COUEDGE J BEAM ALTERNATES 2" X 1/8" RECEIVING CHANNEL POST W/ (2) 3/8" 0 STL BOLTS OR COL. PER PLAN OPTION #1 i i #10X3/4" TEKS EA. SIDE i WHERE MIDPOINT QUANITY = BEAM SIZE COL. IS INDICATED. (EXAMPLE FOR 2X6 USE: (6) #1 (4) #10xl 1/2" SMS i I INTO SCREW BOSSES i OPTION #2 BEAM TO COLUMN 2"x2" OR 2"x3" i I MEMBER I .062" ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (4) #10x3/4" INTO BEAM OR I I UPRIGHT (2) #14x3/4" EA LEG INTO I GIRT OR PURLIN (0.062" ANGLE CLIPS W/ (2) #14x3/4" SMS EA LEG) PRIGHT OR BEAM - SNAP OR SELF MATING OR HOLLOW - - --PURLIN OR GIRT TO -BEAM OR POST DETAIL SCALE:NTS NOTES 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (4) #10x5/8" S.M.S. MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/ (2) HINGES MINIMUM. 3. HINGS SHALL BE ATTACHED TO DOOR WITH (4) #10x5/8" S.M.S. FASTEN A VxZW.044" TO UPRIGHT W/ #12xV S.M.S. @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. TYPICAL SCREEN DOOR CONNECTION DETAIL SCALE:NTS FOR ALUMINUM PANS OR GALVALUME STEEL PANS USE #12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR COMPOSITE PANELS #12 X 1" LG. THAN PANEL THICKNESS SMS W/ 1-1/2" NEO-WASHER 12" O/C #10 SMS INTO EA. RISER OpE W STRUCTURAL ROOF SYSTEM (TYP.) DGE BEAM PER PLAN \0k\111111IIII/////// / co o O O.Z= z° U) SEE 4TH WALL/ROOF TO C.B. CONNECTION NEW OR EXISTING SUPPORT STRUCTURE {2) 3/8" DIA. X 3 1/2" THRU BOLTS OR 10-#10 (OR 8-#12, OR 5-#14) SMS EVENLY STAGGERED ON ONE SIDE, FLUSH WITH COLUMN -POST PER PLAN 3-1/8" X 1-1/2" X 1/8" BASE W/ (2) 1/4" DIA. TAPCONS OR EQUIV./ POST W/ (2) 3/8" DIA. X 3-1/2" THRU BOLTS - TOP OR SIDE MOUNT ALLOWED - ALUM. BASE INSERT W/ (2) 1/4" DIA X 2-1/4" TAPCONS (2" MIN. - EMBED.) SECURE ALUM. COL. W/ (2) 3/8" DIA. THRU BOLTS OR (5) #10 (OR (4) #12 OR (3) #14 SMS ON EACH SIDE OF COLUMN EW 4" 2500 PSI CONC. SLAB W/ MONO. I- MIN FOOTER OVER 6 MIL VISQUEEN 1- #5 CONT. (TYP.) CARPORT/ OPEN PATIO DETAIL W/ ROOF ATTACHMENT ........p. O ���� ///////0 1111111 ,�`\\\\ a .J m CD CO J Ul m co co Zz � o E U U W J 0 00 0) W Z r a) � M Z Q O W N 2 0 Q-U- L( LL i DESIGN DATE: REVISION 1: REVISION 2: SCALE: IT O I,- d' O 00 T_ I— U J J m .J U) LL W WU UJ 0 W U) W00� _ � a EL 03/0112018 DATE PAGE: DATE NTS