1�
George Dzama, P:_E.
August 9, 2018 FILE C
Henry Hery
Pinnacle Roofing Services, LLC SC A*
5909 SW Markel Street BY
Palm City, FL 34990 St Lucie C
RE: St. Lucie County Building Dept. Pi
5804 Melville Road, Ft. Pierce, FL
Dear Mr. Hery:
I was contacted to perform a dry -in roof
associated permit issued by the St. Lucie
certification applies to a residential main
to the main structure is associated with a
Building Department.
12393 154' Road I Jupiter, FL 33478
OPY(772) 260-3371 1 gdzama@gmail.com
RECEIVED
AUG 3 2018
Parmittin9
ST. Lucie CowntYr
Structure Roof Permit
:ion for the above referenced residence and
Building Department. It is understood that this
with gable roof geometry. A flat roof attached
d permit issued by the St. Lucie County
The underlayment and secondary water intrusion barrier system installed consisted of layered
self -adhering bitumen Ultra HT Wind & Water Seal underlayment membrane (NOA #13-
1125.06). The underlayment mats were placed ith 6" end laps and 3" side laps over joints. A 26 gauge
galvalume drip edge and flashings were installed with #11 - 11/4" roofing nails.
This letter is to hereby certify that the installation of the stated dry -in underlayment and
secondary water intrusion barrier system was constructed in accordance to all applicable codes in
association with the above reference permit issued by the St. Lucie County Building Department.
No additions, alterations, or further proced
the dry -in inspection are considered in this
Respectfully Submitted,
George Dzama, P.E.
FL Professional Engineer License #73135�
phasing after the date of this certification letter of